ETC1 EE06-FT1B6-K1000 Small size transmitter for humidity and temperature Datasheet

EE06 Series
Small Size Transmitter for Humidity
and Temperature
EE06 series are compact transmitters for humidity, and
combined humidity/temperature measurement with
excellent price / performance ratio.
They are optimised for OEM applications and available
with or without housing. With appropriate filter cap EE06
can operate successfully even in harsh environments.
The analogue output for both humidity and temperature
is 0-1 V.
The temperature output signal can be active or passive.
The very small dimensions, low energy consumption
and supply voltages down to 4.5 V allow cost-effective
and easy positioning of the transmitters.
EE06
T ypical A pplica tions
Fea tur es
very small dimensions
excellent price-performance-ratio
long term stability
easy installation
low energy consumption
humidifiers and dehumidifiers
climate controls in museums, hotels
monitoring of storage rooms
photostatic machines control
meteorological applications
Tec hnical Da ta
Measuring values
Relative humidity
Sensor
Output appropriate 0...100% RH
Working range
Accuracy at 20°C (68°F), 12V DC
Temperature dependence model F/FT
model FP
HC101
0-1 V
-0.2 mA < IL < 0.2 mA
model A
0...100% RH
model C
model B
0...95% RH
±3% RH (0...95% RH)
d RH = -0.00035 x RH x (T-20°C)
d RH = typ. (-0.003 x RH + 0.01) x (T-20°C)
0...100% RH
Temperature (active output)
Sensor
Output appropriate -40...60°C (-40...140°F)
Accuracy at 12V DC
∆°Χ
Pt1000 (class A, DIN EN 60751)
0-1 V
-0.2 mA < IL < 0.2 mA
°C
Temperature (passive output)
Type of T-Sensor
please see ordering guide
General
Supply voltage
Current consumption
Housing
Sensor protection
Electromagnetic compatibility
Temperature range
4.5V DC - 30V DC
typ. 1.5 mA
Polycarbonat / IP65 (Model A) in vertical mounting (filter cap upside)
membrane filter, plastic grid, metal grid filter
EN 61000-6-3
EN 61000-6-1
FCC Part15 ClassB
ICES-003 ClassB
working temperature: -40...60°C (-40...140°F)
storage temperature: -40...65°C (-40...149°F)
EE06
v2.2
37
Housing dimensions (mm)
1 mm = 0.03937” / 1” = 25.4 mm
Type B
Type A
2
Ø1
34
2
Ø1
Type C
34
34
82
60
2
Ø1
80
7
M10x1
cable length standard =
500mm (19.7”)
cable length standard =
200mm (7.9”)
cable length standard =
500mm (19.7”)
Connection Dia g r am
power supply
4.5...30V DC
+
+V (white)
-
GND (brown)
V
V
RH (green)
T (yellow)
power supply
4.5...30V DC
+
+V (white)
-
GND (brown)
V
W
RH (green)
Tpassive1 (yellow)
Tpassive2 (gray)
Or dering Guide
MODEL
OUTPUT T-SENSOR
humidity and temperature (FT)
humidity
(F)
humidity and temperature passive (FP)
0-1V
(only passive)
(1)
Pt 100 DIN A
Pt 100 DIN B
Pt 1000 DIN A
Pt 1000 DIN B
NTC 10K at 25°C
(A)
(B)
(C)
(D)
(E)
TYPE
FILTER
CABLE LENGTH
with housing
(A)
without housing (B)
with thread
(C)
membrane filter
plastic grid
metal grid filter
(Type A + C)
(1)
(4)
(6)
0.5m (1.6ft)
1.5m (4.9ft)
3m (9.8ft)
5m (16.4ft)
10m (32.8ft)
(no code)
(K150)
(K300)
(K500)
(K1000)
EE06-
Accessories
- radiation shield (for more information please refer to data sheet “Accessories”)
(HA010502)
Or der Example
EE06-FT1A1-K300
model:
output:
housing:
filter:
cable length
EE06
38
humidity and temperature
0-1 V
with housing
membrane filter
3m (9.8ft)
Similar pages