RSG ADA600F-24-C Hight power & peak power, parallel / master-slave / n1 redundant (optional), current monitor, up to 5 years warranty Datasheet

Distribution:
RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany
Tel. +49 69 984047-0 Fax +49 69 984047-77 [email protected] www.rsg-electronic.de
■
■
■
■
■
Änderungen vorbehalten / subject to change without notice
Ordering information
Unit type
ADA600F
2
F
3
-24
4
Recommended Noise Filter
NAC-20-472
R
ADA
ADA 600
1
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The Noise Filter is recommended
*to connect with several devices.
-O
5
1Series name
2Output wattage
3Universal input
4Output voltage
5Optional
G :Low leakage current
E :Low leakage current
and EMI class A
F :with Fan unit(only -24)
T :Vertical terminal block
J :Connector type
C :with Coating
R :Remote ON/OFF
N1:DIN rail
W:Alarms and Redundant
operation
Specification is changed at
option,refer to Instruction
Manual.
Please refer to derating curve, because the rated load current depends on cooling method that is convention cooling or forced air.
SPECIFICATIONS
MODEL
VOLTAGE[V]
FREQUENCY[Hz]
ACIN 100V
ACIN 200V
ACIN 100V
INPUT
POWER FACTOR
ACIN 200V
ACIN 100V *1
INRUSH CURRENT[A]
ACIN 200V *1
LEAKAGE CURRENT[mA]
VOLTAGE[V]
ACIN 100V *2
ACIN 100V *2
CURRENT[A]
ACIN 200V *2
ACIN 200V *2
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50C *3
RIPPLE[mVp-p]
OUTPUT
-10 - 0C *3
0 to +50C *3
RIPPLE NOISE[mVp-p]
-10 - 0C *3
TEMPERATURE REGULATION[mV] 0 to +50C
*4
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
PROTECTION OVERVOLTAGE PROTECTION[V]
CIRCUIT AND OPERATING INDICATION
OTHERS
ALARM OUTPUT
REMOTE ON/OFF(RC)
EFFICIENCY[%]
*5
INPUT-OUTPUT -RC
ISOLATION INPUT-FG
*5
OUTPUT-RC-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
IMPACT
AGENCY APPROVALS
SAFETY AND CONDUCTED NOISE
NOISE
REGULATIONS CE MARKING
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
OTHERS
COOLING METHOD
ADA600F-24
ADA600F-30
ADA600F-36
ADA600F-48
AC85 - 264 1f or DC 120 - 350 (AC64 or DC90 optionally available *6)
50/60 (47 - 63) or DC
84typ (Io=100%)
86typ (Io=100%)
86typ (Io=100%)
86typ (Io=100%)
86typ (Io=100%)
87typ (Io=100%)
87typ (Io=100%)
89typ (Io=100%)
0.99typ (Io=100%)
0.98typ (Io=100%)
20typ (Io=100%) (More than 3sec.to re-start)
40typ (Io=100%) (More than 3sec.to re-start)
0.75max (60Hz, According to IEC60950 and DEN-AN) (Io=100%)
24
30
36
48
14 (Peak 25) convection
11 (Peak 20) convection
9 (Peak 16.5) convection
6.5 (Peak 12.5) convection
21 (Peak 25) forced air
16.5 (Peak 20) forced air
14 (Peak 16.5) forced air
10.5 (Peak 12.5) forced air
15 (Peak 31) convection
12 (Peak 24.5) convection 10 (Peak 20.5) convection 7 (Peak 15.5) convection
25 (Peak 31) forced air
20 (Peak 24.5) forced air
16.5 (Peak 20.5) forced air 12.5 (Peak 15.5) forced air
96max
120max
144max
192max
150max
180max
240max
300max
120max
160max
200max
200max
160max
230max
260max
300max
150max
190max
230max
250max
180max
250max
280max
400max
240max
300max
360max
480max
96max
120max
144max
192max
500max (ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
21.6 - 27.0
27.0 - 33.0
33.0 - 41.0
41.0 - 52.8
23.5 - 24.5
29.0 - 31.0
35.0 - 37.0
47.0 - 49.0
Works over 101% of peak current and recovers automatically
31 - 34.5
40 - 48
51 - 60
64 - 76
LED (Green)
Detecting low input voltage(PF), detecting low output voltage(LV). (Optional : -W, refer to Instruction Manual 5)
Requirement for external source (Option : -R, refer to Instruction Manual 5)
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature)
-10 to +71C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN and IEC60950-1 (At only AC input)
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
Low Voltage Directive, EMC Directive
Complies with IEC61000-3-2
65X127X195mm (WXHXD) (without terminal block) /1.5kg max
Convection/Forced air
*1 The value is primary surge.The current of input surge to a built-in noise filter (0.2ms or less) is
excluded.
*2 Peak loading for 10sec.And Duty 35% max.Refer to Instruction Manual 4.Forced air is shown
in Instruction Manual 2.3.
*3 This is the value that measured on measuring board with capacitor of 22mF within 150mm
from output terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to
A-120
KEISOKU-GIKEN: RM101).
*4 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,
with the input voltage held constant at the rated input/output.
*5 Applicable when remote control (optional) is added.
*6 Derating is required.Consult us for details.
* A sound may occur from power supply at pulse loading.
ADA600F
Block diagram
Fuse
250V12A
ADA
Booster inductor
Noise
filter
AC IN 85 - 264V
Inrush
current
limitting
Detecting
current
Rectifier
Rectifier
&
Smooth
FG
Inverter
Option
Alarm
circuit
PF alarm
(-W)
Detecting
current
Control
Option
RC
(-R)
N+1
Redundancy
Control
External source
(-W)
Control
Current Balance (CB)
Master-Slave
circuit
Over voltage
protection
Voltage Balance (VB)
Inverter
Option
Detecting
output voltage
LV alarm (-W)
Rectifier
&
Smooth
DC OUT
External view
18.1 13
(22.6)
16.2
Voltage adjust
CN3(Option)
(19)
LED
4-M4
Mounting hole
(Bottom)
195
6.6
Name plate
TB1
29
105 ±0.5
127
9 8
8.6
10
M3.5
FG hole
2-M4
Mounting hole
130.5 ±0.5
48
130.5 ±0.5
48
9
29±0.5 26.5
65
2-M4
Mounting hole
Terminal cover
20
35 ±0.5
18
11
9
27.5
114.5
VB
CB
+V
+V
-V
-V
FG
N
L
8-M4
Mounting hole
(Both sides)
¶ Pin assign
Symbol
VB
CB
+V
+V
-V
-V
FG
N
L
CN3(Option)
Function
Voltage balance
Current balance
Output terminal(+)
Output terminal(+)
Output terminal(-)
Output terminal(-)
Frame ground
AC(N)
AC(L)
Screw type
Pin No.
M3
2 1
4 3
6 5
8 7
10 9
12 11
14 13
M4
Average 21A max per pin for TB1
1
RC+
Function
: Remote ON/OFF+(-R)
2
RC-
: Remote ON/OFF-(-R)
3-8
NC
: N.C.
9
LV+
: LV Alarm(-W)
10
LV-
: LV Alarm ground(-W)
11-12
NC
: N.C.
13
PF+
: PF Alarm(-W)
14
PF-
: PF Alarm ground(-W)
Connector
Mating connector
Terminal
Chain:SPHD-002T-P0.5
PHDR-14VS Loose:BPHD-001T-P0.5
BPHD-002T-P0.5 *1
*1 Ratchet Hand is nothing
CN3 S14B-PHDSS
Mfr.
J.S.T
¶ Tolerance : ±1
¶ Weight : 1.5kg max
¶ PCB material / thickness : FR-4 / 1.6mm
¶ Chassis and cover material : aluminium
¶ Dimensions in mm
¶ Mounting torque : 1.2N • m(12.8kgf • cm) max
¶ Screw tighting torque
M4 : 1.6N • m(16.9kgf • cm) max , M3 : 0.8N • m(8.5kgf • cm) max
¶ I/0 terminal for option-J and -T is shown in Instruction Manual 5.
Distribution:
RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany
Tel. +49 69 984047-0 Fax +49 69 984047-77 [email protected] www.rsg-electronic.de
■
■
Änderungen vorbehalten / subject to change without notice
■
■
■
A-121