MACOM CDD-38-60001 Cmos ic time delay relay Datasheet

Catalog 1308242
Issued 3-03
P&B
CD series
CMOS IC Time Delay Relay
1% Repeatability
Operates from -40°C to +55°C
Delay on operate or delay on release timing modes
Fixed, knob or resistor adjustable types
– Calibrated dial on knob adjustable types
• 10A output relay with SPDT or DPDT contacts
• Various models time from 0.1 to 180 sec.
•
•
•
•
File E22575
File LR15734
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Timing Modes
Initial Dielectric Strength
Delay on operate – Delay period begins when input voltage is applied. At
the end of the delay period, the relay will operate and will not release until
input voltage is removed. Reset occurs when input voltage is reapplied.
Between Open Contacts: 500V rms, 60 Hz.
Between All Other Conductors: 500V rms, 60 Hz.
ON
OFF
N.O. RELAY
CONTACTS
ON
OFF
➛
INPUT
VOLTAGE
TIME
➛
Input Data @ 25°C
Delay on release – Input voltage must be applied continuously to operate
the internal relay. When control Input is applied, the relay energizes.
When control input is removed, timing begins. When timing is complete,
the relay will de-energize. Time may be reset to zero during timing by
reapplying control input.
ON
OFF
N.O. RELAY ON
CONTACTS OFF
➛
CONTROL
INPUT
TIME
➛
Voltage: 24 & 120VAC and 12 through 110VDC.
Power Requirement: AC Types: Typically less than 3 VA.
DC Types: Typically less than 3 W.
Transient Protection: Yes.
Reverse Voltage Protection: Yes.
Input Voltages & Limits @ 25°C
Voltage
Type
Nominal
Voltage
Minimum
Voltage
Maximum
Voltage
AC
24
120
12
24
48
110
20
105
11
20
41
95
28
130
13
32
55
125
DC
Note: DC voltage must be filtered (5% p-p ripple max. at nom. voltage).
AC models will operate on 50 or 60 Hz.
Timing Specifications
Timing Ranges: From 0.1 to 180 sec.
Timing Adjustment: Fixed, external resistor and knob adjustable.
Tolerance (for AC units add ±1/2 cycle 60 Hz.):
Knob Adj. Types: ± 5% of max. specified at high end of timing range; min.
specified, or less, at low end; ± 10% full scale.
Fixed Types:
± 5%.
Res. Adj. Types: ± 5% at high end of timing range; min. specified, or less,
at low end.
Delta Time (for AC units add ±1 cycle 60 Hz.): ± 5%.
Repeatability (for AC units add ±1 cycle 60 Hz.): ± 1%.
Release Time: 45 ms, typ.; 60 ms, max.
Recycle Time: 45 ms, typ.; 60 ms, max.
Arrangements: 2 Form C (DPDT).
Material: Silver-cadmium oxide alloy.
Rating: 10A @ 30VDC or 277VAC, resistive; 1/2 HP @ 250VAC; 1/3 HP @
120VAC.
Expected Mechanical Life: 10 million operations.
Expected Electrical Life: 100,000 operations, min., at rated load.
Dimensions are shown for
Temperature Range: Storage: -55°C to +85°C.
Operating: -40°C to +55°C.
Mechanical Data
Contact Data @ 25°C
1222 reference purposes only.
Environmental Data
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Termination: 8- or 11-pin octal style plug.
Enclosure: Yellow plastic case. Knob adjustable types have dial scale
calibrated in seconds ± 5%.
Sockets: Models with 8-pin base fit either 27E122 or 27E891 (snap-on)
screw terminal sockets. 11-pin types fit either 27E123 or
27E892 (snap-on) screw terminal sockets.
Weight: 8 oz. (227g) approximately.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Catalog 1308242
Issued 3-03
P&B
Ordering Information – Authorized distributors are more likely to stock boldface items listed below.
Delay on Operate Models
Voltage
120VAC
Time
Delay on Release Models
Adjustment
0.1 to 1 Sec.
0.1 to 5 Sec.
0.1 to 10 Sec.
0.3 to 30 Sec.
0.6 to 60 Sec.
1.8 to 180 Sec.
Wiring Dia.
Knob
Part Number
Voltage
CDB-38-70001
CDB-38-70002
CDB-38-70003
CDB-38-70006
CDB-38-70004
CDB-38-70005
1
120VAC
Time
Adjustment
0.1 to 1 Sec.
0.1 to 5 Sec.
0.1 to 10 Sec.
0.3 to 30 Sec.
0.6 to 60 Sec.
1.8 to 180 Sec.
Knob
Wiring Dia.
3
Part Number
CDB-38-70016
CDB-38-70091
CDB-38-70014
CDB-38-70092
CDB-38-70012
CDB-38-70015
120VAC
1 Sec.
Fixed
CDA-38-70012
120VAC
1 Sec.
Fixed
3
CDA-38-70025
180 Sec.
Fixed
3
CDC-38-20026
Resistor
CDF-38-70001
CDF-38-70002
CDF-38-70003
12VDC
120VAC
0.1 to 1 Sec.
0.1 to 5 Sec.
0.1 to 10 Sec.
24VDC
Knob
3
Knob
1
CDD-38-30003
CDD-38-30004
CDD-38-30005
CDD-38-30014
CDD-38-30012
CDD-38-30008
24VDC
0.1 to 10 Sec.
0.6 to 60 Sec.
1.8 to 180 Sec.
0.1 to 10 Sec.
0.6 to 60 Sec.
1.8 to 180 Sec.
48VDC
0.6 to 60 Sec.
Knob
1
CDD-38-40002
Knob
1
110VDC
0.1 to 1 Sec.
0.1 to 10 Sec.
0.6 to 60 Sec.
1.8 to 180 Sec.
2
CDD-38-60004
CDD-38-60001
CDD-38-60002
CDD-38-60003
➛
Outline Dimensions
2.406 MAX.
(61.1)
➛
2.937 MAX.
(74.6)
➛
➛
➛
➛
.56
(14.2)
➛
.60
(15.2)
1.781 MAX.
(45.2)
➛
Wiring Diagrams – Bottom Views (pins numbered clockwise from keyway)
CONTROL
INPUT* _
EXTERNAL RESISTOR
+
➛
➛
➛
➛
➛
➛
➛
➛
➛
➛
➛
➛
_
INPUT
(DC POLARITY INDICATED)**
_
INPUT
(DC POLARITY INDICATED)**
_
SUPPLY
INPUT
(DC POLARITY INDICATED)**
Fig. 1
8 Pin
Fig. 2
11 Pin
Fig. 3
11 Pin
+
+
+
* If control input is applied when supply input is applied, relay will immediately energize. A 50 millisecond minimum control pulse is required.
** Note Input polarity for DC operation. For most reliable operation on AC, connect high side to “+” and low side to “–”.
External Resistor Selection Chart
See External Resistor Selection Charts at beginning of Time Delay Relay section of this Databook.
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
1223
Refer to inside back cover.
Similar pages