XTAL AXIOM95 Vhf ocxo with sma connector Datasheet

Issue: 01
Specification
AXIOM95
Oscillator type : VHF OCXO with SMA connector
Parameter
min.
Frequency range
Standard frequencies
Frequency stability
Initial tolerance
vs. temperature in operating
temperature range (steady state)
80
130
96 / 100 / 101 / 116 / 130
operating temperature range
vs. supply voltage variation
vs. load change
Long term (aging) per day,
after 30 days operation
long term (aging) 1st year,
after 30 days operation
Frequency adjustment range
Electronic Frequency Control (EFC)
range
EFC voltage VC
-20
EFC slope (∆f / ∆VC)
EFC input impedance
RF output
Signal waveform
Load
Output level
Harmonics attenuation
Non-harmonics
Warm-up time
Supply voltage VS
typ.
max.
Unit Condition
± 200
± 100
± 50
± 25
70
± 10
± 10
± 10
±2
± 200
± 100
MHz
MHz
ppm
ppb
ppb
ppb
ppb
ppb
°C
ppb
ppb
ppb
ppb
ppb
ppb
Option II = “200”, “100”
Option II = “50”, “25”
Option II = “200”, “100”
Option II = “50”, “25”
3.15
4.75
ppm
ppm
V
V
Option II = “200”, “100”
Option II = “50”, “25”
Option I = “33”
Option I = “50” or “12”
± 500
±3
±1
0.15
0.25
Date: 2006-03-15
@+25°C, VC= 2.5V
Option II = “200”
Option II = “100”
Option II = “50”
Option II = “25”
positive
100
kΩ
Sinus
50
+3
30
50
5
3.45
5.25
12.6
400
300
150
1000
800
400
-25
+75
-40
+85
54x40.5x20 max.
50
Palette
3.15
4.75
11.4
Current consumption (steady state)
@ +25°C
Current consumption (warm-up)
3.3
5.0
12
Ω
dBm
dBc
dBc
min
V
V
V
mA
mA
mA
mA
mA
mA
°C
°C
mm
gram
∆ffinal/f0 < ±0.1 ppm
Option I = “33”
Option I = “50”
Option I = “12”
Option I = “33”
Option I = “50”
Option I = “12”
Option I = “33”
Option I = “50”
Option I = “12”
Operable temperature range
Storage temperature range
Enclosure (see drawing)
Weight
Packing
Notes:
1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated
Ordering Code:
Model (Specification)
AXIOM95
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
Option I Option II Frequency [MHz]
50
100
100.000
AXIOM95
page 1(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Enclosure drawing
Pin connections
Pin#
Symbol
1
VC
2
3
SMA
GND
VS
RF OUT
Function
Control Voltage
(EFC)
Ground
Supply Voltage
RF Output
Environmental conditions
Test
IEC 60068
Part ...
IEC 60679-1
clause ...
4.3
Visual inspection,
dimensions
Solderability
Resistance to
soldering heat
Shock*
2-20
2-58
4.6.3
2-27
4.6.8
Bump*
Free fall*
2-29
2-32
4.6.6
4.6.9
Test conditions
Enclosure styles as in IEC 60679-3 or 61837,
if applicable
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
Vibration, sinusoidal* 2-6
4.6.7
Rapid change of
temperature
Dry heat
2-14
4.6.5
2-2
4.6.14
Damp heat, cyclic*
2-30
4.6.15
Cold
2-1
4.6.16
Climatic sequence*
1-7
4.6.17
Damp heat, steady
state*
Endurance tests
- ageing
- extended aging
2-3
4.6.18
Test Ea, 3 x per axes 100g, 6 ms half-sine
pulse
Test Eb, 4000 bumps per Axes, 40g, 6 ms
Test Ed procedure 1,
2 drops from 1m height
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g
Test Na, 10 cycles at extremes of operating
temperature range
Test Ba, 16 h at upper temperature indicated
by climatic category
Test Db variant 1 severity b), 55°C/95% r.H.,
6 cycles
Test Aa, 2 h at lower temperature indicated by
climatic category
Sequence of 4.6.14, 4.6.15 (1st cycle), 4.6.16,
4.6.15 (5 cycles)
Test Ca, 56 days
4.7.1
4.7.2
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXIOM95
page 2(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Similar pages