CP1L.fm 1 ページ 2012年3月26日 月曜日 午後5時14分 CP series CP1L CPU Unit CP1L-EM@@D@-D/CP1L-EL@@D@-D CP1L-M@@DR-A/CP1L-L@@DR-A High Performing Programmable Controller with Embedded Ethernet • "CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port. • "CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port. • Function blocks (FB) allow you to build up modular structure and programming of ladder diagrams. CP1L-EL CPU Units with 20 Points CP1L-EM CPU Units with 40 Points CP1L-L CPU Units with 10 Points CP1L-M CPU Units with 60 Points Features • "CP1L-EM" and "CP1L-EL" have complete with a Ethernet port. • Pulse output for two axes. Advanced power for high-precision positioning control. • High-speed Counters. Single-phase for four axes. • Six interrupt inputs are built in. Faster processing of instructions speeds up the entire system. • Serial Communications. Two ports. Select Option Boards for either RS-232C or RS-485 communications. • "CP1L-M" and "CP1L-L" have a peripheral USB port. • The Structured Text (ST) Language. Makes math operations even easier. • Can be used for the CP1W series Unit. The extendibility of it is preeminently good. • LCD displays and settings. Enabled using Option Board. 1 CP1L.fm 2 ページ 2012年3月19日 月曜日 午後1時18分 CP1L Model Number Structure ■ Model Number Legend(Not all models that can be represented with the model number legend can necessarily be produced.) CP1L-@@@D@-@ (1) (2) (3) (4) (5) 3. Number of Built-In number I/O points 60 : 60 I/O points 40 : 40 I/O points 30 : 30 I/O points 20 : 20 I/O points 14 : 14 I/O points 10 : 10 I/O points 1. Expansion capability E : Ethernet port None : 2. Program capacity M : 10K steps L : 5K steps 4. Output classification R : Relay outputs T : Transistor Outputs (sinking) T1 : Transistor Outputs (sourcing) 5. Power supply A : AC D : DC Ordering Information ● International Standards • The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives. • Contact your OMRON representative for further details and applicable conditions for these standards. ■ CPU Units CPU Unit CP1L-EM CPU Units with 40 Points CP1L-EM CPU Units with 30 Points CP1L-EL CPU Units with 20 Points CP1L-M CPU Units with 60 Points CP1L-M CPU Units with 40 Points CP1L-M CPU Units with 30 Points CPU type Memory capacity: 10K steps High-speed counters: 100 kHz, 4 axes Pulse outputs: 100 kHz, 2 axes (Models with transistor outputs only) Memory capacity: 10K steps High-speed counters: 100 kHz, 4 axes Pulse outputs: 100 kHz, 2 axes (Models with transistor outputs only) Memory capacity: 5K steps High-speed counters: 100 kHz, 4 axes Pulse outputs: 100 kHz, 2 axes (Models with transistor outputs only) Memory capacity: 10K steps High-speed counters: 100 kHz, 4 axes Pulse outputs: 100 kHz, 2 axes (Models with transistor outputs only) Memory capacity: 10K steps High-speed counters: 100 kHz, 4 axes Pulse outputs: 100 kHz, 2 axes (Models with transistor outputs only) Memory capacity: 10K steps High-speed counters: 100 kHz, 4 axes Pulse outputs: 100 kHz, 2 axes (Models with transistor outputs only) Specifications Power Output method supply Inputs Outputs Relay output DC power supply DC power supply Transistor output (sinking) 24 16 CP1L-EM40DT1-D Relay output CP1L-EM30DR-D 18 12 Transistor output (sinking) 12 8 AC power supply DC power supply AC power supply DC power supply CP1L-EL20DT-D CE CP1L-EL20DT1-D Relay output CP1L-M60DR-A Transistor output (sinking) CP1L-M60DT-A Relay output Transistor output (sinking) Transistor output (sourcing) Relay output Transistor output (sinking) Relay output Transistor output (sinking) Transistor output (sourcing) Relay output Transistor output (sinking) Relay output Transistor output (sinking) Transistor output (sourcing) CE CP1L-EL20DR-D Transistor output (sourcing) DC power supply CP1L-EM30DT-D CE CP1L-EM30DT1-D Relay output AC power supply CP1L-EM40DT-D Transistor output (sourcing) Transistor output (sinking) Standards CP1L-EM40DR-D Transistor output (sourcing) DC power supply Model 36 24 CP1L-M60DR-D UC1, N, L, CE CP1L-M60DT-D CP1L-M60DT1-D CP1L-M40DR-A CP1L-M40DT-A 24 16 CP1L-M40DR-D CP1L-M40DT-D UC1, N, L, CE CP1L-M40DT1-D CP1L-M30DR-A CP1L-M30DT-A 18 12 CP1L-M30DR-D CP1L-M30DT-D UC1, N, L, CE CP1L-M30DT1-D Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. Other company names and product names in this document are the trademarks or registered trademarks of their respective companies. 2 CP1L.fm 3 ページ 2012年3月19日 月曜日 午後2時57分 CP1L CPU Unit CP1L-L CPU Units with 20 Points CP1L-L CPU Units with 14 Points CP1L-L CPU Units with 10 Point CPU type Memory capacity: 5K steps High-speed counters: 100 kHz, 4 axes Pulse outputs: 100 kHz, 2 axes (Models with transistor outputs only) Memory capacity: 5K steps High-speed counters: 100 kHz, 4 axes Pulse outputs: 100 kHz, 2 axes (Models with transistor outputs only) Memory capacity: 5K steps High-speed counters: 100 kHz, 4 axes Pulse outputs: 100 kHz, 2 axes (Models with transistor outputs only) Specifications Power Output method supply Relay output AC power Transistor output supply (sinking) Relay output Transistor output DC power (sinking) supply Transistor output (sourcing) Relay output AC power Transistor output supply (sinking) Relay output Transistor output DC power (sinking) supply Transistor output (sourcing) Relay output AC power Transistor output supply (sinking) DC power supply Relay output Transistor output (sinking) Transistor output (sourcing) Inputs Outputs Model Standards CP1L-L20DR-A CP1L-L20DT-A 12 8 CP1L-L20DR-D CP1L-L20DT-D UC1, N, L, CE CP1L-L20DT1-D CP1L-L14DR-A CP1L-L14DT-A 8 6 CP1L-L14DR-D CP1L-L14DT-D UC1, N, L, CE CP1L-L14DT1-D CP1L-L10DR-A CP1L-L10DT-A 6 4 CP1L-L10DR-D UC1, N, L, CE CP1L-L10DT-D CP1L-L10DT1-D Note: 1. Refer to "Models and Software Versions" about supported software. 2. Refer to "Option Unit Specifications" about supported Option Units. ■ Options for CPU Units Name Specifications RS-232C Option Board Model Standards CP1W-CIF01 UC1, N, L, CE RS-422A/485 Option Board Can be mounted in either CPU Unit Option Board slot 1 or 2. *1 RS-422A/485 (Isolated-type) Option Board CP1W-CIF11 CP1W-CIF12 UC1, N, L, CE Ethernet Option Board Can be mounted in either CPU Unit Option Board slot 1 or 2. *1 *2 *4 CP1W-CIF41 UC1, N, L, CE Analog Input Option Board Can be mounted in either CPU Unit Option Board slot 1 or 2. *3 2 analog inputs. 0-10V(Resolution:1/4000), 0-20mA (Resolution:1/2000). CP1W-ADB21 CE Analog Output Option Board Can be mounted in either CPU Unit Option Board slot 1 or 2. *3 2 analog outputs. 0-10V (Resolution:1/4000). CP1W-DAB21V CE Analog I/O Option Board Can be mounted in either CPU Unit Option Board slot 1 or 2. *3 2 analog inputs. 0-10V(Resolution:1/4000), 0-20mA(Resolution:1/2000). 2 analog outputs. 0-10V (Resolution:1/4000). CP1W-MAB221 CE LCD Option Board Can be mounted only in the CPU Unit Option Board slot 1. *1 CP1W-DAM01 UC1, L, N, CE Memory Cassette Can be used for backing up programs or auto-booting. CP1W-ME05M UC1, N, L, CE *1. *2. *3. *4. Cannot be used for the CP1L-L10. When using CP1W-CIF41 Ver.1.0, one Ethernet port can be added. CP1L-EM / EL only. Cannot be used for the CP1L-EM / EL. 3 CP1L.fm 4 ページ 2012年3月19日 月曜日 午後1時18分 CP1L ■ Programming Devices Specifications Name FA Integrated Tool Package CX-One Lite Version 4.@ Number of licenses CX-One Lite is a subset of the complete CX-One package that provides only the Support Software required for micro PLC applications. CX-One Lite runs on the following OS. OS: Windows XP (Service Pack 3 or higher), Vista or 7 Note: Except for Windows XP 64-bit version. Model Media Standards 1 license CD CXONE-LT01C-V4 --- 1 license *1 DVD *2 CXONE-AL01D-V4 --- CX-One Lite Ver. 4.@ includes Micro PLC Edition CXProgrammer Ver. 9.@. FA Integrated Tool Package CX-One Ver. 4.@ CX-One is a package that integrates the Support Software for OMRON PLCs and components. CX-One runs on the following OS. OS: Windows XP (Service Pack 3 or higher), Vista or 7 Note: Except for Windows XP 64-bit version. CX-One Ver. 4.@ includes CX-Programmer Ver. 9.@. Programming Device Connecting Cable for CP1W-CIF01 RS-232C Option Board *3 USB-Serial Conversion Cable *3 Connects Personal Computers, D-Sub 9-pin (Length: 2.0 m) Connects Personal Computers, D-Sub 9-pin (Length: 5.0 m) For anti-static connectors XW2Z-200S-CV XW2Z-500S-CV Connects Personal Computers, D-Sub 9-pin (Length: 2.0 m) XW2Z-200S-V Connects Personal Computers, D-Sub 9-pin (Length: 5.0 m) XW2Z-500S-V USB-RS-232C Conversion Cable (Length: 0.5 m) and PC driver (on a CD-ROM disc) are included. Complies with USB Specification 1.1 On personal computer side: USB (A plug connector, male) On PLC side: RS-232C (D-sub 9-pin, male) Driver: Supported by Windows 98, Me, 2000, and XP CS1W-CIF31 --- N Note: 1. Refer to "Models and Software Versions" about supported software. 2. The CX-One and CX-One Lite cannot be simultaneously installed on the same computer. *1. Multi licenses are available for the CX-One (3, 10, 30 or 50 licenses). *2. The CX-One is also available on CD (CXONE-AL@@C-V4). *3. Cannot be used with a peripheral USB port. To connect to a personal computer via a peripheral USB port, use commercially-available USB cable (A or B type, male). The following tables lists the Support Software that can be installed from CX-One CX-One Lite Ver.4.@ Support Software in CX-One CX-One Ver.4.@ CX-One Lite Ver.4.@ Support Software in CX-One Micro PLC Edition CX-Programmer Ver.9.@ Yes No CX-Drive Ver.2.@ Yes Yes CX-Programmer Ver.9.@ No Yes CX-Process Tool Ver.5.@ No Yes CX-Integrator Ver.2.@ Yes Yes Faceplate Auto-Builder for NS Ver.3.@ No Yes Switch Box Utility Ver.1.@ Yes Yes CX-Designer Ver.3.@ Yes Yes CX-Protocol Ver.1.@ No Yes NV-Designer Ver.1.@ Yes Yes CX-Simulator Ver.1.@ Yes Yes CX-Thermo Ver.4.@ Yes Yes CX-Position Ver.2.@ No Yes CX-ConfiguratorFDT Ver.1.@ Yes Yes CX-Motion-NCF Ver.1.@ No Yes CX-FLnet Ver.1.@ No Yes CX-Motion-MCH Ver.2.@ No Yes Network Configurator Ver.3.@ Yes Yes CX-Motion Ver.2.@ No Yes CX-Server Ver.4.@ Yes Yes Note: For details, refer to the CX-One Catalog (Cat. No: R134). ● Models and Software Versions The following versions of the CX-One, CX-Programmer are required. Model CX-One CX-Programmer CP1L-EM40@@-@ CP1L-EM30@@-@ CP1L-EL20@@-@ *1 Ver. 4.25 or higher Ver. 9.40 or higher CP1L-M60@@-@ *2 Ver. 2.11 or higher Ver. 7.20 or higher CP1L-M40@@-@ CP1L-M30@@-@ CP1L-M20@@-@ CP1L-L14@@-@ *2 Ver. 2.10 or higher Ver. 7.10 or higher CP1L-L10@@-@ *2 Ver. 2.13 or higher Ver. 7.30 or higher *1. Update The CX-Programmer version automatically from the website using CX-Programmer version 9.0 (included with CX-One version 4.0). *2. Update The CX-Programmer version automatically from the website using CX-Programmer version 7.0 (included with CX-One version 2.0). 4 CX-One Ver.4.@ CP1L.fm 5 ページ 2012年3月19日 月曜日 午後1時18分 CP1L ■ Expansion Units Name Output method Inputs Outputs 24 16 Model Relay CP1W-40EDR Transistor (sinking) CP1W-40EDT Transistor (sourcing) CP1W-32ER Transistor (sinking) --- 32 CP1W-32ET Transistor (sourcing) N, L, CE CP1W-32ET1 Relay CP1W-20EDR1 Transistor (sinking) 12 8 CP1W-20EDT Transistor (sourcing) U, C, N, L, CE CP1W-20EDT1 Relay CP1W-16ER Transistor (sinking) --- 16 CP1W-16ET 8 --- CP1W-8ED 8 CP1W-8ER Transistor (sourcing) N, L, CE CP1W-16ET1 --Relay Transistor (sinking) --- Transistor (sourcing) Analog Input Unit N, L, CE CP1W-40EDT1 Relay Expansion I/O Units Standards Analog (resolution: 1/6000) 4 CP1W-8ET 8 U, C, N, L, CE CP1W-8ET1 --- CP1W-AD041 UC1, N, L, CE Analog Output Unit CP1W-DA041 2 CP1W-DA021 UC1, CE 2 1 CP1W-MAD11 U, C, N, L, CE 8 (I/O link input bits) 8 (I/O link input bits) CP1W-SRT21 Analog (resolution: 1/6000) Analog I/O Unit Analog (resolution: 1/6000) CompoBus/S I/O Link Unit --- Temperature Sensor Unit 4 --- 2 thermocouple inputs CP1W-TS001 4 thermocouple inputs CP1W-TS002 2 platinum resistance thermometer inputs CP1W-TS101 4 platinum resistance thermometer inputs CP1W-TS102 U, C, N, L, CE CP1L (L Type) CPU Units with 10 points do not support Expansion Units. ■ I/O Connecting Cable Name Specifications Model I/O Connecting Cable 80 cm (for CP1W/CPM1A Expansion Units) CP1W-CN811 Standards UC1, N, L, CE Note: An I/O Connecting Cable (approx. 6 cm) for horizontal connection is provided with CP1W/CPM1A Expansion Units. ■ Optional Products, Maintenance Products and DIN Track Accessories Name Battery Set DIN Track End Plate Specifications Model For CPU Units (Use batteries within two years of manufacture.) CJ1W-BAT01 Length: 0.5 m; Height: 7.3 mm PFP-50N Length: 1 m; Height: 7.3 mm PFP-100N Length: 1 m; Height: 16 mm PFP-100N2 There are 2 stoppers provided with CPU Units and I/O Interface Units as standard accessories to secure the Units on the DIN Track. PFP-M Standards CE --- 5 CP1L.fm 6 ページ 2012年3月27日 火曜日 午後4時39分 CP1L ■ Industrial Switching Hubs Specifications Product name Appearance No. of ports Functions Failure detection Accesories Current consumption (A) Model 0.22 W4S1-03B 0.22 W4S1-05B 0.22 W4S1-05C Standards • Power supply connector Quality of Service (QoS): EtherNet/IP control data priority Failure detection: Broadcast storm and LSI error detection 10/100BASE-TX, Auto-Negotiation Industrial Switching Hubs 3 No 5 No 5 Yes • Power supply connector • Connector for informing error UC, CE CE General Specifications Item Type AC power supply models Model CP1L-@@@-A DC power supply models CP1L-@@@-D Power supply 100 to 240 VAC 50/60 Hz 24 VDC Operating voltage range 85 to 264 VAC 20.4 to 26.4 VDC Power consumption 50 VA max. (CP1L-M60/-M40/-M30@@-A) 30 VA max. (CP1L-L20/-L14/-L10@@-A) 20 W max. (CP1L-EM40/-EM30/-M60/-M40/-M30@@-D) 13 W max. (CP1L-EL20/-L20/-L14/-L10@@-D) Inrush current * 100 to 120 VAC inputs: 20 A max. (for cold start at room temperature) 8 ms max. 200 to 240 VAC inputs: 40 A max. (for cold start at room temperature), 8 ms max. 30 A max. (for cold start at room temperature) 20 ms max. External power supply 300 mA at 24 VDC (CP1L-M60/-M40/-M30@@-A) 200 mA at 24 VDC (CP1L-L20/-L14/-L10@@-A) None Insulation resistance 20 MΩ min. (at 500 VDC) between the external AC terminals and GR terminals No insulation between primary and secondary for DC power supply Dielectric strength 2,300 VAC at 50/60 Hz for 1 min between the external AC and GR terminals, leakage current: 5 mA max. No insulation between primary and secondary for DC power supply Noise immunity Conforms to IEC 61000-4-4. 2 kV (power supply line) Vibration resistance CP1L-L/M: Conforms to JIS C60068-2-6. 10 to 57 Hz, 0.075-mm amplitude, 57 to 150 Hz, acceleration: 9.8 m/s2 in X, Y, and Z directions for 80 minutes each. Sweep time: 8 minutes × 10 sweeps = total time of 80 minutes) CP1L-EL/EM: 5 to 8.4 Hz, 3.5 mm amplitude, 8.4 to 150 Hz, acceleration: 9.8 m/s2 in X, Y, and Z directions for 100 minutes each (time coefficient of 10 minutes × coefficient factor of 10 = total time of 100 minutes) Shock resistance Conforms to JIS C60068-2-27. 147 m/s2 three times each in X, Y, and Z directions Ambient operating temperature 0 to 55°C Ambient humidity 10% to 90% (with no condensation) Ambient operating environment No corrosive gas Ambient storage temperature −20 to 75°C (Excluding battery.) Power holding time 10 ms min. 2 ms min. * The above values are for a cold start at room temperature for an AC power supply, and for a cold start for a DC power supply. • A thermistor (with low-temperature current suppression characteristics) is used in the inrush current control circuitry for the AC power supply. The thermistor will not be sufficiently cooled if the ambient temperature is high or if a hot start is performed when the power supply has been OFF for only a short time. In those cases the inrush current values may be higher (as much as two times higher) than those shown above. Always allow for this when selecting fuses and breakers for external circuits. • A capacitor charge-type delay circuit is used in the inrush current control circuitry for the DC power supply. The capacitor will not be charged if a hot start is performed when the power supply has been OFF for only a short time, so in those cases the inrush current values may be higher (as much as two times higher) than those shown above. 6 CP1L.fm 7 ページ 2012年3月27日 火曜日 午後4時39分 CP1L Performance Specifications ● CP1L CPU Unit (EM/EL Type) Type Models Item Control method I/O control method Program language Function blocks Instruction length Instructions Instruction execution time Common processing time Program capacity FB program memory Number of tasks Scheduled interrupt tasks Input interrupt tasks Maximum subroutine number Maximum jump number Input Area Built-in Input Area I/O areas Output Area Built-in Output Area 1:1 Link Area Serial PLC Link Area Work bits TR Area Holding Area AR Area Timers Counters DM Area Data Register Area Index Register Area Task Flag Area Trace Memory Memory Cassette Clock function Communications functions Memory backup Battery service life Built-in input terminals Number of connectable Expansion Units and Expansion I/O Units Max. number of I/O points Interrupt inputs Interrupt inputs counter mode Quick-response inputs Scheduled interrupts High-speed counters CP1L-EM40 (40 points) CP1L-EM30 (30 points) CP1L-EL20 (20 points) CP1L-EM40D@-@ CP1L-EM30D@-@ CP1L-EL20D@-@ Stored program method Cyclic scan with immediate refreshing Ladder diagram Maximum number of function block definitions: 128 Maximum number of instances: 256 Languages usable in function block definitions: Ladder diagrams, structured text (ST) 1 to 7 steps per instruction Approx. 500 (function codes: 3 digits) Basic instructions: 0.55 μs min. Special instructions: 4.1 μs min. 0.4ms 10K steps 5K steps 10K steps 288 (32 cyclic tasks and 256 interrupt tasks) 1 (interrupt task No. 2, fixed) 6 (interrupt task No. 140 to 145, fixed) (High-speed counter interrupts and interrupt tasks specified by external interrupts can also be executed.) 256 256 1,600 bits (100 words) CIO 0 to CIO 99 24 bits: CIO 0.00 to CIO 0.11 and 18 bits: CIO 0.00 to CIO 0.11 and 12 bits: CIO 0.00 to CIO 0.11 CIO 1.00 to CIO 1.11 CIO 1.00 to CIO 1.05 1,600 bits (100 words) CIO 100 to CIO 199 16 bits: CIO 100.00 to CIO 100.07 12 bits: CIO 100.00 to CIO 100.07 8 bits: CIO 100.00 to CIO 100.07 and CIO 101.00 to CIO 101.07 and CIO 101.00 to CIO 101.03 256 bits (16 words): CIO 3000.00 to CIO 3015.15 (CIO 3000 to CIO 3015) 1,440 bits (90 words): CIO 3100.00 to CIO 3189.15 (CIO 3100 to CIO 3189) 4,800 bits (300 words): CIO 1200.00 to CIO 1499.15 (words CIO 1200 to CIO 1499) 6,400 bits (400 words): CIO 1500.00 to CIO 1899.15 (words CIO 1500 to CIO 1899) 15,360 bits (960 words): CIO 2000.00 to CIO 2959.15 (words CIO 2000 to CIO 2959) 9,600 bits (600 words): CIO 3200.00 to CIO 3799.15 (words CIO 3200 to CIO 3799) 37,504 bits (2,344 words): CIO 3800.00 to CIO 6143.15 (words CIO 3800 to CIO 6143) 16 bits: TR0 to TR15 8,192 bits (512 words): H0.00 to H511.15 (H0 to H511) Read-only (Write-prohibited): 7168 bits (448 words): A0.00 to A447.15 (A0 to A447) Read/Write: 8192 bits (512 words): A448.00 to A959.15 (A448 to A959) 4,096 timer numbers: T0 to T4095 4,096 counter numbers: C0 to C4095 10 Kwords: D0 to D9999, D32000 32 Kwords: D0 to D32767 to D32767 16 registers (16 bits): DR0 to DR15 16 registers (32 bits): IR0 to IR15 32 flags (32 bits): TK0000 to TK0031 4,000 words (500 samples for the trace data maximum of 31 bits and 6 words.) A special Memory Cassette (CP1W-ME05M) can be mounted. Note: Can be used for program backups and auto-booting. Supported. Accuracy (monthly deviation): -4.5 min to -0.5 min (ambient temperature: 55°C), -2.0 min to +2.0 min (ambient temperature: 25°C), -2.5 min to +1.5 min (ambient temperature: 0°C) Built-in Ethernet Port (Connecting Support Software, Message Communications, Socket Service) A maximum of one Serial A maximum of two Serial Communications Option Boards can be Communications Option Board can mounted. be mounted. Flash memory: User programs, parameters (such as the PLC Setup), comment data, and the entire DM Area can be saved to flash memory as initial values. Battery backup: The Holding Area, DM Area, and counter values (flags, PV) are backed up by a battery. Service life expectancy is 5 years at 25°C, less at higher temperatures. (From 0.75 to 5 years depending on model, power supply rate, and ambient temperature.) 40 (24 inputs, 16 outputs) 30 (18 inputs, 12 outputs) 20 (12 inputs, 8 outputs) CP-series Expansion Units and CP-series Expansion Unit and Expansion I/O Units: 3 max. Expansion I/O Units: 1 max. 160 (40 built in + 40 per Expansion 150 (30 built in + 40 per Expansion 60 (20 built in + 40 per Expansion (I/O) Unit x 3 Units) (I/O) Unit x 3 Units) (I/O) Unit x 1 Unit) 6 inputs (Response time: 0.3 ms) 6 inputs (Response frequency: 5 kHz max. for all interrupt inputs), 16 bits Up or down counters 6 points (Min. input pulse width: 50 μs max.) 1 4 inputs/2 axes (24 VDC) Differential phases (4x), 50 kHz Single-phase (pulse plus direction, up/down, increment), 100 kHz Value range: 32 bits, Linear mode or ring mode Interrupts: Target value comparison or range comparison 7 CP1L.fm 8 ページ 2012年3月27日 火曜日 午後4時39分 CP1L Type Models Item Pulse outputs (models with transistor outputs only) Pulse outputs PWM outputs Analog input CP1L-EM40 (40 points) CP1L-EM30 (30 points) CP1L-EL20 (20 points) CP1L-EM40D@-@ CP1L-EM30D@-@ CP1L-EL20D@-@ Trapezoidal or S-curve acceleration and deceleration (Duty ratio: 50% fixed) 2 outputs, 1 Hz to 100 kHz (CCW/CW or pulse plus direction) Duty ratio: 0.0% to 100.0% (specified in increments of 0.1% or 1%) 2 outputs, 0.1 to 6553.5 Hz or 1 to 32,800 Hz (Accuracy: +1%/0% at 0.1 Hz to 10,000 Hz and +5%/0% at 10,000 Hz to 32,800 Hz) 2 input (Resolution: 1/1000, Input range: 0 to 10 V). Not isolated. ● CP1L CPU Unit (M/L Type) CP1L-M60 (60 points) CP1L-M40 (40 points) CP1L-M30 (30 points) CP1L-L20 (20 points) CP1L-L14 (14 points) CP1L-L10 (10 points) CP1L-M60@@-@ CP1L-M40@@-@ CP1L-M30@@-@ CP1L-L20@@-@ CP1L-L14@@-@ CP1L-L10@@-@ Type Item Models Control method Stored program method I/O control method Cyclic scan with immediate refreshing Program language Ladder diagram Function blocks Maximum number of function block definitions: 128 Maximum number of instances: 256 Languages usable in function block definitions: Ladder diagrams, structured text (ST) Instruction length 1 to 7 steps per instruction Instructions Approx. 500 (function codes: 3 digits) Instruction execution time Basic instructions: 0.55 μs min. Special instructions: 4.1 μs min. Common processing time 0.4 ms Program capacity 10K steps Number of tasks 288 (32 cyclic tasks and 256 interrupt tasks) Scheduled interrupt tasks Input interrupt tasks 5K steps 1 (interrupt task No. 2, fixed) 4 (interrupt task No. 2 (interrupt task No. 140 to 143, fixed) 140 to 141, fixed) 6 (interrupt task No. 140 to 145, fixed) (Interrupt tasks can also be specified and executed for high-speed counter interrupts and executed.) Maximum subroutine number 256 Maximum jump number Input Area 256 1,600 bits (100 words) CIO 0 to CIO 99 36 bits: CIO 0.00 to 24 bits: CIO 0.00 to Built-in Input CIO 0.11 and CIO CIO 0.11 and CIO 1.00 to CIO 1.11 and Area 1.00 to CIO 1.11 CIO 2.00 to CIO 2.11 Output Area I/O areas Built-in Output Area 18 bits: CIO 0.00 to CIO 0.11 and CIO 1.00 to CIO 1.05 12 bits: CIO 0.00 to CIO 0.11 8 bits: CIO 0.00 to CIO 0.07 6 bits: CIO 0.00 to CIO 0.05 12 bits: CIO 100.00 to CIO 100.07 and CIO 101.00 to CIO 100.03 8 bits: CIO 100.00 to CIO 100.07 6 bits: CIO 100.00 to CIO 100.05 4 bits: CIO 100.00 to CIO 100.03 1,600 bits (100 words) CIO 100 to CIO 199 24 bits: CIO 100.00 to CIO 100.07 and CIO 101.00 to CIO 101.07 and CIO 102.00 to CIO 102.07 16 bits: CIO 100.00 to CIO 100.07 and CIO 101.00 to CIO 101.07 1:1 Link Area 256 bits (16 words): CIO 3000.00 to CIO 3015.15 (CIO 3000 to CIO 3015) Serial PLC Link Area 1,440 bits (90 words): CIO 3100.00 to CIO 3189.15 (CIO 3100 to CIO 3189) Work bits 8,192 bits (512 words): W000.00 to W511.15 (W0 to W511) CIO Area: 37,504 bits (2,344 words): CIO 3800.00 to CIO 6143.15 (CIO 3800 to CIO 6143) TR Area 16 bits: TR0 to TR15 Holding Area 8,192 bits (512 words): H0.00 to H511.15 (H0 to H511) AR Area Read-only (Write-prohibited): 7168 bits (448 words): A0.00 to A447.15 (A0 to A447) Read/Write: 8192 bits (512 words): A448.00 to A959.15 (A448 to A959) Timers 4,096 timer numbers: T0 to T4095 Counters 4,096 counter numbers: C0 to C4095 DM Area 32 Kwords: D0 to D32767 Data Register Area 16 registers (16 bits): DR0 to DR15 Index Register Area 16 registers (32 bits): IR0 to IR15 Task Flag Area 32 flags (32 bits): TK0000 to TK0031 Trace Memory 4,000 words (500 samples for the trace data maximum of 31 bits and 6 words.) Memory Cassette A special Memory Cassette (CP1W-ME05M) can be mounted. Note: Can be used for program backups and auto-booting. Clock function Supported. Accuracy (monthly deviation): −4.5 min to −0.5 min (ambient temperature: 55°C), −2.0 min to +2.0 min (ambient temperature: 25°C), −2.5 min to +1.5 min (ambient temperature: 0°C) 10 Kwords: D0 to D9999, D32000 to D32767 One built-in peripheral port (USB 1.1): For connecting Support Software only. Communications functions 8 A maximum of two Serial Communications Option Boards can be A maximum of one Serial Communications Not supported. mounted. Option Board can be mounted. A maximum of two Ethernet Option Board can be mounted. When using CP1W-CIF41 Ver.1.0, one Ethernet Option Board can be mounted. A maximum of one Ethernet Option Board Not supported. can be mounted. Memory backup Flash memory: User programs, parameters (such as the PLC Setup), comment data, and the entire DM Area can be saved to flash memory as initial values. Battery backup: The Holding Area, DM Area, and counter values (flags, PV) are backed up by a battery. Battery service life Service life expectancy is 5 years at 25°C, less at higher temperatures. (From 0.75 to 5 years depending on model, power supply rate, and ambient temperature.) CP1L.fm 9 ページ 2012年3月27日 火曜日 午後4時39分 CP1L CP1L-M60 (60 points) Type Item Models CP1L-M60@@-@ CP1L-M40 (40 points) CP1L-M30 (30 points) CP1L-M40@@-@ CP1L-M30@@-@ 30 (18 inputs, 12 outputs) CP1L-L20@@-@ 20 (12 inputs, 8 outputs) CP1L-L14 (14 points) CP1L-L14@@-@ 14 (8 inputs, 6 outputs) CP1L-L10 (10 points) CP1L-L10@@-@ Built-in input terminals 60 (36 inputs, 24 outputs) Number of connectable Expansion Units and Expansion I/O Units CP-series Expansion Unit and Expansion I/O Units: 3 max. Max. number of I/O points 180 (60 built in + 40 160 (40 built in + 40 150 (30 built in + 40 60 (20 built in + 40 per Expansion (I/O) per Expansion (I/O) per Expansion (I/O) per Expansion (I/O) Unit × 1 Unit) Unit × 3 Units) Unit × 3 Units) Unit × 3 Units) 54 (14 built in + 40 per Expansion (I/O) Unit × 1 Unit) 10 (10 built in) Interrupt inputs 6 inputs (Response time: 0.3 ms) 4 inputs (Response time: 0.3 ms) 2 inputs (Response time: 0.3 ms) Interrupt inputs counter mode 6 inputs (Response frequency: 5 kHz max. for all interrupt inputs), 16 bits Up or down counters 4 inputs (Response frequency: 5 kHz max. for all interrupt inputs), 16 bits Up or down counters 2 inputs (Response frequency: 5 kHz max. for all interrupt inputs), 16 bits Up or down counters Quick-response inputs 6 points (Min. input pulse width: 50 μs max.) 4 points (Min. input pulse width: 50 μs max.) 2 points (Min. input pulse width: 50 μs max.) Scheduled interrupts 1 High-speed counters 4 inputs/2 axes (24 VDC): Differential phases (4x), 50 kHz Single-phase (pulse plus direction, up/down, increment), 100 kHz Value range: 32 bits, Linear mode or ring mode Interrupts: Target value comparison or range comparison Pulse outputs (models with transistor outputs only) 40 (24 inputs, 16 outputs) CP1L-L20 (20 points) 10 (6 inputs, 4 outputs) CP-series Expansion Units and Expansion Not supported. I/O Units: 1 max. Pulse outputs Trapezoidal or S-curve acceleration and deceleration (Duty ratio: 50% fixed) 2 outputs, 1 Hz to 100 kHz (CCW/CW or pulse plus direction) PWM outputs Duty ratio: 0.0% to 100.0% (specified in increments of 0.1% or 1%) 2 outputs, 0.1 to 6553.5 Hz or 1 to 32,800 Hz (Accuracy: +1%/0% at 0.1 Hz to 10,000 Hz and +5%/0% at 10,000 Hz to 32,800 Hz) Analog control 1 (Setting range: 0 to 255) Analog input 1 input (Resolution: 1/256, Input range: 0 to 10 V). Not isolated. 9 CP1L.fm 10 ページ 2012年3月19日 月曜日 午後1時18分 CP1L Built-in Inputs ■ Input Terminal Block Arrangement (Top Block) ● CP1L (20 Inputs) ● CP1L (60 Inputs) · AC Power Supply Models L1 L2/N COM 01 00 · AC Power Supply Models 03 02 05 04 07 06 09 08 11 10 00 − NC COM 01 00 03 02 03 02 05 04 07 06 09 08 11 10 05 04 07 06 09 08 11 10 Inputs (CIO 0) 01 00 03 02 01 00 Inputs (CIO 1) Inputs (CIO 0) · DC Power Supply Models + 01 03 02 05 04 07 06 09 08 11 L1 L2/N COM 10 Inputs (CIO 2) 05 04 07 06 09 08 11 10 01 00 03 02 07 06 09 08 11 05 04 07 06 09 08 11 10 10 · DC Power Supply Models + − COM NC Inputs (CIO 2) Inputs (CIO 1) 03 02 Inputs (CIO 0) 05 04 01 00 01 00 03 02 05 04 07 06 09 08 11 10 Inputs (CIO 0) ● CP1L (14 Inputs) ● CP1L (40 Inputs) · AC Power Supply Models L1 L2/N COM 01 00 · AC Power Supply Models 03 02 05 04 07 06 09 08 11 10 Inputs (CIO 0) 01 00 03 02 05 04 07 06 09 08 11 − NC COM 01 00 L2/N COM 01 00 Inputs (CIO 1) 03 02 05 04 07 06 09 08 11 10 01 00 03 02 05 04 07 06 09 08 11 10 + − COM NC Inputs (CIO 1) 01 00 · AC Power Supply Models L1 L2/N COM 01 03 05 07 09 11 01 03 02 04 06 08 10 Inputs (CIO 0) 00 02 04 NC − NC COM 00 01 02 05 04 07 06 09 08 11 10 01 00 03 02 Inputs (CIO 1) 05 04 Inputs (CIO 0) COM 01 03 Inputs (CIO 0) 10 02 · DC Power Supply Models Inputs (CIO 1) · DC Power Supply Models + 03 05 00 00 07 06 05 04 ● CP1L (10 Inputs) · AC Power Supply Models 01 03 02 Inputs (CIO 0) ● CP1L (30 inputs) L2/N COM 05 04 NC NC NC NC · DC Power Supply Models Inputs (CIO 0) L1 03 02 Inputs (CIO 0) · DC Power Supply Models + L1 10 NC 05 04 NC 00 03 02 05 04 Inputs (CIO 0) 07 06 NC NC NC NC CP1L.fm 11 ページ 2012年3月19日 月曜日 午後1時18分 CP1L ■ Built-in Input Area Input terminal block Number of inputs Word Input operation High-speed counter operation Origin search Origin searches enabled for pulse outputs 0 and 1 Bit Normal inputs 00 Normal input 0 --- --- High-speed counter 0 (increment) High-speed counter 0 (phase-A, increment, or count input) --- --- --- 01 Normal input 1 --- --- High-speed counter 1 (increment) High-speed counter 0 (phase-B, decrement, or direction) --- --- --- --- Pulse output 0: Origin proximity input signal --- Pulse output 0: Origin proximity input signal 02 Normal input 2 Interrupt Quick-response inputs inputs Operation settings • High-speed counters enabled • Phase-Z signal reset --- Two-phase Single-phase CPU Units CPU Units CPU Units (differential phase x4, (increment pulse with 20 to with 14 with 10 up/down, or pulse input) 60 points points points plus direction) --- High-speed counter 2 (increment) High-speed counter 1 (phase-A, increment, or count input) High-speed counter 1 (phase-B, decrement, or count input) --- Pulse output 1: Origin proximity input signal --- --- --- --- Pulse output 0: Origin input signal- 10 CIO 0 03 Normal input 3 --- --- High-speed counter 3 (increment) 04 Normal input 4 Interrupt input 0 Quick-response input 0 Counter 0, phaseZ/reset input High-speed counter 0 (phase-Z/reset) 05 Normal input 5 Interrupt input 1 Counter 1, phaseQuick-response input 1 Z/reset input High-speed counter 1 (phase-Z/reset) 06 Normal input 6 Interrupt input 2 Quick-response input 2 Counter 2, phaseZ/reset input Pulse output 0: Origin input signal --- 07 Normal input 7 Interrupt input 3 Quick-response input 3 Counter 3, phaseZ/reset input Pulse output 1: Origin input signal --- 08 Normal input 8 Interrupt input 4 Quick-response input 4 --- --- --- --- 09 Normal input 9 Interrupt input 5 Quick-response input 5 --- --- --- --- --- Pulse output 0: Origin proximity input signal --- --- --- --- 14 10 20 30 60 CIO 2 --- --- 11 Normal input 11 --- --- --- Pulse output 1: Origin proximity input signal 00 Normal input 12 --- --- --- --- --- --- to to to to to to to to to 05 Normal input 17 --- --- --- --- --- --- --- 06 Normal input 18 --- --- --- --- --- --- --- to to to to to to to to to 11 Normal input 23 --- --- --- --- --- --- --- 00 Normal input 24 --- --- --- --- --- --- --- to to to to to to to to to 11 Normal input 35 --- --- --- --- --- --- --- CIO 1 40 Normal input 10 --- 11 CP1L.fm 12 ページ 2012年3月19日 月曜日 午後1時18分 CP1L Built-in Outputs ■ Output Terminal Block Arrangement (Bottom Block) ● CP1L (60 Outputs) ● CP1L (20 Outputs) · AC Power Supply Models + - 00 01 02 · AC Power Supply Models 04 05 07 00 02 04 05 07 00 02 COM COM COM 03 COM 06 COM 01 03 COM 06 COM 01 CIO 101 CIO 102 CIO 100 · DC Power Supply Models NC 00 01 02 04 05 07 03 COM 06 + − 05 07 CIO 100 00 02 04 05 07 00 02 03 COM 06 COM 01 04 05 07 - 02 NC NC 03 04 COM COM COM COM 06 05 00 07 01 03 COM 02 04 COM 05 01 02 01 04 03 02 05 COM 04 03 COM(V-) 07 06 05 COM 07 06 CIO 100 03 CP1L-EL20DT1-D 04 06 00 01 03 04 06 V+ NC 00 V- CP1L-EM40DR-D/CP1L-M40D@-D 02 00 COM COM COM V+ 07 CIO 101 01 07 06 CP1L-EL20DT-D 05 · DC Power Supply Models 00 05 COM CIO 100 CIO 100 NC 04 03 03 COM 06 · AC Power Supply Models 01 02 · DC Power Supply Models CP1L-EL20DR-D/CP1L-L20D@-D CIO 102 CIO 101 ● CP1L (40 Outputs) 00 01 CIO 100 04 NC COM COM COM 03 COM 06 COM 01 + 00 COM COM COM COM COM COM COM 05 07 CIO 100 COM 02 COM 05 00 01 02 04 05 07 07 V- CIO 101 03 COM(V+) COM 06 CIO 100 CP1L-EM40DT-D V+ 00 V- 01 02 03 COM(V-) 04 COM 06 05 00 07 CIO 100 01 03 COM 02 04 COM ● CP1L (14 Outputs) 06 05 07 + CIO 101 − CP1L-EM40DT1-D V+ 00 · AC Power Supply Models 01 02 03 04 06 00 01 03 04 00 01 02 COM COM COM 04 03 05 COM NC NC CIO 100 06 · DC Power Supply Models V- COM(V+) COM 05 07 CIO 100 COM 02 COM 05 07 NC CIO 101 ● CP1L (30 Outputs) NC 00 01 02 COM COM COM 04 03 CIO 100 · AC Power Supply Models + 00 01 02 04 05 07 00 ● CP1L (10 Outputs) 02 · AC Power Supply Models COM COM COM 03 COM 06 CIO 100 COM 01 03 CIO 101 · DC Power Supply Models CP1L-EM30DR-D/CP1L-M30D@-D NC NC 00 01 02 COM COM COM 04 03 00 05 COM 07 06 00 COM 02 01 NC 03 01 02 04 03 05 COM 07 06 00 COM 02 01 03 CIO 101 CIO 100 CP1L-EM30DT1-D V+ V- 00 CIO 100 12 01 COM(V+) 02 04 03 05 COM 07 06 00 COM CIO 101 00 02 01 03 01 02 NC COM COM COM 03 CIO 100 CIO 101 COM(V-) 02 CIO 100 CIO 100 V+ 01 · DC Power Supply Models CP1L-EM30DT-D V- 00 COM COM COM 03 05 COM NC NC CP1L.fm 13 ページ 2012年3月19日 月曜日 午後1時18分 CP1L ■ Built-in Output Area Output Terminal Block When the instructions to the right are not executed When a pulse output instruction (SPED, ACC, PLS2, or ORG) is executed Number of outputs 10 CIO 100 Bit Normal output 00 Normal output 0 01 Normal output 1 02 Normal output 2 CW/CCW Pulse plus direction Pulse output 0 (CW) Pulse output 0 (pulse) Pulse output 0 (CCW) Pulse output 0 (direction) Pulse output 1 (CW) Pulse output 1 (pulse) Pulse output 1 (CCW) Pulse output 1 (direction) 30 CIO 101 40 CIO 102 CPU Units with 10 point PWM output --- --- --- --- --- PWM output 0 --- --- --- --- Origin search 0 (Error counter reset output) PWM output 1 03 Normal output 3 04 Normal output 4 --- --- Origin search 0 (Error counter reset output) --- --- 05 Normal output 5 --- --- Origin search 1 (Error counter reset output) --- --- 06 Normal output 6 --- --- --- --- --- 07 Normal output 7 --- --- --- --- --- 00 Normal output 8 --- --- --- --- --- to to to to to to 03 Normal output 11 --- --- --- 04 Normal output 12 --- --- --- to to to to to to to 07 Normal output 15 --- --- --- --- --- 01 Normal output 16 --- --- --- --- --- to to to to to to to 07 Normal output 23 --- --- --- --- --- 14 20 When the origin search function is used CPU Units with 14 to 60 points When the PWM instruction is executed Variable duty ratio pulse output Fixed duty ratio pulse output Word 60 When the origin search function is set to be used in the PLC Setup, and an origin search is executed by the ORG instruction to ----- 13 CP1L.fm 14 ページ 2012年3月19日 月曜日 午後1時18分 CP1L I/O Specifications for CPU Units ■ Input Specifications Specifications Interrupt inputs and quick-response inputs *1 Normal inputs CIO 0.00 to CIO 0.03 CIO 0.04 to CIO 0.09 *2 CIO 0.10 to CIO 0.11, CIO 1.00 to CIO 1.11, and CIO 2.00 to 2.11 *2 Input voltage 24 VDC +10%/–15% Applicable sensors 2-wire sensors or 3-wire sensors Input impedance 3.0 kΩ 4.7 kΩ Input current 7.5 mA typical 5 mA typical ON voltage 17.0 VDC min. 14.4 VDC min. OFF voltage/current 1 mA max. at 5.0 VDC ON delay *3 2.5 μs max. 50 μs max. 1 ms max. OFF delay *3 2.5 μs max. 50 μs max. 1 ms max. IN IN Input LED 3.0 kΩ Internal circuits IN COM 3.0 kΩ 910 Ω IN Input LED 1000 pF 4.3 kΩ Circuit configuration IN Input LED 1000 pF Internal circuits IN COM 4.7 kΩ 750 Ω ITEM High-speed counter inputs (phases A and B) *1 COM *1. High-speed counter inputs, interrupt inputs, and quick-response inputs can also be used as normal inputs. *2. The bits that can be used depend on the model of CPU Unit. *3. The response time is the hardware delay value. The delay set in the PLC Setup (0 to 32 ms, default: 8 ms) must be added to this value. ● High-speed Counter Function Input Specifications Input bits: CIO 0.00 to CIO 0.03 Item Specifications • Differential phase input mode • Pulse plus direction input mode • Increment mode • Up/down input mode 20.0 μs min. ON Phase A 10.0 μs min. ON/OFF delay 90% 50% 10% OFF ON ON Phase A 90% 50% 10% OFF 90% 50% 10% OFF T1 2.5 μs min. 2.5 μs min. T2 T3 T4 T1,T2,T3,T4 : 2.5 μs min ● Interrupt Input Counter Mode Input bits: CIO 0.04 to CIO 0.09 Item Specifications ON ON/OFF delay 90% 10% OFF 50 μs min. 50 μs min. ■ Output Specifications ● CPU Units with Relay Outputs Item Specifications Max. switching capacity 2 A, 250 VAC (cosφ = 1), 2 A, 24 VDC 4 A/common) Min. switching capacity 5 VDC, 10 mA Service life of relay Electrical Resis100,000 operations (24 VDC) tive load Induc48,000 operations (250 VAC, cosφ = 0.4) tive load Mechanical 20,000,000 operations ON delay 15 ms max. OFF delay 15 ms max. Output LED Circuit configuration Internal circuits OUT L L OUT COM Maximum 250 VAC: 2 A, 24 VDC: 2 A Note: There are restrictions in the power supply voltage and output load current imposed by the ambient temperature for CPU Units with DC power. Refer to the CP1L CPU Unit Operation Manual (Cat. No. W462) or the CP Series CP1L-EL/EM CPU Unit Operation Manual (Cat. No. W516). 14 Internal circuits CP1L.fm 15 ページ 2012年3月19日 月曜日 午後1時18分 CP1L ● CPU Units with Transistor Outputs (Sinking/Sourcing) Specifications CIO 100.00 to CIO 100.03 *1 4.5 to 30 VDC, 300 mA/output, 0.9 A/common, EM40D@-D 3.6 A/Unit EM30D@-D 2.7 A/Unit EL20D@-D 1.8 A/Unit M60D@-D 5.4 A/Unit M40D@-D 3.6 A/Unit M30D@-D 2.7 A/Unit L20D@-D 1.8 A/Unit L14D@-D 1.5 A/Unit L10D@-D 0.9 A/Unit 4.5 to 30 VDC, 1 mA 0.1 mA max. 0.6 V max. 1.5 V max. 0.1 ms max. 0.1 ms max. 1 ms max. CP1L-L/M CPU Unit: 1/common *3 CP1L-EL/EM CPU Unit: None Sinking Outputs Sinking Outputs Item Max. switching capacity Min. switching capacity Leakage current Residual voltage ON delay OFF delay Fuse V+ OUT Internal circuits CP1L-EL/EM CPU Unit OUT 24 VDC/ 20.4 to 26.4 VDC V− OUT CIO 100.04 to CIO 100.07 *2 OUT L L Internal circuits L L 24 VDC/4.5 to 30 VDC COM Š (-) 24 VDC/ 4.5 to 30 VDC Internal circuits COM (−) Sourcing Outputs Sourcing Outputs V+ 24 VDC/ 20.4 to 26.4 VDC V- COM (+) Internal circuits COM (V+) Internal circuits Internal circuits Circuit configuration OUT OUT OUT 24 VDC/ 4.5 to 30 VDC L OUT Sinking Outputs OUT OUT OUT L OUT L Internal circuits Internal circuits 4.5 to 30 VDC L L 4.5 to 30 VDC COM (−) CP1L-L/M CPU Unit L L Sinking Outputs Internal circuits 24 VDC/4.5 to 30 VDC L COM (−) Sourcing Outputs Sourcing Outputs COM (+) COM (+) Internal circuits Internal circuits Internal circuits 4.5 to 30 VDC OUT OUT 4.5 to 30 VDC L OUT L OUT L L Note: Do not apply a voltage or connect a load to an output terminal exceeding the maximum switching capacity. *1. Also do not exceed 0.9 A for the total of CIO 100.00 to CIO 100.03, which are different common. *2. The bits that can be used depend on the model of the CPU Unit. *3. The fuse cannot be replaced by the user. ● Pulse outputs ● PWM outputs Output bits CIO 100.00 to CIO 100.03 Item Output bits CIO100.01, CIO 100.03 Specifications Item Specifications Max. switching capacity 30 mA at 4.75 to 26.4 VDC Max. switching capacity 30 mA at 4.75 to 26.4 VDC Min. switching capacity 7 mA at 4.75 to 26.4 VDC Max. output frequency 32.8 kHz Max. output frequency 100 kHz PWM output precision For ON duty +1%, "0%:10 kHz output For ON duty +5%, "0%: 0 to 32.8 kHz output OFF 90% OFF Output waveform ON 10% ON ton Output waveform 4 ms min. 2 ms min. Note: 1. The above values assume a resistive load and do not consider the impedance of the cable connecting the load. 2. The pulse widths during actual use may be smaller than the ones shown above due to pulse distortion caused by connecting cable impedance. 3. The OFF and ON refer to the output transistor. The output transistor is ON at level “L”. T ON duty = ton × 100% T Note: The OFF and ON refer to the output transistor. The output transistor is ON at level “L”. 15 CP1L.fm 16 ページ 2012年3月19日 月曜日 午後1時18分 CP1L ■ External Analog Setting Input Specifications Item Specifications Number of analog inputs 1 Input signal range 0 to 10V Resolution 1/256 (full scale) Isolation method None Note: CP1L-L CPU Unit or CP1L-M CPU Unit only. ■ Analog Input Specifications Item Specifications Number of inputs 2 inputs (2 words allocated in the AR Area) Input signal range Voltage input: 0 V to 10 V Max. rated input 0 V to 15 V External input impedance 100 KΩ min. Resolution 1/1000 (full scale) Overrall accuracy 25°C: ± 2.0% (full scale) 0 to 55°C: ± 3.0% (full scale) A/D conversion data 0000 to 03E8 hex Averaging function Not supported Conversion time Same as PLC cycle time Isolation method None Note: CP1L-EL CPU Unit or CP1L-EM CPU Unit only. ■ Built-in Ethernet Specifications (CP1H-EL CPU Units or CP1H-EM CPU Unit Only) Item Specifications Protocol used TCP/IP, UDP, ARP, ICMP (ping only), BOOTP Applications FINS, Socket, SNTP, DNS (client) Media access method CSMA/CD Modulation method Baseband Transmission paths Star form Baud rate 100 Mbit/s (100Base-TX), 10 Mbit/s (10Base-T) 100 Mbit/s • Unshielded twisted-pair (UDP) cable Categories: 5, 5e • Shielded twisted-pair (STP) cable Categories: 100 Ω at 5, 5e 10 Mbit/s • Unshielded twisted-pair (UDP) cable Categories: 3, 4, 5, 5e • Shielded twisted-pair (STP) cable Categories: 100 Ω at 3, 4, 5, 5e Transmission media Transmission Distance 100 m (distance between hub and node) Item FINS Communications Service Specifications Number of nodes 254 Message length 1016 bytes max. Size of buffer 8k Communications Function FINS/UDP method FINS/TCP method FINS Communications Service (UDP/IP, TCP/IP) Protocol used UDP/IP Port number 9600 (default) Can be changed. Protection No Protocol used TCP/IP Number of connections Up to 2 simultaneous connections and only one connection can be set to client Port number 9600 (default) Can be changed. Protection Yes (Specification of client IP addresses when unit is used as a server) *1. CX-One version 4.3 or higher is required. *2. To connect the CP1L CPUs with the NS-series Programmable Terminals via Ethernet, make sure that the system version of NS Series is 8.2 or higher. 16 CP1L.fm 17 ページ 2012年3月19日 月曜日 午後1時18分 CP1L External Interfaces ■ CP1L CPU Unit Nomenclature ● CP1L CPU Units (EL Type) with 20 Points Terminal Block (Fixed) Battery DIP switch Memory Cassette slot Option Board slot Ethernet port Terminal Block (Fixed) ● CP1L CPU Units (EM Type) with 40 or 30 Points Option Board slots 1 (left) and 2 (right) Terminal Block (Removable) Battery DIP switch Memory Cassette slot External analog settings input connector Ethernet port Expansion I/O Unit connector Terminal Block (Removable) ● CP1L CPU Units (M Type) with 40 Points Option Board Slot 1 Option Board Slot 2 Terminal Block (Removable) Battery Peripheral USB Port IN L1 L2/N COM 01 00 03 02 05 04 07 06 09 08 11 10 01 00 03 05 02 04 00 01 COM 07 06 09 08 11 10 Analog Control 2 3 4 5 6 External analog settings input connector A{ 00 A| 01 COM 02 COM 03 COM 04 COM 06 05 07 03 02 04 COM 06 05 07 DIP switch OUT Memory Cassette Slot Terminal Block (Removable) Expansion Unit and Expansion I/O Unit Connector 17 CP1L.fm 18 ページ 2012年3月19日 月曜日 午後1時18分 CP1L ● CP1L CPU Units (L Type) with 20 or 14 Points ● CP1L CPU Units (L Type) with 10 Points Terminal Block (Fixed) Terminal Block (Fixed) IN L1 Option Board Slot L2/N COM 01 00 Memory Cassette Slot 03 02 05 04 07 06 09 08 11 10 SYSMAC CP1L Memory Cassette Slot PERIPHERAL BATTERY + - 00 COM 01 COM 02 COM 04 03 05 COM 07 06 OUT Battery Battery Terminal Block (Fixed) 18 Terminal Block (Fixed) CP1L.fm 19 ページ 2012年3月19日 月曜日 午後1時18分 CP1L Connection Methods ■ Built-in Standard Features Yes : Supported, No : Not supported Item Applicable CPU Units Interface CP1L-EM Type CP1L-EL Type Ethernet port Connecting Support Software, Message Communications, and the other. Yes Peripheral USB port Bus for communications with various kinds of Support Software running on a personal computer. No CP1L-M Type CP1L-L14/L20 CP1L-L10 Yes No No No No Yes Yes Yes ■ Option Unit Specifications Yes : Supported, No : Not supported Item Applicable CPU Units Option Boards Serial port 1 * (Option board slot 1) Serial port 2 * (Option board slot 2) CP1L-EM Type CP1L-EL Type CP1L-M Type CP1L-L14/L20 CP1L-L10 Yes Yes Yes No No No Yes Yes No Analog I/O Option Boards (CP1W-MAB21/ADB21/DAB21V) Yes Yes No No No LCD Option Boards (CP1W-DAM01) Yes Yes Yes Yes No Serial Communications Option Boards (CP1W-CIF01/CIF11/CIF12) Yes No Yes No No Ethernet Option Boards (CP1W-CIF41) No No Yes No No Analog I/O Option Boards (CP1W-MAB21/ADB21/DAB21V) Yes No No No No Serial Communications Option Boards (CP1W-CIF01/CIF11/CIF12) Yes Ethernet Option Boards (CP1W-CIF41) * You can choose one from among "Yes". ■ Serial Communications Option Boards (CP1W-CIF01/CIF11/CIF12) Product name Model Specifications RS-232C Option Board CP1W-CIF01 One RS-232C port Connector: D-Sub, 9 pin, female Maximum transmission distance: 15m One RS-232C connector (D-Sub, 9 pin, male) is included. (Plug: XM2A-0901, Hood: XM2S-0911-E) RS-422A/485 Option Board CP1W-CIF11 One RS-422A/485 port Terminal block: using ferrules Maximum transmission distance: 50m RS-422A/485 Isolated-type Option Board CP1W-CIF12 One RS-422A/485 port (Isolated) Terminal block: using ferrules Maximum transmission distance: 500m Serial communications mode Host Link, 1:N NT Link, 1:1 NT Link, Noprotocol, Serial PLC Link Slave, Serial PLC Link Master, Serial Gateway converted to CompoWay/F, and Tool Bus, 1:1 Link Master, and 1:1 Link Slave. Note: 1. Serial PLC Link can be used with either serial port 1 or serial port 2. 2. Cannot be used for the CP1L-L10. 19 CP1L.fm 20 ページ 2012年3月19日 月曜日 午後1時18分 CP1L ■ Ethernet Communications Specifications (CP1W-CIF41) Item Specifications Applicable PLCs CP1L CPU Units Note: The Ethernet Option Board cannot be used for the CP1L-EM/EL/L10. Number of Units that can be mounted 2 sets. (The CP1W-CIF41 Ver.1.0 and Ver.2.0 can be combined and used with one CPU Unit. When using CP1W-CIF41 Ver.1.0, only one unit can be mounted in an option board slot.) Protocol used TCP/IP, UDP Applications FINS Media access method CSMA/CD Modulation method Baseband Transmission paths Star form Baud rate 100 Mbit/s (100Base-TX), 10 Mbit/s (10Base-T) Transfer 100 Mbit/s • Unshielded twisted-pair (UDP) cable Categories: 5, 5e • Shielded twisted-pair (STP) cable Categories: 100 Ω at 5, 5e 10 Mbit/s • Unshielded twisted-pair (UDP) cable Categories: 3, 4, 5, 5e • Shielded twisted-pair (STP) cable Categories: 100 Ω at 3, 4, 5, 5e Transmission media Transmission Distance 100 m (distance between hub and node) Item FINS Communications Service Specifications Number of nodes 254 Message length 1016 bytes max. Size of buffer 8k Communications Function FINS/UDP method FINS/TCP method FINS Communications Service (UDP/IP, TCP/IP) Protocol used UDP/IP Port number 9600 (default) Can be changed. Protection No Protocol used TCP/IP Number of connections Up to 2 simultaneous connections and only one connection can be set to client Port number 9600 (default) Can be changed. Protection Yes (Specification of client IP addresses when unit is used as a server) Note: 1. CX-Programmer version 8.1 or higher (CX-One version 3.1 or higher) is required. 2. Use CX-Integrator version 2.33 or higher (CX-One version 3.1 or higher) when the system needs to be set the routing tables. However, CX-Integrator does not support the other functions, using CP1W-CIF41, such as transferring the parameters and network structure. 3. To connect the CP1H/CP1L CPUs with the NS-series Programmable Terminals via Ethernet using CP1W-CIF41, make sure that the system version of NS Series is 8.2 or higher. ■ Analog I/O Option Board (CP1W-ADB21/DAB21V/MAB221) Specifications Input Product name Model Voltage Input 0V to 10V Resolution:1/4000 Analog Input Option Board CP1W-ADB21 Analog Output Option Board Analog I/O Option Board Voltage Output 0V to 10V Resolution:1/2000 Resolution:1/4000 Conversion time 2CH - 2ms/point CP1W-DAB21V - 2CH 2ms/point CP1W-MAB221 2CH 2CH 6ms/4point Note: CP1L-EL CPU Unit or CP1L-EM CPU Unit only. 20 Output Current Input 0mA to 20mA CP1L.fm 21 ページ 2012年3月19日 月曜日 午後1時18分 CP1L ■ LCD Option board (CP1W-DAM01) ● Specifications Item Mounting port Communications protocol Weight Number of display characters Display characters Backlight Function CP1L: Option board slot 1 Note: The LCD Option Board cannot be used for the CP1L-L10. Peripheral bus (Turn ON DIP switch pin 4.) 30 g max. 4 rows × 12 characters: 48 characters max. 5 × 7 dots (alphanumeric and symbols). Electroluminescence (EL): Normal: Lit green; Error: Flashing red ● LCD Functions Operation Changing operating modes I/O memory PLC Setup operations Analog I/O monitor Error log display Memory cassette operation User monitor settings Message display function settings Day timer Description Change the PLC operating mode without using the CX-Programmer. Read and change the present values in the memory areas and force-set or force-reset bits. Read and change the PLC Setup. Monitor the analog adjustment and present value for the external analog setting input. Read the log of errors that have occurred. Transfer and verify user programs between the PLC and memory cassette. Read the status of up to 16 words and bits with comments. You can use this setting to read data on the startup display. Display a user-set message of up to 48 characters on the LCD Option Board when a specified bit turns ON. A maximum of 16 screens can be registered for display. Operation: Use this timer for ON/OFF switching at a specified times every day from the starting day of the week to the ending day of the week. Sixteen timers cam be set from timer 01 to timer 16. Starting day of the week Example: Monday Ending day of the week Example: Friday ON OFF Ending time Starting time Ending time Starting time Example: 9:00 Example: 17:00 9:00 17:00 Starting time 9:00 Ending time 17:00 Operation: Timers Weekly timer Use this timer for ON/OFF operation in intervals of one week that starts one day and ends another day. Sixteen timers cam be set from timer No. 01 to timer No. 16. Starting day of the week Example: Monday ON OFF Starting time Example: 12:00 Calendar timer Saving setting Language Other functions Use the calendar timers for ON or OFF operation in intervals of one year from the starting day to the ending day. Sixteen timers can be set from timer 01 to timer 16. Ending day of the week Example: Friday Ending time Starting time Example: 8:00 12:00 Ending time 8:00 Operation: ON OFF Starting day July 1 Ending day August 31 Set September 1 as the ending day. Save the various settings that you set with the LCD Option Board to the DM Area of the PLC. You can also write the settings saved in the PLC to the LCD Option Board. Changing the display language (Japanese/English) • Setting the time of the PLC's built-in clock • Reading system data (e.g., unit version and lot number) • Setting the backlight lighting time • Adjusting LCD contrast • Reading cycle time (e.g., average, maximum, and minimum) • Clearing data for the LCD Option Board 21 CP1L.fm 22 ページ 2012年3月19日 月曜日 午後1時18分 CP1L Expansion I/O Unit Specifications ■ CP1W-40EDR/40EDT/40EDT1/32ER/32ET/32ET1/20EDR1/20EDT/20EDT1/16ER/16ET/16ET1/8ED/8ER/8ET/8ET1 Expansion I/O Units Expansion I/O Units can be connected to the CPU Unit to configure the required number of I/O points. ● DC Inputs (CP1W-40EDR/40EDT/40EDT1/20EDR1/20EDT/20EDT1/8ED) Item Input voltage Input impedance Input current ON voltage OFF voltage ON delay OFF delay Specifications 24 VDC +10%/−15% 4.7 kΩ 5 mA typical 14.4 VDC min. 5.0 VDC max. 0 to 32 ms max. (Default: 8 ms) (See note 1.) 0 to 32 ms max. (Default: 8 ms) (See note 1.) IN IN 750 Ω Circuit configuration Input LED 4.7 kΩ Internal circuits COM Note: 1. Do not apply a voltage exceeding the rated voltage to an input terminal. 2. Can be set in the PLC Setup to 0, 0.5, 1, 2, 4, 8, 16 or 32 ms. The CP1W40EDR/EDT/EDT1 are fixed at 16 ms. 1ms min. (hardware delay value) ● Relay Outputs (CP1W-40EDR/32ER/20EDR1/16ER/8ER) Item Max. switching capacity Min. switching capacity Resistive Service Elec- load trical Inductive life of relay load Mechanical ON delay OFF delay Specifications 2 A, 250 VAC (cosφ = 1), 24 VDC 4 A/common 5 VDC, 10 mA 150,000 operations (24 VDC) 100,000 operations (24 VAC cos = 0.4) 20,000,000 operations 15 ms max. 15 ms max. Output LED Circuit configuration Internal circuits OUT L L OUT COM 22 Maximum 250 VAC: 2 A, 24 VDC: 2 A Note: There are restrictions in the power supply voltage and output load current imposed by the ambient temperature for CPU Units with DC power. Use the CPU Unit within the following ranges of power supply voltage and output load current. Refer to the CP1L CPU Unit Operation Manual (Cat. No. W462) or the CP Series CP1L-EL/EM CPU Unit Operation Manual (Cat. No. W516). CP1L.fm 23 ページ 2012年3月19日 月曜日 午後1時18分 CP1L ● Transistor Outputs (Sinking/Sourcing) (CP1W-40EDT/-40EDT1/-32ET/-32ET1/-20EDT/-20EDT1/-16ET/-16ET1/-8ET/-8ET1) Item Specifications CP1W-20EDT CP1W-16ET CP1W-20EDT1 CP1W-16ET1 CP1W-40EDT CP1W-32E CP1W-40EDT1 CP1W-32ET1 24 VAC +10%/ −5%: 0.3 A/point 4.5 to 30 VDC: 0.3 A/point 0.9 A/common 0.9 A/common 3.6 A/Unit 7.2 A/Unit 0. 1mA max. 1.5 V max. 0.1ms max. 1 ms max. at 24 VDC +10%/−5%, 5 to 300 mA 0.9 A/common 1.8 A/Unit 0.9 A/common 3.6 A/Unit 16 pts (100%) 8 pts (100%) Max. switching ca- 4.5 to 30 VDC: 0.3 A/point pacity (See note 3.) Leakage current Residual voltage ON delay OFF delay Max. number of Simultaneosly ON Points of Output Fuse (See note 2.) 24 pts (75%) 16 pts (100%) 8 pts (100%) Note: 1. Do not apply a voltage or connect a load to an output terminal exceeding the maximum switching capacity. 2. The fuses cannot be replaced by the user. 3. A maximum of 0.9 A per common can be switched at an ambient temperature of 50°C. 1/common Sinking Outputs Output LED Output LED OUT L Internal circuits 0.9 0.8 Sourcing Outputs L Circuit configuration CP1W-8ET CP1W-8ET1 • OUT00/01 4.5 to 30 VDC, 0.2 A/output • OUT02 to 07 4.5 to 30 VDC, 0.3 A/output 0.9 A/common 1.8 A/Unit OUT COM (−) COM (+) 24 VDC/ 4.5 to 30 VDC Internal circuits OUT L L OUT Common terminal current (A) 24 VDC/ 4.5 to 30 VDC 0 50 55 Ambient temperature (°C) 23 CP1L.fm 24 ページ 2012年3月19日 月曜日 午後1時18分 CP1L ■ CP1W-AD041/DA041/DA021/MAD11 Analog Units Analog values that are input are converted to binary data and stored in the input area, or binary data is output as analog values. ■ Analog Input Unit: CP1W-AD041 Model ■ Analog Output Unit: CP1W-DA041/DA021 CP1W-AD041 Item Input voltage Number of inputs 4 Input signal range 0 to 5 V, 1 to 5 V, 0 to 10 V, −10 to 10 V 0 to 20 mA 4 to 20 mA Max. rated input ±15 V ±30 mA External input impedance 1 MΩ min. Resolution 6000 25°C ±0.3% of full scale Overall accuracy 0 to 55°C ±0.6% of full scale Conversion time Model Input current CP1W-DA041/DA021 Item Input voltage Input current Number of outputs DA041: 4, DA021: 2 Output signal range 0 to 5 V, 0 to 10 V, or −10 to 10 V 0 to 20 mA or 4 to 20 mA Approx. 250 Ω Allowable external output load resistance 2 kΩ min. 350 Ω max. ±0.4% of full scale External output impedance 0.5 Ω max. --- Resolution 6000 ±0.8% of full scale 2 ms/point (8ms/4points) 25°C ±0.4% of full scale Overall accuracy 0 to 55°C ±0.8% of full scale Binary data with resolution of 6,000 A/D conversion data Full scale for −10 to 10 V: F448 to 0BB8 hex Full scale for other ranges: 0000 to 1770 hex Averaging Supported. Open-circuit detection Supported. Isolation method Photocoupler isolation between analog I/O and internal circuits (There is no isolation between the analog I/O signals.) Conversion time 2 ms/point (8ms/4points, 4ms/2points) D/A conversion data Binary data with resolution of 6,000 Full scale for −10 to 10 V: F448 to 0BB8 hex Full scale for other ranges: 0000 to 1770 hex Insulation resistance 20 MΩ min. (at 250 VDC between isolated circuits) Dielectric strength 500 VAC for 1 min between isolated circuits Isolation method Photocoupler isolation between analog I/O and internal circuits (There is no isolation between the analog I/O signals.) ■ Analog I/O Unit: CP1W-MAD11 Model CP1W-MAD11 Item Analog Input Section Analog Output Section Voltage I/O 2 inputs Input signal range 0 to 5 V, 1 to 5V, 0 to 10 V, or −10 to 10V Max. rated input ±15 V ±30 mA External input impedance 1 MΩ min. 250 Ω Resolution Overall accuracy 0 to 20 mA, 4 to 20 mA 1/6000 25°C ±0.3% of full scale ±0.4% of full scale 0 to 55°C ±0.6% of full scale ±0.8% of full scale A/D conversion data Binary data −10 to 10 V: F448 to 0BB8 hex Full scale for other ranges: 0000 to 1770 hex Averaging Supported (Set for each input using a DIP switch.) Disconnection detection Supported Number of outputs 1 output Output signal range 1 to 5 V, 0 to 10 V, −10 to 10 V External output max. current --- Allowable external output load resistance 1 kΩ min. 600 Ω max. External input impedance 0.5 Ω max. --- Resolution Overall accuracy 0 to 20 mA, 4 to 20 mA 1/6000 25°C ±0.4% of full scale 0 to 55°C ±0.8% of full scale D/A conversion data 24 Current I/O Number o f inputs Binary data (hexadecimal, 4 digits) −10 to 10 V: F448 to 0BB8 hex Full scale for other ranges: 0000 to 1770 hex Conversion time* 2 ms/point (6 ms for all points) Isolation method Photocoupler isolation between analog I/O and internal circuits (There is no isolation between the analog I/O signals.) CP1L.fm 25 ページ 2012年3月19日 月曜日 午後1時18分 CP1L ■ Temperature Sensor Units: CP1W-TS001/TS002/TS101/TS102 By mounting a Temperature Sensor Unit to the PLC, inputs can be obtained from thermocouples or platinum resistance thermometers, and temperature measurements can be converted to binary data and stored in the input area of the CPU Unit. ● Specifications Item Model CP1W-TS001/002 CP1W-TS101/102 Number of inputs 2 (TS001), 4 (TS002) 2 (TS101), 4 (TS102) Input types K, J switchable (Note: Same for all inputs.) Pt100, JPt100 switchable (Note: Same for all inputs.) Indication accuracy (The larger of the indicated value: ±0.5% and ±2°C (See note.)) ±1 (The larger of the indicated value: ±0.5% and ±1°C) ±1 digit max. digit max. * Conversion time 250 ms/2 points (TS001, TS101); 250 ms/4 points (TS002, TS102) Converted temperature data Binary Isolation method Photocoupler isolation between the temperature input signals. * The indication accuracy when using a K-type thermocouple for temperature less than −100°C is ±4°C±1 digit max. ● Input Temperature Ranges for CP1W-TS001/002 (The rotary switch can be used to make the following range and input type settings.) Input type K J Range (°C) Range (°F) −200 to 1300 −300 to 2300 0.0 to 500.0 0.0 to 900.0 −100 to 850 −100 to 1500 0.0 to 400.0 0.0 to 750.0 ● Input Temperature Ranges for CP1W-TS101/102 (The rotary switch can be used to make the following range and input type settings.) Input type Range (°C) Range (°F) Pt100 −200.0 to 650.0 −300 to 1200.0 JPt100 −200.0 to 650.0 −300 to 1200.0 ■ CP1W-SRT21 CompoBus/S I/O Link Unit The CompoBus/S I/O Link Unit functions as a slave for a CompoBus/S Master Unit (or an SRM1 CompoBus/S Master Control Unit) to form an I/O Link with 8 inputs and 8 outputs between the CompoBus/S I/O Link Unit and the Master Unit. CompoBus/S Master Unit (or SRM1 CompoBus/S Master Control Unit) CP1W-SRT21 CompoBus/S I/O Link Unit CP1L ● Specifications Item Model CP1W-SRT21 Master/Slave CompoBus/S Slave Number of I/O bits 8 input bits, 8 output bits Number of words occupied in CP1L I/O memory 1 input word, 1 output word (Allocated in the same way as for other Expansion Units) Node number setting Set using the DIP switch (before the CPU Unit is turned ON.) ON 1 2 3 4 5 6 No. COMM ERR SRT21 EXP BD H NC(BS+) BD L NC(BS-) NC CS/CJ Series C200H@ Series CQM1(H) Series SRM1 Series CPM2C-S Series Special flat cable or VCTF cable A maximum of 16 Units can be connected to one CompoBus/S I/O Link Unit. 25 CP1L.fm 26 ページ 2012年3月19日 月曜日 午後1時18分 CP1L I/O Bits and I/O Allocations With CP1L CPU Units, the beginning input and output words (CIO 0 and CIO 100) are allocated by the CPU Unit one or two words at a time. I/O bits are allocated in word units in order of connection to Expansion Units and Expansion I/O Units connected to a CPU Unit. Allocated words CPU Unit Inputs CP1L CPU Unit with 10, 14, or 20 I/O points CIO 0 CIO 100 CIO 0 and CIO 1 CIO 100 and CIO 101 CIO 0, CIO 1, and CIO 2 CIO 100, CIO 101, and CIO102 CP1L CPU Unit with 30 or 40 I/O points CP1L CPU Unit with 60 I/O points Outputs ● Example: I/O Bit Allocations When Expansion Units Are Connected CPU Unit with 40 I/O Points + Temperature Sensor Unit + Analog Output Unit + Expansion I/O Unit with 40 I/O Points Inputs Outputs CPU Unit with 40 I/O Points CP1L-M40D@-@ CIO 0.00 to CIO 0.11 CIO 1.00 to CIO 1.11 24 inputs 16 outputs CIO 100.00 to CIO 100.07 CIO 101.00 to CIO 101.07 2nd Unit 1st Unit Temperature Sensor Unit Analog Output Unit CP1W-DA041 CP1W-TS002 CIO 2 to 5 None None CIO 102 to CIO 105 3rd Unit Expansion I/O Unit with 40 I/O Points CP1W-40ED CIO 6.00 to CIO 6.11 CIO 7.00 to CIO 7.11 24 inputs 16 outputs CIO 106.00 to CIO 106.07 CIO 107.00 to CIO 107.07 The Number of the Maximum Connect of Expansion Unit ■ Maximum Number of CP1W/CPM1A Expansion Unit and Expansion I/O Units ● CP1L (EM, EL, M) CPU Units with 60, 40, or 30 Points 3 max. ● CP1L (L) CPU Units with 20 or 14 Points 1 max. 26 Note: CP1L (L Type) CPU Units with 10 points do not support Expansion Units. CP1L.fm 27 ページ 2012年3月19日 月曜日 午後1時18分 CP1L Dimensions (Unit: mm) ■ CPU Units CP1L-EM CPU Units with 40 Points 150 85 140 8 Weight: 675 g max. 110 100 90 Four, 4.5 dia. CP1L-EM CPU Units with 30 Points 130 85 120 8 Weight: 610 g max. 110 100 90 Four, 4.5 dia. CP1L-EL CPU Units with 20 Points 130 85 120 8 Weight: 610 g max. 110 100 90 Four, 4.5 dia. 27 CP1L.fm 28 ページ 2012年3月19日 月曜日 午後1時18分 CP1L CP1L CPU Units with 60 I/O Points 195 85 185 8 Weight: 820 g max. 110 100 90 Four, 4.5 dia. CP1L CPU Units with 40 I/O Points 150 85 140 8 Weight: 675 g max. 110 100 90 Four, 4.5 dia. CP1L CPU Units with 30 I/O Points 130 85 120 8 Weight: 610 g max. 110 100 90 Four, 4.5 dia. 28 CP1L.fm 29 ページ 2012年3月19日 月曜日 午後1時18分 CP1L CP1L CPU Units with 14 or 20 I/O Points 86 85 76 8 Weight: 380 g max. 110 100 90 Two, 4.5 dia. CP1L CPU Units with 10 I/O Points 66 85 56 8 Weight: 300 g max. 110 100 90 Two, 4.5 dia. 29 CP1L.fm 30 ページ 2012年3月19日 月曜日 午後1時18分 CP1L ■ Expansion Units and Expansion I/O Units CP1W-8E@@ CP1W-SRT21 CP1W-20ED@ CP1W-16E@@ CP1W-AD041/CP1W-DA041/CP1W-DA021 CP1W-MAD11/CP1W-TS@@@ COM 01 03 05 07 09 11 00 02 04 06 08 10 NC COM 01 00 CH IN 03 02 IN CH 00 01 02 03 04 05 06 07 CH 00 01 02 03 08 09 10 11 08 09 10 11 90 20EDR1 90 8ED OUT CH NC 00 01 02 03 04 05 06 07 CH 00 01 02 04 05 07 NC COM COM COM 03 COM 06 EXP EXP 04 COM 86 Unit name NC NC 01 00 03 02 05 04 07 06 CH 09 08 11 10 01 00 03 02 05 04 07 06 09 08 Model number 380 g 320 g CP1W-32ER 465 g CP1W-32ET/-32ET1 325 g CP1W-20EDR1/-20EDT/-20EDT1 300 g CP1W-16ER 280 g CP1W-16ET/-16ET1 225 g CP1W-8ED 200 g CP1W-8ER/-8ET/-8ET1 250 g CP1W-AD041/-DA041/-DA021 200 g CP1W-MAD11 150 g Temperature Sensor Units CP1W-TS001/-TS002/-TS101/ -TS102 250 g CompoBus/S I/O Link Unit CP1W-SRT21 200 g 11 10 CH CH IN 00 01 02 03 04 05 06 07 08 09 10 11 00 01 02 03 04 05 06 07 08 09 10 11 00 01 02 03 04 05 06 07 00 01 02 03 04 05 06 07 CH CH 110 100 90 OUT CH CH CH NC 00 01 02 04 05 07 00 02 04 05 07 NC COM COM COM 03 COM 06 COM 01 03 COM 06 40EDR Analog Units EXP Four, 4.5 dia. 30 8 50 Weight CP1W-40EDT/-40EDT1 Expansion I/O Units COM 50 CP1W-40ER 150 140 NC 07 66 50 CP1W-40ED@ CP1W-32E@@ NC 06 05 CP1L.fm 31 ページ 2012年3月19日 月曜日 午後1時18分 CP1L Related Manuals Cat. No. Model numbers Manual name Description Provides the following information on the CP Series: • Overview, design, installation, maintenance, and other basic specifications • Features • System configuration • Mounting and wiring • I/O memory allocation • Troubleshooting Use this manual together with the CP1H Programmable Controllers Programming Manual (W451). W516 CP1L-EL20D@-@ CP1L-EM30D@-@ CP1L-EM40D@-@ CP Series CP1L-EL/EM CPU Unit Operation Manual CP Series CP1L CPU Unit Operation Manual W462 CP1L-L10D@-@ CP1L-L14D@-@ CP1L-L20D@-@ CP1L-M30D@-@ CP1L-M40D@-@ CP1L-M60D@-@ CP Series CP1H/CP1L CPU Unit Programming Manual W451 CP1H-X40D@-@ CP1H-XA40D@-@ CP1H-Y20DT-D CP1L-L10D@-@ CP1L-L14D@-@ CP1L-L20D@-@ CP1L-M30D@-@ CP1L-M40D@-@ CP1L-M60D@-@ Provides the following information on programming the CP Series: • Programming methods • Tasks • Programming instructions CP Series CP1L CPU Unit Introduction Manual W461 CP1L-L10D@-@ CP1L-L14D@-@ CP1L-L20D@-@ CP1L-M30D@-@ CP1L-M40D@-@ CP1L-M60D@-@ Describes basic setup methods of CP1L PLCs: • Basic configuration and component names • Mounting and wiring • Programming, data transfer, and debugging using the CX-Programmer • Application program examples CS1G/CS1H/CS1D/CS1W/CJ2H/CJ2M/ CJ1G/CJ1H/CJ1M/CJ1W/CP1H/CP1L/ CP1E/NSJ SYSMAC CS/CJ/CP/NSJ Series Communications Commands REFERENCE MANUAL Describes the communications commands used with CS-series, CJ-series, and CP-series PLCs and NSJ Controllers. W342 SYSMAC CS/CJ/CP/NSJ Series CS1G/H-CPU@@-EV1, CS1G/H-CPU@@H, CS1D-CPU@@H, CS1D-CPU@@S, CJ1H-CPU@@H-R,CJ1G-CPU@@, CJ1M-CPU@@, CJ1G-CPU@@P, CJ1G/H-CPU@@H, CJ2H-CPU6@-EIP, CJ2H-CPU6@,CJ2M-CPU@@, CS1W-SCU@@-V1, CS1W-SCB@@-V1, CJ1W-SCU@@-V1, CP1H-X@@@@-@, CP1H-XA@@@@-@,CP1H-Y@@@@-@, CP1L-M/L@@@-@, CP1E-E@@D@-@, CP1E-N@@D@-@, NSJ@-@@@@(B)-G5D, NSJ@-@@@@(B)-M3D Communications Commands Reference Manual 31 CP1L.fm 32 ページ 2012年3月19日 月曜日 午後1時18分 MEMO 32 CP1L.fm 33 ページ 2012年3月19日 月曜日 午後1時18分 MEMO 33 CP1L.fm 34 ページ 2012年3月19日 月曜日 午後1時18分 MEMO 34 CP1L.fm 35 ページ 2012年3月19日 月曜日 午後1時18分 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. • Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. • Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. CP1L.fm 36 ページ 2012年3月26日 月曜日 午後5時13分 Note: Do not use this document to operate the Unit. OMRON Corporation Industrial Automation Company Authorized Distributor: Tokyo, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69-2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173-5302 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 © OMRON Corporation 2012 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. Printed in Japan Cat. No. P081-E1-01 0312 (-)