AIMTEC AM30EW-240315TZ 30 watt | dc-dc converter Datasheet

Click on Series name for product info on aimtec.com
Series AM30EW-Z
30 Watt | DC-DC Converter
FEATURES:








Ultra Wide 4:1 input range
Efficiency up to 91%
Soft start
Continuous short circuit protection
Remote on/off control
Input/Output Isolation 1600VDC
Operating temperature -40ºC to + 75ºC
RoHS compliant
Models
Single output
Model
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (A)
Maximum
Capacitive Load
(uF)
Efficiency
(%)
3.3
5
5.1
12
15
3.3
5
5.1
12
15
7.5
6
6
2.5
2
7.5
6
6
2.5
2
20000
14000
14000
2000
2000
20000
14000
14000
2000
2000
86
88
88
89
89
86
88
88
90
91
Output Voltage
(V)
Output Current
max (A)
Maximum
Capacitive Load
(uF)
Efficiency
(%)
±5
±12
±15
±5
±12
±15
±3
±1.25
±1
±3
±1.25
±1
±3000
±1300
±1300
±3000
±1300
±1300
88
87
87
88
88
88
AM30EW-2403SZ
9-36
AM30EW-2405SZ
9-36
AM30EW-2405.1SZ
9-36
AM30EW-2412SZ
9-36
AM30EW-2415SZ
9-36
AM30EW-4803SZ
18-75
AM30EW-4805SZ
18-75
AM30EW-4805.1SZ
18-75
AM30EW-4812SZ
18-75
AM30EW-4815SZ
18-75
Add suffix “-K” for optional heat sink
Models
Dual output
Model
Input Voltage
(V)
AM30EW-2405DZ
9-36
AM30EW-2412DZ
9-36
AM30EW-2415DZ
9-36
AM30EW-4805DZ
18-75
AM30EW-4812DZ
18-75
AM30EW-4815DZ
18-75
Add suffix “-K” for optional heat sink
Models
Triple output
Model
Input
Voltage (V)
AM30EW-240312TZ
9-36
AM30EW-240315TZ
9-36
AM30EW-240512TZ
9-36
AM30EW-240515TZ
9-36
AM30EW-480312TZ
18-75
AM30EW-480315TZ
18-75
AM30EW-480512TZ
18-75
AM30EW-480515TZ
18-75
Add suffix “-K” for optional heat sink
Output
Voltage (V)
Output
Auxiliary
Voltage (V)
Output Current
max (A)
Maximum
Capacitive
Load (uF)
Efficiency
(%)
3.3
3.3
5
5
3.3
3.3
5
5
±12
±15
±12
±15
±12
±15
±12
±15
5 / ±0.42
5 / ±0.33
4 / ±0.42
4 / ±0.33
5 / ±0.42
5 / ±0.33
4 / ±0.42
4 / ±0.33
15000 / ±220
15000 / ±220
8000 / ±220
8000 / ±220
15000 / ±220
15000 / ±220
8000 / ±220
8000 / ±220
88
88
90
90
88
88
90
90
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
www.aimtec.com
F 051e R11.K
Tel: +1 514 620 2722
1 of 7
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM30EW-Z
30 Watt | DC-DC Converter
Input Specifications
Parameters
Voltage range
Nominal
24
48
Filter
Start up time
Absolute Maximum Rating
24
48
Peak Input Voltage time
On/Off control
No Load Input Current
Under voltage lockout
Vin 9~36
Vin 36~75
24V ON/OFF
48V ON/OFF
Input reflected current
Typical
Maximum
Units
9-36
36-75
π (Pi) Network
30
-0.7 ~ 50
-0.7 ~ 100
VDC
ms
VDC
100
ON: 3 ~12VDC or open circuit
OFF: 0 ~ 1.2VDC or Short circuit between pin 2 and pin 3
100
50
8.8 / 7.9
17.8 / 16
20
ms
mA
VDC
mAp-p
Isolation Specifications
Parameters
Tested I/O voltage
Case/Input tested voltage
Resistance
Capacitance
Conditions
3 sec
3 sec
Typical
Rated
Units
1600
VDC
VDC
MOhm
pF
1600
1000
1500
Output Specifications
Parameters
Voltage accuracy (Single and Dual)
Voltage accuracy (Triple)
Cross Regulation (Dual Output Models)
Cross Regulation (Triple)
Over voltage protection
Over current protection
Short Circuit protection
Short circuit restart
Thermal Shutdown
Line voltage regulation (Single)
Line voltage regulation (Dual)
Line voltage regulation (Triple)
Load voltage regulation (Single)
Load voltage regulation (Dual)
Load voltage regulation (Triple)
Temperature coefficient
Ripple & Noise (Single and Dual)
Ripple & Noise (Triple)
Voltage adjustment range (single)
Minimum Load Current
www.aimtec.com
F 051e R11.K
Conditions
Typical
±1
±1 / ±5
±5
Main / Auxiliary
25% load on one output - 100% load on
second load
Main 100%, 25% load on Aux1 and 100%
±5
on Aux2
Zener diode clamp
120
Continuous
Auto-Recovery
Case temp
115
HL-LL
±0.2
HL-LL
±0.2
HL-LL Main / Auxiliary
±1 / ±5
0-100% load
±0.5
Balanced load
±1
10~100% Main / Auxiliary
±1 / ±5
±0.02
100
20MHz bandwidth, 3.3V/5V/5.1V/±5V
150
20MHz bandwidth, 12V/15V/±12V/±15V
20MHz bandwidth Main / Auxiliary
50 / 75
±10
10
Tel: +1 514 620 2722
2 of 7
Maximum
Units
%
%
%
o
C
%
%
%
%
%
%
%/oC
mV p-p
mV p-p
%
% of Max
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM30EW-Z
30 Watt | DC-DC Converter
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Derating
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
Conditions
Typical
100% load
Derating above 50
330
Maximum
-40 to +75
-40 to +125
105
2
Free Air Convection
MTBF
Maximum soldering temperature
Transient recovery time
Transient recovery deviation
Units
KHz
o
C
o
C
o
C
%/ oC
95
% RH
Nickel coated Copper
30
g
2.00 x 1.00 x 0.4 inches
50.80 x 25.40 x 10.17 mm
Single & Dual: >450000 hrs (MIL-HDBK -217F, Ground Benign, t=+25ºC)
Triple: >320000 hrs (MIL-HDBK -217F, Ground Benign, t=+25ºC)
o
1.5mm from case for 10 sec
260
C
250
uS
±3
%
Safety Specifications
Parameters
Agency Approval
Standards
CE
EN55022 Class A, EN55024
IEC61000-4-2, Perf. Criteria B
IEC61000-4-3, Perf. Criteria A
IEC61000-4-4, Perf. Criteria B (external 220uF/100V cap required)
IEC61000-4-5, Perf. Criteria B (external 220uF/100V cap required)
IEC61000-4-6, Perf. Criteria A
IEC61000-4-8, Perf. Criteria A
Pin Out Specifications
Pin
1
2
3
4
5
6
7
Single
+ V Input
- V Input
On/Off Control
+ V Output
-V Output
Trim
No Pin
www.aimtec.com
F 051e R11.K
Dual
+ V Input
- V Input
On/Off Control
+ V Output
Common
- V Output
No Pin
Triple
+ V Input
- V Input
On/Off Control
+ Vaux Output
- Vaux Output
Common
+ V Output
Tel: +1 514 620 2722
3 of 7
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM30EW-Z
30 Watt | DC-DC Converter
Dimensions
4
5
Bottom View
3
6
10.16
(0.40)
2.54
(0.10)
2.54
(0.10)
Notes:
All dimensions are typical in millimeters (inches).
Pin Pitch Tolerance ±0.35 (±0.014)
Case Tolerance ±0.50 (±0.02)
5.08
(0.20)
Diameter 1.00
(0.04)
10.16
(0.40)
25.40
(1.00)
1
2
10.16
(0.40)
2.54
(0.10)
10.16
(0.40)
50.80
(2.00)
5.08
(0.20)
5.08
(0.20)
Single and Dual Output Models
25.40
(1.00)
5.08
(0.20)
10.16
(0.40)
7.64
(0.30)
5
Bottom View
6
3
2.54
(0.10)
7.64
(0.30)
4
1
2
5.08
(0.20)
2.54
(0.10)
5.08
(0.20)
5.08
(0.20)
50.80
(2.00)
10.16
(0.40)
Triple Output Models
7
2.54
(0.10)
Notes:
All dimensions are typical in millimeters (inches).
Pin Pitch Tolerance ±0.35 (±0.014)
Case Tolerance ±0.50 (±0.02)
Dimensions with Optional Heat Sink
50.8
(2.0)
SIDE
25.4
(1.0)
16.3
(0.64)
END
Notes: Add “-K” suffix for ordering, heat sink is affixed with thermally dissipative adhesive tape.
See derating graph for temperature performance. Heat sink material is anodized (black) aluminum, adds weight 11.2g to
total mass (41.2g). Thermal impedance of converter is: with heat sink 10Ԩ/W and 12Ԩ/W without heat sink
www.aimtec.com
F 051e R11.K
Tel: +1 514 620 2722
4 of 7
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM30EW-Z
30 Watt | DC-DC Converter
Derating
Free Air Convection
50 ºC
100
60 ºC
Output Power %
Heatsink
80
60
Safe Operating Area
40
20
0
-40
-25
0
20
40
50
60
75
80
100
Ambient Temperature º C
Extended temperature performance can be achieved with optional heat sink. (add suffix “–K” to part number)
Trimming
On/Off Control
Positive logic turns on the module during high logic and off during low logic.
Module can be controlled by an external switch between the On/Off CTRL terminal and –Vinput terminal. The switch can be
either open collector or open drain.
www.aimtec.com
F 051e R11.K
Tel: +1 514 620 2722
5 of 7
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM30EW-Z
30 Watt | DC-DC Converter
Recommended Circuits
C1
100uF, 100V
L
12uH
C2
1206, 470pF, 2KV
Conducted/Radiated Emissions
Single Output
L
+V output
+V input
C1
DC/DC
Converter
-V input
Load
-V output
C2
Conducted/Radiated Emissions
Dual Output
+V output
L
+V input
C1
DC/DC
Converter
Load
-V output
-V input
Load
Common
C2
Conducted/Radiated Emissions
Triple Output
L
+V input
C1
Load
+Vaux
Output
DC/DC
Converter
-Vaux
Output
+V output
-V input
Load
Load
Common
C2
www.aimtec.com
F 051e R11.K
Tel: +1 514 620 2722
6 of 7
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM30EW-Z
30 Watt | DC-DC Converter
Surge/EFT
C1
220uF, 100V
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R11.K
Tel: +1 514 620 2722
7 of 7
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only