VER : A_2 update : 2015.11.17 AC-DC Din Rail Power Supply ADF120 SERIES 120 Watts KEY FEATURES Din Rail Switching Power Supply Universal Input: 90-264 VAC With P.F.C. Function Free Air Convection Ultra Compact Size: 1.66 x 5.16 x 3.94 Inches 3-Year Product Warranty ELECTRICAL SPECIFICATIONS All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated. Model No. ADF120-12S Max Output Wattage (W) Voltage 120W Input Output Isolation Environment Physical Safety EMC ADF120-48S 90-264 VAC or 120-370 VDC Frequency (Hz) 47-63 Hz Current (Full load) <2.0 A max. (115 VAC) / <1.0 A max. (230 VAC) Inrush Current (<2ms) < 30 A max. (115 VAC) / < 60 A max. (230 VAC) Leakage Current < 0.5 mA max. Power Factor PF>0.98 (115 VAC) / PF>0.94 (230 VAC) at Full Load Voltage (V.DC.) 12V Voltage Accuracy ±2% Current (Convection) (A) max 10 Line Regulation ±1% Load Regulation ±1% 24V 48V 5 2.5 Minimum Load 2% Maximum Capacitive Load 470-23,000µF depending on model Ripple & Noise (Note 1) 1% max. Efficiency (at 230VAC) (Note 3) Hold-up Time (typ.) Protection ADF120-24S 90% 91% 92% 15 ms (at 115VAC) / 15 ms (at 230VAC) Over Power Protection Auto recovery Over Voltage Protection Latch Off Short Circuit Protection Latch Off Input-Output (V.AC) 3000VAC or 4242VDC Input-FG (V.AC) 1500V Output-FG .(V.AC) 500V Operating Temperature -25°C…+70°C (with derating) Storage Temperature -40°C…+85°C Temperature Coefficient ±0.03%/°C Humidity 95% RH MTBF >50,000 h @ 25°C (MIL-HDBK-217F) Vibration 10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes. Dimension (L x W x H) 1.66 x 5.16 x 3.94 Inches Weight Pending Cooling Method Free convection ( 42.4 x 131.1 x 100.0 mm ) Tolerance 0.5 mm Agency Approvals CE(EN 60950-1) (Pending) EMI EN 55022 class B (Pending) (Conducted & Radiated Emission) EMS (Noise Immunity) EN 55024 (Pending) http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -1- VER : A_2 update : 2015.11.17 AC-DC Din Rail Power Supply ADF120 SERIES 120 Watts NOTE 1. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor. 2. That “natural convection” is about 20LFM but is not equal to still air (0 LFM). 3. After 30 minutes of burn-in 4. Please refer to our PDF file "AC-DC Application" on our website: www.archcorp.com.tw 5. Strongly recommend to conduct this test with DC Voltage. If customer wishes to test with AC Voltage, please disconnect all Y-Capacitors within Arch power supply. MECHANICAL DIMENSION ( Top View ) PIN# Single 1 AC IN (L) 2 AC IN (N) 3 FG 4 +DC OUT 5 +DC OUT 6 -DC OUT 7 -DC OUT BLOCK DIAGRAM DERATING http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -2-