The ABC150 Series of open-frame power supplies, with its wide universal 90 - 264 VAC input range and high power density, is available at 150 W of output power and a variety of single output voltages. The high efficiency and high power density of the ABC family ensures minimal power loss in end-use equipment, thereby facilitating higher reliability, easier thermal management and meets regulatory approvals for environmentally-friendly end products. These power supplies are ideal for telecom, datacom, industrial equipment and other applications. • 4 x 2 x 1.3 Inch Form Factor • 150 W with Forced-Air Cooling • 12 V @ 0.5 A fan voltage auxiliary output • High Efficiency > 86% Low conducted and radiated noise • Light weight • IEC Protection Class Options: • Class I: Earthing Tab J4 (no suffix) • Class II: No Earthing Tab (-2 suffix) • Cover Kit Accessory Available • RoHS Compliant • Instrumentation • Renewable Energy • Lighting • Test and Measurement • Industrial Applications • Robotics • Applied Computing • Wireless Communication ABC150 Series 2 MODEL1 5 VDC MAX LOAD CONVECTION 2 16.0 A MAX LOAD 300 LFM 2,3, 4 16.0 A Screw Terminal 5 VDC 16.0 A JST 12 VDC 8.33 A CONNECTOR OUTPUT VOLTAGE ABC150-1005G JST ABC150-1T05G ABC150-1012G 0.0 A RIPPLE & NOISE5 1% 20.0 A 0.0 A 1% 12.5 A 0.0 A 1% 1% MINIMUM LOAD ABC150-1T12G Screw Terminal 12 VDC 8.33 A 12.5 A 0.0 A ABC150-1015G JST 15 VDC 6.67 A 10.0 A 0.0 A 1% 1% ABC150-1T15G Screw Terminal 15 VDC 6.67 A 10.0 A 0.0 A ABC150-1024G JST 24 VDC 4.17 A 6.25 A 0.0 A 1% 6.25 A 0.0 A 1% 1% 1% ABC150-1T24G Screw Terminal 24 VDC 4.17 A ABC150-1048G JST 48 VDC 2.08 A 3.13 A 0.0 A ABC150-1T48G Screw Terminal 48 VDC 2.08 A 3.13 A 0.0 A COVER-201-XBC 6 Metal cover kit accessory Specifications are for nominal input voltage, 25°C unless otherwise stated. PARAMETER DESCRIPTION / CONDITION SPECIFICATION Input Voltage Universal 90-264 VAC / 120-390 VDC Input Frequency Input Current 47 to 63 Hz 120 VAC: 230 VAC: No Load Power Inrush Current Leakage Current Power Factor Switching Frequency 1.7 A max. 0.85 A max. 1.2 W 120 VAC: 230 VAC: 120 VAC: 230 VAC: 120 VAC: 230 VAC: PFC converter (variable) Resonant converter (variable) 35 A max. 65 A max. < 150 µA < 300 µA 0.99 0.95 35 - 250 kHz, 90 kHz typical 35 - 250 kHz, 90 kHz typical 1 For Class II (without input Earth pin) add suffix -2 (e.g.: ABC150-1012G-2). Combined output power from V1, VSTBY and VFAN should not exceed the total output power rating. 3 Fan output voltage tolerance is +/-20%. 4 Peak current for fan output is 1 A. 5 Ripple is 2% up to 20% load and < 1% above 20% load. Ripple is peak to peak with 20 MHz bandwidth and 10 µF (Tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. 6 When used in Cover Kit, de-rate output power to 70 % under all operating conditions. 2 [email protected] ABC150 Series PARAMETER Output Power Efficiency Hold Up Time 3 DESCRIPTION / CONDITION SPECIFICATION Derate output power linearly to 80% from 90 VAC to 80 VAC input Peak Power 170 W for 0.2 s 120 VAC: 230 VAC: 120 VAC: 230 VAC: 150 W Line Regulation Load Regulation 84% typical 86% typical 6 ms 10 ms +/-0.5% Main output 50 to 100% load change, 50 Hz, 50% duty cycle, 0.1A / µs +/-2.0% < 10%, recovery time < 5 ms < 100 ms Set Point Accuracy Main output ± 1% Voltage Adjustment V1 ±3% Transient Response Rise Time Over Current Protection 110% typical above rating Over Voltage Protection V1 110 to 150% Short Circuit Protection Short term, Automatic recovery PARAMETER DESCRIPTION / CONDITION SPECIFICATION Operating Temperature Refer to derating curves Start-up is guaranteed -20 to 70°C -20 to 0°C -40 to 70° C 80 W 100 W 100 W 150 W 95% 10,000 ft. 40,000 ft. 2.4 million hours Storage Temperature 5 V model Cooling Other models Humidity Altitude Reliability Convection: 300 LFM: Convection: 300 LFM: Non Condensing Operating: Non-Operating: MTBF according to Telcordia -SR332-Issue 3 Conducted Emissions EN55032-B, CISPR22-B, FCC PART15-B Pass Radiated Emissions EN 55032 A; with external core (King core K5B RC 25x12x15-M in input cable) Pass Level B Input Current Harmonics EN 61000-3-2 Class D Voltage Fluctuation and Flicker EN 61000-3-3 Pass ESD Immunity EN 61000-4-2 Level 3, Criterion A Radiated Field Immunity EN 61000-4-3 Level 3, Criterion A Electrical Fast Transient Immunity EN 61000-4-4 Level 3, Criterion A Surge Immunity EN 61000-4-5 Level 3, Criterion A Conducted Immunity EN 61000-4-6 Level 3, Criterion A Magnetic Field Immunity EN 61000-4-8 Level 3, Criterion A Voltage Dips, Interruptions EN 61000-4-11 Criterion A & B Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2017 Bel Power Solutions & Protection BCD.00283_AE Asia-Pacific +86 755 298 85888 ABC150 Series 4 PARAMETER DESCRIPTION / CONDITION SPECIFICATION Isolation Voltage Min. 4242 VDC Agency Approvals Input to Output: Approved to the latest edition of the following standards: CSA/UL60950-1, EN60950-1 and IEC60950-1 Nemko, UL, C-UL CE mark Complies with LVD Directive Safety Standards CONNECTOR AC Input Connector PIN J1 DESCRIPTION / CONDITION Pin 1 AC Line Pin 2 AC Neutral DC Output Connector J2 Pin 1,2 Pin 3,4 V1 RTN Fan J3 Pin 1 Pin 2 VFAN (12 V / 0.5 A) RTN Earthing Tab J4 PARAMETER DESCRIPTION / CONDITION Weight 150 g (0.33 lbs.) Dimensions 101.6 x 50.8 x 33.6 mm (4.0 x 2.0 x 1.3 inch) MANUFACTURER / PN Molex: 26-60-4030 or equivalent Mating: 09-50-3031; Pins: 08-50-0106 Option-1: Tyco: 1776112-4 or equivalent Mating: 13 AWG wire Option-2: JST: B4P-VH-B (LF) (SN) or B4P-VH (LF) (SN) or equivalent Mating: VHR-4M; Pins: SVH-41T-P1.1 Tyco: 640456-2 or equivalent Mating: 640440-2 Molex: 19705-4301 or equivalent Mating: 190030001 Figure 1 - Mechanical Drawing [email protected] ABC150 Series 5 NOTES: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following: 1 Stand off, used to mount PCB has OD of 5.4 mm max. 2 Screws, used to fix PCB on stand off, have head dia of 6.0 mm max. 3 Washer, if used, to have dia of 6.5 mm max. Convection load: 80 W up to 50 °C De-rate above 50 °C @ 3.125% per °C Forced air cooled load: 100W up to 50°C De-rate above 50 °C @ 2.5% per °C Convection load: 100 W up to 50 °C De-rate above 50 °C @ 2.5% per °C Forced air cooled load : 150 W up to 50°C De-rate above 50 °C @ 1.67% per °C Figure 2. Derating Curves NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2017 Bel Power Solutions & Protection BCD.00283_AE Asia-Pacific +86 755 298 85888