PAIRUI BCH110-150V7 Dc-dc converter Datasheet

DC-DC Converter
Bricks, Open/Enclosed
BCH SERIES, 1/2 BRICK, UP TO 350W
FEATURES:
5 years warranty
1500Vdc isolation voltage
Wide(2:1) input voltage range
Efficiency up to 90%
Operating temperature range -40°C to +100°C
Under voltage, over current, short circuit,
overvoltage protection
Remote on/off
Adjustable output voltage
Model
BCH12-120V8
Input voltage
(Vdc)
Output voltage
(Vdc)
Output current
(A)
Efficiency
Typ.
12(9.5~18)
12.0
8.33
84%
BCH24-120V6
BCH24-120V13
12.0
6.25
86%
12.0
12.50
86%
BCH24-150V7
15.0
6.67
87%
BCH24-150V10
15.0
10.00
87%
BCH24-150V13
15.0
13.40
89%
24.0
3.10
87%
BCH24-240V6
24.0
6.25
86%
BCH24-280V13
28.0
12.5
91%
BCH24-480V1
48.0
1.50
89%
BCH24-480V2
48.0
2.08
86%
BCH24-480V4
48.0
4.17
86%
BCH48-120V4
BCH48-120V6
12.0
4.20
89%
12.0
6.25
86%
BCH48-120V8
12.0
8.33
86%
BCH48-120V13
12.0
12.50
87%
BCH48-150V3
15.0
3.30
90%
BCH48-150V5
15.0
5.00
87%
15.0
6.67
87%
BCH48-240V2
24.0
2.08
87%
BCH48-240V3
24.0
3.10
87%
BCH48-240V4
24.0
4.16
88%
BCH48-240V6
BCH48-240V13
BCH48-280V4
24.0
6.25
87%
24.0
12.5
87%
28.0
3.57
86%
BCH24-240V3
BCH48-150V7
www.pairuigroup.com
24(18~36)
48(36~72)
Page:
1/4
Date: 01/23/2014
DC-DC Converter
Bricks, Open/Enclosed
BCH SERIES, 1/2 BRICK, UP TO 350W
Model
BCH48-280V13
BCH48-480V1
BCH48-480V4
BCH48-33V6-120V2
BCH48-240V8
BCH110-120V6
BCH110-120V13
BCH110-150V7
BCH110-150V10
BCH110-240V3
BCH110-240V6
Input voltage
(Vdc)
Output voltage
(Vdc)
Output current
(A)
Efficiency
Typ.
28.0
12.5
93%
48.0
1.10
88%
48.0
4.00
87%
3.3, 12.0
6.0, 2.0
84%
24.0
8.33
89%
12.0
6.25
87%
12.0
12.5
86%
15.0
6.7
87%
15.0
10.0
87%
24.0
3.0
87%
24.0
6.25
86%
28.0
5.4
87%
48(36~72)
48(31~60)
110(66~154)
BCH110-280V5
Notes: other input and output models may available on request.
ELECTRICAL
Input voltage range
24Vdc
18-36Vdc
48Vdc
31-72Vdc
110Vdc
66-154Vdc
OFF: High level or left close
Negative logic
ON: Low level or ground
Remote control
ON: High level or left open
Positive logic
OFF: Low level or ground
Output power
Input voltage range
Output voltage
Single output
Output voltage accuracy
Input voltage range, full load range
Output voltage regulation
Negative logic
±10%
Line regulation
Full load
±0.2%
Load regulation
10%-100% full load
±0.5%
Dynamic response
(transient/recovery time)
45-350W
12/15/24/28/48Vdc
25%-50%-75% load capability
Ripple and noise
Parallel test, 20MHz wide range
Operating frequency
Typical value
Isolation voltage
www.pairuigroup.com
∆Vo/∆t: ±4.0%/500μs
48V, 480mVp-p max.
Other, 240mVp-p max.
300KHz typ.
Input to output
1500Vdc
Input to case
1050Vdc
Output to case
Isolation resistance
±1%
500Vdc
---
30MΩ
Page:
2/4
Date: 01/23/2014
DC-DC Converter
Bricks, Open/Enclosed
BCH SERIES, 1/2 BRICK, UP TO 350W
ELECTRICAL
IEC-60950-1, UL-60950-1
Safety
---
Temperature coefficient
---
200ppm
PCB operating temperature
---
-40°C to +100°C
Storage temperature range
---
-40°C to +105°C
Over temperature protection
Typical
Under voltage protection
---
Yes
Over current protection
---
Yes
Short circuit protection
---
Yes
Over voltage protection
---
Yes
Relative humidity
---
95% max.
Packing
---
Hole package
MTBF
Bellcore TR-332, 25°C
EN-60950-1, GB4943
110°C typ.
2x106Hrs
Notes: Unless otherwise specified, all the parameters of the test conditions are as follows: ambient temperature
25 , the nominal input voltage, pure resistive nominal load.
℃
MECHANICAL
CONNECTION
PCB LAYOUT
www.pairuigroup.com
Page:
3/4
PIN #
SINGLE
1
-Vin
2
FG
3
REM
4
+Vin
5
GND
6
-S
7
TRIM
8
+S
9
+Vo
Date: 01/23/2014
DC-DC Converter
Bricks, Open/Enclosed
BCH SERIES, 1/2 BRICK, UP TO 350W
Note:
* Unit is mm(inch).
DERATING CURVE
EFFICIENCY CURVE
NOTES
RECOMMENDED TEST AND APPLICATION CIRCUIT
1. TVS&FUSE be helpful with over voltage protection and inrush limiting. Recommended FUSE better be 1.5~2times of the
rated current .
2. The input filter capacitor C6 could select the aluminum electrolytic capacitors or tantalum capacitors, and the withstand
voltage should be greater than the highest input voltage. Recommended capacitor should be between 22μF~100μF.
3. C1,C2 for the input filter capacitor,0.1~1μF high-frequency ceramics capacitor or chip capacitor are recommended. The
withstand voltage of output filter C5, C7 should be greater than the highest output voltage. Recommended capacitor of C7
better within 100μF and C5 connected with the chip to reduce the input voltage peak, recommended 0.1~1μF
high-frequency ceramics capacitor or chip capacitor.
www.pairuigroup.com