Models Available
Specifications
Materials
CONTACT RATING: Q contact material: Switch - 2.5 AMPS @
125 V AC; 350 mA @ 125 V DC (UL/CSA). Carry - 5 AMPS
continuous. See page K-6 for additional ratings.
ELECTRICAL LIFE: 15,000 make-and-break cycles at full load up
to 300,000 detent operations.
CONTACT RESISTANCE: Below 20 m Ω typ. initial @
2-4 V DC, 100 mA, for both silver and gold plated contacts.
INSULATION RESISTANCE: 10 9 Ω min.
DIELECTRIC STRENGTH: 1,000 Vrms min. @ sea level.
Operating and storage temp: -30º to 85ºC
OPERATING & STORAGE TEMPERATURE: -30ºC to 85ºC
HOUSING & BUSHING: Glass filled 6/6 nylon (UL 94V-0).
ACTUATOR: Glass filled 6/6 nylon (UL 94V-0).
MOVABLE CONTACTS: Q contact material: Coin silver, silver plated.
See page K-6 for additional contact materials.
STATIONARY CONTACTS & TERMINALS: Q contact material: Brass,
silver plated. See page K-6 for additional contact materials.
HARDWARE: Nut - zinc, nickel plated. Lockwasher — steel, bright
zinc plated. Stop Ring - brass, nickel plated.
TERMINAL SEAL: Epoxy.
NOTE: Any models supplied with Q, B or G contact material are RoHS compliant.
NOTE: Specifications and materials listed above are for switches with standard options.
For information on specific and custom switches, consult Customer Service Center.
Build-A-Switch
To order, simply select desired option from each category and place in the appropriate box. Available options are shown and
described on pages K–4 through K–7. For additional options not shown in catalog, consult Customer Service Center.
K
Dimensions are shown: Inch (mm)
Specifications and dimensions subject to change
K–3
www.ck-components.com
Rotary
Switch Function
A100 SP, 30° Index, 12 pos. no stops
A102 SPDT, 30° Index
A103 SP, 30° Index, 3 pos.
Actuator
A104 SP, 30° Index, 4 pos.
15 1.500" high, flatted
A105 SP, 30° Index, 5 pos.
03 .375" high, flatted
A106 SP, 30° Index, 6 pos.
05 .500" high, flatted
A107 SP, 30° Index, 7 pos.
14 1.500" high, flatted
A108 SP, 30° Index, 8 pos.
42 1.654" high, metric
A109 SP, 30° Index, 9 pos.
S1 Screwdriver Slot
A110 SP, 30° Index, 10 pos.
A112 SP, 30° Index, 12 pos.
Mounting Style
A114 SP, 90° Index, 2 pos.
R 3/8-32 threaded
A115 SP, 45° Index, 3 pos.
M M10 x .75 metric
A124 SP, 90° Index, 4 pos.
Shorting/
A125 SP, 45° Index, 8 pos.
Non-shorting Contacts
A203 DP, 30° Index, 3 pos.
N Non-shorting contacts
A204 DP, 30° Index, 4 pos.
S Shorting contacts
A205 DP, 30° Index, 5 pos.
(Not available with models A114, A124 & A214)
A206 DP, 30° Index, 6 pos.
A214 DP, 90° Index, 2 pos.
Terminations
A303 3P, 30° Index, 3 pos.
Z Solder lug
A304 3P, 30° Index, 4 pos.
C PC Thru-hole
Contact Material
A402 4PDT, 30° Index
MC Modular base
Q Silver
A403 4P, 30° Index, 3 pos
B Gold
Seal
G Gold over silver
NONE No seal
E Epoxy seal
F Splashproof bushing seal
K Epoxy & splashproof bushing seal
A Series
1-4 Pole Rotary Switches
SWITCH FUNCTION
SP MODELS SCHEMATIC
30º INDEXING
NO.
POLES
SP
MODEL
NO.
SWITCH
FUNCTION
TERMINALS
A100
12 Position
No Stops
A,1-12
A102
SPDT
A,1,2*
A103
3 Position
A,1-3*
A104
4 Position
A,1-4*
A105
5 Position
A,1-5*
A106
6 Position
A,1-6*
A107
7 Position
A,1-7
A108
8 Position
A,1-8
A109
9 Position
A,1-9
A110
10 Position
A,1-10
A112
12 Position
A,1-12
A203
3 Position
A,C,1-3,7-9
A204
4 Position
A,C,1-4,7-10
A205
5 Position
A,C,1-5,7-11
A206
6 Position
A,C,1-12
A303
3 Position
A,B,C,1-3,5-7
9-11
A304
4 Position
A,B,C,1-12
30º INDEXING
NO.
POLES
MODEL
NO.
SWITCH
FUNCTION
A402
4PDT
A,B,C,D,1,2,4,5,7,
8,10,11
A403
3 Position
All Terminals
TERMINALS
4P
DP MODELS SCHEMATIC
45º INDEXING
NO.
POLES
MODEL
NO.
SWITCH
FUNCTION
A115
3 Position
A,1,2,4*
A125
8 Position
A,1,2,4,5,7,8,10,11
TERMINALS
SP
3P MODELS SCHEMATIC
90º INDEXING
DP
K
MODEL
NO.
SWITCH
FUNCTION
A114
2 Position
A,1,4*
A124
4 Position
A,1,4,7,10
A214
2 Position
A,C,1,4,7,10
TERMINALS
SP
3P
Rotary
NO.
POLES
4P MODELS SCHEMATIC
DP
TERMINAL NUMBERS
Terminal numbers
molded on bottom
of housing.
NOTE: * These models with ‘C’ or ‘MC’ terminations have additional terminal no. 9
as switch support only. This terminal is not connected electrically inside switch.
All models
with all options when ordered with ‘G’ or ‘Q’ contact
material, see page K-6.
4P MODELS
SP MODELS (omit terminals B, C & D)
DP MODELS (omit terminals B & D)
3P MODELS
Dimensions are shown: Inch (mm)
Specifications and dimensions subject to change
K–4
www.ck-components.com
A Series
1-4 Pole Rotary Switches
ACTUATOR
15
03
1.500" HIGH
.375" HIGH
05
14
.500" HIGH
1.500" HIGH
42
1.654" METRIC
S1
SCREWDRIVER SLOT
NOTE: Actuators shown in position 1, fully CCW.
MOUNTING STYLE
R
M
3/8-32 THREAD
M10 x .75 METRIC
TYPICAL INSTALLATION
Maximum force to
push on knob should
not exceed 10 in./lbs.
NUT
PANEL MOUNTING
PANEL MOUNTING
Install switch with stop ring (if used) and
lockwasher in back of panel. Tighten hex nut
from front of panel.
On PC mounted switches, use hex nut and
lockwasher to hold stop ring in place.
Actuation torque: 8–16 oz./in.
Maximum torque: 30 oz./in.
3/
8
METRIC BUSHING
IN. BUSHING
SHORTING/NON-SHORTING CONTACTS
N
NON-SHORTING CONTACTS (break-before-make)
S
SHORTING CONTACTS (make-before-break)
NOTE: ‘S’ shorting contacts are not available with A114, A124 and A214 models.
Dimensions are shown: Inch (mm)
Specifications and dimensions subject to change
K–5
www.ck-components.com
Rotary
LOCKWASHER
K
A Series
1-4 Pole Rotary Switches
TERMINATIONS
Z
C
SOLDER LUG
MC
PC THRU-HOLE
MODULAR BASE (for wave soldering)
NOTE: Switches with ‘C’ or ‘MC’ terminations have additional terminal no. 9 as switch support only. This terminal
is not connected electrically inside switch. Solder and clean switch base on PC board with other components, then
snap on housing/actuator assembly. See page K-7 for installation instructions.
PC MOUNTING
4P MODEL
SP MODEL (omit terminals B, C & D)
DP MODEL (omit terminals B & D)
Rotary
K
3P MODEL
CONTACT MATERIAL
OPTION
CODE
CONTACT AND
TERMINAL MATERIAL
RATING
SWITCH-2.5 AMPS @ 125 V AC; 350 mA @ 125V DC (UL/CSA).
CARRY-5 AMPS CONTINUOUS.
Q
SILVER 2
POWER
B
GOLD 1
LOW LEVEL/DRY CIRCUIT
0.4 VA MAX. @ 20 V AC or DC MAX
LOW LEVEL/DRY CIRCUIT
OR POWER
0.4 VA MAX. @ 20 V AC or DC MAX. or SWITCH-2.5 AMPS @ 125 V AC;
350 mA @ 125 V DC (UL/CSA). CARRY-5 AMPS CONTINUOUS.
G
GOLD OVER SILVER 3
* Note: See Technical Data section of this catalog for RoHS compliant and compatible definition and specifications.
1
MOVABLE CONTACTS: Copper alloy, with gold plate over nickel plate.
STATIONARY CONTACTS & TERMINALS: Brass, with gold plate over nickel plate.
MOVABLE CONTACTS: Coin silver, silver plated.
STATIONARY CONTACTS & TERMINALS: Brass, silver plated (standard with all
termination options).
3 MOVABLE CONTACTS: Coin silver, with gold plate over nickel plate over silver plate.
STATIONARY CONTACTS & TERMINALS: Brass, with gold plate over nickel plate
over silver plate.
NOTE: Any models supplied with Q, B or G contact material are RoHS compliant.
2
All models
with all options when ordered with ‘G’ or ‘Q’ contact material.
NOTE: ‘G’ contact material is equivalent to both ‘B’ and ‘Q” contact materials.
Dimensions are shown: Inch (mm)
Specifications and dimensions subject to change
K–6
www.ck-components.com
A Series
1-4 Pole Rotary Switches
FUNCTION
NONE
NO SEAL
E
EPOXY SEAL
F
SPLASHPROOF BUSHING SEAL
K
EPOXY & SPLASHPROOF BUSHING SEAL
SPLASHPROOF
BUSHING SEAL
Setting Stops on A112 and A125 Models
To set stops: Turn shaft fully counter-clockwise and
insert stop ring tab in desired hole. Install lockwasher
and nut to retain stop ring for both PC and panel
mounting. Switch without stop ring has 12 positions.
The number of switch positions is adjustable on A112
and A125 models only by means of a stop ring provided
with each switch. The number of positions is pre-set on
all other models and the stop ring is factory installed.
Soldering, Cleaning and Assembly Instructions for ‘MC’ Termination Option
Soldering
1. Insert switch base only into PC board.
2. Do not bend terminals.
3. Wave soldering recommended at
500F solder temperature.
4. Hand solder at 500F, 10 sec.
max./terminal.
Cleaning
1. Flux clean using vapor degreaser and forced
rinse or triple bath method.
2. Do not allow switch base to ‘trap’ fluids.
3. Freon TMC, TF or Methylene Chloride give
excellent results.
REMOVABLE CLIP
K
Rotary
Switch Assembly
1. Hold housing/shaft assembly by housing. Remove
protective cap by squeezing tabs and discard. (FIG. 1)
2. Do not push on switch shaft. Detent mechanism will
come apart.
3. While holding switch housing, align locating tab on
base with notch on housing and engage 4 housing
latches in slots on base. (FIG. 2)
4. Push firmly on housing until latches snap in place.
5. Remove clip from shaft and discard. Assembly is
complete. (FIG. 3)
(FIG. 1)
LOCATING
TAB
STANDOFF
(FIG. 2)
(FIG. 3)
AVAILABLE HARDWARE
Stop ring
PART NO.
767B00201
Material: Brass
Finish: Nickel plated
Dimensions are shown: Inch (mm)
Specifications and dimensions subject to change
K–7
www.ck-components.com
Similar pages