Series AMEOF1-JZ O 1 Watt | AC-DC Converter Picture Coming Soon FEATURES: • • • • • • • • Input: 85-264VAC, 47-440Hz or 70-400VDC Operating temperature -40°C to +85°C Low power consumption ≤ 0.5W Continuous short circuit protection I/O Isolation 3000VAC Ultra slim open frame SIP Over current protection Class II power supply Models Single output Model AMEOF1-5SJZ AMEOF1-9SJZ AMEOF1-12SJZ AMEOF1-15SJZ AMEOF1-24SJZ Input Voltage (VAC/Hz) Input Voltage (VDC) Full power temperature range (ºC) Output Voltage (V) Output Current max (mA) Maximum capacitive load (µF) Efficiency (%) 85-264/47-440 85-264/47-440 85-264/47-440 85-264/47-440 85-264/47-440 70-400 70-400 70-400 70-400 70-400 -20 to +55 -20 to +55 -20 to +55 -20 to +55 -20 to +55 5 9 12 15 24 200 111 83 67 42 220 100 100 100 100 66 67 70 69 68 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Current Inrush current <2ms External fuse Input dissipation Input filter Conditions Typical 115VAC 230VAC 115VAC 230VAC Recommended slow blow type No Load Maximum Units 120 60 mA mA A A A W 9 15 1 0.5 Recommended external π (Pi) filter Output Specifications Parameters Voltage accuracy Line regulation Load regulation Ripple & Noise Hold-up time (min) Conditions Typical Full load, 5V output Full load, others Full load 5% - 100% load 20MHz Bandwidth 115VAC 230VAC Maximum Units ±8 ±5 % ±1.5 ±2.5 % % mV p-p ms ms % of Max 120 40 180 5 Minimum load current Isolation Specifications Parameters Tested I/O voltage Isolation Resistance Conditions Typical 60 sec Rated Units 3000 VAC MΩ >1000 General Specifications Parameters Switching frequency Over current protection Short circuit protection Short circuit restart Operating temperature Storage temperature www.aimtec.com F 052e R0 Conditions Typical 60 ≥110 Continuous Auto-recovery -40 to +85 -40 to +105 Auto-recovery See derating curve Tel: +1 514 620 2722 1 of 3 Maximum Units KHz % of I out °C °C Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEOF1-JZ O 1 Watt | AC-DC Converter General Specifications (continued) Parameters Conditions Temperature coefficient Cooling Humidity Weight Dimensions (L x W x H) MTBF Typical Maximum ±0.15 Free air convection 85 7 1.38 x 0.71 x 0.43 inches 35 x 18 x 11 mm o >200,000 hours (MIL-HDBK -217F, Ground Benign, t=+25 C) Units % / °C % RH g Safety Specifications Parameters Meets IEC 60950-1 EN 55022, Class A & B, with external filter circuits, as referenced IEC 61000-4-2, Contact ±4KV, Criteria B IEC 61000-4-3, 10V/m, Criteria A, with Class B external filter, as referenced IEC 61000-4-4, ±2KV/±4KV, Criteria B, with Class A/B external filter referenced IEC 61000-4-5, ±1KV/±2KV, Criteria B, with Class A/B external filter referenced IEC 61000-4-6, 10Vrms, Criteria A, with Class B external filter, as referenced IEC 61000-4-8, 10A/m, Criteria A IEC 61000-4-11, 0-70%, Criteria B Pin Out Specifications* * Add capacitor between pin 5 & 7. Application circuit below. 1 3 5 10 7 12 1.15 (0.05) 10.00 (0.39) 1.30 (0.05) 5.08 (0.20) Note: Unit: mm (inch) Pin diameter tolerance: ±0.10 (±0.004) Case tolerance: ±0.50 (±0.02) 27.94 (1.10) Derating* Free Air Convection at 25°C Free Air Convection 100 80 Output Power (%) Output Power (%) 100 Safe Operating Area 100% load 110-240VAC Or 100-340VDC 60 40 20 80 60 Safe Operating Area 40 20 0 - 40 11.00 (0.43) 18.00 (0.71) 1 3 5 7 10 12 1.75 (0.07) Pin Dimensions 35.00 (1.38) Single AC N AC L +V sc -V sc -V Output +V Output 0.50 (0.02) Standards - 20 0 20 40 55 60 80 85 0 100 85 110 (70) (100) Ambient Temperature º C 240 (340) 264 (400) Input Voltage VAC (VDC) *Power derating: -40 to -20 increase 1%/°C www.aimtec.com F 052e R0 Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEOF1-JZ O 1 Watt | AC-DC Converter 55 to 85 decrease 0.67%/°C Recommended EMC class A external circuit: AC L FUSE 1A/250V Single Output NTC L1 1mH MOV S14K350 C1 4.7µF/450V L2 2.2µH 12 3 +Vout 5 + AC + DC C2 7 AC N 1 C3 68µF/35V + TVS C4 0.1µF/50V 10 - Vout Pi filter CY1 1nF/400VAC Recommended EMC class B external circuit: AC L FUSE 1A/250V MOV S14K350 LDM 0.3mH LCM 3.5mH CX 0.1µF/ 275VAC AC N CY2 1nF/ 400VAC + CY3 1nF/ 400VAC L2 2.2µH 12 3 +Vout 5 C1 4.7µF/ 450V AC + DC 7 1 C2 C3 68µF/35V 10 + TVS C4 0.1µF/50V - Vout Pi filter GND Model 5 Vout 9 Vout 12 & 15 Vout 24 Vout Single Output CY1 1nF/400VAC C2 150 µF / 35V TVS 7V 12V 100 µF / 35V 20V 30V Note: For Safety compliance we recommend minimum PCB trace distance of 3mm, minimum distance between PCB traces of 6mm, primary to secondary circuit traces distance between minimum of 6.4mm. NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4 . All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052e R0 Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only