Mean Well DLC03C-12 3w dip package dc-dc regulated converter Datasheet

3W DIP Package DC-DC Regulated Converter
■ Features
DIP16 package with industry standard pinout
2:1 wide input range
Operating temperature range -40 ~ +85℃
No minimum load required
Comply to EN55032 radiated Class B without additional
components
High efficiency up to 82%
Protections: Short circuit (Continuous) / Overload /
SLC03 & DLC03 series
■ Applications
Telecom/ datacom system
Wireless network
Industrial control facility
Instrument
Analyzer
Detector
Data switch
Input under voltage
1.5KVDC I/O isolation
3 years warranty
■ Description
SLC03 and DLC03 series are 3W isolated and regulated module type DC-DC converter with DIP16 package.
It features international standard pins, a high efficiency up to 8 2 %, wide working temperature range
-40~+ 85℃, 1 . 5 KVDC I/P-O/P isolation voltage, the compliance to EN55032 radiated Class B without
additional components, continuous-mode short circuit protection, etc. The models account for different
input voltage , 9~18V, 18~36V and 36~75V 2:1 wide input range, and various output voltage, 5V/12V/
15V for single output and ±5V/±12V/±15V for dual outputs, which are suitable for all kinds of systems,
such as industrial control, telecommunication field, distributed power architecture, and so on.
■ Model Encoding
S LC03 A - 12
Output voltage (5/12/15Vdc, ±5/±12/±15Vdc)
Input voltage (A: 9~18Vdc,B: 18~36Vdc,C: 36~75Vdc)
Rated wattage
Series name
output
{ S:Single
D:Dual output
File Name:SLC03,DLC03-SPEC 2017-06-21
SLC03 & DLC03 series
3W DIP Package DC-DC Regulated Converter
MODEL SELECTION TABLE
INPUT
ORDER NO.
INPUT VOLTAGE
(RANGE)
OUTPUT
INPUT CURRENT
OUTPUT
VOLTAGE
OUTPUT
CURRENT
EFFICIENCY
(TYP.)
CAPACITOR LOAD
(MAX.)
NO LOAD
FULL LOAD
SLC03A-05
25mA
330mA
5V
600mA
79%
1000μF
SLC03A-12
15mA
320mA
12V
250mA
81%
470μF
15mA
309mA
15V
200mA
81%
330μF
30mA
325mA
±5V
±0 ~ 300mA
79%
* 220μF
DLC03A-12
32mA
305mA
±12V
±0 ~ 125mA
82%
*220μF
DLC03A-15
32mA
313mA
±15V
±0 ~ 100mA
81%
*220μF
SLC03B-05
10mA
154mA
5V
600mA
81%
1000μF
SLC03B-12
10mA
154mA
12V
250mA
82%
470μF
10mA
153mA
15V
200mA
82%
330μF
20mA
158mA
±5V
±0 ~ 300mA
79%
*220μF
DLC03B-12
20mA
156mA
±12V
±0 ~ 125mA
81%
*220μF
DLC03B-15
20mA
156mA
±15V
±0 ~ 100mA
80%
*220μF
SLC03C-05
7mA
77mA
5V
600mA
81%
1000μF
SLC03C-12
7mA
76mA
12V
250mA
82%
470μF
7mA
76mA
15V
200mA
82%
330μF
10mA
79mA
±5V
±0 ~ 300mA
80%
*220μF
DLC03C-12
10mA
78mA
±12V
±0 ~ 125mA
80%
*220μF
DLC03C-15
10mA
78mA
±15V
±0 ~ 100mA
80%
*220μF
SLC03A-15
DLC03A-05
12V
(9 ~ 18V)
SLC03B-15
DLC03B-05
24V
(18 ~ 36V)
SLC03C-15
DLC03C-05
48V
(36 ~ 75V)
* For each output
File Name:SLC03,DLC03-SPEC 2017-06-21
3W DIP Package DC-DC Regulated Converter
SLC03 & DLC03 series
SPECIFICATION
VOLTAGE RANGE
A: 9~18Vdc , B: 18~36Vdc , C: 18~75Vdc
SURGE VOLTAGE (100ms max.) 12Vin models : 25Vdc ; 24Vin models : 50V ; 48Vin models : 100Vdc
INPUT
FILTER
Internal capacitor
PROTECTION
Fuse recommended. 12Vin models: 1A Slow-Blow Type, 24Vin models: 0.5A Slow-Blow Type, 48Vin models: 200mA Slow-Blow Type
INTERNAL POWER DISSIPATION 1000mW
OUTPUT
VOLTAGE ACCURACY
±2%
RATED POWER
3W
RIPPLE & NOISE
Note.2 50mVp-p
LINE REGULATION Note.3 ±0.2%
LOAD REGULATION Note.4 ±0.5%
SWITCHING FREQUENCY (Typ.) 100KHz
SHORT CIRCUIT
PROTECTION
OVERLOAD
UNDER VOLTAGE LOCKOUT
ENVIRONMENT
Protection type : Continuous, automatic recovery
150 ~ 250% rated output power
Protection type : Recovers automatically after fault condition is removed
Start-up voltage
12Vin: 8.8Vdc, 24Vin: 17Vdc, 48Vin: 34Vdc
Shutdown voltage
12Vin: 7Vdc,
COOLING
Free-air convection
WORKING TEMP.
-40 ~ +85℃ (Refer to "Derating Curve")
CASE TEMPERATURE
+100℃ max.
WORKING HUMIDITY
20% ~ 90% RH non-condensing
24Vin: 14Vdc, 48Vin: 30Vdc
STORAGE TEMP., HUMIDITY -40 ~ +105℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT
0.03% / ℃ (0 ~ 80℃)
SOLDERING TEMPERATURE 1.5mm from case of 3 ~ 5sec./265℃ max.
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
WITHSTAND VOLTAGE
I/P-O/P:1.5KVDC
ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
ISOLATION CAPACITANCE (Typ.) 80pF
Parameter
Standard
Test Level / Note( Note.6)
Conducted
EN55032(CISPR32)
N/A
SAFETY &
Radiated
EN55032(CISPR32)
Class B
EMC
( Note.5)
Parameter
Standard
Test Level / Note
ESD
EN61000-4-2
Level 3, ±8KV air
Radiated Susceptibility
EN61000-4-3
Level 2, 3V/m
EFT/Burest
EN61000-4-4
Level 1, 0.5KV
Surge
EN61000-4-5
Level 2, 0.5KV Line-Line
Conducted
EN61000-4-6
Level 2, 3V
Magnetic Field
EN61000-4-8
Level 1, 1A/m
EMC EMISSION
EMC IMMUNITY
OTHERS
NOTE
MTBF
300Khrs min. MIL-HDBK-217F(25℃)
DIMENSION (L*W*H)
22.1*13.8*8.55mm (0.87*0.54*0.34 inch)
CASE MATERIAL
Non-Conductive black plastic (UL 94V-0 rated)
PACKING
4.5g
1.All parameters are specified at normal input(A:12Vdc, B:24Vdc, C:48Vdc), rated load, 25℃ 70% RH ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μf & 47μf capacitor.
3.Line regulation is measured from low line to high line at rated load.
4.Load regulation is measured from 10% to 100% rated load.
5.The final equipment must be re-confirm that it still meet EMC directives. For guidance on how to perform these EMC tests, please
refer to “EMI testing of component power supplies.”(as available on http://www.meanwell.com)
6.An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5.
The filter capacitor Power Mate suggest: 220uF/100V.
File Name:SLC03,DLC03-SPEC 2017-06-21
SLC03 & DLC03 series
3W DIP Package DC-DC Regulated Converter
Mechanical Specification
All dimensions in mm(inch)
Tolerance:x.x±0.5mm( x.xx±0.02")
x.xx±0.25mm( x.xxx±0.01")
Pin size is 0 . 50 x0 . 30 mm ( 0 . 02" x 0.01")
Pin is Tolerance:x.xx±0.07mm( x.xx x±0.03")
22.1(0.87)
1.77(0.07)
7
8
10
9
Bottom View
16
13.8(0.54)
10.16(0.4)
1
0.5(0.02)
3.81(0.15)
Side View
8.55(0.34)
0.5(0.02)
22.1(0.87)
15.24(0.6)
2.54(0.1)
2.16(0.09)
Derating Curve
Plug Assignment
Pin-Out
SLC03
(Single output)
DLC03
(Dual output)
1
-Vin
-Vin
7
N.C.
N.C.
8
N.C.
Common
9
+Vout
+Vout
10
-Vout
-Vout
16
+Vin
+Vin
100
LOAD (%)
Pin No.
80
60
50
40
Natural convection
20
-40
-20
0
20
40
60
71
85
100
Ta (℃)
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
File Name:SLC03,DLC03-SPEC 2017-06-21
Similar pages