Eon EN39SL800-70BIP 8 megabit (512k x 16-bit) flash memory with 4kbytes uniform sector, cmos 1.8 volt-only Datasheet

EN39SL800
EN39SL800
8 Megabit (512K x 16-bit) Flash Memory With 4Kbytes Uniform Sector,
CMOS 1.8 Volt-only
FEATURES
•
-
• Single power supply operation
- Full voltage range: 1.65-1.95 volt for read and
write operations.
- Ideal for battery-powered applications.
• High performance
- Access times as fast as 70 ns
High performance program/erase speed
Word program time: 8µs typical
Sector erase time: 90ms typical
Block erase time: 180ms typical
Chip erase time: 2s typical
• JEDEC Standard Embedded Erase and
Program Algorithms
• Low power consumption (typical values at 5
MHz)
- 5 mA typical active read current
- 15 mA typical program/erase current
- 0.2 μA typical standby current
• JEDEC standard DATA# polling and toggle
bits feature
• Single Sector, Block and Chip Erase
• Erase Suspend / Resume modes:
Read or program another Sector/Block during
Erase Suspend Mode
• Uniform Sector Architecture:
- 256 sectors of 2-Kword
- 16 blocks of 32-Kword
- Any sector or block can be erased individually
• Low Vcc write inhibit < 1.2V
• Minimum 100K endurance cycle
• Block protection:
- Hardware locking of blocks to prevent
program or erase operations within
individual blocks
• Package Options
- 48-ball 6mm x 8mm TFBGA
- 48-ball 4mm x 6mm WFBGA
• Chip Unprotect Mode
• Industrial temperature Range
GENERAL DESCRIPTION
The EN39SL800 is an 8-Megabit, electrically erasable, read/write non-volatile flash memory,
organized as 524,288 words. Any word can be programmed typically in 8µs.The EN39SL800 features 1.8V
voltage read and write operation, with access time as fast as 70ns to eliminate the need for WAIT
statements in high-performance microprocessor systems.
The EN39SL800 has separate Output Enable (OE#), Chip Enable (CE#), and Write Enable (WE#) controls,
which eliminate bus contention issues. This device is designed to allow either single Sector/Block or full
chip erase operation, where each block can be individually protected against program/erase operations or
chip unprotected to erase or program. The device can sustain a minimum of 100K program/erase cycles on
each sector or block.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
1
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
CONNECTION DIAGRAMS
TFBGA
Top View, Balls Facing Down
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
2
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
WFBGA
Top View, Balls Facing Down
A6
A2
A5
A1
A4
A0
A3
CE#
A2
VSS
B6
A4
B5
A3
B4
A5
B3
DQ8
B2
OE#
B1
C6
A6
C5
A7
D6
A17
E6
NC
F6
G6
NC
NC
H5
D5
NC
NC
C4
A18
C1
H2
D2
NC
NC
D1
E1
F1
G1
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
3
DQ2
DQ12
H1
DQ13
J4
J3
DQ5
I1
DQ14
A15
K3
DQ11
I2
A14
K4
A12
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
K5
A13
A10
DQ4
VCC
DQ1
J5
I5
I3
DQ10
DQ9
A11
A9
A8
C3
C2
J6
I6
I4
DQ3
DQ0
WE#
H6
J2
A16
K2
DQ6
J1
DQ7
K1
DQ15
VSS
www.eonssi.com
EN39SL800
Table 1. PIN DESCRIPTION
Pin Name
A0-A18
Figure 1. LOGIC DIAGRAM
EN39SL800
Function
Addresses
A0 - A18
DQ0 – DQ15
DQ0-DQ15 16 Data Inputs/Outputs
CE#
CE#
Chip Enable
OE#
Output Enable
WE#
Write Enable
Vcc
Supply Voltage
(1.65-1.95V)
Vss
Ground
NC
Not Connected to anything
OE#
WE#
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
4
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
Table 2. Uniform Sector / Block Architecture (Block 8 ~ 15)
Address Range
Block
Sector Size
(Kwords)
Sector
(X16)
0
0
0
1
1
1
1
0
223
06F800h-06FFFFh
2
1
1
0
1
1
1
1
1
0
1
1
0
0
191
05F800h-05FFFFh
2
1
0
1
1
1
1
1
1
0
0
1
1
1
0
0
0
159
04F800h-04FFFFh
2
1
0
0
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
1
0
1
….
0
0
0
0
….
0
1
1
1
….
1
2
2
2
….
2
….
048000h-0487FFh
047800h-047FFFh
047000h-0477FFh
046800h-046FFFh
….
144
143
142
141
….
….
0
….
0
….
1
….
0
….
1
….
2
….
050000h-0507FFh
….
160
….
….
0
1
….
0
0
….
1
1
….
1
0
….
0
1
….
1
2
….
2
057800h-057FFFh
….
058000h-0587FFh
175
….
176
….
….
0
….
0
….
0
….
0
….
1
….
1
….
2
….
060000h-0607FFh
….
192
….
….
0
1
….
0
1
….
0
0
….
1
0
….
0
1
….
1
1
….
1
2
….
2
067800h-067FFFh
….
068000h-0687FFh
207
….
208
….
….
0
….
0
….
0
….
0
….
1
….
1
….
1
….
2
….
070000h-0707FFh
….
224
….
….
0
0
….
1
1
….
1
1
….
1
1
….
1
2
….
2
077800h-077FFFh
….
078000h-0787FFh
239
….
240
….
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
….
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
….
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
….
8
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
….
9
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
….
10
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
….
11
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
….
12
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
….
13
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
….
14
07F800h-07FFFFh
07F000h-07F7FFh
07E800h-07EFFFh
07E000h-07E7FFh
07D800h-07DFFFh
07D000h-07D7FFh
07C800h-07CFFFh
07C000h-07C7FFh
07B800h-07BFFFh
07B000h-07B7FFh
07A800h-07AFFFh
07A000h-07A7FFh
079800h-079FFFh
079000h-0797FFh
078800h-078FFFh
….
15
255
254
253
252
251
250
249
248
247
246
245
244
243
242
241
A18 A17 A16 A15 A14 A13 A12 A11
130
041000h-0417FFh
2
1
0
0
0
0
0
1
0
129
040800h-040FFFh
2
1
0
0
0
0
0
0
1
128
040000h-0407FFh
2
1
0
0
0
0
0
0
0
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
5
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
Table 2. Uniform Sector / Block Architecture (Block 0 ~ 7)
Address Range
Blaok
Sector Size
(Kwords)
Sector
0
1
1
1
1
1
0
1
0
1
….
….
….
….
….
….
….
….
….
114
113
039000h-0397FFh
038800h-038FFFh
2
2
0
0
1
1
1
1
1
1
0
0
0
0
1
0
0
1
….
….
….
….
….
030000h-0307FFh
2
0
1
1
0
0
0
0
0
95
02F800h-02FFFFh
2
0
1
0
1
1
1
1
1
….
….
….
….
….
96
….
1
….
0
1
….
0
1
….
0
1
….
0
0
….
1
1
….
1
1
….
1
0
….
0
2
….
2
037800h-037FFFh
….
038000h-0387FFh
111
….
112
….
….
….
….
….
64
020000h-0207FFh
2
0
1
0
0
0
0
0
0
63
01F800h-01FFFFh
2
0
0
1
1
1
1
1
1
….
….
….
….
….
0
1
….
0
1
….
0
1
….
0
1
….
1
0
….
0
0
….
1
1
….
0
0
….
2
2
….
028000h-0287FFh
027800h-027FFFh
….
80
79
….
….
….
….
32
010000h-0107FFh
2
0
0
1
0
0
0
0
0
31
00F800h-00FFFFh
2
0
0
0
1
1
1
1
1
….
….
….
0
1
….
0
1
….
0
1
….
0
1
….
1
0
….
1
1
….
0
0
….
0
0
….
2
2
….
018000h-0187FFh
017800h-017FFFh
….
48
47
….
1
1
1
1
….
2
1
1
1
….
3
1
1
1
….
4
1
1
1
….
5
0
0
0
….
6
2
2
2
….
7
03F800h-03FFFFh
03F000h-03F7FFh
03E800h-03EFFFh
….
127
126
125
A18 A17 A16 A15 A14 A13 A12 A11
….
(X16)
16
008000h-0087FFh
2
0
0
0
1
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
007800h-007FFFh
007000h-0077FFh
006800h-006FFFh
006000h-0067FFh
005800h-005FFFh
005000h-0057FFh
004800h-004FFFh
004000h-0047FFh
003800h-003FFFh
003000h-0037FFh
002800h-002FFFh
002000h-0027FFh
001800h-001FFFh
001000h-0017FFh
000800h-000FFFh
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
000000h-0007FFh
2
0
0
0
0
0
0
0
0
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
6
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
PRODUCT SELECTOR GUIDE
Product Number
Speed Option
EN39SL800
Full Voltage Range: Vcc=1.65 – 1.95 V
-70
Max Access Time, ns (tacc)
70
Max CE# Access, ns (tce)
70
Max OE# Access, ns (toe)
30
BLOCK DIAGRAM
Vcc
Vss
DQ0-DQ15
Block Protect Switches
Erase Voltage Generator
Input/Output Buffers
State
Control
WE#
Command
Register
Program Voltage
Generator
Chip Enable
Output Enable
Logic
CE#
OE#
Vcc Detector
Timer
Address Latch
STB
STB
Data Latch
Y-Decoder
Y-Gating
X-Decoder
Cell Matrix
A0-A18
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
7
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
Table 3. OPERATING MODES
8M FLASH USER MODE TABLE
Operation
Read
Write
CMOS Standby
Output Disable
CE#
L
L
Vcc ± 0.2V
L
OE#
L
H
X
H
WE#
H
L
X
H
Block Protect
L
H
L
Chip Unprotect
L
H
L
A0-A18
AIN
AIN
X
X
DQ0-DQ15
DOUT
DIN
High-Z
High-Z
Block Address, A6
= L, A1 = H,
A0 = L
Block Address, A6
= L, A1 = H,
A0 = L
DIN
DIN
Notes:
L=logic low= VIL, H=Logic High= VIH, VID =10.0 ± 1.0V, X=Don’t Care (either L or H, but not floating!),
DIN=Data In, DOUT=Data Out, AIN=Address In
Table 4. DEVICE IDENTIFICTION (Autoselect Codes)
8M FLASH MANUFACTURER/DEVICE ID TABLE
Description
CE# OE# WE#
A18
to
A12
A11
to
A10
A9
2
A8
A7
A6
A5
to
A2
A1
A0
DQ8
to
DQ15
X
L
X
L
L
X
27h
1
H
Manufacturer ID:
Eon
L
L
H
X
X
VID
Device ID
L
L
H
X
X
VID
X
X
L
X
L
H
Block Protection
Verification
L
L
H
SA
X
VID
X
X
L
X
H
L
L
X
X
DQ7 to
DQ0
1Ch
7Fh
3Fh
01h
(Protected)
00h
(Unprotected)
Note:
1. A8=H is recommended for Manufacturing ID check. If a manufacturing ID is read with A8=L, the chip will output a configuration code
7Fh.
2. A9 = VID is for HV A9 Autoselect mode only. A9 must be ≤ Vcc (CMOS logic level) for Command Autoselect Mode.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
8
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
USER MODE DEFINITIONS
Standby Mode
The EN39SL800 has a CMOS-compatible standby mode, which reduces the current to < 0.2µA (typical). It
is placed in CMOS-compatible standby when the CE# pin is at VCC ± 0.2. When in standby modes, the
outputs are in a high-impedance state independent of the OE# input.
Read Mode
The device is automatically set to reading array data after device power-up. No commands are required to
retrieve data. The device is also ready to read array data after completing an Embedded Program or
Embedded Erase algorithm.
After the device accepts an Erase Suspend command, the device enters the Erase Suspend mode. The
system can read array data using the standard read timings, except that if it reads at an address within
erase-suspended sectors/blocks, the device outputs status data. After completing a programming operation
in the Erase Suspend mode, the system may once again read array data with the same exception. See
“Erase Suspend/Erase Resume Commands” for more additional information.
The system must issue the reset command to re-enable the device for reading array data if DQ5 goes high,
or while in the autoselect mode. See the “Reset Command” additional details.
Output Disable Mode
When the OE# pin is at a logic high level (VIH), the output from the EN39SL800 is disabled. The output
pins are placed in a high impedance state.
Auto Select Identification Mode
The autoselect mode provides manufacturer and device identification, and block protection verification,
through identifier codes output on DQ15–DQ0. This mode is primarily intended for programming equipment
to automatically match a device to be programmed with its corresponding programming algorithm. However,
the autoselect codes can also be accessed in-system through the command register.
When using programming equipment, the autoselect mode requires VID ( 9.0 V to 11.0 V) on address pin
A9. Address pins A8, A6, A1, and A0 must be as shown in Autoselect Codes table. In addition, when
verifying block protection, the block address must appear on the appropriate highest order address bits.
Refer to the corresponding block Address Tables. The Command Definitions table shows the remaining
address bits that are don’t-care. When all necessary bits have been set as required, the programming
equipment may then read the corresponding identifier code on DQ15–DQ0.
To access the autoselect codes in-system; the host system can issue the autoselect command via the
command register, as shown in the Command Definitions table. This method does not require VID. See
“Command Definitions” for details on using the autoselect mode.
Write Mode
Write operations, including programming data and erasing sectors/blocks of memory, require the host
system to write a command or command sequence to the device. Write cycles are initiated by placing the
word address on the device’s address inputs while the data to be written is input on DQ [15:0] in Word
Mode. The host system must drive the CE# and WE# pins Low and the OE# pin High for a valid write
operation to take place. All addresses are latched on the falling edge of WE# and CE#, whichever happens
later. All data is latched on the rising edge of WE# or CE#, whichever happens first. The system is not
required to provide further controls or timings. The device automatically provides internally generated
program / erase pulses and verifies the programmed /erased cells’ margin. The host system can detect
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
9
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
completion of a program or erase operation by reading the DQ[7] (Data# Polling) and DQ[6] (Toggle) status
bits.
The ‘Command Definitions’ section of this document provides details on the specific device commands
implemented in the EN39SL800.
Block Protection and Chip Unprotection
The EN39SL800 includes the hardware block protection feature, which disables both program and erase
operations in any block. The block protect feature is enabled using programming equipment at the user’s
site. Block is unprotected when the devices are shipped.
Block Protection
To activate the block protection mode, the programming equipment must force VID on address pin A9 and
control pin OE#, (VID=10V ± 1.0V), CE# = WE# = VIL. The block addresses (A18-A15) should be set to the
block to be protected while (A6, A1, A0) = (VIL, VIH, VIL). Programming of the protection circuitry begins on
the falling edge and is terminated with the rising edge of the WE# pulse. Addresses must be held constant
during the WE# pulse. Please see Flowchart 7a for Block Protection Algorithms and Figure 11 for the
waveform of timings.
Verification of the protection circuitry requires the programming equipment to apply VID on address pin A9
while OE# is set at VIL, WE# is at VIH and (A6, A1, A0) = (VIL, VIH, VIL). To check for block protection,
scanning of A18 – A15 while (A6, A1, A0) = (VIL, VIH, VIL) and activating CE# will produce 01H at the
device’s outputs (DQ0 – DQ7). During this mode, the lower addresses (except for A0, A1, and A6) are
don’t care (can be VIL or VIH but not floating).
The unspecified addresses are don’t care which means they can be VIL, or VIH, but should not be floating.
We also recommend that the data pins also be at VIL or VIH during the time that WE# is at VIL.
Chip Unprotection
Previously protected blocks can be unprotected using the chip unprotection algorithm as seen in Flowchart
7b and Figure 12 for the waveform of timings. All blocks must be placed in the protection mode using
protection algorithm mentioned above before unprotection can be executed.
To activate the chip unprotection mode, the programming equipment must force VID on address pin A9 and
control pin OE#, (VID=10V ± 1.0V), CE# = WE# = VIL. And set addresses (A6, A1, A0) = (VIH, VIH, VIL). The
unprotection circuitry is then invoked by keeping WE# at VIL for a length of tWPP2.
To determine if unprotection is complete, each block must be verified. The chip unprotect verify mode is
entered by setting OE#=VIL, WE#=VIH, and raising A9 to VID. The unprotection status can then be read
from DQ0-DQ7 by setting block address bits A18-A15 to the desired block address, and A6=1, A1=1, A0=0,
and CE# to VIL. A 00h on DQ0-DQ7 indicates that unprotection of that particular block is complete;
otherwise repeat the process by re-entering the unprotection mode and re-invoking the unprotection
circuitry for a period of tWPP2. Repeat the process also if the unprotection status of any other blocks does
not indicate 00h on DQ0-DQ7. When DQ0-DQ7 reads 00h for all blocks, chip unprotection is complete.
Automatic Sleep Mode
The automatic sleep mode minimizes Flash device energy consumption. The device automatically enables
this mode when addresses remain stable for tacc + 30ns. The automatic sleep mode is independent of the
CE#, WE# and OE# control signals. Standard address access timings provide new data when addresses
are changed. While in sleep mode, output is latched and always available to the system. Icc4 in the DC
Characteristics table represents the automatic sleep mode current specification.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
10
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
COMMON FLASH INTERFACE (CFI)
The Common Flash Interface (CFI) specification outlines device and host systems software interrogation
handshake, which allows specific vendor-specified software algorithms to be used for entire families of
devices. Software support can then be device-independent, JEDEC ID-independent, and forward- and
backward-compatible for the specified flash device families. Flash vendors can standardize their existing
interfaces for long-term compatibility.
This device enters the CFI Query mode when the system writes the CFI Query command, 98h, to address
55h in word mode, any time the device is ready to read array data.
The system can read CFI information at the addresses given in Tables 5-7. In word mode, the upper
address bits (A7–MSB) must be all zeros. To terminate reading CFI data, the system must write the reset
command.
The system can also write the CFI query command when the device is in the autoselect mode. The device
enters the CFI query mode and the system can read CFI data at the addresses given in Tables 5–8. The
system must write the reset command to return the device to the autoselect mode.
Table 5. CFI Query Identification String (1)
Adresses
(Word Mode)
10h
11h
12h
13h
14h
15h
16h
17h
18h
19h
1Ah
Data
0051h
0052h
0059h
0002h
0000h
0040h
0000h
0000h
0000h
0000h
0000h
Description
Query Unique ASCII string “QRY”
Primary OEM Command Set
Address for Primary Extended Table
Alternate OEM Command set (00h = none exists)
Address for Alternate OEM Extended Table (00h = none exists)
1. Refer to CFI publication 100 for more details.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
11
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
Table 6. System Interface String
Addresses
(Word Mode)
Data
1Bh
0016h
1Ch
0020h
1Dh
1Eh
1Fh
0000h
0000h
0004h
20h
0000h
21h
22h
23h
24h
25h
000Ah
0000h
0005h
0000h
0004h
26h
0000h
Description
Vcc Min (write /erase)
DQ7-DQ4: volts, DQ3 –DQ0: 100 millivolts
Vcc Max (write /erase)
DQ7-DQ4: volts, DQ3 –DQ0: 100 millivolts
Vpp Min. voltage (00h = no Vpp pin present)
Vpp Max. voltage (00h = no Vpp pin present)
N
Typical timeout per single word program 2 μs
N
Typical timeout for Min, size buffer write 2 μs (00h = not
supported)
N
Typical timeout per individual sector/block erase 2 ms
N
Typical timeout for full chip erase 2 ms (00h = not supported)
N
Max. timeout for word write 2 times typical
N
Max. timeout for buffer write 2 times typical
N
Max. timeout per individual sector/block erase 2 times typical
N
Max timeout for full chip erase 2 times typical (00h = not
supported)
Table 7. Device Geometry Definition
Addresses
(Word mode)
27h
2Ah
2Bh
2Ch
2Dh
2Eh
2Fh
30h
31h
32h
33h
34h
Data
0014h
0000h
0000h
0002h
00FFh
0000h
0010h
0000h
000Fh
0000h
0000h
0001h
Description
20
Device Size = 2 byte (14h = 20; 2 = 1MByte)
N
Max. number of byte in multi-byte write = 2
(00h = not supported)
Number of Erase Sector/Block Regions within device
Erase Sector Region 1 Information
(y+1 = Number of sectors; z x 256B = sector size)
y = 255 + 1 = 256 sectors (00FFh = 255)
z = 16 x 256 Bytes = 4 KByte/sector (0010h = 16)
Erase Block Region 2 Information
(y+1 = Number of blocks; z x 256B = block size)
y = 15 + 1 = 16 blocks (000Fh = 15)
z = 256 x 256 Bytes = 64 KByte/block (0100h = 256)
N
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
12
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
Hardware Data Protection
The command sequence requirement of unlock cycles for programming or erasing provides data
protection against inadvertent writes as seen in the Command Definitions table. Additionally, the
following hardware data protection measures prevent accidental erasure or programming, which might
otherwise be caused by false system level signals during Vcc power up and power down transitions, or
from system noise.
Low VCC Write Inhibit
When Vcc is less than VLKO, the device does not accept any write cycles. This protects data during Vcc
power up and power down. The command register and all internal program/erase circuits are disabled,
and the device resets. Subsequent writes are ignored until Vcc is greater than VLKO. The system must
provide the proper signals to the control pins to prevent unintentional writes when Vcc is greater than VLKO.
Write Pulse “Glitch” protection
Noise pulses of less than 5 ns (typical) on OE#, CE# or WE# do not initiate a write cycle.
Logical Inhibit
Write cycles are inhibited by holding any one of OE# = VIL, CE# = VIH, or WE# = VIH. To initiate a write
cycle, CE# and WE# must be a logical zero while OE# is a logical one. If CE#, WE#, and OE# are all
logical zero (not recommended usage), it will be considered a read.
Power-up Write Inhibit
During power-up, the device automatically resets to READ mode and locks out write cycles. Even with
CE# = VIL, WE# = VIL and OE# = VIH, the device will not accept commands on the rising edge of WE#.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
13
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
COMMAND DEFINITIONS
The operations of EN39SL800 are selected by one or more commands written into the command register
to perform Read/Reset Memory, Read ID, Read Block Protection, Program, Sector/Block Erase, Chip
Erase, Erase Suspend and Erase Resume. Commands are made up of data sequences written at specific
addresses via the command register. The sequences for the specified operation are defined in the
Command Definitions table (Table 5). Incorrect addresses, incorrect data values or improper sequences
will reset the device to Read Mode.
Table 8. EN39SL800 Command Definitions
Command
Sequence
Cycles
Bus Cycles
st
nd
rd
2
6
Cycle
Addr Data
Cycle
Addr Data
RD
Reset
1
xxx
F0
Manufacturer ID
4
555
AA
2AA
55
555
Device ID
4
555
AA
2AA
55
555
Block Protect Verify
4
555
AA
2AA
55
Program
4
555
AA
2AA
Sector Erase
6
555
AA
Block Erase
6
555
AA
Chip Erase
6
555
AA
Autoselect
RA
1
xxx
B0
1
xxx
30
CFI Query
1
55
98
th
5
Cycle
Addr Data
1
Erase Resume
th
4
Cycle
Addr
Data
Read
Erase Suspend
th
3
Cycle
Addr Data
1
Cycle
Addr Data
000
7F
100
1C
90
X01
273F
555
90
(BA)
X02
XX00
55
555
A0
PA
PD
2AA
55
555
80
555
AA
2AA
55
SA
30
2AA
55
555
80
555
AA
2AA
55
BA
50
2AA
55
555
80
555
AA
2AA
55
555
10
90
XX01
Address and Data values indicated in hex
RA = Read Address: address of the memory location to be read. This is a read cycle.
RD = Read Data: data read from location RA during Read operation. This is a read cycle.
PA = Program Address: address of the memory location to be programmed. X = Don’t-Care
PD = Program Data: data to be programmed at location PA
BA = Block Address: address of the Block to be erased or verified. Address bits A18-A15 uniquely select any Block
SA = Sector Address: address of the Sector to be erased or verified. Address bits A18-A11 uniquely select any Sector
Reading Array Data
The device is automatically set to reading array data after power up. No commands are required to
retrieve data. The device is also ready to read array data after completing an Embedded Program or
Embedded Erase algorithm.
Following an Erase Suspend command, Erase Suspend mode is entered. The system can read array
data using the standard read timings, with the only difference in that if it reads at an address within erase
suspended sectors/blocks, the device outputs status data. After completing a programming operation in
the Erase Suspend mode, the system may once again read array data with the same exception.
The Reset command must be issued to re-enable the device for reading array data if DQ5 goes high, or
while in the autoselect mode. See next section for details on Reset.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
14
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
Reset Command
Writing the reset command to the device resets the device to reading array data. Address bits are don’tcare for this command.
The reset command may be written between the sequence cycles in an erase command sequence before
erasing begins. This resets the device to reading array data. Once erasure begins, however, the device
ignores reset commands until the operation is complete. The reset command may be written between the
sequence cycles in a program command sequence before programming begins. This resets the device to
reading array data (also applies to programming in Erase Suspend mode). Once programming begins,
however, the device ignores reset commands until the operation is complete.
The reset command may be written between the sequence cycles in an autoselect command sequence.
Once in the autoselect mode, the reset command must be written to return to reading array data (also
applies to autoselect during Erase Suspend).
If DQ5 goes high during a program or erase operation, writing the reset command returns the device to
reading array data (also applies during Erase Suspend).
Autoselect Command Sequence
The autoselect command sequence allows the host system to access the manufacturer and devices
codes, and determine whether or not a block is protected. The Command Definitions table shows the
address and data requirements. This is an alternative to the method that requires VID on address bit A9
and is intended for PROM programmers.
Two unlock cycles followed by the autoselect command initiate the autoselect command sequence.
Autoselect mode is then entered and the system may read at addresses shown in Table 4 any number of
times, without needing another command sequence.
The system must write the reset command to exit the autoselect mode and return to reading array data.
Programming Command
Programming the EN39SL800 is performed by using a four bus-cycle operation (two unlock write cycles
followed by the Program Setup command and Program Data Write cycle). When the program command
is executed, no additional CPU controls or timings are necessary. An internal timer terminates the
program operation automatically. Address is latched on the falling edge of CE# or WE#, whichever is last;
data is latched on the rising edge of CE# or WE#, whichever is first.
Programming status may be checked by sampling data on DQ7 (DATA# polling) or on DQ6 (toggle bit).
When the program operation is successfully completed, the device returns to read mode and the user can
read the data programmed to the device at that address. Note that data can not be programmed from a 0
to a 1. Only an erase operation can change a data from 0 to 1. When programming time limit is exceeded,
DQ5 will produce a logical “1” and a Reset command can return the device to Read mode.
Chip Erase Command
Chip erase is a six-bus-cycle operation. The chip erase command sequence is initiated by writing two
unlock cycles, followed by a set-up command. Two additional unlock write cycles are then followed by the
chip erase command, which in turn invokes the Embedded Erase algorithm. The device does not require
the system to preprogram prior to erase. The Embedded Erase algorithm automatically preprograms and
verifies the entire memory for an all zero data pattern prior to electrical erase. The system is not required
to provide any controls or timings during these operations. The Command Definitions table shows the
address and data requirements for the chip erase command sequence.
Any commands written to the chip during the Embedded Chip Erase algorithm are ignored.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
15
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
The system can determine the status of the erase operation by using DQ7, DQ6, or DQ2. See “Write
Operation Status” for information on these status bits. When the Embedded Erase algorithm is complete,
the device returns to reading array data and addresses are no longer latched.
Flowchart 4 illustrates the algorithm for the erase operation. See the Erase/Program Operations tables in
“AC Characteristics” for parameters, and to the Chip, Sector/Block Erase Operation Timings for timing
waveforms.
Sector/Block Erase Command Sequence
Sector/Block erase is a six bus cycle operation. The sector/block erase command sequence is initiated by
writing two un-lock cycles, followed by a set-up command. Two additional unlock write cycles are then
followed by the address of the sector/block to be erased, and the sector/block erase command. The
Command Definitions table shows the address and data requirements for the sector/block erase
command sequence.
Once the sector/block erase operation has begun, only the Erase Suspend command is valid. All other
commands are ignored.
When the Embedded Erase algorithm is complete, the device returns to reading array data and
addresses are no longer latched. The system can determine the status of the erase operation by using
DQ7, DQ6, or DQ2. Refer to “Write Operation Status” for information on these status bits. Flowchart 4
illustrates the algorithm for the erase operation. Refer to the Erase/Program Operations tables in the “AC
Characteristics” section for parameters, and to the Sector/Block Erase Operations Timing diagram for
timing waveforms.
Erase Suspend / Resume Command
The Erase Suspend command allows the system to interrupt a sector/block erase operation and then
read data from, or program data to, any sector/block not selected for erasure. This command is valid only
during the sector/block erase operation. The Erase Suspend command is ignored if written during the chip
erase operation or Embedded Program algorithm. Addresses are don’t-cares when writing the Erase
Suspend command.
When the Erase Suspend command is written during a sector/block erase operation, the device requires
a maximum of 20 µs to suspend the erase operation.
After the erase operation has been suspended, the system can read array data from or program data to
any sector/block not selected for erasure. (The device “erase suspends” all sector/blocks selected for
erasure.) Normal read and write timings and command definitions apply. Reading at any address within
erase-suspended sectors/blocks produces status data on DQ7–DQ0. The system can use DQ7, or DQ6
and DQ2 together, to determine if a sector/block is actively erasing or is erase-suspended. See “Write
Operation Status” for information on these status bits.
After an erase-suspended program operation is complete, the system can once again read array data
within non-suspended sectors/blocks. The system can determine the status of the program operation
using the DQ7 or DQ6 status bits, just as in the standard program operation. See “Write Operation
Status” for more information. The Autoselect command is not supported during Erase Suspend Mode.
The system must write the Erase Resume command (address bits are don’t-care) to exit the erase
suspend mode and continue the sector/block erase operation. Further writes of the Resume command
are ignored. Another Erase Suspend command can be written after the device has resumed erasing.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
16
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
WRITE OPERATION STATUS
DQ7: DATA# Polling
The EN39SL800 provides DATA# polling on DQ7 to indicate the status of the embedded operations. The
DATA# Polling feature is active during the embedded Programming, Sector/Block Erase, Chip Erase, and
Erase Suspend. (See Table 6)
When the embedded Programming is in progress, an attempt to read the device will produce the
complement of the data last written to DQ7. Upon the completion of the embedded Programming, an
attempt to read the device will produce the true data written to DQ7. For the embedded Programming,
DATA# polling is valid after the rising edge of the fourth WE# or CE# pulse in the four-cycle sequence.
When the embedded Erase is in progress, an attempt to read the device will produce a “0” at the DQ7
output. Upon the completion of the embedded Erase, the device will produce the “1” at the DQ7 output
during the read cycles. For Chip Erase, the DATA# polling is valid after the rising edge of the sixth WE# or
CE# pulse in the six-cycle sequence. DATA# polling is valid after the last rising edge of the WE# or CE#
pulse for chip erase or sector/block erase.
DATA# Polling must be performed at any address within a sector/block that is being programmed or
erased and not a protected sector/block. Otherwise, DATA# polling may give an inaccurate result if the
address used is in a protected block.
Just prior to the completion of the embedded operations, DQ7 may change asynchronously when the
output enable (OE#) is low. This means that the device is driving status information on DQ7 at one instant
of time and valid data at the next instant of time. Depending on when the system samples the DQ7 output,
it may read the status of valid data. Even if the device has completed the embedded operations and DQ7
has a valid data, the data output on DQ0-DQ6 may be still invalid. The valid data on DQ0-DQ7 will be
read on the subsequent read attempts.
The flowchart for DATA# Polling (DQ7) is shown on Flowchart 5. The DATA# Polling (DQ7) timing
diagram is shown in Figure 8.
DQ6: Toggle Bit I
The EN39SL800 provides a “Toggle Bit” on DQ6 to indicate to the host system the status of the
embedded programming and erase operations. (See Table 6)
During an embedded Program or Erase operation, successive attempts to read data from the device at
any address (by active OE# or CE#) will result in DQ6 toggling between “zero” and “one”. Once the
embedded Program or Erase operation is completed, DQ6 will stop toggling and valid data will be read on
the next successive attempts. During embedded Programming, the Toggle Bit is valid after the rising edge
of the fourth WE# pulse in the four-cycle sequence. During Erase operation, the Toggle Bit is valid after
the rising edge of the sixth WE# pulse for sector/block erase or chip erase.
In embedded Programming, if the block being written to is protected, DQ6 will toggles for about 2 μs, then
stop toggling without the data in the block having changed. In Sector/Block Erase or Chip Erase, if all
selected blocks are protected, DQ6 will toggle for about 100 μs. The chip will then return to the read mode
without changing data in all protected blocks.
The flowchart for the Toggle Bit (DQ6) is shown in Flowchart 6. The Toggle Bit timing diagram is shown in
Figure 9.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
17
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
DQ5: Exceeded Timing Limits
DQ5 indicates whether the program or erase time has exceeded a specified internal pulse count limit.
Under these conditions DQ5 produces a “1.” This is a failure condition that indicates the program or erase
cycle was not successfully completed. Since it is possible that DQ5 can become a 1 when the device has
successfully completed its operation and has returned to read mode, the user must check again to see if
the DQ6 is toggling after detecting a “1” on DQ5.
The DQ5 failure condition may appear if the system tries to program a “1” to a location that is previously
programmed to “0.” Only an erase operation can change a “0” back to a “1.” Under this condition, the
device halts the operation, and when the operation has exceeded the timing limits, DQ5 produces a “1.”
Under both these conditions, the system must issue the reset command to return the device to reading
array data.
DQ3: Sector/Block Erase Timer
After writing a sector/block erase command sequence, the output on DQ3 can be used to determine
whether or not an erase operation has begun. (The sector/block erase timer does not apply to the chip
erase command.) When sector/block erase starts, DQ3 switches from “0” to “1.” This device does not
support multiple sector/block erase command sequences so it is not very meaningful since it immediately
shows as a “1” after the first 30h command. Future devices may support this feature.
DQ2: Erase Toggle Bit II
The “Toggle Bit” on DQ2, when used with DQ6, indicates whether a particular sector/block is actively
erasing (that is, the Embedded Erase algorithm is in progress), or whether that sector/block is erasesuspended. Toggle Bit II is valid after the rising edge of the final WE# pulse in the command sequence.
DQ2 toggles when the system reads at addresses within those sectors/blocks that have been selected for
erasure. (The system may use either OE# or CE# to control the read cycles.) But DQ2 cannot distinguish
whether the sector/block is actively erasing or is erase-suspended. DQ6, by comparison, indicates
whether the device is actively erasing, or is in Erase Suspend, but cannot distinguish which
sectors/blocks are selected for erasure. Thus, both status bits are required for sector/block and mode
information. Refer to the following table to compare outputs for DQ2 and DQ6.
Flowchart 6 shows the toggle bit algorithm, and the section “DQ2: Toggle Bit” explains the algorithm. See
also the “DQ6: Toggle Bit I” subsection. Refer to the Toggle Bit Timings figure for the toggle bit timing
diagram. The DQ2 vs. DQ6 figure shows the differences between DQ2 and DQ6 in graphical form.
Reading Toggle Bits DQ6/DQ2
Refer to Flowchart 6 for the following discussion. Whenever the system initially begins reading toggle bit
status, it must read DQ7–DQ0 at least twice in a row to determine whether a toggle bit is toggling.
Typically, a system would note and store the value of the toggle bit after the first read. After the second
read, the system would compare the new value of the toggle bit with the first. If the toggle bit is not
toggling, the device has completed the program or erase operation. The system can read array data on
DQ7–DQ0 on the following read cycle.
However, if after the initial two read cycles, the system determines that the toggle bit is still toggling, the
system also should note whether the value of DQ5 is high (see the section on DQ5). If it is, the system
should then determine again whether the toggle bit is toggling, since the toggle bit may have stopped
toggling just as DQ5 went high. If the toggle bit is no longer toggling, the device has successfully
completed the program or erase operation. If it is still toggling, the device did not complete the operation
successfully, and the system must write the reset command to return to reading array data.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
18
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
The remaining scenario is that the system initially determines that the toggle bit is toggling and DQ5 has
not gone high. The system may continue to monitor the toggle bit and DQ5 through successive read
cycles, determining the status as described in the previous paragraph. Alternatively, it may choose to
perform other system tasks. In this case, the system must start at the beginning of the algorithm when it
returns to determine the status of the operation (top of Flowchart 6).
Write Operation Status
Standar
d Mode
Erase
Suspend
Mode
Operation
DQ7
(note2)
DQ6
DQ5
(note1)
DQ3
DQ2
(note2)
Embedded Program
Algorithm
DQ7#
Toggle
0
N/A
No
toggle
Embedded Erase Algorithm
0
Toggle
0
1
Toggle
1
No
Toggle
0
N/A
Toggle
Data
Data
Data
Data
Data
DQ7#
Toggle
0
N/A
N/A
Reading within Erase
Suspended Sector/Block
Reading within Non-Erase
Suspended Sector/Block
Erase-Suspend Program
1. DQ5 switches to ‘1’ when an Embedded Program or Embedded Erase operation has exceeded the maximum timing limits. See
“DQ5:Exceeded Timing Limits” for more information.
2. DQ7 and DQ2 require a valid address when reading status information. Refer to the appropriate subsection for further details.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
19
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
Table 9. Status Register Bits
DQ
Name
Logic Level
DQ7#
Definition
Erase Complete or
erase Sector/Block in Erase suspend
Erase On-Going
Program Complete or
data of non-erase Sector/Block during
Erase Suspend
Program On-Going
‘-1-0-1-0-1-0-1-’
Erase or Program On-going
DQ6
Read during Erase Suspend
‘-1-1-1-1-1-1-1-‘
Erase Complete
‘1’
‘0’
‘1’
‘0’
Program or Erase Error
Program or Erase On-going
Erase operation start
Erase timeout period on-going
Chip Erase, Sector/Block Erase or
Erase suspend on currently addressed
Sector/Block. (When DQ5=1, Erase
Error due to currently addressed
Sector/Block. Program during Erase
Suspend on-going at current address
‘1’
7
6
DATA#
POLLING
TOGGLE
BIT
5
TIME OUT BIT
3
ERASE TIME
OUT BIT
2
TOGGLE
BIT
‘0’
DQ7
‘-1-0-1-0-1-0-1-’
Erase Suspend read on
non Erase Suspend Sector/Block
DQ2
Notes:
DQ7 DATA# Polling: indicates the P/E C status check during Program or Erase, and on completion before checking bits DQ5 for
Program or Erase Success.
DQ6 Toggle Bit: remains at constant level when P/E operations are complete or erase suspend is acknowledged. Successive reads
output complementary data on DQ6 while programming or Erase operation are on-going.
DQ5 Time Out Bit: set to “1” if failure in programming or erase
DQ3 Sector/Block Erase Command Timeout Bit: Operation has started. Only possible command is Erase suspend (ES).
DQ2 Toggle Bit: indicates the Erase status and allows identification of the erased Sector/Block
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
20
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
EMBEDDED ALGORITHMS
Flowchart 1. Embedded Program
START
Write Program
Command Sequence
(shown below)
Data# Poll Device
Verify Data?
Increment
Address
Last
No
Address?
Yes
Programming Done
Flowchart 2. Embedded Program Command Sequence
See the Command Definitions section for more information on WORD mode.
555H / AAH
2AAH / 55H
555H / A0H
PROGRAM ADDRESS / PROGRAM DATA
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
21
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
Flowchart 3. Embedded Erase
START
Write Erase
Command Sequence
Data Poll from
System or Toggle Bit
successfully
completed
Data =FFh?
No
Yes
Erase Done
Flowchart 4. Embedded Erase Command Sequence
See the Command Definitions section for more information on WORD mode.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
22
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
Flowchart 5. DATA# Polling
Algorithm
Start
Read Data
DQ7 = Data?
Yes
No
No
DQ5 = 1?
Yes
Read Data (1)
Notes:
(1) This second read is necessary in case the
first read was done at the exact instant when
the status data was in transition.
DQ7 = Data?
Yes
No
Fail
Pass
Start
Flowchart 6. Toggle Bit Algorithm
Read Data twice
DQ6 = Toggle?
No
Yes
No
DQ5 = 1?
Yes
Read Data twice (2)
DQ6 = Toggle?
Notes:
(2) This second set of reads is necessary in case
the first set of reads was done at the exact
instant when the status data was in transition.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
No
Yes
Fail
23
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
Pass
www.eonssi.com
EN39SL800
Flowchart 7a. In-System Block Protect Flowchart
START
Setup Block Address
(A18-A15)
PLSCNT=1
Increment
PLSCNT
OE#= VID, A9= VID,
CE#= VIL, Vcc=3.3V
A6=0, A1=1, A0=0
Activate WE#
Time Out 100 μs
A9= VID,
CE#=OE#= VIL,
WE#= VIH
Read from Block
Address A18-A15
while A6=VIL, A1=VIH,
A0=VIL
No
PLSCNT=25 ?
Data = 01h ?
No
Yes
Yes
Protect another
Block?
Yes
No
Remove VID from A9
Write Reset
Command
Device failed
Block Group
Protection Complete
Block Protect Algorithm
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
24
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
Flowchart 7b. In-System Chip Unprotect Flowchart
START
Protect All Blocks
PLSCNT=1, Set Block
Address to SA0
Setup Chip
Unprotect Mode ,
A6=1, A1=1, A0=0
Set OE#=VID, A9=VID
Activate WE# Pulse
Increment PLSCNT
Time Out 10 ms
Set OE#= VIL,
WE#= VIH , A9=VID
Set A6=1, A1=1, A0=0,
CE# = VIL
Read Data from
Device
Increment Block
Group Address
No
No
Last Block
Address?
Yes
Data = 00h ?
No
PLSCNT=1000?
Yes
Yes
Remove VID from A9
Device
Failed
Chip Unprotection
Completed
Chip Unprotect Algorithm
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
25
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
Table 10. DC Characteristics
(Ta = - 40°C to 85°C; VCC = 1.65-1.95V)
Symbol
Parameter
Test Conditions
ILI
Input Leakage Current
ILO
Min
Max
Unit
0V≤ VIN ≤ Vcc
±3
µA
Output Leakage Current
0V≤ VOUT ≤ Vcc
±3
µA
ICC1
Active Read Current
5
10
mA
ICC2
Supply Current (Standby)
CE# = VIL, OE# = VIH,
F=5MHz
CE# = Vcc,
Vcc = Vcc max
0.2
5.0
µA
ICC3
Supply Current (Program or Erase)
15
25
mA
ICC4
Automatic Sleep Mode
0.2
5.0
µA
VIL
Input Low Voltage
-0.5
VIH
Input High Voltage
0.7 x
Vcc
VOL
Output Low Voltage
IOL = 100 μA
VOH
Output High Voltage
IOH = -100 μA,
VID
A9 Voltage (Electronic Signature)
IID
A9 Current (Electronic Signature)
VLKO
Supply voltage (Erase and
Program lock-out)
Program or Erase in
progress
VIH = Vcc ± 0.2 V
VIL = Vss ± 0.2 V
Typ
0.3 x
VCC
Vcc +
0.3
0.1
Vcc 0.1
9.0
V
V
V
V
10.0
A9 = VID
1.2
11.0
V
50
µA
1.5
V
Notes
1. Maximum ICC specifications are tested with Vcc = Vcc max.
B
B
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
26
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
Test Conditions
Test Specifications
Test Conditions
-70
Unit
Output Load Capacitance, CL
30
pF
Input Rise and Fall times
5
ns
Input Pulse Levels
Input timing measurement
reference levels
Output timing measurement
reference levels
0.0-2.0
V
1/2 Vcc
V
1/2 Vcc
V
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
27
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
AC CHARACTERISTICS
Table 11. AC CHARACTERISTICS
(Ta = - 40°C to 85°C; VCC = 1.65-1.95 V)
Read-only Operations Characteristics
Parameter
Symbols
Test Setup
Description
JEDEC
Standard
tAVAV
tRC
Read Cycle Time
tAVQV
tACC
Address to Output Delay
tELQV
tCE
Chip Enable To Output Delay
tGLQV
tOE
tEHQZ
Speed Options
Unit
-70
Min
70
ns
CE# = VIL
OE# = VIL
Max
70
ns
OE# = VIL
Max
70
ns
Output Enable to Output Delay
Max
30
ns
tDF
Chip Enable to Output High Z
Max
20
ns
tGHQZ
tDF
Output Enable to Output High Z
Max
20
ns
tAXQX
tOH
Output Hold Time from
Addresses, CE# or OE#,
whichever occurs first
Min
0
ns
tOEH
Output Enable
Hold Time
Read
Min
0
ns
Toggle and
Data# Polling
Min
10
ns
Notes:
1. High Z is Not 100% tested.
2. For – 70
Vcc =1.65 – 1.95V
Output Load : 30pF
Input Rise and Fall Times: 5ns
Input Rise Levels: 0.0 V to Vcc
Timing Measurement Reference Level, Input and Output: 1/2 Vcc
Figure 2. AC Waveforms for READ Operations
tBRCB
Addresses
Addresses Stable
tBACC
CE#
OE#
WE#
tBDF
tBOEB
tBOEHB
tBCEB
Outputs
tBOH
HIGH Z
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
Output Valid
28
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
HIGH Z
www.eonssi.com
EN39SL800
Table 12. AC CHARACTERISTICS
(Ta = - 40°C to 85°C; VCC = 1.65-1.95V)
Write (Erase/Program) Operations
Parameter
Symbols
Speed Options
Description
JEDEC
Standard
-70
Unit
tAVAV
tWC
Write Cycle Time (Note 1)
Min
70
ns
tAVWL
tAS
Address Setup Time
Min
0
ns
tWLAX
tAH
Address Hold Time
Min
45
ns
tDVWH
tDS
Data Setup Time
Min
30
ns
tWHDX
tDH
Data Hold Time
Min
0
ns
tOES
Output Enable Setup Time
Min
0
ns
Read Recovery Time before Write
(OE# High to WE# Low)
Min
0
ns
tGHWL
tGHWL
tELWL
tCS
CE# Setup Time
Min
0
ns
tWHEH
tCH
CE# Hold Time
Min
0
ns
tWLWH
tWP
Write Pulse Width
Min
35
ns
tWHDL
tWPH
Write Pulse Width High
Min
20
ns
tWHWH1
tWHWH1
Word Programming Operation (Note 2)
Typ
8
µs
Sector
Typ
0.09
s
Block
Typ
0.18
s
Chip
Typ
2
s
Vcc Setup Time (Note 1)
Min
50
µs
Voltage Transition Time
Min
500
ns
Block Pulse Width
Min
100
μs
Chip Unprotection Pulse Width
Min
10
ms
Min
Voltage setup time
Notes:
1. Not 100% tested.
2. See Erase and Programming Performance for more information.
4
μs
tWHWH2
tWHWH2
tVCS
tVT
tWPP1
tWPP2
tST
Erase Operation (Note 2)
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
29
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
Table 13. AC CHARACTERISTICS
(Ta = - 40°C to 85°C; VCC = 1.65-1.95V)
Write (Erase/Program) Operations
Alternate CE# Controlled Writes
Parameter
Symbols
JEDEC
Speed Options
Description
Standard
-70
Unit
tAVAV
tWC
Write Cycle Time (Note 1)
Min
70
ns
tAVEL
tAS
Address Setup Time
Min
0
ns
tELAX
tAH
Address Hold Time
Min
45
ns
tDVEH
tDS
Data Setup Time
Min
30
ns
tEHDX
tDH
Data Hold Time
Min
0
ns
tOES
Output Enable Setup Time
Min
0
ns
tGHEL
tGHEL
Read Recovery Time before Write
(OE# High to CE# Low)
Min
0
ns
tWLEL
tWS
WE# Setup Time
Min
0
ns
tEHWH
tWH
WE# Hold Time
Min
0
ns
tELEH
tCP
CE# Pulse Width
Min
35
ns
tEHEL
tCPH
CE# Pulse Width High
Min
20
ns
tWHWH1
tWHWH1
Word Programming Operation (Note 2)
Typ
8
µs
Sector
Typ
0.09
s
Block
Typ
0.18
s
Chip
Typ.
2
s
tWHWH2
tWHWH2
Erase Operation
(Note 2)
Notes:
1. Not 100% tested.
2. See Erase and Programming Performance for more information.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
30
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
Table 14. ERASE AND PROGRAMMING PERFORMANCE
Typ
Limits
Max
Unit
Sector Erase Time
0.09
0.4
sec
Block Erase Time
0.18
2
sec
Chip Erase Time
2
20
sec
Word Programming Time
8
200
µs
Chip Programming Time
4
5.5
sec
Erase/Program Endurance
100K
Parameter
cycles
Comments
Excludes 00H programming prior
to erasure
Excludes system level overhead
Minimum 100K cycles
Table 15. DATA RETENTION
Parameter Description
Test Conditions
Min
Unit
150°C
10
Years
125°C
20
Years
Data Retention Time
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
31
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
AC CHARACTERISTICS
Figure 3. AC Waveforms for Chip Erase Operations Timings
Erase Command Sequence (last 2 cycles)
tAS
tWC
Addresses
0x2AA
Read Status Data (last two cycles)
tAH
0x555
VA
VA
CE#
tGHWL
tCH
OE#
tWP
WE#
tWPH
tCS
0x55
Data
tDS
VCC
tWHWH2
0x10
Status
DOUT
tDH
tVCS
Notes:
1. VA=Valid Address for reading status, Dout=true data at read address.
2. Vcc shown only to illustrate tvcs measurement references. It cannot occur as shown during a valid command
sequence.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
32
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
AC CHARACTERISTICS
Figure 4. AC Waveforms for Block Erase Operations Timings
Erase Command Sequence (last 2 cycles)
tAS
tWC
Addresses
0x2AA
Read Status Data (last two cycles)
tAH
BA
VA
VA
CE#
tGHWL
tCH
OE#
tWP
WE#
tWPH
tCS
0x55
Data
tDS
VCC
tWHWH2
0x50
Status
DOUT
tDH
tVCS
Notes:
1. BA=Block Address (for block erase), VA=Valid Address for reading status, Dout=true data at read address.
2. Vcc shown only to illustrate tvcs measurement references. It cannot occur as shown during a valid command
sequence.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
33
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
Figure 5. AC Waveforms for Sector Erase Operations Timings
Erase Command Sequence (last 2 cycles)
tAS
tWC
Addresses
0x2AA
Read Status Data (last two cycles)
tAH
SA
VA
VA
CE#
tGHWL
tCH
OE#
tWP
WE#
tWPH
tCS
0x55
Data
tDS
tWHWH2
0x30
Status
DOUT
tDH
VCC
tVCS
Notes:
1. SA=Sector Address (for sector erase), VA=Valid Address for reading status, Dout=true data at read address.
2. Vcc shown only to illustrate tvcs measurement references. It cannot occur as shown during a valid command
sequence.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
34
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
Figure 6. Program Operation Timings
Program Command Sequence (last 2 cycles)
tAS
tWC
Addresses
0x555
Program Command Sequence (last 2 cycles)
tAH
PA
PA
PA
CE#
tGHWL
OE#
tCH
tWP
WE#
tWPH
tCS
Data
OxA0
tDS
VCC
tWHWH1
Status
PD
DOUT
tDH
tVCS
Notes:
1. PA=Program Address, PD=Program Data, DOUT is the true data at the program address.
2. VCC shown in order to illustrate tVCS measurement references. It cannot occur as shown during a valid command
sequence.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
35
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
Figure 7. AC Waveforms for /DATA Polling During Embedded Algorithm Operations
tRC
Addresses
VA
tCH
VA
VA
tACC
tCE
CE#
tOE
OE#
tOEH
tDF
WE#
tOH
DQ[7]
Complement
DQ[6:0]
Status Data
Comple
-ment
Status
Data
Valid Data
True
True
Valid Data
Notes:
1. VA=Valid Address for reading Data# Polling status data
2. This diagram shows the first status cycle after the command sequence, the last status read cycle and the array data read cycle.
Figure 8. AC Waveforms for Toggle Bit During Embedded Algorithm Operations
tRC
Addresses
VA
VA
tCH
VA
VA
tACC
tCE
CE#
tOE
OE#
WE#
DQ6, DQ2
tOEH
tDF
tOH
Valid Status
(first read)
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
Valid Status
(second read)
36
Valid Status
(stops toggling)
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
Valid Data
www.eonssi.com
EN39SL800
Figure 9. Alternate CE# Controlled Write Operation Timings
PA for Program
SA for Sector Erase
BA for Block Erase
0x555 for Chip Erase
0x555 for Program
0x2AA for Erase
Addresses
VA
tWC
tAS
tAH
WE#
tWH
tGHEL
OE#
tCP
tCPH
tWS
CE#
tDS
tWHWH1 / tWHWH2
tDH
Status
Data
DOUT
PD for Program
0x30 for Sector Erase
0x50 for Block Erase
0x10 for Chip Erase
0xA0 for
Program
Notes:
PA = address of the memory location to be programmed.
PD = data to be programmed at byte address.
VA = Valid Address for reading program or erase status
Dout = array data read at VA
Figure 10. DQ2 vs. DQ6
Enter
Embedded
Erase
WE#
Enter Erase
Suspend
Program
Erase
Suspend
Erase
Erase
Resume
Enter
Suspend
Program
Enter
Suspend
Read
Erase
Suspend
Read
Erase
Erase
Complete
DQ6
DQ2
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
37
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
Figure 11. Block Protect Timing Diagram
A18-A12
SAx
A0
A1
A6
12V
A9
tVT
tVT
12V
OE#
tVT
tWPP
WE#
tST
CE#
01h
DATA
tST
tOE
SAx = Block Address for initial block
SAy = Block Address for next block
Notes:
Use standard microprocessor timings for this device for read and write cycles.
For Block Protect, use A6=0, A1=1, A0=0.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
38
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
Figure 12. Chip Unprotect Timing Diagram
VIH
A17, A18, A19 VIL
SAx
SAy
VIH
A0
VIL
VIH
A1
VIL
VIH
A6
VIL
VID
A9
VIL
VID
OE#
VIL
VIH
WE#
CE#
tVT
tVT
tST
VIL
VIH
tWPP2
VIL
00 h
Data
tST
tOE
Notes:
Use standard microprocessor timings for this device for read and write cycles.
For Chip Unprotect, use A6=1, A1=1, A0=0.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
39
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
Figure 13. 48L TFBGA 6mm x 8mm package outline
SYMBOL
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
40
DIMENSION IN MM
MIN.
NOR
MAX
A
---
---
1.30
A1
0.23
0.29
---
A2
0.84
0.91
---
D
7.90
8.00
8.10
E
5.90
6.00
6.10
D1
---
5.60
---
E1
---
4.00
---
e
---
0.80
---
b
0.35
0.40
Note : 1. Coplanarity: 0.1 mm
0.45
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
Figure 14. 48L WFBGA 4mm x 6mm package outline
Note : Controlling dimensions are in millimeters (mm).
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
41
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
ABSOLUTE MAXIMUM RATINGS
Parameter
Value
Unit
Storage Temperature
-65 to +150
℃
Plastic Packages
-65 to +125
℃
Ambient Temperature
With Power Applied
-55 to +125
℃
Output Short Circuit Current1
200
mA
A9, OE# 2
-0.5 to +11.0
V
All other pins 3
-0.5 to Vcc+0.5
V
Vcc
-0.5 to Vcc+0.5
V
Voltage with
Respect to Ground
Notes:
1.
No more than one output shorted may be shorted to ground at a time. Duration of the short circuit should not be greater than one
second.
2.
Minimum DC input voltage on A9 and OE# pins is –0.5V. During voltage transitions, A9 and OE# pins may undershoot Vss to –1.0V
for periods of up to 50ns and to –2.0V for periods of up to 20ns. See figure below. Maximum DC input voltage on A9 and OE# is
9.0V which may overshoot to 11.0V for periods up to 20ns.
3.
Minimum DC voltage on input or I/O pins is –0.5 V. During voltage transitions, inputs may undershoot Vss to –1.0V for periods of up
to 50ns and to –2.0 V for periods of up to 20ns. See figure below. Maximum DC voltage on output and I/O pins is Vcc + 0.5 V.
During voltage transitions, outputs may overshoot to Vcc + 1.5 V for periods up to 20ns. See figure below.
4.
Stresses above the values so mentioned above may cause permanent damage to the device. These values are for a stress rating
only and do not imply that the device should be operated at conditions up to or above these values. Exposure of the device to the
maximum rating values for extended periods of time may adversely affect the device reliability.
RECOMMENDED OPERATING RANGES1
Parameter
Value
Unit
-40 to 85
℃
Full Voltage Range:
1.65 to 1.95
V
Ambient Operating Temperature
Industrial Devices
Operating Supply Voltage
Vcc
1. Recommended Operating Ranges define those limits between which the functionality of the device is guaranteed.
Vcc
+2.0V
0
0
Maximum Negative Overshoot Waveform
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
Maximum Positive Overshoot Waveform
42
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
Purpose
Eon Silicon Solution Inc. (hereinafter called “Eon”) is going to provide its products’ top marking on
ICs with < cFeon > from January 1st, 2009, and without any change of the part number and the
compositions of the ICs. Eon is still keeping the promise of quality for all the products with the same
as that of Eon delivered before. Please be advised with the change and appreciate your kindly
cooperation and fully support Eon’s product family.
Eon products’ New Top Marking
cFeon Top Marking Example:
cFeon
Part Number: XXXX-XXX
Lot Number: XXXXX
Date Code: XXXXX
For More Information
Please contact your local sales office for additional information about Eon memory solutions.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
43
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
ORDERING INFORMATION
EN39SL800
-
70
B
I
P
PACKAGING CONTENT
P = RoHS compliant
TEMPERATURE RANGE
I = Industrial (-40°C to +85°C)
PACKAGE
B = 48-Ball Thin Fine Pitch Ball Grid Array (TFBGA)
0.8mm pitch, 6mm x 8mm package
N = 48-Ball Very-Very-Thin-Profile Fine Pitch
Ball Grid Array (WFBGA)
0.5mm pitch, 4mm x 6mm package
SPEED
70 = 70ns
BASE PART NUMBER
EN = Eon Silicon Solution Inc.
39SL = 1.8V Serial 4KByte Uniform-Sector FLASH
800 = 8 Megabit (512K x 16)
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
44
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
www.eonssi.com
EN39SL800
Revisions List
Revision No Description
Date
A
2009/02/20
B
C
D
E
F
G
Initial Release
1. Modify Table 5 addresses 13h = 0002h, 14h = 0000h and 15h = 0040h on
page 12.
2. Update Table 12, 13 on page 31 and 32.
1. Correct typo 15Æ5 mA typical active read current in page 1.
2. Correct typo tBUSY MinÆMax in Page 31.
To modify Table 10, Icc1 active read current (max.) from 6mA to 10mA on page
26
1. Modify TFBGA ball diagram (BYTE#, RESET# and RY/BY# pins are changed
to NC status)
2. Removal of WLGA 5mm x 6mm package definition
3. addition of TSOP (type 1) package information
1. Removal of all of 90ns descriptions
2. modify the max sector erase time to 0.4s
3. adding byte / word programming maximum time
1. Remove the BYTE#, RESET# and RY/BY# functions and TSOP (type 1)
package information.
2. Modify the description of Block Protection and Chip Unprotection on page 10,
24, 25, 38 and 39.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
45
©2004 Eon Silicon Solution, Inc.,
Rev. G, Issue Date: 2009/08/18
2009/03/03
2009/03/24
2009/05/13
2009/06/08
2009/06/15
2009/08/18
www.eonssi.com
Similar pages