Click on Series name for product info on aimtec.com Series AME20-CJZ 20 Watt | AC-DC / DC-DC Converter Picture coming soon FEATURES: I/O Isolation 3000VAC Operating Temp: -25 °C to +70 °C Input: 85-264VAC, 47-63Hz, or 120-370VDC Over current, Over Voltage Protection Continuous Short circuit protection Energy Star compliant Compact package Efficiency up to 85% Models Single output Model AME20-5SCJZ AME20-9SCJZ AME20-12SCJZ AME20-15SCJZ AME20-24SCJZ Input Voltage (VAC/Hz) Input Voltage (VDC) Output Voltage (V) 85-264/47-63 85-264/47-63 85-264/47-63 85-264/47-63 85-264/47-63 120-370 120-370 120-370 120-370 120-370 5 9 12 15 24 Input Voltage (VAC/Hz) Input Voltage (VDC) Output Voltage (V) 85-264/47-63 85-264/47-63 85-264/47-63 120-370 120-370 120-370 Output Current max (A) 3.5 2.1 1.6 1.3 0.85 Maximum capacitive Load (µF) Efficiency 230VAC (%) 12240 7200 5400 2720 1840 75 77 81 83 85 Maximum capacitive Load (µF) Efficiency 230VAC (%) ±8000 ±960 ±880 75 82 83 Models Dual output Model AME20-5DCJZ AME20-12DCJZ AME20-15DCJZ ±5 ±12 ±15 Output Current max (A) ±2 ±0.83 ±0.65 Models Triple output Model Input Voltage (VAC/Hz) Input Voltage (VDC) Output Voltage (V) Auxiliary Output Voltage (V) Output Current max (A) Maximum capacitive Load (µF) Efficiency 230VAC (%) AME20-505TCJZ AME20-512TCJZ AME20-515TCJZ AME20-524TCJZ 85-264/47-63 85-264/47-63 85-264/47-63 85-264/47-63 120-370 120-370 120-370 120-370 5 5 5 5 ±5 ±12 ±15 ±24 2.5/±0.5 2/±0.4 2/±0.3 2/±0.2 11200/±4480 16000/±1600 13520/±370 11200/±370 74 75 76 77 Models Asymmetric Separated Dual output Model AME20-512DCJZ AME20-515DCJZ AME20-524DCJZ www.aimtec.com Input Voltage (VAC/Hz) Input Voltage (VDC) 85-264/47-63 85-264/47-63 85-264/47-63 120-370 120-370 120-370 Output Voltage (V) 5/12 5/15 5/24 Tel: +1 514 620 2722 Output Current max (A) 2.5/0.6 2.5/0.5 2.5/0.3 Maximum capacitive Load (µF) Efficiency 230VAC (%) 32400/3250 28000/1980 28000/720 75 76 77 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.A 1 of 7 North America only Series AME20-CJZ 20 Watt | AC-DC / DC-DC Converter Input Specifications Parameters Current (full load) Inrush current <2ms (cold start) Leakage current External fuse Conditions Typical 115 VAC 230 VAC 115 VAC 230 VAC 230VAC/50Hz Recommended slow blow type 16 30 3.15 Maximum 600 340 Units mA mA A A mA A 0.3 Output Specifications Parameters Conditions Typical Voltage accuracy Line regulation Load regulation (single output) Load Regulation (dual output) Load Regulation (triple & asymmetric separated output) Minimum load Full load, main output Full load, auxiliary output 10-100% load 10-100% Balanced load 10-100% Balanced load, main output 10-100% Balanced load, auxiliary output Single output Others Ripple & Noise * 115VAC, 20MHz bandwidth 230VAC, 20MHz bandwidth Hold-up time ±2 ±0.5 ±1.5 ±1 ±2 ±3 ±5 0 10 50 15 80 Voltage adjustment range Maximum Units % % % % % ±10 % % mV p-p ms ms % of Vout Rated Units 3000 500 VAC VDC 150 Isolation Specifications Parameters Conditions Tested I/O voltage Isolation voltage between Main and Auxiliary output Isolation Resistance Typical 60 sec 60 sec >1000 MΩ General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 65 KHz Protection class Class I Over current protection ≥110 % of Iout Over voltage protection Zener diode clamp Short circuit protection Continuous, Auto recovery oC Operating temperature See derating curve -25 to +70 oC Storage temperature -25 to +105 oC Maximum Case temperature 100 Temperature coefficient ±0.02 % / oC Cooling Free air convection Humidity Non condensing 95 % RH Case material Plastic (flammability to UL 94V-0) Weight 120 g Dimensions (L x W x H) 2.76 x 1.89 x 0.93 inches 70.0 x 48.0 x 23.5 mm MTBF > 300,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.A 2 of 7 North America only Series AME20-CJZ 20 Watt | AC-DC / DC-DC Converter Safety Specifications Parameters Agency approvals cULus, CE (single output models only) Information technology Equipment EMI - Conducted and radiated emission Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Electrical Fast Transient/Burst Immunity Surge Immunity RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Voltage dips, Short Interruptions Immunity Standards IEC/EN/UL 60950-1 EN55022, class B IEC 61000-4-2 Level 3 IEC 61000-4-3 Level 3 IEC 61000-4-4 Level 3 IEC 61000-4-5 Level 3 IEC 61000-4-6 Level 3 IEC 61000-4-8 Level 3 IEC 61000-4-11 Class 2 Dimensions 3 2 Bottom View 9 8 7 6 5 1 4.00 (0.16) 1 2 4 5 6 7 8 9 3 4 62.00 (2.44) Top View 5.75 (0.23) 20.00 (0.79) 48.00 (1.89) 12.50 (0.49) 4.00 (0.16) 70.00 (2.76) 4.00 (0.16) DIV: 10.00 (0.40) Ø 1.50 (Ø 0.06) 23.50 (0.93) Dimensions mm (inch) Case Tolerance ±0.50 (±0.02) Pin Diameter 1.0 ± 0.10 (0.04 ± 0.004) 6.00 (0.24) 1.00 (0.04) Pin Out Specifications Pin Single Dual Triple Asymmetric Dual 1 2 3 4 5 6 7 8 9 Ground AC Input (N) AC Input (L) Trim -V Output No pin No pin No pin +V Output Ground AC Input (N) AC Input (L) No pin -V Output Common No pin +V Output +V Output Ground AC Input (N) AC Input (L) No pin -V Output 1 +V Output 1 -V Output 2 Common +V Output 2 Ground AC Input (N) AC Input (L) No pin -V Output 1 +V Output 1 No pin -V Output 2 +V Output 2 www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.A 3 of 7 North America only Series AME20-CJZ 20 Watt | AC-DC / DC-DC Converter Derating Free Air Convection at 25°C 100 100 80 Output Power (%) Output power (%) Free Air Convection Safe Operating Area 70 Input 100-240VAC or 120-340VDC 60 40 80 75 Safe Operating Area 60 40 20 20 0 - 25 -20 -10 0 20 40 55 70 60 80 0 85 100 (100) (120) 100 Ambient Temperature º C 240 (320) 264 (350) Input Voltage VAC (VDC) Typical application circuits FUSE 3.15A/300V Single Output NTC + Vout AC L AC L MOV S14K350 AC N AC + Vout C1 C2 1µF/50V AC N Earth/GND FUSE 3.15A/300V ‐ Vout Dual Output AC L MOV S14K350 AC + Vout DC Com C1 1µF/50V C3 1µF/50V AC N Earth/GND www.aimtec.com ‐ Vout NTC AC L AC N TVS + DC ‐ Vout C2 + Vout + TVS 1 C4 + Com TVS 2 ‐ Vout Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.A 4 of 7 North America only Series AME20-CJZ 20 Watt | AC-DC / DC-DC Converter FUSE 3.15A/300V Asymmetric Dual Output NTC + AC L AC L Vout 1 MOV S14K350 AC N C1 1µF/50V ‐ DC + AC AC N Vout 2 Earth/GND C3 1µF/50V C2 + Vout 1 + TVS 1 C4 ‐ Vout 1 + Vout 2 + TVS 2 ‐ FUSE 3.15A/300V ‐ Vout 2 Triple Output NTC + AC L AC L Vout 1 MOV S14K350 C1 1µF/50V C2 + + TVS1 ‐ ‐ AC N AC N AC Earth/GND + Vout 2 DC C5 1µF/50V Com C3 1µF/50V C6 + Vout 2 + TVS2 C4 Com + TVS3 ‐ Vout 2 ‐ Vout 2 Model Single 5 Vout Single 9 Vout Single 12 & 15 Vout Single 24 Vout Dual ±5 Vout Dual ±12 Vout Dual ±15 Vout Triple 5/±5 Vout Triple 5/±12 Vout Triple 5/±15 Vout Triple 5/±24 Vout Dual 5/12 Vout Dual 5/15 Vout Dual 5/24 Vout www.aimtec.com C2 330 µF 220 µF 220 µF 220 µF 470 µF 120 µF 68 µF 330 µF 330 µF 330 µF 330 µF 330 µF 330 µF 330 µF C4 470 µF 120 µF 68 µF 120 µF 120 µF 120 µF 47 µF 220 µF 220 µF 120 µF Vout 1 C6 120 µF 120 µF 120 µF 47 µF - TVS1 7V 12V 20V 30V 7V 20V 20V 7V 7V 7V 7V 7V 7V 7V Tel: +1 514 620 2722 TVS2 7V 20V 20V 7V 20V 20V 30V 20V 20V 30V TVS3 7V 20V 20V 30V - Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.A 5 of 7 North America only Series AME20-CJZ 20 Watt | AC-DC / DC-DC Converter Trimming Output voltage can be externally trimmed by utilizing the methods as shown below Fixed Resistor Variable Potentiometer Leave open if not used. AME20‐5SCJZ Trim down % Vout (VDC) Rt down (KΩ) Trim up % Vout (VDC) Rt up (KΩ) AME20‐9SCJZ Trim down % Vout (VDC) Rt down (KΩ) Trim up % 1 4.95 160.7 2 4.9 78.2 3 4.85 50.7 4 4.8 36.95 5 4.75 28.7 6 4.7 23.2 7 4.65 19.271 8 4.6 16.325 9 4.55 14.033 10 4.5 12.2 1 5.05 164 2 5.1 81.5 3 5.15 54 4 5.2 40.25 5 5.25 32 6 5.3 26.5 7 5.35 22.571 8 5.4 19.625 9 5.45 17.333 10 5.5 15.5 2 3 4 8.82 8.73 8.64 221.43 153.157 116.145 5 8.55 92.925 6 8.46 76.997 7 8.37 65.393 8 8.28 56.562 9 8.19 49.617 10 8.1 44.011 1 8.91 389.533 2 9.18 3 9.27 4 9.36 5 9.45 6 9.54 7 9.63 8 9.72 9 9.81 10 9.9 328.532 126.639 78.148 56.357 43.975 35.99 30.412 26.297 23.134 20.629 Vout (VDC) 1 11.88 183.233 1 12.12 2 11.76 111.59 2 12.24 3 11.64 79.474 3 12.36 4 11.52 61.246 4 12.48 5 11.4 49.499 5 12.6 6 11.28 41.299 6 12.72 7 11.16 35.249 7 12.84 8 11.04 30.602 8 12.96 9 10.92 26.921 9 13.08 10 10.8 23.933 10 13.2 Rt up (KΩ) 211.778 57.03 32.596 22.642 17.238 13.845 11.516 9.819 8.527 7.511 Vout (VDC) Rt up (KΩ) AME20‐12SCJZ Trim down % Vout (VDC) Rt down (KΩ) Trim up % www.aimtec.com 1 9.09 Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.A 6 of 7 North America only Series AME20-CJZ 20 Watt | AC-DC / DC-DC Converter AME20‐15SCJZ Trim down % 4 14.4 147.75 4 15.6 5 14.25 116.5 5 15.75 6 14.1 95.667 6 15.9 7 13.95 80.786 7 16.05 8 13.8 69.625 8 16.2 9 13.65 60.944 9 16.35 10 13.5 54 10 16.5 30.25 24 19.833 16.857 14.625 12.889 11.5 Vout (VDC) 1 2 3 4 5 6 23.76 23.52 23.28 23.04 22.8 22.56 471.081 287.942 205.845 159.249 129.221 108.258 1 2 3 4 5 6 24.24 24.48 24.72 24.96 25.2 25.44 7 22.32 92.793 7 25.68 8 22.08 80.914 8 25.92 9 21.84 71.504 9 26.16 10 21.6 63.865 10 26.4 Rt up (KΩ) 239.556 13.15 11.232 9.771 8.622 Vout (VDC) Rt down (KΩ) Trim up % Vout (VDC) Rt up (KΩ) AME20‐24SCJZ Trim down % Vout (VDC) Rt down (KΩ) Trim up % 1 14.85 616.5 1 15.15 124 2 3 14.7 14.55 304 199.833 2 3 15.3 15.45 61.5 64.606 40.667 36.982 25.728 19.619 15.783 NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.A 7 of 7 North America only