Click on Series name for product info on aimtec.com Series AM30EW-Z 30 Watt | DC-DC Converter FEATURES: Ultra Wide 4:1 input range Efficiency up to 91% Soft start Continuous short circuit protection Remote on/off control Input/Output Isolation 1600VDC Operating temperature -40ºC to + 75ºC RoHS compliant Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (A) Maximum Capacitive Load (uF) Efficiency (%) 3.3 5 5.1 12 15 3.3 5 5.1 12 15 7.5 6 6 2.5 2 7.5 6 6 2.5 2 20000 14000 14000 2000 2000 20000 14000 14000 2000 2000 86 88 88 89 89 86 88 88 90 91 Output Voltage (V) Output Current max (A) Maximum Capacitive Load (uF) Efficiency (%) ±5 ±12 ±15 ±5 ±12 ±15 ±3 ±1.25 ±1 ±3 ±1.25 ±1 ±3000 ±1300 ±1300 ±3000 ±1300 ±1300 88 87 87 88 88 88 AM30EW-2403SZ 9-36 AM30EW-2405SZ 9-36 AM30EW-2405.1SZ 9-36 AM30EW-2412SZ 9-36 AM30EW-2415SZ 9-36 AM30EW-4803SZ 18-75 AM30EW-4805SZ 18-75 AM30EW-4805.1SZ 18-75 AM30EW-4812SZ 18-75 AM30EW-4815SZ 18-75 Add suffix “-K” for optional heat sink Models Dual output Model Input Voltage (V) AM30EW-2405DZ 9-36 AM30EW-2412DZ 9-36 AM30EW-2415DZ 9-36 AM30EW-4805DZ 18-75 AM30EW-4812DZ 18-75 AM30EW-4815DZ 18-75 Add suffix “-K” for optional heat sink Models Triple output Model Input Voltage (V) AM30EW-240312TZ 9-36 AM30EW-240315TZ 9-36 AM30EW-240512TZ 9-36 AM30EW-240515TZ 9-36 AM30EW-480312TZ 18-75 AM30EW-480315TZ 18-75 AM30EW-480512TZ 18-75 AM30EW-480515TZ 18-75 Add suffix “-K” for optional heat sink Output Voltage (V) Output Auxiliary Voltage (V) Output Current max (A) Maximum Capacitive Load (uF) Efficiency (%) 3.3 3.3 5 5 3.3 3.3 5 5 ±12 ±15 ±12 ±15 ±12 ±15 ±12 ±15 5 / ±0.42 5 / ±0.33 4 / ±0.42 4 / ±0.33 5 / ±0.42 5 / ±0.33 4 / ±0.42 4 / ±0.33 15000 / ±220 15000 / ±220 8000 / ±220 8000 / ±220 15000 / ±220 15000 / ±220 8000 / ±220 8000 / ±220 88 88 90 90 88 88 90 90 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. www.aimtec.com F 051e R11.K Tel: +1 514 620 2722 1 of 7 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30EW-Z 30 Watt | DC-DC Converter Input Specifications Parameters Voltage range Nominal 24 48 Filter Start up time Absolute Maximum Rating 24 48 Peak Input Voltage time On/Off control No Load Input Current Under voltage lockout Vin 9~36 Vin 36~75 24V ON/OFF 48V ON/OFF Input reflected current Typical Maximum Units 9-36 36-75 π (Pi) Network 30 -0.7 ~ 50 -0.7 ~ 100 VDC ms VDC 100 ON: 3 ~12VDC or open circuit OFF: 0 ~ 1.2VDC or Short circuit between pin 2 and pin 3 100 50 8.8 / 7.9 17.8 / 16 20 ms mA VDC mAp-p Isolation Specifications Parameters Tested I/O voltage Case/Input tested voltage Resistance Capacitance Conditions 3 sec 3 sec Typical Rated Units 1600 VDC VDC MOhm pF 1600 1000 1500 Output Specifications Parameters Voltage accuracy (Single and Dual) Voltage accuracy (Triple) Cross Regulation (Dual Output Models) Cross Regulation (Triple) Over voltage protection Over current protection Short Circuit protection Short circuit restart Thermal Shutdown Line voltage regulation (Single) Line voltage regulation (Dual) Line voltage regulation (Triple) Load voltage regulation (Single) Load voltage regulation (Dual) Load voltage regulation (Triple) Temperature coefficient Ripple & Noise (Single and Dual) Ripple & Noise (Triple) Voltage adjustment range (single) Minimum Load Current www.aimtec.com F 051e R11.K Conditions Typical ±1 ±1 / ±5 ±5 Main / Auxiliary 25% load on one output - 100% load on second load Main 100%, 25% load on Aux1 and 100% ±5 on Aux2 Zener diode clamp 120 Continuous Auto-Recovery Case temp 115 HL-LL ±0.2 HL-LL ±0.2 HL-LL Main / Auxiliary ±1 / ±5 0-100% load ±0.5 Balanced load ±1 10~100% Main / Auxiliary ±1 / ±5 ±0.02 100 20MHz bandwidth, 3.3V/5V/5.1V/±5V 150 20MHz bandwidth, 12V/15V/±12V/±15V 20MHz bandwidth Main / Auxiliary 50 / 75 ±10 10 Tel: +1 514 620 2722 2 of 7 Maximum Units % % % o C % % % % % % %/oC mV p-p mV p-p % % of Max Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30EW-Z 30 Watt | DC-DC Converter General Specifications Parameters Switching frequency Operating temperature Storage temperature Maximum case temperature Derating Cooling Humidity Case material Weight Dimensions (L x W x H) Conditions Typical 100% load Derating above 50 330 Maximum -40 to +75 -40 to +125 105 2 Free Air Convection MTBF Maximum soldering temperature Transient recovery time Transient recovery deviation Units KHz o C o C o C %/ oC 95 % RH Nickel coated Copper 30 g 2.00 x 1.00 x 0.4 inches 50.80 x 25.40 x 10.17 mm Single & Dual: >450000 hrs (MIL-HDBK -217F, Ground Benign, t=+25ºC) Triple: >320000 hrs (MIL-HDBK -217F, Ground Benign, t=+25ºC) o 1.5mm from case for 10 sec 260 C 250 uS ±3 % Safety Specifications Parameters Agency Approval Standards CE EN55022 Class A, EN55024 IEC61000-4-2, Perf. Criteria B IEC61000-4-3, Perf. Criteria A IEC61000-4-4, Perf. Criteria B (external 220uF/100V cap required) IEC61000-4-5, Perf. Criteria B (external 220uF/100V cap required) IEC61000-4-6, Perf. Criteria A IEC61000-4-8, Perf. Criteria A Pin Out Specifications Pin 1 2 3 4 5 6 7 Single + V Input - V Input On/Off Control + V Output -V Output Trim No Pin www.aimtec.com F 051e R11.K Dual + V Input - V Input On/Off Control + V Output Common - V Output No Pin Triple + V Input - V Input On/Off Control + Vaux Output - Vaux Output Common + V Output Tel: +1 514 620 2722 3 of 7 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30EW-Z 30 Watt | DC-DC Converter Dimensions 4 5 Bottom View 3 6 10.16 (0.40) 2.54 (0.10) 2.54 (0.10) Notes: All dimensions are typical in millimeters (inches). Pin Pitch Tolerance ±0.35 (±0.014) Case Tolerance ±0.50 (±0.02) 5.08 (0.20) Diameter 1.00 (0.04) 10.16 (0.40) 25.40 (1.00) 1 2 10.16 (0.40) 2.54 (0.10) 10.16 (0.40) 50.80 (2.00) 5.08 (0.20) 5.08 (0.20) Single and Dual Output Models 25.40 (1.00) 5.08 (0.20) 10.16 (0.40) 7.64 (0.30) 5 Bottom View 6 3 2.54 (0.10) 7.64 (0.30) 4 1 2 5.08 (0.20) 2.54 (0.10) 5.08 (0.20) 5.08 (0.20) 50.80 (2.00) 10.16 (0.40) Triple Output Models 7 2.54 (0.10) Notes: All dimensions are typical in millimeters (inches). Pin Pitch Tolerance ±0.35 (±0.014) Case Tolerance ±0.50 (±0.02) Dimensions with Optional Heat Sink 50.8 (2.0) SIDE 25.4 (1.0) 16.3 (0.64) END Notes: Add “-K” suffix for ordering, heat sink is affixed with thermally dissipative adhesive tape. See derating graph for temperature performance. Heat sink material is anodized (black) aluminum, adds weight 11.2g to total mass (41.2g). Thermal impedance of converter is: with heat sink 10Ԩ/W and 12Ԩ/W without heat sink www.aimtec.com F 051e R11.K Tel: +1 514 620 2722 4 of 7 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30EW-Z 30 Watt | DC-DC Converter Derating Free Air Convection 50 ºC 100 60 ºC Output Power % Heatsink 80 60 Safe Operating Area 40 20 0 -40 -25 0 20 40 50 60 75 80 100 Ambient Temperature º C Extended temperature performance can be achieved with optional heat sink. (add suffix “–K” to part number) Trimming On/Off Control Positive logic turns on the module during high logic and off during low logic. Module can be controlled by an external switch between the On/Off CTRL terminal and –Vinput terminal. The switch can be either open collector or open drain. www.aimtec.com F 051e R11.K Tel: +1 514 620 2722 5 of 7 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30EW-Z 30 Watt | DC-DC Converter Recommended Circuits C1 100uF, 100V L 12uH C2 1206, 470pF, 2KV Conducted/Radiated Emissions Single Output L +V output +V input C1 DC/DC Converter -V input Load -V output C2 Conducted/Radiated Emissions Dual Output +V output L +V input C1 DC/DC Converter Load -V output -V input Load Common C2 Conducted/Radiated Emissions Triple Output L +V input C1 Load +Vaux Output DC/DC Converter -Vaux Output +V output -V input Load Load Common C2 www.aimtec.com F 051e R11.K Tel: +1 514 620 2722 6 of 7 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30EW-Z 30 Watt | DC-DC Converter Surge/EFT C1 220uF, 100V NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R11.K Tel: +1 514 620 2722 7 of 7 Toll free: + 1 888 9 AIMTEC (924 6832) North America only