DD03S/D Series
3W DC/DC CONVERTER, DIP-Package, 2:1 Wide Input Range
FEATURES
Š
Efficiency up to 81%
Š
DIP Package with Industry Standard Pinout
Š
Wide 2:1 Input Range
Š
Operating Temperature Range –40°C to +85°C
Š
Isolation Voltage 1500 VDC
Š
Short Circuit Protection
Š
Complies with EN55022,Class A
Š
Lead free, RoHs Compliant
Š
3 Years Product Warranty
The DD03S/D series are miniature, DIP Package, isolated 3W DC/DC converters with 1,500VDC isolation. The DD03S/D series
features fully regulated output and wide 2:1 input voltage ranges. It offers short circuit protection and allows a wide operating
temperature range of –40°C to +85°C.These isolated DC/DC converters are the latest offering from a world leader in power systems
technology and manufacturing ― Delta Electronics, Inc. With creative design technology and optimization of component
placement, these converters possess outstanding electrical and thermal performance, as well as extremely high reliability under
highly stressful operating conditions
Model Selection Guide
Model
Number
DD03S0505A
DD03S0512A
DD03S0515A
DDO3D0512A
DD03D0515A
DD03S1205A
DD03S1212A
DD03S1215A
DDO3D1212A
DD03D1215A
DD03S2405A
DD03S2412A
DD03S2415A
DDO3D2412A
DD03D2415A
DD03S4805A
DD03S4812A
DD03S4815A
DDO3D4812A
DD03D4815A
Input
Voltage
(Range)
Output
Voltage
VDC
VDC
5
12
15
±12
±15
5
12
15
±12
±15
5
12
15
±12
±15
5
12
15
±12
±15
5
(4.5 ~ 9)
12
(9 ~ 18)
24
(18 ~ 36)
48
(36 ~ 75)
Output
Current
Input Current
Max.
Min.
@Max. Load
@No Load
Reflected
Ripple
Current
mA
600
250
200
±125
±100
600
250
200
±125
±100
600
250
200
±125
±100
600
250
200
±125
±100
mA
60
25
20
±12.5
±10
60
25
20
±12.5
±10
60
25
20
±12.5
±10
60
25
20
±12.5
±10
mA(typ.)
857
811
811
811
811
329
313
313
313
313
162
154
154
154
154
81
77
77
77
77
mA(typ.)
mA(typ.)
40
100
Max. capacitive
Load
uF
@Max. Load
2000
1000*
2000
20
30
1000*
2000
5
15
1000*
2000
3
Efficiency
(typ.)
10
1000*
%
70
74
74
74
74
76
80
80
80
80
77
81
81
81
81
77
81
81
81
81
* For each output
DS_DD03S/D_03152012
E-mail: [email protected]
http://www.delta.com.tw/dcdc
P1
Input Characteristics
Parameter
Model
5V Input Models
12V Input Models
24V Input Models
48V Input Models
Input Surge Voltage (1 sec. max.)
5V Input Models
12V Input Models
24V Input Models
48V Input Models
5V Input Models
12V Input Models
24V Input Models
48V Input Models
Start-Up Voltage
Under Voltage Shutdown
Reverse Polarity Input Current
Short Circuit Input Power
Internal Power Dissipation
Conducted EMI
All Models
Min.
-0.7
-0.7
-0.7
-0.7
Typ.
Max.
Unit
11
--25
--50
--100
--3.5
4
4.5
4.5
7
9
VDC
8
12
18
16
24
36
--3.5
4
--6.5
8.5
--11
17
--22
34
----1
A
--1000
1500
mW
----2500
mW
Compliance to EN 55022,class A and FCC part 15,class A
Output Characteristics
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Over Load Protection
Short Circuit Protection
Conditions
Dual Output, Balanced Loads
Vin=Min. to Max.
Io=10% to 100%
Over Line, Load & Temp.
25% Load Step Change
Foldback
Min.
--------------------120
Typ.
±0.5
±0.5
±0.2
±0.2
45
----300
±3
±0.01
TBD
Continuous
Max.
±2.0
±2.0
±0.5
±0.5
60
100
15
500
±5
±0.02
---
Unit
%
%
%
%
mV P-P
mV P-P
mV rms
uS
%
%/℃
%
General Characteristics
Parameter
I/O Isolation Voltage (rated)
I/O Isolation Resistance
I/O Isolation Capacitance
Switching Frequency
MTBF (calculated)
Safety Approvals
Conditions
60 Seconds
500 VDC
100KHz, 1V
Min.
Typ.
Max.
1500
----1000
--------150
--330
--MIL-HDBK-217F@25℃, Ground Benign
1,000,000
----UL/cUL 60950-1 recognition(CSA certificate), IEC/EN 60950-1
Unit
VDC
MΩ
pF
KHz
Hours
Recommended Input Fuse
5V Input Models
1500mA Slow-Blow Type
12V Input Models
700mA Slow-Blow Type
24V Input Models
350mA Slow-Blow Type
48V Input Models
135mA Slow-Blow Type
Environmental Characteristics
Parameter
Operating Temperature Range (with
Derating)
Case Temperature
Storage Temperature Range
Humidity (non condensing)
Cooling
Lead Temperature
(1.5mm from case for 10Sec.)
DS_DD03S/D_03152012
Conditions
Ambient
Min.
-40
Max.
+85
Unit
℃
---50
---
+90
+125
95
℃
℃
% rel. H
260
℃
Free-Air convection
---
E-mail: [email protected]
http://www.delta.com.tw/dcdc
P2
Output Power (%)
Power Derating Curve
Notes
1
2
3
4
5
6
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%
Ripple & Noise measurement bandwidth is 0-20MHz.
These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not
damage these modules; however they may not meet all specifications listed.
All DC/DC converters should be externally fused at the front end for protection.
Specifications subject to change without notice.
Mechancial Drawing
Pin Connections
Pin
Single Output
1
+Vin
4.5
[0.18]
10.2
[0.40]
Mechanical Dimensions
0.50 [0.02]
3
10
11
12
Bottom View
24
23
22
15
14
20.3 [0.80]
2
15.22 [0.60]
1
13
Dual Output
+Vin
2
NC
-Vout
3
NC
Common
10
-Vout
Common
11
+Vout
+Vout
12
-Vin
-Vin
13
-Vin
-Vin
14
+Vout
+Vout
15
-Vout
Common
22
NC
Common
23
NC
-Vout
24
+Vin
+Vin
2x2.54
[2x0.10]
17.78 [0.70]
31.8 [1.25]
2x2.54
[2x0.10]
2.0
[0.08]
2.54
[0.10]
NC: No Connection
►All
dimensions in mm (inches)
►Tolerance:
X.X±0.25 (X.XX±0.01)
X.XX±0.13 ( X.XXX±0.005)
►Pin
diameter ⇔ 0.5 ±0.05 (0.02±0.002)
Physical Outline
Case Size
:
31.8x20.3x10.2mm (1.25x0.80x0.40 Inches)
Case Material
:
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)
Weight
:
12.4g
DS_DD03S/D_03152012
E-mail: [email protected]
http://www.delta.com.tw/dcdc
P3
Part Numbering System
D
D
03
S
05
05
A
Form factor
Family series
Watt
Number of
Outputs
Input Voltage
Output Voltage
Option Code
D-DIP
P-SIP
S-SMD
A~Z
01:1W
02:2W
03:3W
04:4W
06:6W
03:3.3V
05: 5V
12:12V
24: 24V
48:48V
03:3.3V
05: 5V
12:12V
15: 15V
24: 24V
A - Std. Functions
S - Single
D- Dual
WARRANTY
Delta offers a three(3) years limited warranty. Complete warranty information is listed on our web site or is available upon request from Delta.
Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its use, nor for any
infringements of patents or other rights of third parties, which may result from its use. No license is granted by implication or otherwise under
any patent or patent rights of Delta. Delta reserves the right to revise these specifications at any time, without notice.
DS_DD03S/D_03152012
E-mail: [email protected]
http://www.delta.com.tw/dcdc
P4
Similar pages