A Series 1-4 Pole Rotary Switches Features/Benefits • Multi-pole and multi-position • Positive detent • Shorting & non-shorting contacts • Panel and PCB mounting • RoHS Compliant Typical Applications • Automotive • Major and small appliances • Industrial equipment Models Available Specifications Materials CONTACT RATING: Q contact material: Switch - 2.5 AMPS @ 125 V AC; 350 mA @ 125 V DC (UL/CSA). Carry - 5 AMPS continuous. See page K-6 for additional ratings. ELECTRICAL LIFE: 15,000 make-and-break cycles at full load up to 300,000 detent operations. CONTACT RESISTANCE: Below 20 m Ω typ. initial @ 2-4 V DC, 100 mA, for both silver and gold plated contacts. INSULATION RESISTANCE: 10 9 Ω min. DIELECTRIC STRENGTH: 1,000 Vrms min. @ sea level. Operating and storage temp: -30º to 85ºC OPERATING & STORAGE TEMPERATURE: -30ºC to 85ºC HOUSING & BUSHING: Glass filled 6/6 nylon (UL 94V-0). ACTUATOR: Glass filled 6/6 nylon (UL 94V-0). MOVABLE CONTACTS: Q contact material: Coin silver, silver plated. See page K-6 for additional contact materials. STATIONARY CONTACTS & TERMINALS: Q contact material: Brass, silver plated. See page K-6 for additional contact materials. HARDWARE: Nut - zinc, nickel plated. Lockwasher — steel, bright zinc plated. Stop Ring - brass, nickel plated. TERMINAL SEAL: Epoxy. NOTE: Any models supplied with Q, B or G contact material are RoHS compliant. NOTE: Specifications and materials listed above are for switches with standard options. For information on specific and custom switches, consult Customer Service Center. Build-A-Switch To order, simply select desired option from each category and place in the appropriate box. Available options are shown and described on pages K–4 through K–7. For additional options not shown in catalog, consult Customer Service Center. K Dimensions are shown: Inch (mm) Specifications and dimensions subject to change K–3 www.ck-components.com Rotary Switch Function A100 SP, 30° Index, 12 pos. no stops A102 SPDT, 30° Index A103 SP, 30° Index, 3 pos. Actuator A104 SP, 30° Index, 4 pos. 15 1.500" high, flatted A105 SP, 30° Index, 5 pos. 03 .375" high, flatted A106 SP, 30° Index, 6 pos. 05 .500" high, flatted A107 SP, 30° Index, 7 pos. 14 1.500" high, flatted A108 SP, 30° Index, 8 pos. 42 1.654" high, metric A109 SP, 30° Index, 9 pos. S1 Screwdriver Slot A110 SP, 30° Index, 10 pos. A112 SP, 30° Index, 12 pos. Mounting Style A114 SP, 90° Index, 2 pos. R 3/8-32 threaded A115 SP, 45° Index, 3 pos. M M10 x .75 metric A124 SP, 90° Index, 4 pos. Shorting/ A125 SP, 45° Index, 8 pos. Non-shorting Contacts A203 DP, 30° Index, 3 pos. N Non-shorting contacts A204 DP, 30° Index, 4 pos. S Shorting contacts A205 DP, 30° Index, 5 pos. (Not available with models A114, A124 & A214) A206 DP, 30° Index, 6 pos. A214 DP, 90° Index, 2 pos. Terminations A303 3P, 30° Index, 3 pos. Z Solder lug A304 3P, 30° Index, 4 pos. C PC Thru-hole Contact Material A402 4PDT, 30° Index MC Modular base Q Silver A403 4P, 30° Index, 3 pos B Gold Seal G Gold over silver NONE No seal E Epoxy seal F Splashproof bushing seal K Epoxy & splashproof bushing seal A Series 1-4 Pole Rotary Switches SWITCH FUNCTION SP MODELS SCHEMATIC 30º INDEXING NO. POLES SP MODEL NO. SWITCH FUNCTION TERMINALS A100 12 Position No Stops A,1-12 A102 SPDT A,1,2* A103 3 Position A,1-3* A104 4 Position A,1-4* A105 5 Position A,1-5* A106 6 Position A,1-6* A107 7 Position A,1-7 A108 8 Position A,1-8 A109 9 Position A,1-9 A110 10 Position A,1-10 A112 12 Position A,1-12 A203 3 Position A,C,1-3,7-9 A204 4 Position A,C,1-4,7-10 A205 5 Position A,C,1-5,7-11 A206 6 Position A,C,1-12 A303 3 Position A,B,C,1-3,5-7 9-11 A304 4 Position A,B,C,1-12 30º INDEXING NO. POLES MODEL NO. SWITCH FUNCTION A402 4PDT A,B,C,D,1,2,4,5,7, 8,10,11 A403 3 Position All Terminals TERMINALS 4P DP MODELS SCHEMATIC 45º INDEXING NO. POLES MODEL NO. SWITCH FUNCTION A115 3 Position A,1,2,4* A125 8 Position A,1,2,4,5,7,8,10,11 TERMINALS SP 3P MODELS SCHEMATIC 90º INDEXING DP K MODEL NO. SWITCH FUNCTION A114 2 Position A,1,4* A124 4 Position A,1,4,7,10 A214 2 Position A,C,1,4,7,10 TERMINALS SP 3P Rotary NO. POLES 4P MODELS SCHEMATIC DP TERMINAL NUMBERS Terminal numbers molded on bottom of housing. NOTE: * These models with ‘C’ or ‘MC’ terminations have additional terminal no. 9 as switch support only. This terminal is not connected electrically inside switch. All models with all options when ordered with ‘G’ or ‘Q’ contact material, see page K-6. 4P MODELS SP MODELS (omit terminals B, C & D) DP MODELS (omit terminals B & D) 3P MODELS Dimensions are shown: Inch (mm) Specifications and dimensions subject to change K–4 www.ck-components.com A Series 1-4 Pole Rotary Switches ACTUATOR 15 03 1.500" HIGH .375" HIGH 05 14 .500" HIGH 1.500" HIGH 42 1.654" METRIC S1 SCREWDRIVER SLOT NOTE: Actuators shown in position 1, fully CCW. MOUNTING STYLE R M 3/8-32 THREAD M10 x .75 METRIC TYPICAL INSTALLATION Maximum force to push on knob should not exceed 10 in./lbs. NUT PANEL MOUNTING PANEL MOUNTING Install switch with stop ring (if used) and lockwasher in back of panel. Tighten hex nut from front of panel. On PC mounted switches, use hex nut and lockwasher to hold stop ring in place. Actuation torque: 8–16 oz./in. Maximum torque: 30 oz./in. 3/ 8 METRIC BUSHING IN. BUSHING SHORTING/NON-SHORTING CONTACTS N NON-SHORTING CONTACTS (break-before-make) S SHORTING CONTACTS (make-before-break) NOTE: ‘S’ shorting contacts are not available with A114, A124 and A214 models. Dimensions are shown: Inch (mm) Specifications and dimensions subject to change K–5 www.ck-components.com Rotary LOCKWASHER K A Series 1-4 Pole Rotary Switches TERMINATIONS Z C SOLDER LUG MC PC THRU-HOLE MODULAR BASE (for wave soldering) NOTE: Switches with ‘C’ or ‘MC’ terminations have additional terminal no. 9 as switch support only. This terminal is not connected electrically inside switch. Solder and clean switch base on PC board with other components, then snap on housing/actuator assembly. See page K-7 for installation instructions. PC MOUNTING 4P MODEL SP MODEL (omit terminals B, C & D) DP MODEL (omit terminals B & D) Rotary K 3P MODEL CONTACT MATERIAL OPTION CODE CONTACT AND TERMINAL MATERIAL RATING SWITCH-2.5 AMPS @ 125 V AC; 350 mA @ 125V DC (UL/CSA). CARRY-5 AMPS CONTINUOUS. Q SILVER 2 POWER B GOLD 1 LOW LEVEL/DRY CIRCUIT 0.4 VA MAX. @ 20 V AC or DC MAX LOW LEVEL/DRY CIRCUIT OR POWER 0.4 VA MAX. @ 20 V AC or DC MAX. or SWITCH-2.5 AMPS @ 125 V AC; 350 mA @ 125 V DC (UL/CSA). CARRY-5 AMPS CONTINUOUS. G GOLD OVER SILVER 3 * Note: See Technical Data section of this catalog for RoHS compliant and compatible definition and specifications. 1 MOVABLE CONTACTS: Copper alloy, with gold plate over nickel plate. STATIONARY CONTACTS & TERMINALS: Brass, with gold plate over nickel plate. MOVABLE CONTACTS: Coin silver, silver plated. STATIONARY CONTACTS & TERMINALS: Brass, silver plated (standard with all termination options). 3 MOVABLE CONTACTS: Coin silver, with gold plate over nickel plate over silver plate. STATIONARY CONTACTS & TERMINALS: Brass, with gold plate over nickel plate over silver plate. NOTE: Any models supplied with Q, B or G contact material are RoHS compliant. 2 All models with all options when ordered with ‘G’ or ‘Q’ contact material. NOTE: ‘G’ contact material is equivalent to both ‘B’ and ‘Q” contact materials. Dimensions are shown: Inch (mm) Specifications and dimensions subject to change K–6 www.ck-components.com A Series 1-4 Pole Rotary Switches FUNCTION NONE NO SEAL E EPOXY SEAL F SPLASHPROOF BUSHING SEAL K EPOXY & SPLASHPROOF BUSHING SEAL SPLASHPROOF BUSHING SEAL Setting Stops on A112 and A125 Models To set stops: Turn shaft fully counter-clockwise and insert stop ring tab in desired hole. Install lockwasher and nut to retain stop ring for both PC and panel mounting. Switch without stop ring has 12 positions. The number of switch positions is adjustable on A112 and A125 models only by means of a stop ring provided with each switch. The number of positions is pre-set on all other models and the stop ring is factory installed. Soldering, Cleaning and Assembly Instructions for ‘MC’ Termination Option Soldering 1. Insert switch base only into PC board. 2. Do not bend terminals. 3. Wave soldering recommended at 500F solder temperature. 4. Hand solder at 500F, 10 sec. max./terminal. Cleaning 1. Flux clean using vapor degreaser and forced rinse or triple bath method. 2. Do not allow switch base to ‘trap’ fluids. 3. Freon TMC, TF or Methylene Chloride give excellent results. REMOVABLE CLIP K Rotary Switch Assembly 1. Hold housing/shaft assembly by housing. Remove protective cap by squeezing tabs and discard. (FIG. 1) 2. Do not push on switch shaft. Detent mechanism will come apart. 3. While holding switch housing, align locating tab on base with notch on housing and engage 4 housing latches in slots on base. (FIG. 2) 4. Push firmly on housing until latches snap in place. 5. Remove clip from shaft and discard. Assembly is complete. (FIG. 3) (FIG. 1) LOCATING TAB STANDOFF (FIG. 2) (FIG. 3) AVAILABLE HARDWARE Stop ring PART NO. 767B00201 Material: Brass Finish: Nickel plated Dimensions are shown: Inch (mm) Specifications and dimensions subject to change K–7 www.ck-components.com