Sensortechnics CTEM9N01AF4 Oem pressure transmitters for industrial media Datasheet

CTE9000 / CTU9000 Series
OEM pressure transmitters for industrial media
FEATURES
· 0...0.35 to 0...35 bar, 0...5 to 0...500 psi
gage1 or absolute10
· 0...10 V, 0.5...4.5 V, 0...5 V, 1...6 V or
4...20 mA output
· Field interchangeable
· For industrial use
· All welded stainless steel diaphragm
construction
MEDIA COMPATIBILITY
Wetted materials:
stainless steel 1.4404 (316)9
Housing:
stainless steel, protection class IP 64 (according to
DIN EN 60529) respectively NEMA 4X1
ELECTRICAL CONNECTION
SPECIFICATIONS11,12
Maximum ratings
Supply voltage (reverse polarity protection)
CTE(M)/CTU9...0
12...32 V
CTE(M)/CTU9...1, ...6, ...7
9...32 V
CTE(M)/CTU9...42
9...32 V
0...10 V, 0.5...4.5 V, 0...5 V, 1...6 V output
+Vs
sensor
Maximum load current (source)
CTE(M)/CTU9...0, ...1, ...6, ...7
12 (9) to 32 V
1
Vout
2
-Vs
1 mA
V
GND
4
Temperature limits
Storage
Operating
Compensated
Humidity limits
Vibration (5 to 500 Hz)
Mechanical shock
-55 to 100°C
-40 to 100°C
0 to 70°C
December 2008 / 509
4...20 mA output
+Vs
0 - 98 %RH
10 gRMS
50 g
sensor
1
N/C
1000 mbar
15 psi
2 x rated pressure
9 to 32 V
2
V
-Vs
RL
4
3
Proof pressure
CTEM9350...
CTU9005...
all others
case
3
GND
case
3
1/6
www.sensortechnics.com
CTE9000 / CTU9000 Series
OEM pressure transmitters for industrial media
COMMON PERFORMANCE CHARACTERISTICS
Characteristics
Operating pressure
Min.
Typ.
Max.
CTEM9350...
0
0.35
CTE9001...
CTE9N01...
CTE9P01...
CTE9002...
CTE9003...
CTE9005...
CTE9010...
CTE9016...
CTE9020...
CTE9035...
0
-1
-1
0
0
0
0
0
0
0
1
1
0
2
3
5
10
16
20
35
CTU9005...
0
5
CTU9015...
CTU9N15...
CTU9P15
CTU9030...
CTU9050...
CTU9100...
CTU9300...
CTU9500...
0
-15
-15
0
0
0
0
0
15
15
0
30
50
100
300
500
Thermal effects
(0 to 70°C)4
Offset
Span
±0.02
±0.02
Thermal effects
(-40 to 0°C, 70 to 100°C)
Offset
Span
±0.03
±0.03
Non-linearity and hysteresis (BSL)5
±0.2
Repeatability
±0.1
Long term stability6
±0.1
±0.05
±0.05
Unit
bar
p si
%FSO/°C
±0.5
%FSO
Output noise (0 < f < 1 kHz)
±0.04
Response time (10 to 90 %)
1
Power supply rejection
December 2008 / 509
Offset
CTE(M)/CTU9...4
all others
±0.05
±0.002
Span
CTE(M)/CTU9...4
all others
±0.08
±0.002
ms
%FSO/V
2/6
www.sensortechnics.com
CTE9000 / CTU9000 Series
OEM pressure transmitters for industrial media
INDIVIDUAL PERFORMANCE CHARACTERISTICS
0...10 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Zero pressure offset
7
Full scale span
Min.
Typ.
Max.
CT...9N...
4.9
5
5.1
all others
-0.1
0
0.1
CT...9N...
4.9
5
5.1
all others
9.9
10
10.1
Unit
V
25
Ω
4
9.5
mA
Min.
Typ.
Max.
Unit
CT...9N...
2.45
2.5
2.55
all others
0.45
0.5
0.55
CT...9N...
1.95
2
2.05
all others
3.95
4
4.05
Output impedance
Current consumption (no load)
0.5...4.5 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Zero pressure offset
Full scale span7
V
25
Ω
4
8.5
mA
Min.
Typ.
Max.
Unit
CT...9N...
2.45
2.5
2.55
all others
-0.05
0
0.05
CT...9N...
2.45
2.5
2.55
all others
4.95
5.0
5.05
Output impedance
Current consumption (no load)
0...5 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Zero pressure offset
Full scale span7
25
Ω
4
8.5
mA
Unit
Output impedance
Current consumption (no load)
V
1...6 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Zero pressure offset
7
Full scale span
Min.
Typ.
Max.
CT...9N...
3.45
3.5
3.55
all others
0.95
1
1.05
CT...9N...
2.45
2.5
2.55
all others
4.95
5.0
5.05
V
25
Ω
4
8.5
mA
Min.
Typ.
Max.
Unit
CT...9N...
11.8
12.0
12.2
all others
3.8
4.0
4.2
CT...9N...
7.8
8.0
8.2
all others
15.8
16.0
16.2
Output impedance
Current consumption (no load)
4...20 mA output (VS = 15 V, RL = 100 Ω, tamb = 25°C)
Characteristics
Zero pressure offset
7
Full scale span
Power consumption (IL = 20 mA)
December 2008 / 509
260
mA
mW
3/6
www.sensortechnics.com
CTE9000 / CTU9000 Series
OEM pressure transmitters for industrial media
Specification notes:
1. IP 64 protection is given when the connector is locked. For proper function the gage port is vented to the atmosphere through
the connector/cable assembly. Thus the cable end must have access to the ambient pressure.
2. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the
load limitation diagram.
3. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.
4. Thermal effects tested and guaranteed from 0 to 70°C relative to 25°C. All specifications shown are relative to 25°C.
5. Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span.
6. Long term stability is the change in output after one year or 1 million pressure cycles.
7. Span is the arithmetic difference in transmitter output signal measured at zero pressure and the maximum operating pressure.
8. Tests are in accordance with EN61000-6-2, April 1999.
9. When using devices with optional nickel plated fittings, consider the media compatibility of the fittings also.
10. Available for pressure ranges from 1 bar (15 psi) absolute upwards only.
11. CE-labelling is in accordance with 89/336/EEC.
12. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC.
OUTLINE DRAWING
NOM 85.0 (3.35)
65.0 (2.56)
vent hole¹
4
G 1/8"
(BSP)
1
3
M12 x 1
21.8 (0.86)
diam.
6.5
(0.26)
Detail A
2
Detail A
4.0 (0.16)
diam.
Output
Pin
o-ring grove for
o-ring 11.8 x 1.8
(0.456 x 0.071)
(ZA004029)
mass: 82 g
December 2008 / 509
1
2
3
4
0...10 V
0.5...4.5 V
0...5 V, 1...6 V
+VS
Vout
case
-Vs
4...20 mA
+VS
NC
case
-Vs
dimensions in mm (inches)
4/6
www.sensortechnics.com
CTE9000 / CTU9000 Series
OEM pressure transmitters for industrial media
RECOMMENDED ACCESSORY (not included in delivery)
ZK000101:
ZP000112-B:
Connector/cable assembly (different cable lenghts available)
Mating Connector (without cable)
NOM 2 m
PIN CONNECTION
(other cable lenghts on request)
36.5
NOM 60
Shield
Pin
Flying lead end
1
Brown
2
Green
3
White and shield
4
Yellow
Vent tube
Note:
For proper function of all gage
devices the vent tube must have
access to the ambient atmosphere.
M12x1
Ø 20
OPTIONAL PRESSURE FITTINGS
(brass, nickel plated)
B
Male
fittings
dimensions in mm
LOAD LIMITATION
4...20 mA output version
1400
Ohm
1200
C
A
D
1000
800
G
F
Female
fittings
400
200
E
H
0
B
8 (0.315)
12 (0.472)
11.5 (0.453)
16 (0.630)
12.5 (0.492)
8.5 (0.335)
12.5 (0.492)
10 (0.394)
14 (0.551)
December 2008 / 509
C
13 (0.512)
5.5 (0.217)
5 (0.197)
7 (0.276)
11 (0.433)
5 (0.197)
7 (0.276)
13 (0.512)
6 (0.236)
5
9
16 20
25 30 32 V
supply voltage
Dimensions in mm (inches)
Dimensions in mm (inches)
A
1/8" BSPT
1/4" BSPT
3/8" BSPT
1/2" BSPT
1/8" BSP
1/4" BSP
3/8" BSP
1/8" NPT
1/4" NPT
op
e
ra ratin
ng g
e
600
D (Hex.)
14 (9/16")
14 (9/18")
17 (11/16")
22 (7/8")
14 (9/16")
19 (3/4")
22 (7/8")
17 (11/16")
22 (7/8")
E
1/8" BSP
1/4" BSP
3/8" BSP
1/2" BSP
F
5 (0.197)
7 (0.276)
6 (0.236)
18 (0.707)
G
15 (0.591)
20 (0.787)
20 (0.787)
23 (0.906)
H (Hex.)
14 (9/16")
17 (11/16")
22 (7/8")
24 (15/16")
5/6
www.sensortechnics.com
CTE9000 / CTU9000 Series
OEM pressure transmitters for industrial media
ELECTROMAGNETIC CAPABILITY8
Test conditions
Criterion Interference
Radiated, radio frequency
EN61000-4-3: Grade 3, 10 V/m, 80 to 1000 MHz
A
<1 %FSO
electromagnetic field immunity (RFI)
80 % AMC (1 kHz)
Electrical fast transient /
EN61000-4-4: Grade 3, ±2 kV
B
<1 %FSO
burst immunity (EFT)
Electrostatic discharge immunity
EN61000-4-2: Grade 4, ±8 kV, contact discharge
B
<1 %FSO
test (ESD)
Immunity to conducted disturbances EN61000-4-6: Grade 3, 0.15 to 80 MHz
A
<1 %FSO
induced by radio-frequency fields
10 V, 80 % AMC (1 kHz)
ORDERING INFORMATION
CTx
E:
U:
M
9xxx
x
x
x
bar calibration
psi calibration
Output signal
0:
0...10 V
1:
1...6 V
4:
4...20 mA
6:
0.5...4.5 V
7:
0...5 V
mbar-ranges
(only)
CTE9000 series
350: 0 to 350 mbar (gage only)
001:
0 to 1 bar
N01:
-1 to +1 bar (gage only)
P01:
-1 to 0 bar (gage only)
002:
0 to 2 bar
003:
0 to 3 bar
005:
0 to 5 bar
010:
0 to 10 bar
016:
0 to 16 bar
020:
0 to 20 bar
035:
0 to 35 bar
CTU9000 series
005:
0 to 5 psi (gage only)
015:
0 to 15 psi
N15: -15 to +15 psi (gage only)
P15:
-15 to 0 psi (gage only)
030:
0 to 30 psi
050:
0 to 50 psi
100:
0 to 100 psi
300:
0 to 300 psi
500:
0 to 500 psi
Pressure mode
G: gage pressure 1
A: absolute pressure
(available for pressure ranges from 1 bar /15 psi absolute upwards only)
Note:
Fitting size9
D: 1/8" BSPT
E: 1/4" BSPT
F: 3/8" BSPT
G: 1/2" BSPT
male,
male,
male,
male,
brass,
brass,
brass,
brass,
nickel
nickel
nickel
nickel
plated
plated
plated
plated
K:
L:
M:
N:
1/8"
1/4"
1/8"
1/4"
NPT male, brass
NPT male, brass
NPT male, SS 1.4305 (303)
NPT male, SS 1.4305 (303)
P:
Q:
R:
S:
G
G
G
G
1/8"
1/4"
3/8"
1/2"
(BSP)
(BSP)
(BSP)
(BSP)
male,
male,
male,
male,
U:
V:
W:
X:
G
G
G
G
1/8"
1/4"
3/8"
1/2"
(BSP)
(BSP)
(BSP)
(BSP)
female,
female,
female,
female,
Y:
G 1/8" (BSP) male, SS 1.4404 (316)
no optional fitting
brass,
brass,
brass,
brass,
nickel
nickel
nickel
nickel
brass,
brass,
brass,
brass,
plated
plated
plated
plated
nickel
nickel
nickel
nickel
plated
plated
plated
plated
Other pressure ranges and options are widely available.
Please contact your nearest Sensortechnics sales representative.
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the
application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
December 2008 / 509
6/6
www.sensortechnics.com
Similar pages