MPD B1502RU B1500ru sery Datasheet

B1500RU Series
Ultra-Wide Input 15W
Single & Dual Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 15W Output Power
• 4:1 Input Voltage Range
• 1,500 VDC Isolation
• Compact 1 x 2 Inch Case
• Single & Dual Outputs
• Optional Remote ON/OFF
• Industry Standard Pin-Out
Input
Parameter
Input Start Voltage
Input Filter, See Note 1
Reverse Polarity Input Current
Short Circuit Input Power
Conditions
Min.
24 VDC Input
8.0
48 VDC Input 15.0
␲ (Pi) Filter
Typ.
8.5
17.0
Max.
9.0
18.0
Units
1.0
3,500
A
mW
Typ.
±1.0
±0.5
±0.1
±0.5
55
Max.
±2.0
±2.0
±0.5
±1.0
80
100
15
300
±2.0
±0.01
Continuous (Autorecovery)
500
±4.0
±0.02
Units
%
%
%
%
mV P - P
mV P - P
mV rms
%
µSec
%
%/°C
VDC
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Output Power Protection
Transient Recovery Time, See Note 3
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
Conditions
Min.
Dual Output , Balanced Loads
Vin = Min to Max
Iout = 10% to 100%
See Note 2
Over Line, Load & Temp.
120
25% Load Step Change
General
Parameter
Isolation Voltage
Isolation Test Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Remote On/Off See Note 4
Parameter
Supply On
Supply Off
Standby Input Current
Control Common
Conditions
60 Seconds
Flash Tested For 1 Sec
500 VDC
100 kHz, 1V
Min.
1,500
1,650
1,000
290
Conditions
Typ.
Max.
1,200
330
1,500
400
Min.
2.5
-0.7
Typ.
Min.
-40
Typ.
+25
Units
VDC
VDC
M⍀
pF
kHz
Max.
Units
5.5
VDC
0.8
VDC
10
mA
Referenced to Negative Input (pin 2)
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
RFI
Physical
Case Size
Case Material
Weight
Conditions
Max.
+60
+100
-50
+125
Free Air Convection (See Curves on Page 2)
RH, Non-condensing
95
Six-Side Shielded Metal Case
Ambient
Case
Units
°C
°C
°C
%
2.0 x 1.0 x 0.40 Inches (50.8 x 25.4 x 10.2 mm)
Metal with Non-Conductive Base
1.13 Oz (32g)
Reliability Specifications
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
700
Typ.
Max.
Units
kHours
Conditions
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
All Models
Min.
-0.7
-0.7
Typ.
Max.
50.0
100.0
260.0
5,000
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
°C
mW
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
B1501RU
B1502RU
B1503RU
B1504RU
B1505RU
B1506RU
B1507RU
B1511RU
B1512RU
B1513RU
B1514RU
B1515RU
B1516RU
B1517RU
Voltage (VDC)
Current (mA)
Nominal
Range
Full-Load No-Load
24
9.0 - 36.0
528
25
24
9.0 - 36.0
762
25
24
9.0 - 36.0
735
25
24
9.0 - 36.0
726
25
24
9.0 - 36.0
753
25
24
9.0 - 36.0
735
25
24
9.0 - 36.0
726
25
48
18.0 - 75.0
264
15
48
18.0 - 75.0
381
15
48
18.0 - 75.0
368
15
48
18.0 - 75.0
363
15
48
18.0 - 75.0
376
15
48
18.0 - 75.0
368
15
48
18.0 - 75.0
363
15
Reflected
Ripple
Current Voltage
(mA, Typ)
40
40
40
40
40
40
40
30
30
30
30
30
30
30
(VDC)
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
For Class “A” filter option, add suffix “F” to model number (i.e. B1503RU-F)
Output
Current
Current
(mA, Max)
(mA, Min)
3,000
3,000
1,250
1,000
±1,500
±625
±500
3,000
3,000
1,250
1,000
±1,500
±625
±500
Efficiency
(%, Typ)
300.0
300.0
125.0
100.0
±150.0
±62.5
±50.0
300.0
300.0
125.0
100.0
±150.0
±62.5
±50.0
Capacitive
Load
Fuse Rating
Slow-Blow
(µF Max)
(mA)
470
470
470
470
±220
±220
±220
470
470
470
470
±220
±220
±220
2,500
2,500
2,500
2,500
2,500
2,500
2,500
1,250
1,250
1,250
1,250
1,250
1,250
1,250
78
82
85
86
81
85
86
78
82
85
86
81
85
86
Derating Curve
For heatsink option, add suffix “H” to model number (i.e. B1503RU-H)
For Remote Control option, add suffix “R” to model number (i.e. B1503RU-R)
Notes:
1. An internal filter that complies with EN55022 Class “A” is available. Add a suffix “-F” to the model number
2. When measuring output ripple, it is recommended that an external 4.7 µF ceramic capacitor be placed
from the +Vout pin to the -Vout pin for single output units and from each output to common for dual
output units.
3. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%.
4. The maximum control current at the on/off pin (pin 6) during a logic high is 50 µA. The maximum control
current to the on/off pin at logic low (-0.7V to 0.8V) is 1 mA. If the on/off pin is left open, the unit operates.
If it is grounded, the unit will shut off.
5. Operation at no-load will not damage these units. However, they may not meet all specifications.
6. Dual output units may be connected to provide a 10 VDC, 24 VDC or 30 VDC output. To do this, connect
the load across the positive (+Vout) and negative (-Vout) outputs and float the output common.
7. The converter should be connected to a low ac-impedance source. An input source with a highly inductive
impedance may affect the stability of the converter.
In applications where the converter output loading is high and input power is supplied over long lines,
it may be necessary to use a capacitor on the input to insure start-up.
In this case, it is recommended that a low Equivalent Series Resistance (ESR <1.0⍀ at 100 kHz) capacitor
be mounted close to the converter. A 10.0 µF is recommended.
8. It is recommended that a fuse be used on the input of a power supply for protection. See the table above
for the correct rating.
Mechanical Dimensions
Pin Connections
Pin Single
1
+Vin
2
-Vin
3
+Vout
Dual
+Vin
-Vin
+Vout
Pin Single
Dual
4 No Pin Comm.
5
-Vout
-Vout
6 ON/OFF ON/OFF
Heatsink Dimensions (Optional)
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct