Diotec B40FD Fast switching si-bridge-rectifier Datasheet

B40FD ... B380FD
B40FD ... B380FD
Fast Switching Si-Bridge-Rectifiers
Schnelle Si-Brückengleichrichter
±0.2
1.3
Nominal current
Nennstrom
7.5
4.1
0.5
8.6
±0.3
8.5
~
1A
Alternating input voltage
Eingangswechselspannung
1.7
3.1±0.1
Version 2009-01-07
40...380 V
Plastic case DIL
Kunststoffgehäuse DIL
±0.4
8.3 x 6.4 x 3.1
[mm]
Weight approx. – Gewicht ca.
~
Type
Typ
0.4 g
Plastic material has UL classification 94V-0
Gehäusematerial UL94V-0 klassifiziert
+
Standard packaging: plastic tubes
Standard Lieferform: Plastik-Schienen
5.1
Dimensions - Maße [mm]
Recognized Product – Underwriters Laboratories Inc.® File E175067
Anerkanntes Produkt – Underwriters Laboratories Inc.® Nr. E175067
Maximum ratings
Type
Typ
Grenzwerte
Max. alternating input voltage
Max. Eingangswechselspannung
VVRMS [V]
Repetitive peak reverse voltage
Periodische Spitzensperrspannung
VRRM [V] 1)
B40FD
40
80
B80FD
80
160
B125FD
125
250
B250FD
250
600
B380FD
380
800
Repetitive peak forward current
Periodischer Spitzenstrom
f > 15 Hz
IFRM
10 A 2)
Peak forward surge current, 50/60 Hz half sine-wave
Stoßstrom für eine 50/60 Hz Sinus-Halbwelle
TA = 25°C
IFSM
40/44 A
Rating for fusing, t < 10 ms
Grenzlastintegral, t < 10 ms
TA = 25°C
i2t
Operating junction temperature – Sperrschichttemperatur
Storage temperature – Lagerungstemperatur
1
2
Tj
TS
8 A2s
-50...+150°C
-50...+150°C
Valid per diode – Gültig pro Diode
Max. temperature of the terminals TT = 100°C – Max. Temperatur der Anschlüsse TT = 100°C
© Diotec Semiconductor AG
http://www.diotec.com/
1
B40FD ... B380FD
Characteristics
Kennwerte
1.0 A 1)
0.8 A 1)
Max. average forward rectified current
Dauergrenzstrom
TA = 50°C
R-load
C-load
IFAV
IFAV
Forward voltage – Durchlass-Spannung
Tj = 25°C
IF = 1 A
VF
< 1.3 V 2)
Leakage current – Sperrstrom
Tj = 25°C
VR = VRRM
IR
< 10 µA
Reverse recovery time
Sperrverzug
IF = 0.5 A through/über
IR = 1 A to/auf IR = 0.25 A
trr
< 300 ns
Thermal resistance junction to ambient air
Wärmewiderstand Sperrschicht – umgebende Luft
Type
Typ
< 60 K/W1)
RthA
Max. admissible load capacitor
Max. zulässiger Ladekondensator
CL [µF]
Min. required protective resistor
Min. erforderl. Schutzwiderstand
Rt [Ω]
B40FD
2500
0.005
2.0
80
B80FD
1250
0.005
4.0
160
B125FD
800
0.005
6.3
250
B250FD
333
0.005
15.0
600
B380FD
250
0.005
20.0
800
120
2
10
[%]
[A]
100
10
80
Tj = 125°C
1
60
Tj = 25°C
40
10-1
20
IF
IFAV
0
0
TA
50
100
150
[°C]
0.4
Rated forward current versus ambient temperature
Zul. Richtstrom in Abh. von der Umgebungstemp.
1
2
2
40a-(1a-1.3v)
-2
10
VF
0.8
1.0
1.2
1.4
[V] 1.8
Forward characteristics (typical values)
Durchlasskennlinien (typische Werte)
Mounted on P.C. Board with 25 mm2 copper pads at each terminal
Montage auf Leiterplatte mit 25 mm2 Kupferbelag (Lötpad) an jedem Anschluss
Valid per diode – Gültig pro Diode