Series AM8TW-IZ 8 Watt | DC-DC Converter FEATURES: RoHS compliant 24 Pin DIP Package Wide 4:1 input range Power modules for PCB mounting Over Voltage Protection Operating temperature -40oC to + 75oC Regulated output Low ripple and noise Input/Output Isolation voltage 1500VDC Continuos Short Circuit Protection Models Single output Model AM8TW-2403SIZ AM8TW-2405SIZ AM8TW-2412SIZ AM8TW-2415SIZ AM8TW-4803SIZ AM8TW-4805SIZ AM8TW-4812SIZ AM8TW-4815SIZ AM8TW-11005SIZ AM8TW-11012SIZ AM8TW-11015SIZ AM8TW-11024SIZ Input Voltage (V) 9-36 9-36 9-36 9-36 18-75 18-75 18-75 18-75 36-160 36-160 36-160 36-160 Output Voltage (V) Output Current max (mA) Max. Capacitive Load (µF) Ripple & Noise typ. Efficiency (%) 1400 1500 620 500 1400 1500 620 500 1400 580 460 290 2000 2000 300 300 2000 2000 300 300 2000 300 300 300 80mV p-p 80mV p-p 120mV p-p 150mV p-p 80mV p-p 80mV p-p 120mV p-p 150mV p-p 80mV p-p 120mV p-p 150mV p-p 240mV p-p 76 82 84 84 76 82 84 84 80 80 81 81 Output Current max (mA) Max. Capacitive Load (µF) Ripple & Noise typ Efficiency (%) ±750 ±310 ±250 ±750 ±310 ±250 ±750 ±310 ±250 2000 300 300 2000 300 300 2000 300 300 80mV p-p 120mV p-p 150mV p-p 80mV p-p 120mV p-p 150mV p-p 80mV p-p 120mV p-p 150mV p-p 82 84 84 82 84 83 75 81 82 3.3 5 12 15 3.3 5 12 15 5 12 15 24 Models Dual output Model AM8TW-2405DIZ AM8TW-2412DIZ AM8TW-2415DIZ AM8TW-4805DIZ AM8TW-4812DIZ AM8TW-4815DIZ AM8TW-11005DIZ AM8TW-11012DIZ AM8TW-11015DIZ Input Voltage (V) 9-36 9-36 9-36 18-75 18-75 18-75 36-160 36-160 36-160 Output Voltage (V) ±5 ±12 ±15 ±5 ±12 ±15 ±5 ±12 ±15 Input Specifications Parameters Voltage range Conditions Typical 24 48 110 9-36 18-75 36-160 (Pi) Network Filter Absolute Maximum Rating 24 Vin 48 Vin Permissible absolute maximum duration Maximum Units VDC 40 83 2 VDC h Isolation Specifications Parameters Tested I/O voltage Resistance Capacitance www.aimtec.com F 051e R8.E Conditions 60 sec Typical > 1000 1000 Tel: +1 514 620 2722 1 of 3 Rated 1500 Units VDC MOhm pF Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM8TW-IZ 8 Watt | DC-DC Converter Output Specifications Parameters Voltage accuracy Short Circuit protection Short Circuit restart Over voltage protection Over load protection Line voltage regulation (Single) Line voltage regulation (Dual) Load voltage regulation (Single) Load voltage regulation (Dual) Temperature coefficient Conditions Typical Maximum ±2 HL-LL HL-LL 10-100% 10-100% Units % Continuous Auto recovery Zener diode clamp Over 110% full load with auto recovery ±0.5 ±0.5 ±0.5 ±2 ±0.05 % % % % %/ oC General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 300 KHz o Operating temperature Derating above 70 -40 to +75 C o Storage temperature -55 to +115 C o Max Case temperature 95 C o Derating Above 70 C Cooling Free air convection Humidity 95 % Case material Nickel coated copper Weight 16 g Dimensions (L x W x H) Tolerance ±0.5mm 1.25 x 0.80 x 0.40 inches 31.80 x 20.30 x 10.20 mm MTBF > 800 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC) NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Safety Specifications Standards Agency approvals Safety www.aimtec.com F 051e R8.E CE EN 55022: 2006 + A1: 2007 EN 55024: 1998 + A1:2001 + A2:2003 IEC 61000-4-2: 2008 IEC 61000-4-3: 2006 + A1: 2007 IEC 61000-4-4: 2004 IEC 61000-4-6: 2008 IEC 61000-4-8: 2009 Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM8TW-IZ 8 Watt | DC-DC Converter Dimensions Dual 2 3 9 10 11 14 15 16 22 23 -V Input -V Input N.C. Omitted N.C. +V Output Omitted -V Output +V Input +V Input -V Input -V Input Common Omitted -V Output +V Output Omitted Common +V Input +V Input 31.80 (1.25) 22.80 (0.90) 0.50 (0.02) 2 20.30 (0.80) Single 3 9 11 Bottom View 23 22 2.50 (0.10) 16 14 5.00 (0.20) Printed Face 3.80 (0.15) 10.20 (0.40) Pin 15.20 (0.60) Pin Out Specifications Derating D 400 LFM 85 ºC C 200 LFM 80 ºC B 100 LFM 75 ºC A Free Air 70 ºC A B C D Output Power (%) 100 80 Safe Operating Area 60 40 20 0 - 40 - 20 0 20 40 60 80 85 100 Ambient Temperature º C NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R8.E Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only