Series AM4TW-RVZ 4 Watt | DC-DC Converter FEATURES: Models Single output Model AM4TW-2403S-RVZ AM4TW-2405S-RVZ AM4TW-2412S-RVZ AM4TW-2415S-RVZ AM4TW-4803S-RVZ AM4TW-4805S-RVZ AM4TW-4812S-RVZ AM4TW-4815S-RVZ Models Dual output Model AM4TW-2405D-RVZ AM4TW-2412D-RVZ AM4TW-2415D-RVZ AM4TW-4805D-RVZ AM4TW-4812D-RVZ AM4TW-4815D-RVZ • • • • Output Voltage (V) Output Current max (mA) Input Voltage (V) Output Voltage (V) Output Current max (mA) 9-36 9-36 9-36 9-36 18-72 18-72 18-72 18-72 Parameters Voltage Range Filter Start up time Peak Input Voltage time Absolute Max Rating Isolation Specifications Parameters Output Specifications Parameters Voltage Balance Voltage accuracy Short circuit protection Short circuit restart Line voltage regulation Load voltage regulation Temperature coefficient Ripple & Noise www.aimtec.com F 051e R13.B Operating temperature -40oC to + 85oC Input / Output isolation 1500 VDC Pin compatible with multiple manufacturers Continuous short circuit protection • • • • Input Voltage (V) Input Specifications Tested I/O voltage Resistance Capacitance Wide Input Range (4:1) 24 Pin DIP Package Metal package High efficiency up to 75% 9-36 9-36 9-36 18-72 18-72 18-72 3.3 5 12 15 3.3 5 12 15 ±5 ±12 ±15 ±5 ±12 ±15 1000 800 333 266 1000 800 333 266 ±400 ±166 ±133 ±400 ±166 ±133 Nominal Typical 24 Vin 20 15 -0.7-40 24 48 Conditions At 20MHz Bandwidth ±0.5 ±0.5 ±0.02 60 Maximum Continuous Auto Recovery Tel: +1 514 620 2722 1 of 3 Efficiency (%) 66 71 74 74 66 72 73 74 Efficiency (%) 70 72 75 70 72 73 Units VDC Ms Ms VDC 1500 Typical ±1 ±1 ±470 ±100 ±68 ±470 ±100 ±68 Rated > 1000 60 Balanced Load Capacitive load, max (μF) π (Pi) Network Typical 3 sec 1000 1000 320 220 1000 1000 320 220 Maximum 9-36 18-72 Conditions Capacitive load, max (μF) Units VDC MOhm pF Units % % % % %/oC mV p-p Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM4TW-RVZ 4 Watt | DC-DC Converter General Specifications Parameters Switching frequency Operating temperature Storage temperature Max Case temperature Cooling Humidity Case material Weight Dimensions(L x W x H) MTBF Conditions 100% load Full Load (see derating chart) Typical 100-400 Maximum -40 to +85 -40 to +125 Free air convection 100 Units KHz o C o C o C 95 % Nickel coated copper 15 g Tolerance ±0.5 mm or ±0.02 inches 1.25 x 0.8 x 0.4 inches 31.75 x 20.32 x 10.16 mm >2,200,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC) Safety Specifications Parameters Standards Designed to meet IEC 60950-1 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Pin Out Specifications Pin 2 3 9 11 14 16 22 23 Single -V Input -V Input No pin N.C. +V Output -V Output +V Input +V Input www.aimtec.com F 051e R13.B 1500 VDC Dual -V Input -V Input Common -V Output +V Output Common +V Input +V Input Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM4TW-RVZ 4 Watt | DC-DC Converter Dimensions 22.86 (0.90) 0.50 (0.02) 20.32 (0.80) 2 3 9 11 15.24 (0.60) 31.75 (1.25) Bottom View 23 22 16 14 5.08 (0.20) 2.54 (0.10) Built-in Stand-offs to ease PCB cleaning 3.05 (0.12) 10.16 (0.40) Printed Face Derating Free Air Convection 85 º C Output Power % 100 80 60 Safe Operating Area 40 20 0 -40 0 25 50 75 85 100 Ambient Temperature º C NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R13.B Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only