Click on Series name for product info on aimtec.com Series AM30KW-IZ 30 Watt | DC-DC Converter FEATURES: • Ultra-Wide 4:1 Input • Continuous Short Circuit Protection • Remote On/Off control • • • Standard package 2”x1.6” High efficiency up to 85% RoHS compliant Models Single output Input Voltage (V) Output Voltage (V) Output Current max (A) Isolation (VDC) Efficiency (%) AM30KW-2403SIZ AM30KW-2405SIZ AM30KW-2412SIZ AM30KW-2415SIZ AM30KW-2424SIZ AM30KW-4803SIZ AM30KW-4805SIZ AM30KW-4812SIZ AM30KW-4815SIZ AM30KW-4824SIZ 9-36 9-36 9-36 9-36 9-36 18-75 18-75 18-75 18-75 18-75 3.3 5 12 15 24 3.3 5 12 15 24 5.4 6 2.5 2 1.25 5.4 6 2.5 2 1.25 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 78 81 84 82 82 78 80 83 83 83 AM30KW-2403SH30IZ AM30KW-2405SH30IZ AM30KW-2412SH30IZ AM30KW-2415SH30IZ AM30KW-2424SH30IZ AM30KW-4803SH30IZ AM30KW-4805SH30IZ AM30KW-4812SH30IZ AM30KW-4815SH30IZ AM30KW-4824SH30IZ 9-36 9-36 9-36 9-36 9-36 18-75 18-75 18-75 18-75 18-75 3.3 5 12 15 24 3.3 5 12 15 24 5.4 6 2.5 2 1.25 5.4 6 2.5 2 1.25 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 78 81 84 82 82 78 80 83 83 83 Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VDC) Efficiency (%) AM30KW-2405DIZ AM30KW-2412DIZ AM30KW-2415DIZ AM30KW-4805DIZ AM30KW-4812DIZ AM30KW-4815DIZ 9-36 9-36 9-36 18-75 18-75 18-75 ±5 ±12 ±15 ±5 ±12 ±15 ±3 ±1.25 ±1 ±3 ±1.25 ±1 1500 1500 1500 1500 1500 1500 81 82 83 83 85 85 AM30KW-2405DH30IZ AM30KW-2412DH30IZ AM30KW-2415DH30IZ AM30KW-4805DH30IZ AM30KW-4812DH30IZ AM30KW-4815DH30IZ 9-36 9-36 9-36 18-75 18-75 18-75 ±5 ±12 ±15 ±5 ±12 ±15 ±3 ±1.25 ±1 ±3 ±1.25 ±1 3000 3000 3000 3000 3000 3000 81 82 83 83 85 85 Model Models Dual output Model NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. www.aimtec.com F 051e R12.B Tel: +1 514 620 2722 1 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30KW-IZ 30 Watt | DC-DC Converter Input Specifications Parameters Voltage range Filter Start up time Recommended input fuse (Slow Blow) Absolute Maximum Rating Nominal Typical 24 48 Maximum Units 9-36 18-75 π (Pi) Network VDC ms 24 48 24 48 4A/250V 2A/250V 50 100 Peak Input Voltage time On/Off control No Load Input Current VDC ms ON –TTL High or Open ; OFF – TTL Low or Short mA Isolation Specifications Parameters Tested I/O voltage Resistance Conditions Typical 3 sec 500VDC 1500 & 3000 >1000 Maximum Units VDC MOhm Output Specifications Parameters Conditions Typical Maximum Units ±2 % 4.1 6.51 15.75 18.9 28.35 VDC Voltage accuracy Zener diode clamp Over voltage Protection Over current protection Short Circuit protection Short circuit restart Line voltage regulation Load voltage regulation (Single) Load voltage regulation (Dual) Temperature coefficient Ripple & Noise Voltage adjustment range Minimum Load Current 3.3 Vout models 5 Vout models 12 Vout models 15 Vout models 24 Vout models 3.71 5.89 14.25 17.1 25.65 >110 % Continuous Auto Recovery HL-LL 25-100% 25-100% ±0.5 ±0.5 ±1 ±0.05 20MHz Bandwidth % of Vin % % o %/ C mV p-p % % of Max 150 ±10 25 General Specifications Parameters Switching frequency Operating temperature Storage temperature Maximum case temperature Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Maximum soldering temperature Transient recovery time Transient recovery deviation www.aimtec.com F 051e R12.B Conditions Typical 100% load With derating above 70ºC 250 Maximum Units 100 KHz o C o C o C -40 to +85 -55 to +105 Free Air Convection 95 Nickel coated copper with non-conductive base 50 2.00 x 1.60 x 0.40 inches 50.80 x 40.60 x 10.20 mm o > 550 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25 C) % RH g o 25% step change 280 Tel: +1 514 620 2722 2 of 5 C uS mS Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30KW-IZ 30 Watt | DC-DC Converter Safety Specifications Parameters Agency approvals Standards CE EN 55022, EN 55024 class A Pin Out Specifications Pin Single Dual 1 2 3 4 5 6 7 +V Input -V Input On/OFF Control No pin +V Output -V Output Trim +V Input -V Input On/OFF Control +V Output Common -V Output Trim Dimensions 5 1 2 Bottom View 6 3 7 45.72 (1.80) 10.16 (0.40) Printed Face www.aimtec.com F 051e R12.B Dimensions mm (inch) Case Tolerance ±0.50 (±0.02) Pin Pitch Tolerance ±0.35 (±0.014) Ø 1.00 (0.04) 5.60 (0.22) 2.54 (0.10) 10.16 10.16 10.16 (0.40) (0.40) (0.40) 4 5.10 (0.20) 40.60 (1.60) 7.62 10.16 5.08 (0.30) (0.40) (0.20) 17.78 (0.70) 5.10 (0.20) 50.80 (2.00) Tel: +1 514 620 2722 3 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30KW-IZ 30 Watt | DC-DC Converter Trimming Derating 1500VDC Isolation B 100 LFM 75 ºC A Free Air 70 ºC 3000VDC Isolation D 400 LFM 85 ºC C 200 LFM 80 ºC A B C Free Air Convection 40º C D 100 Output Power (%) Output Power (%) 100 80 Safe Operating Area 60 40 Safe Operating Area 60 40 20 20 0 0 - 40 80 - 20 0 20 40 60 80 85 100 - 40 - 20 F 051e R12.B 20 40 60 80 85 100 Ambient Temperature º C Ambient Temperature º C www.aimtec.com 0 Tel: +1 514 620 2722 4 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30KW-IZ 30 Watt | DC-DC Converter Control ON/OFF pin connection example Single Output Dual Output Digital Control Circuit: Control Voltage Vpeak On / Off Control 0.5mA NPN 0V Ra = Vpeak – 0.6 DC/DC Converter -V input 0.5mA NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4 . All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R12.B Tel: +1 514 620 2722 5 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only