CLARE CPC1963G Ac power switch Datasheet

CPC1963
AC Power Switch
Parameter
Blocking Voltage
Load Current
On State Voltage Drop
Ratings
600
500
1.4
Units
VP
mArms
Vrms (at IL = 500mA)
Features
•
•
•
•
•
•
•
•
•
•
•
Load Current up to 0.5Arms
600VP Blocking Voltage
5mA Sensitivity
Zero-Crossing Detection
DC Control, AC Output
Optically Isolated
TTL and CMOS Compatible
Low EMI and RFI Generation
High Noise Immunity
Machine Insertable, Wave Solderable
Flammability classification rating of V-0
Description
The CPC1963 is an AC Solid State Switch using
optical coupling with dual power SCR outputs to
produce an alternative to optocoupler and Triac circuits.
The CPC1963 switches are robust enough to provide
a blocking voltage of up to 600VP. In addition, tightly
controlled zero cross circuitry ensures switching of AC
loads without the generation of transients. The input
and output circuits are optically coupled to provide
3750Vrms of isolation and noise immunity between
control and load circuits. As a result, the CPC1963
is well suited for industrial environments where
electromagnetic interference could disrupt the operation
of electromechanical relays.
Approvals
• UL 508 Recognized Component: File #: E69938
• CSA Certified Component: Certificate # 1172007
Applications
•
•
•
•
•
•
•
•
•
•
Programmable Control
Process Control
Power Control Panels
Remote Switching
Gas Pump Electronics
Contactors
Large Relays
Solenoids
Motors
Heaters
Ordering Information
Part Number
CPC1963G
CPC1963GS
CPC1963GSTR
Description
6-Pin DIP (50/Tube)
6-Pin Surface Mount (50/Tube)
6-Pin Surface Mount (1000/Reel)
Pin Configuration
1
6
+ LED
– LED
2
3
Pb
RoHS
2002/95/EC
DS-CPC1963-R04
ZC
5
AC Load
AC Load
4
e3
www.clare.com
1
CPC1963
Absolute Maximum Ratings
Parameter
Blocking Voltage
Reverse Input Voltage
Input Control Current
Peak (10ms)
Input Power Dissipation 1
Total Package Dissipation 2
Isolation Voltage, Input to Output
Operational Temperature
Storage Temperature
1
2
Ratings Units
600
VP
5
V
50
mA
1
A
150
mW
800
mW
3750
Vrms
-40 to +85
°C
-40 to +125
°C
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Derate Linearly 1.33 mW/˚C
Derate Linearly 6.67 mW/˚C
Electrical absolute maximum ratings are at 25°C
Electrical Characteristics
Parameter
Output Characteristics @ 25°C
Operating Voltage Range
Load Current, Continuous
Off State Leakage Current
On-State Voltage Drop
Critical Rate of Rise 3
Switching Speeds
Turn-on
Turn-off
Zero-Cross Turn-On Voltage 1
Operating Frequency
Load Power Factor for Guaranteed Turn-On 2
Input Characteristics @ 25°C
Input Control Current 4
Input Drop-out Voltage
Input Voltage Drop
Reverse Input Current
Common Characteristics @ 25°C
Input to Output Capacitance
Conditions
Symbol
Min
Typ
Max
Units
VT
VL=120Vrms
V = 600V
IL=500 mArms
-
IL
20
0.005
1000
-
260
0.5
1
1.4
-
Vrms
Arms
mA
Vrms
V/µs
20
0.25
2
1
-
0.5
0.5
10
500
-
0.23
1.2
-
5
1.4
10
mA
V
V
µA
3
-
pF
IF=5 mA
1st half cycle
Subsequent half cycle
-
ILEAK
VON
dV/dt
tON
tOFF
PF
IF=5mA
VR=5V
IF
VF
IR
0.8
0.9
-
-
CI/O
-
cycles
V
Hz
-
1
Zero Cross 1st half cycle @ <100Hz
2 Snubber circuits may be required at low power factors.
3 Tested in accordance with EIA/NARM standard RS-443.
4 For high noise environments use at least 10mA LED current.
2
www.clare.com
R04
CPC1963
PERFORMANCE DATA*
35
20
15
10
Device Count (N)
Device Count (N)
Device Count (N)
25
25
20
15
10
5
5
1.17
1.05
1.19
1.21
1.23
1.25
LED Forward Voltage Drop (V)
LED Current (mA)
20
15
10
5
1.06 1.07 1.08 1.09 1.10
Output Voltage Drop (Vrms)
0.24
0.25
0.26
0.278
0.276
0.30
0.274
0.25
0.20
0.15
0.10
70
1.04
1.02
0.98
0.96
25
40
55
70
Temperature (ºC)
85
25
40
55
70
Temperature (ºC)
40
70
85
1.8
1.6
1.4
I F = 50mA
I F = 20mA
1.2
I F = 10mA
I F = 5mA
1.0
0.8
-40
85
-20
0
20
40
60
80
Temperature (ºC)
100
120
dV/dt Method
Typical dV/dt vs. Temperature
Load Current, Free Air
1.2
55
Typical LED Forward Voltage Drop
vs. Temperature
1.00
620
0.268
LED Forward Voltage Drop (V)
630
0.270
25
1.06
640
670
Temperature (ºC)
Typical Output VON vs. Temperature
650
660
0.272
85
Typical Blocking Voltage
vs. Temperature
610
1400
Critical Rate of Rise (V/µs)
Load Current (Arms)
55
Temperature (ºC)
1.08
650
0.264
40
LED Current (mA)
660
640
0.266
25
1.10
630
Typical Leakage vs. Temperature
(VL=600VP)
0.35
670
620
Blocking Voltage (VP)
0.40
0.27
VON (Vrms)
Blocking Voltage (VP)
0.23
5
610
0
0
0.22
10
1.11
0.05
0.21
15
Typical IF for Switch Operation
vs. Temperature
Typical IF for Switch Operation
(TA=25ºC)
25
20
0
0
0
Typical Blocking Voltage Distribution
(TA=25ºC)
25
30
30
Device Count (N)
Typical On-State
Output Voltage Drop Distribution
(TA=25ºC)
Leakage (mA)
35
Typical LED Forward Voltage Drop
(TA=25ºC, IF=5mA)
1.0
0.8
RΘJA=60 ºC/W
0.6
0.4
0.2
1200
Vo
1000
Vo = 300V
dV 0.63 x 300V
dt
RC
800
63%
600
189
RC
In accordance with
EIA/NARM Standards
RS-443 for Solid State Relays
400
200
10%
0
0
-40
0
55
Temperature (ºC)
85
0
25
50
Temperature (ºC)
85
RC
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please
contact our application department.
R04
www.clare.com
3
CPC1963
Manufacturing Information
Soldering
For proper assembly, the component must be
processed in accordance with the current revision
of IPC/JEDEC standard J-STD-020. Failure to
follow the recommended guidelines may cause
permanent damage to the device resulting in impaired
performance and/or a reduced lifetime expectancy.
Washing
Clare does not recommend ultrasonic cleaning or the
use of chlorinated solvents.
Pb
RoHS
2002/95/EC
e3
MECHANICAL DIMENSIONS
6-Pin DIP Package
PC Board Pattern (Top View)
3.302 ± 0.051
(0.130 ± 0.002)
2.540 ± 0.127
(0.100 ± 0.005)
7.620 ± 0.254
(0.300 ± 0.010)
6.350 ± 0.127
(0.250 ± 0.005)
9.144 ± 0.508
(0.360 ± 0.020)
6 - 0.800 DIA.
(6 - 0.031 DIA.)
7.620 ± 0.127
(0.300 ± 0.005)
0.254 TYP.
(0.010 TYP.)
9.652 ± 0.381
(0.380 ± 0.015)
7.239 TYP.
(0.285 TYP.)
2.540 ± 0.127
(0.100 ± 0.005)
6.350 ± 0.127
(0.250 ± 0.005)
5.080 ± 0.127
(0.200 ± 0.005)
4.064 TYP.
(0.160 TYP.)
0.457 ± 0.076
(0.018 ± 0.003)
Dimensions
mm
(inches)
2.159 ± 0.102
(0.085 ± 0.004)
6-Pin Surface Mount Package
9.525 ± 0.254
(0.375 ± 0.010)
2.540 ± 0.127
(0.100 ± 0.005)
6.350 ± 0.127
(0.250 ± 0.005)
0.254 ± 0.0127
(0.010 ± 0.0005)
9.652 ± 0.381
(0.380 ± 0.015)
0.635 ± 0.127
(0.025 ± 0.005)
8.90
(0.350)
1.65
(0.065)
4.445 ± 0.127
(0.175 ± 0.005)
Dimensions
mm
(inches)
2.159 ± 0.102
(0.085 ± 0.004)
4
2.54
(0.10)
0.65
(0.0256)
7.620 ± 0.254
(0.300 ± 0.010)
0.457 ± 0.076
(0.018 ± 0.003)
3.302 ± 0.051
(0.130 ± 0.002)
Recommended PCB Land Pattern
www.clare.com
R04
CPC1963
MECHANICAL DIMENSIONS (Cont.)
Tape and Reel Packaging for 6-Pin Surface Mount Package
W = 16.30 max
(0.642 max)
330.2 DIA.
(13.00 DIA.)
Top Cover
Tape Thickness
0.102 MAX.
(0.004 MAX.)
1
6
Top Cover
Tape
K0 = 4.90
(0.193)
K1 = 4.20
(0.165)
Embossed Carrier
Embossment
P = 12.00
(0.472)
Ao = 10.30
(0.406)
User Direction of Feed
Bo = 10.30
(0.406)
Dimensions
mm
(inches)
NOTE: Tape dimensions not shown comply with JEDEC Standard EIA-481-2
For additional information please visit our website at: www.clare.com
Clare, Inc. makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes to specifications
and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in Clare’s Standard Terms and Conditions of
Sale, Clare, Inc. assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its products including, but not limited to, the implied warranty of merchantability,
fitness for a particular purpose, or infringement of any intellectual property right.
The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other
applications intended to support or sustain life, or where malfunction of Clare’s product may result in direct physical harm, injury, or death to a person or severe property or environmental
damage. Clare, Inc. reserves the right to discontinue or make changes to its products at any time without notice.
5
Specification: DS-CPC1963-R04
©Copyright 2009, Clare, Inc.
OptoMOS® is a registered trademark of Clare, Inc.
All rights reserved. Printed in USA.
8/28/09