Teledyne CR-33SXC-TMS Failsafe spdt coaxial switch Datasheet

Series CCR-33S/CR-33S
COAX SWITCHES
Miniature DC–18 GHz/DC-22 GHz
Failsafe SPDT Coaxial Switch
PART NUMBER
DESCRIPTION
CCR-33S
Commercial Failsafe SPDT, DC-18GHz
CR-33S
Elite Failsafe SPDT, DC-22GHz
Available with
USB & Ethernet
Control!
The CCR-33S/CR-33S is a broadband, SPDT, electromechanical, coaxial switch designed to switch
a microwave signal from a common input to either of two outputs. The characteristic impedance is 50
Ohms. The small switches incorporate SMA connectors.
The CCR-33S/CR-33S series switch is offered with a failsafe actuator. This design is compatible with the
two most common mounting hole patterns. The CCR-33S/CR-33S series switch is interchangeable with
a variety of switches.
Click here
MMA SERIES
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS
ELECTRICAL CHARACTERISTICS
Operating Temperature
Commercial Model, CCR-33S
Elite Model, CR-33S
Form Factor
–40°C to 65°C
–55°C to 85°C
SPDT,
break before make
Vibration (MIL-STD-202 Method 214,
Condition D, non-operating)
10 g’s RMS
Frequency Range
CCR-33S
CR-33S
DC–18 GHz
DC–22 GHz
Shock (MIL-STD-202 Method 213,
Condition D, non-operating)
500 g’s
Characteristic Impedance
50 Ohms
Standard Actuator Life
Actuator Life w/ Additional Features
5,000,000 cycles
1,000,000 cycles
Operate Time
10 ms (max.)
Release Time
10 ms (max.)
Connector Type
SMA
Humidity (Moisture Seal)
Available
Weight
1.65 oz. (46.78g) (max.)
Actuation Voltage Available
12
Actuation Current, max. @ ambient
200 250 120
15
24
28 V
90 mA
TYPICAL PERFORMANCE CHARACTERISTICS
Frequency
DC–4 GHz
4–8 GHz
8–12 GHz
12–16 GHz
16-20 GHz
20-22 GHz
0.1
0.2
0.2
0.3
0.4
0.4
Insertion Loss, dB,
typcial.
Isolation, dB, typical.
VSWR , typical.
90
90
80
70
65
65
1.1:1
1.1:1
1.1:1
1.2:1
1.2:1
1.2:1
For maximum limits, please see charts on page 3-5
PART NUMBERING SYSTEM
CCR-33
S
1
C
-
T **
Series
Options
Connectors
Actuator Type
Actuator Voltage
Connector
S: SMA Female
Actuator Voltage
1: 28 Vdc Failsafe
2: 15 Vdc Failsafe
3: 12 Vdc Failsafe
4: 24 Vdc Failsafe
Actuator Type
0: Standard Contacts
C: Indicator Contacts
**SEE PARTS LIST ON PAGE 8
Options
T: TTL Drivers with Diodes
D: Transient Suppression
Diodes
N: Narrow Body
M: Moisture Seal
S: 9 Pin D-Sub Connector
For other options, contact factory.
© 2015 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCR-33S/CR-33S Page 1
CCR-33S\CR-33S\092015\Q3
Series CCR-33S/CR-33S
COAX SWITCHES
Miniature DC–18 GHz/DC-22 GHz
Failsafe SPDT Coaxial Switch
SCHEMATICS AND MECHANICAL OUTLINE
Analog
TTL
Indicators
2X SOLDER TERMINALS
SOLDER WIRE MAXIMUM
TEMP 250ºC FOR NO
MORE THAN 5 SEC
2X SOLDER TERMINALS
SOLDER WIRE MAXIMUM
TEMP 250ºC FOR NO
MORE THAN 5 SEC
H = 1.30 MAX. STD MODEL
H = 1.80 MAX. TTL MODEL
H = 1.30 MAX. STD MODEL
H = 1.80 MAX. TTL MODEL
Optional Narrow Width Body
Standard Width Body
1
6
“-s option” 9-pin d-P/N
sub 2706650
connector (example:
9 PIN D-SUB PINOUT FOR FAILSAFE SPDT
Pin
No.
1
2
3
4
5
6
7
8
9
OPTIONS
Basic
Indicators
+
-
+
-
CCR-33S/CR-33S Page 2
A
B
C
TTL
TRUTH TABLE (with TTL option)
Logic
Input
Indicators &
TTL
1
1
Vsw
Common
P/N 2707572
1
Vsw
A
B1
C611
RF Path
Indicator
(if applicable)
IN
to 1
IN
to 2
A
0
On
Off
C
0
1
Off
On
0
C
9
Common
1
ccr-33s10-s)
B
5
10
15
SPECIFICATIONS ARE AMPHENOL
SUBJECT TO CHANGE
WITHOUT NOTICE
P/N
P-17EHD-015P
© 2015 TELEDYNE COAX SWITCHES
CCR-33S\CR-33S\092015\Q3
Series CCR-33S/CR-33S
COAX SWITCHES
Miniature DC–18 GHz/DC-22 GHz
Failsafe SPDT Coaxial Switch
TYPICAL NARROWBAND RF INSERTION LOSS PERFORMANCE CURVES
Insertion Loss ( 4-8 GHz )
0.0
-0.1
-0.1
-0.2
-0.2
Insertion Loss (dB)
Insertion Loss (dB)
Insertion Loss ( DC-4 GHz )
0.0
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-1.0
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
0
0.5
1
1.5
2
2.5
3
3.5
-1.0
4
4
4.5
5
5.5
Frequency ( GHz )
-0.1
-0.1
-0.2
-0.2
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
7.5
8
15
15.5
16
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
8
8.5
9
9.5
10
10.5
11
11.5
-1.0
12
12
12.5
13
13.5
14
14.5
Frequency ( GHz )
Insertion Loss ( 16-20 GHz )
Insertion Loss ( 20-22 GHz )
0.0
0.0
-0.1
-0.1
-0.2
-0.2
Insertion Loss (dB)
Insertion Loss (dB)
7
-0.3
Frequency ( GHz )
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-1.0
6.5
Insertion Loss ( 12-16 GHz )
0.0
Insertion Loss (dB)
Insertion Loss (dB)
Insertion Loss ( 8-12 GHz )
0.0
-1.0
6
Frequency ( GHz )
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
16
16.5
17
17.5
18
18.5
19
19.5
20
-1.0
20
Frequency ( GHz )
20.5
21
21.5
22
Frequency ( GHz )
elite model only
TYPICAL
MAXIMUM TEST LIMIT
© 2015 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCR-33S/CR-33S Page 3
CCR-33S\CR-33S\092015\Q3
Series CCR-33S/CR-33S
COAX SWITCHES
Miniature DC–18 GHz/DC-22 GHz
Failsafe SPDT Coaxial Switch
TYPICAL NARROWBAND RF ISOLATION PERFORMANCE CURVES
Isolation ( 4-8 GHz )
0.0
-20.0
-20.0
-40.0
-40.0
Isolation (dB)
Isolation (dB)
Isolation ( DC-4 GHz )
0.0
-60.0
-80.0
-100.0
-80.0
-100.0
-120.0
-140.0
-60.0
-120.0
0
0.5
1
1.5
2
2.5
3
3.5
4
-140.0
4
4.5
5
5.5
Frequency ( GHz )
-20.0
-20.0
-40.0
-40.0
-60.0
-80.0
-100.0
7.5
8
15
15.5
16
-60.0
-80.0
-120.0
8
8.5
9
9.5
10
10.5
11
11.5
12
-140.0
12
12.5
13
13.5
Frequency ( GHz )
14
14.5
Frequency ( GHz )
Isolation ( 16-20 GHz )
Isolation ( 20-22 GHz )
0.0
0.0
-20.0
-20.0
-40.0
-40.0
Isolation (dB)
Isolation (dB)
7
-100.0
-120.0
-60.0
-80.0
-100.0
-60.0
-80.0
-100.0
-120.0
-140.0
6.5
Isolation ( 12-16 GHz )
0.0
Isolation (dB)
Isolation (dB)
Isolation ( 8-12 GHz )
0.0
-140.0
6
Frequency ( GHz )
-120.0
16
16.5
17
17.5
18
18.5
19
19.5
20
-140.0
20
20.5
Frequency ( GHz )
21
21.5
22
Frequency ( GHz )
elite model only
TYPICAL
MAXIMUM TEST LIMIT
CCR-33S/CR-33S Page 4
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2015 TELEDYNE COAX SWITCHES
CCR-33S\CR-33S\092015\Q3
Series CCR-33S/CR-33S
COAX SWITCHES
Miniature DC–18 GHz/DC-22 GHz
Failsafe SPDT Coaxial Switch
TYPICAL NARROWBAND RF VSWR PERFORMANCE CURVES
VSWR ( DC-4 GHz )
VSWR ( 4-8 GHz )
2.0
2.0
1.9
1.9
1.8
1.8
1.7
1.7
1.6
1.5
VSWR
VSWR
1.6
1.4
1.3
1.4
1.3
1.2
1.2
1.1
1.0
1.5
1.1
0
0.5
1
1.5
2
2.5
3
3.5
1.0
4
Frequency ( GHz )
4
4.5
5
1.9
1.9
1.8
1.8
1.7
1.7
1.6
1.6
1.5
1.4
1.3
1.2
1.1
1.1
9
9.5
10
10.5
11
11.5
1.0
12
12
12.5
13
13.5
Frequency ( GHz )
1.9
1.9
1.8
1.8
1.7
1.7
1.6
1.6
1.5
1.4
1.3
1.2
1.1
1.1
17.5
18
14.5
15
15.5
16
1.4
1.2
17
14
1.5
1.3
16.5
8
VSWR ( 20-22 GHz )
2.0
VSWR
VSWR
VSWR ( 16-20 GHz )
16
7.5
Frequency ( GHz )
2.0
1.0
7
1.4
1.2
8.5
6.5
1.5
1.3
8
6
VSWR ( 12-16 GHz )
2.0
VSWR
VSWR
VSWR ( 8-12 GHz )
2.0
1.0
5.5
Frequency ( GHz )
18.5
19
19.5
20
1.0
20
Frequency ( GHz )
20.5
21
21.5
22
Frequency ( GHz )
elite model only
TYPICAL
MAXIMUM TEST LIMIT
© 2015 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCR-33S/CR-33S Page 5
CCR-33S\CR-33S\092015\Q3
Series CCR-33S/CR-33S
COAX SWITCHES
Miniature DC–18 GHz/DC-22 GHz
Failsafe SPDT Coaxial Switch
TYPICAL POWER PERFORMANCE CURVE
Power Handling vs. Frequency
3000
2000
Power (W)
1000
800
600
400 STAN
DAR
DS
300
MA
200
SW
ITC
HES
100
80
60
40
30
20
10
.1
.2
.3 .4 .6 .8 1
2
4
6 8 10
18
Frequency GHz
Estimates based on the following reference conditions:
• Ambient temperature of 40°C or less
• Sea level operation
• Load VSWR of 1.20:1 maximum
• No high-power (hot) switching
Please contact Teledyne Coax Switches for derating factors when applications do not meet the foregoing reference conditions.
CCR-33S/CR-33S Page 6
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2015 TELEDYNE COAX SWITCHES
CCR-33S\CR-33S\092015\Q3
Series CCR-33S/CR-33S
COAX SWITCHES
Miniature DC–18 GHz/DC-22 GHz
Failsafe SPDT Coaxial Switch
GLOSSARY
Actuator
An actuator is the electromechanical mechanism that
transfers the RF contacts from one position to another upon
DC command.
TTL Switch Driver Option
As a special option, switch drivers can be provided for both
failsafe and latching switches, which are compatible with
industry-standard low-power Schottky TTL circuits.
Arc Suppression Diode
A diode is connected in parallel with the coil. This diode
limits the “reverse EMF spike” generated when the coil deenergizes to 0.7 volts. The diode cathode is connected to
the positive side of the coil and the anode is connected to
the negative side.
Performance Parameters vs Frequency
Generally speaking, the RF performance of coaxial switches
is frequency dependent. With increasing frequency, VSWR
and insertion loss increase while isolation decreases. All
data sheets specify these three parameters as “worst case”
at the highest operating frequency. If the switch is to be
used over a narrow frequency band, better performance
can be achieved.
Date Code
All switches are marked with either a unique serial number
or a date code. Date codes are in accordance with MILSTD-1285 Paragraph 5.2.5 and consist of four digits.
The first two digits define the year and the last two digits
define the week of the year (YYWW). Thus, 1032 identifies
switches that passed through final inspection during the
32nd week of 2010.
Failsafe
A failsafe switch reverts to the default or failsafe position
when actuating voltage is removed. This is realized by a
return spring within the drive mechanism. This type of switch
requires the continuous application of operating voltage to
select and hold any position. (Multi-position switches are
normally open with no voltage applied).
Indicator
Indicators tell the system which position the switch is in.
Other names for indicators are telemetry contacts or tellback
circuit. Indicators are usually a set of internally mounted DC
contacts linked to the actuator. They can be wired to digital
input lines, status lights, or interlocks. Unless otherwise
specified, the maximum indicator contact rating is 30 Vdc,
50 mA, or 1.5 Watts into a resistive load.
Isolation
Isolation is the measure of the power level at the output
connector of an unconnected RF channel as referenced to
the power at the input connector. It is specified in dB below
the input power level.
SPDT Switch
A single-pole double-throw, bi-directional switch that can
be used as having one input and two outputs or two inputs
and one output.
Switching Time
Switching time is the total interval beginning with the arrival
of the leading edge of the command pulse at the switch DC
input and ending with the completion of the switch transfer,
including contact bounce. It consists of three parts: (1)
inductive delay in the coil, (2) transfer time of the physical
movement of the contacts, and (3) the bounce time of the
RF contacts.
© 2015 TELEDYNE RELAYS
Actuator Current vs Temperature
The resistance of the actuator coil varies as a function of
temperature. There is an inverse relationship between the
operating temperature of the switch and the actuator drive
current. For switches operating at 28 VDC, the approximate
actuator drive current at temperature, T, can be calculated
using the equation:
IT =
IA
[1 + .00385 (T-20)]
Where:
IT = Actuator current at temperature, T
IA = Room temperature actuator current –
see data sheet
T = Temperature of interest in °C
Magnetic Sensitivity
An electro-mechanical switch can be sensitive to ferrous
materials and external magnetic fields. Neighboring ferrous
materials should be permitted no closer than 0.5 inches and
adjacent external magnetic fields should be limited to a flux
density of less than 5 Gauss.
SPECIAL FEATURE
Switching High-Power or Highly Sensitive Signals
Ensure the most linear response with the best galvanically
matched contact system in the industry. Extremely low
passive intermodulation is standard on all of our switches.
Carrier
Frequency 1
Carrier
Frequency 2
PIM 3rd Order
Frequency
PIM 5th
Order Frequency
870 MHz
893 MHz
847 MHz
824 MHz
SPDT
(800) 284-7007 • www.teledynecoax.com
3rd Order
Intermodulation
5th Order
Intermodulation
–91 dBm
–110 dBm
–134 dBc
–153 dBc
CCR-33S/CR-33S Page 7
CCR-33S\CR-33S\092015\Q3
Series CCR-33S/CR-33S
COAX SWITCHES
Miniature DC–18 GHz/DC-22 GHz
Failsafe SPDT Coaxial Switch
FAILSAFE CCR-33S/CR-33S PART NUMBER LIST
Part No.
1
*
CCR-33SXC
Part No.
43
CCR-33SX0-TMS
Part No.
85
CR-33SX0-NM
2
CCR-33SXC-D
44
CCR-33SX0-TN
86
CR-33SX0-NMS
3
CCR-33SXC-DM
45
CCR-33SX0-TNM
87
CR-33SX0-NS
4
CCR-33SXC-DMS
46
CCR-33SX0-TNMS
88
CR-33SX0-S
5
CCR-33SXC-DN
47
CCR-33SX0-TNS
89
CR-33SX0-T
6
CCR-33SXC-DNM
48
CCR-33SX0-TS
90
CR-33SX0-TM
7
CCR-33SXC-DNMS
49
CR-33SXC
91
CR-33SX0-TMS
8
CCR-33SXC-DNS
50
CR-33SXC-D
92
CR-33SX0-TN
9
CCR-33SXC-DS
51
CR-33SXC-DM
93
CR-33SX0-TNM
10
CCR-33SXC-M
52
CR-33SXC-DMS
94
CR-33SX0-TNMS
11
CCR-33SXC-MS
53
CR-33SXC-DN
95
CR-33SX0-TNS
12
CCR-33SXC-N
54
CR-33SXC-DNM
96
CR-33SX0-TS
13
CCR-33SXC-NM
55
CR-33SXC-DNMS
14
CCR-33SXC-NMS
56
CR-33SXC-DNS
15
CCR-33SXC-NS
57
CR-33SXC-DS
16
CCR-33SXC-S
58
CR-33SXC-M
17
CCR-33SXC-T
59
CR-33SXC-MS
18
CCR-33SXC-TM
60
CR-33SXC-N
19
CCR-33SXC-TMS
61
CR-33SXC-NM
20
CCR-33SXC-TN
62
CR-33SXC-NMS
21
CCR-33SXC-TNM
63
CR-33SXC-NS
22
CCR-33SXC-TNMS
64
CR-33SXC-S
23
CCR-33SXC-TNS
65
CR-33SXC-T
24
CCR-33SXC-TS
66
CR-33SXC-TM
25
CCR-33SX0
67
CR-33SXC-TMS
26
CCR-33SX0-D
68
CR-33SXC-TN
27
CCR-33SX0-DM
69
CR-33SXC-TNM
28
CCR-33SX0-DMS
70
CR-33SXC-TNMS
29
CCR-33SX0-DN
71
CR-33SXC-TNS
30
CCR-33SX0-DNM
72
CR-33SXC-TS
31
CCR-33SX0-DNMS
73
CR-33SX0
32
CCR-33SX0-DNS
74
CR-33SX0-D
33
CCR-33SX0-DS
75
CR-33SX0-DM
34
CCR-33SX0-M
76
CR-33SX0-DMS
35
CCR-33SX0-MS
77
CR-33SX0-DN
36
CCR-33SX0-N
78
CR-33SX0-DNM
37
CCR-33SX0-NM
79
CR-33SX0-DNMS
38
CCR-33SX0-NMS
80
CR-33SX0-DNS
39
CCR-33SX0-NS
81
CR-33SX0-DS
40
CCR-33SX0-S
82
CR-33SX0-M
41
CCR-33SX0-T
83
CR-33SX0-MS
42
CCR-33SX0-TM
84
CR-33SX0-N
X = 1 (28Vdc), 2 (15Vdc), 3 (12Vdc) and 4 (24Vdc)
CCR-33S/CR-33S Page 8
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2015 TELEDYNE COAX SWITCHES
CCR-33S\CR-33S\092015\Q3
Similar pages