XP Power DDC3024S12 Dc-dc power supply Datasheet

DDC30 Series
DC-DC Power Supplies
30 Watts
xxx Series
• 4:1 DC Input Range
• 5 V to 24 V DC Output
• Low Profile Design
• Ambient Operation from -40 °C to +70 °C
• Remote On/Off
• 1500 VDC Isolation
• Class B Conducted and Radiated Emissions
• High Efficiency – Up to 85%
• 3 Year Warranty
The DDC series is a range of DIN Rail mounting DC/DC converters designed to offer
additional voltages in AC input DIN Rail power systems, provide isolated outputs & noise
immunity or support battery powered or battery backed applications. With a 4:1 wide
input range the DDC series converters can be supplied by both a 12V or 24V nominal
input and offer output voltages between 5VDC and 24VDC
Dimensions:
DDC30:
1.38 x 3.58 x 2.22” (35.0 x 91.0 x 56.5 mm)
Models & Ratings
Output Voltage
5
9
12
15
24
Output Power
V
V
V
V
V
22.5
25.0
30.0
30.0
30.0
W
W
W
W
W
Output
Voltage Trim
4.75-5.5
8.55-9.9
11.4-13.8
14.25-16.5
22.8-27.6
V
V
V
V
V
Output Current(1)
4.5
2.8
2.5
2.0
1.25
A
A
A
A
A
Input Current
Typical, Max
Maximum
Capacitive Load
Efficiency(2)
Model Number
1.13 A, 3.1 A
1.25 A, 3.4 A
1.48 A, 4 A
1.48 A, 4 A
1.48 A, 4 A
3500 µF
2200 µF
1000 µF
1000 µF
470 µF
81%
82%
83%
84%
85%
DDC3024S05
DDC3024S09
DDC3024S12
DDC3024S15
DDC3024S24
Notes
1. Ouput current should be limited so that nominal output power is not exceeded
2. Typical efficiency at nominal input and full load.
Mechanical Details
2.22 (56.0)
1.96 (49.8)
1.38 (35.0)
1.28 (32.5)
1 2 3 4
Pin Connector
3.58
(91.0)
1.77
(45.0)
3.58
(91.0)
0.43
(11.0)
1 2 3
1
0.47
(12.0)
2.05 (52.0)
www.xppower.com
Conn Pin
1
DC
2
I/P
3
1
2
DC
O/P
3
4
Designation
Remote On/Off
+Vin
-Vin
+Vout
+Vout
-Vout
-Vout
DDC30 Series
DC-DC Power Supplies
Input
Characteristic
Input Voltage Range
Minimum
Typical
9
Maximum
Units
36
VDC
20
A
40
VDC
Input Current
See Models and Ratings table
Inrush Current
Input Filter
Pi type
Undervoltage Lockout
On at >8.5 V
Input Surge
Input Protection
Notes & Conditions
at 36 V
No Damage
T7.0A/63 VDC Internal Fuse
Output
Typical
Notes & Conditions
Characteristic
Minimum
Maximum
Units
Output Voltage
5
24
V
See Models and Ratings table
%
See Models and Ratings table
Initial Set Accuracy
0
+1
Minimum Load
0
Output Voltage Trim
%
A
Start Up Delay
50
Start Up Rise Time
2
No minimum load required
ms
ms
Line Regulation
±1.0
%
Load Regulation
±1.0
%
Transient Response
Ripple & Noise
0 - 10% load
4
% deviation
100
mV pk-pk
165
%
Trip & Restart (hiccup mode)
135
%
Of nominal output voltage
0.03
%/ ˚C
Short Circuit Protection
20 MHz bandwidth
Trip & Restart (hiccup mode), auto recovery
Overload Protection
110
Overvoltage Protection
115
Temperature Coefficient
Remote On/Off
Recovery to within 1% in <1 ms for a 50% load change
at 0.25 A/µs rate
Output On: Open circuit or 8-10 VDC WRT -Vin
Output Off: -0.3 - 2 VDC WRT -Vin
General
Characteristic
Minimum
Efficiency
Typical
Maximum
83
Isolation
1500
Switching Frequency
100
%
kHz
2.7
W/in3
kHrs
0.265 (120)
DC ON Indicator
90
DC Low Indicator
70
See Models and Ratings table
200
680
Weight
Notes & Conditions
VDC
Power Density
Mean Time Between Failure
Units
MIL-HDBK-217F, +25 °C GB
lb (g)
90
%
Of nominal voltage. Green LED
%
Of nominal voltage. Red LED
Environmental
Characteristic
Maximum
Units
Notes & Conditions
Operating Temperature
-40
+70
°C
See derating curve
Storage Temperature
-55
+100
°C
5
90
%RH
4850
m
Humidity
Operating Altitude
Minimum
Typical
Cooling
Non-condensing
Natural convection
Shock
±3 shocks in each plane, total 36 shocks of 15 g : 11 ms halfsine. Conforms to EN60068-2-27
Vibration
10-500 Hz at 2 g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6
www.xppower.com
2
DDC30 Series
DC-DC Power Supplies
EMC: Emissions
Phenomenon
Standard
Test Level
Conducted
EN55022
Class B
Radiated
EN55022
Class B
Standard
Test Level
Criteria
Notes & Conditions
Criteria
Contact
EMC: Immunity
Phenomenon
ESD Immunity
EN61000-4-2
Radiated Immunity
EN61000-4-3
6 kV
10 V/m
A
EFT/Burst
EN61000-4-4
2
A
Surges
EN61000-4-5
Installation class 3
A
Conducted
EN61000-4-6
10 V
A
Magnetic Fields
EN61000-4-8
4
Dips and Interruptions
EN55024
Air Discharge
A
8 kV
Notes & Conditions
A
Dip: 30%, 10 ms
A
Dip: 60%, 100 ms
B
Dip: 100%, 5000 ms
B
Safety Approvals
Safety Agency
Safety Standard
Notes & Conditions
UL
UL508
Industrial Control Equipment
TUV
EN60950-1 A12:2011
Information Technology
CB
IEC60950-1 +A1:2009
Information Technology
Application Notes
Derating Curves
120
100
100
80
<9.5 V input
>28.0 V input
Load (%)
Load (%)
80
60
40
Safe Operating Area
20
-40
-20
0
20
40
60
80
9
28
Input Voltage (V)
Ambient Temperature (°C)
3
0
www.xppower.com
36
DDC30 Series
DC-DC Power Supplies
Mechanical Details
2.22 (56.0)
1.96 (49.8)
1.38 (35.0)
1.28 (32.5)
1 2 3 4
Pin Connector
3.58
(91.0)
1.77
(45.0)
3.58
(91.0)
0.43
(11.0)
1 2 3
0.47
(12.0)
Conn Pin
1
DC
2
I/P
3
1
2
DC
O/P
3
4
Designation
Remote On/Off
+Vin
-Vin
+Vout
+Vout
-Vout
-Vout
2.05 (52.0)
Notes
1. All dimensions in inches (mm)
2. Weight: 0.265 lbs (120 g)
3. Tolerance: ±0.02 in (±0.5 mm)
4. Screw terminal: 12-24 AWG cables size.
5. Connection screw maximum torque: Input: 6 lbs-in (0.68 Nm)
www.xppower.com
12-Feb-15
Similar pages