Universal AC input/Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
Isolation class
LED indicator for power on
No load power consumption<0.5W
100% full load burn-in test
3 years warranty
SPECIFICATION
MODEL
DR-15-5
DR-15-12
DR-15-15
DR-15-24
DC VOLTAGE
5V
12V
15V
24V
RATED CURRENT
2.4A
1.25A
1A
0.63A
CURRENT RANGE
0 ~ 2.4A
0 ~ 1.25A
0 ~ 1A
0 ~ 0.63A
RATED POWER
12W
RIPPLE & NOISE (max.) Note.2 80mVp-p
OUTPUT
INPUT
4.75 ~ 5.5V
VOLTAGE ADJ. RANGE
21.6 ~ 26.4V
1.0%
LINE REGULATION
1.0%
1.0%
1.0%
1.0%
LOAD REGULATION
1.0%
1.0%
1.0%
1.0%
SETUP, RISE TIME
1000ms, 50ms/230VAC
HOLD UP TIME (Typ.)
70ms/230VAC
VOLTAGE RANGE
85 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
1000ms, 50ms/115VAC at full load
16ms/115VAC at full load
120 ~ 370VDC
EFFICIENCY (Typ.)
77%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
0.88A/115VAC
0.48A/230VAC
COLD START 35A/115VAC
65A/230VAC
Note.5
84%
83.5%
85%
105 ~ 160% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
27.6 ~ 32.4V
Protection type : Shut off o/p voltage, clamping by zener diode
-20 ~ +60 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85
, 10 ~ 95% RH
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:3KVAC
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3
EMC IMMUNITY
MTBF
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
DIMENSION
PACKING
NOTE
13.5 ~ 16.5V
1.0%
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
OTHERS
10.8 ~ 13.2V
1.0%
OVER VOLTAGE
(Note 4)
15.2W
150mVp-p
2.0%
PROTECTION
EMC
15W
120mVp-p
VOLTAGE TOLERANCE Note.3
OVERLOAD
SAFETY &
15W
120mVp-p
0.03%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
UL60950-1, TUV EN60950-1 approved, design refer to EN50178
1172.3K hrs min. MIL-HDBK-217F (25
25*93*56mm (W*H*D)
0.1Kg; 140pcs/15Kg/0.92CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Constant current operation region is within 60% ~100% rated output voltage. Protection type for short circuit is hiccup mode and will recover automatically
after fault condition is removed.
File Name:DR-15-SPEC 2011-06-17
DR-15
15W Single Output Industrial DIN Rail Power Supply
Mechanical Specification
Case No.985A
series
Unit:mm
67.2
44.2
56
47
26.7
4
46.5
46.5
93
N
5
Vadj.
5
25
35
LED
-V
L
+V
ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15
Block Diagram
RECTIFIERS
&
FILTER
EMI
FILTER
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
+V
-V
DETECTION
CIRCUIT
O.L.P.
CONTROL
O.V.P.
Derating Curve
Output Derating VS Input Voltage
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-20
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
70 (VERTICAL)
60
50
40
85
95
100
115
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz