EPCOS B59100M1120A070 Motor protection, single sensor Datasheet

Sensors
B59100
Motor Protection, Single Sensors
M 1100
Applications
■ Thermal protection of winding in electric motors
■ Limit temperature monitoring
Features
■
■
■
■
■
Thermistor pellet with insulating encapsulation
Low-resistance type
Silver-plated and Teflon-insulated AWG 26 litz wires
Extremely fast response due to small dimensions
Characteristics for nominal threshold temperatures
of 90 up to 160 °C conform with DIN 44081
■ Color coding of litz wires to DIN 44081
Dimensions in mm
Delivery mode
■ Bulk
General technical data
Vmax
Max. operating voltage
(TA = 0 … 40 °C)
Max. measuring voltage
(TA – 25 K … TNTT + 23 K) Vmeas,max
Rated resistance
(V PTC ≤ 2,5 V)
RN
Insulation test voltage
Vins
Thermal threshold time
ta
Operating temperature range (V ≤ V meas, max)
Top
(V = Vmax)
Top
30
7,5
≤ 100
2,5
<3
– 25/ TNTT + 23
0/+ 40
VDC
VDC
Ω
kV AC
s
°C
°C
Electrical specifications and ordering codes
TNTT ± ∆T R (TNTT – ∆T)
(V PTC ≤ 2,5 V)
°C
Ω
≤ 570
60 ± 5
≤ 570
70 ± 5
80 ± 5
≤ 570
90 ± 5
≤ 550
≤ 550
100 ± 5
110 ± 5
≤ 550
120 ± 5
≤ 550
≤ 550
130 ± 5
140 ± 5
≤ 550
145 ± 5
≤ 550
≤ 550
150 ± 5
155 ± 5
≤ 550
160 ± 5
≤ 550
R (TNTT + ∆T)
(VPTC ≤ 2,5 V)
Ω
≥ 570
≥ 570
≥ 570
≥ 1330
≥ 1330
≥ 1330
≥ 1330
≥ 1330
≥ 1330
≥ 1330
≥ 1330
≥ 1330
≥ 1330
R (TNTT + 15 K)
(VPTC ≤ 7,5 V)
Ω
—
—
—
≥4k
≥4k
≥4k
≥4k
≥4k
≥4k
≥4k
≥4k
≥4k
≥4k
170 10/02
R (TNTT + 23 K)
(VPTC ≤ 2,5 V)
Ω
≥ 10 k
≥ 10 k
≥ 10 k
—
—
—
—
—
—
—
—
—
—
Ordering code
B59100M1060A070
B59100M1070A070
B59100M1080A070
B59100M1090A070
B59100M1100A070
B59100M1110A070
B59100M1120A070
B59100M1130A070
B59100M1140A070
B59100M1145A070
B59100M1150A070
B59100M1155A070
B59100M1160A070
Sensors
B59100
Motor Protection, Single Sensors
M 1100
Electrical specifications and ordering codes
TNTT ± ∆T R (TNTT – ∆T)
(V PTC ≤ 2,5 V)
°C
Ω
170 ± 7
≤ 570
180 ± 7
≤ 570
≤ 570
190 ± 7
R (TNTT + ∆T)
(VPTC ≤ 2,5 V)
Ω
≥ 570
≥ 570
≥ 570
R (TNTT + 15 K)
(VPTC ≤ 7,5 V)
Ω
—
—
—
R (TNTT + 23 K)
(VPTC ≤ 2,5 V)
Ω
≥ 10 k
≥ 10 k
≥ 10 k
Ordering code
B59100M1170A070
B59100M1180A070
B59100M1190A070
Color coding of litz wires (to DIN 44081)
°C
TNTT
60
70
80
90
100
110
Color
°C
TNTT
white/grey
white/brown
white/white
green/green
red/red
brown/brown
120
130
140
145
150
155
Color
°C
TNTT
grey/grey
blue/blue
white/blue
white/black
black/black
blue/black
160
170
180
190
Color
blue/red
white/green
white/red
black/grey
Characteristics (typical)
PTC resistance RPTC versus PTC temperature TPTC
(measured at low signal voltage)
TPT0853-H
10 8
Ω
R PTC
10 7
B59100M10*0A070
Ω
R PTC
10 7
10 6
10 6
10 5
10 5
10
TNTT
60 ˚C
70 ˚C
80 ˚C
4
10 3
10 2
10 2
30
50
B59100M1**0A070
TNTT
90 ˚C
100 ˚C
110 ˚C
10 4
10 3
10 1
10
TPT0854-Q
10 8
70
90
110 130 ˚C 160
T PTC
10 1
10
171 10/02
30
50
70
90 110 130 150 ˚C 180
T PTC
Sensors
B59100
Motor Protection, Single Sensors
M 1100
Characteristics (typical)
PTC resistance RPTC versus PTC temperature TPTC
(measured at low signal voltage)
TPT0855-Y
10 8
Ω
R PTC
10 7
R PTC
10 7
TNTT
120 ˚C
130 ˚C
140 ˚C
10 5
10 4
10 4
10 3
10 2
10 2
50
100
150
200 ˚C 250
T PTC
10 1
10
TPT0395-W
10 8
R PTC
10 7
B59100M11*0A070
TNTT
160 ˚C
170 ˚C
180 ˚C
190 ˚C
10 6
10 5
10 4
10 3
10 2
10 1
10
TNTT
145 ˚C
150 ˚C
155 ˚C
10 5
10 3
Ω
B59100M11**A070
10 6
10 6
10 1
10
TPT0394-N
10 8
Ω
B59100M11*0A070
50
100
150
200 ˚C 250
T PTC
172 10/02
50
100
150
200 ˚C 250
T PTC
Herausgegeben von EPCOS AG
Unternehmenskommunikation, Postfach 80 17 09, 81617 München, DEUTSCHLAND
++49 89 636 09, FAX (0 89) 636-2 26 89
(
 EPCOS AG 2002. Vervielfältigung, Veröffentlichung, Verbreitung und Verwertung dieser Broschüre und ihres Inhalts ohne ausdrückliche Genehmigung der EPCOS AG nicht gestattet.
Bestellungen unterliegen den vom ZVEI empfohlenen Allgemeinen Lieferbedingungen für Erzeugnisse und Leistungen der Elektroindustrie, soweit nichts anderes vereinbart wird.
Diese Broschüre ersetzt die vorige Ausgabe.
Fragen über Technik, Preise und Liefermöglichkeiten richten Sie bitte an den Ihnen nächstgelegenen Vertrieb der EPCOS AG
oder an unsere Vertriebsgesellschaften im Ausland. Bauelemente können aufgrund technischer Erfordernisse Gefahrstoffe enthalten. Auskünfte darüber bitten wir unter Angabe des betreffenden Typs ebenfalls über die zuständige Vertriebsgesellschaft einzuholen.
Published by EPCOS AG
Corporate Communications, P.O. Box 80 17 09, 81617 Munich, GERMANY
++49 89 636 09, FAX (0 89) 636-2 26 89
(
 EPCOS AG 2002. Reproduction, publication and dissemination of this brochure and the information contained therein without
EPCOS’ prior express consent is prohibited.
Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics
Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers’ Association), unless otherwise agreed.
This brochure replaces the previous edition.
For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or the international Representatives.
Due to technical requirements components may contain dangerous substances. For information on the type in question please
also contact one of our Sales Offices.
Similar pages