Series AM1N-NZ 1 Watt | DC-DC Converter FEATURES: • • • • • • • • RoHS compliant 24 Pin DIP Package Low profile plastic package High efficiency up to 75% o o Operating temperature -40 C to + 85 C Input / Output Isolation 6000VDC Pin compatible with multiple manufacturers UL94-VO Package Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VDC) Efficiency (%) 4.5-5.5 4.5-5.5 4.5-5.5 4.5-5.5 10.8-13.2 10.8-13.2 10.8-13.2 10.8-13.2 5 9 12 15 5 9 12 15 200 111 84 67 200 111 84 67 6000 6000 6000 6000 6000 6000 6000 6000 68 72 74 74 69 72 74 75 Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VDC) Efficiency (%) ±100 ±55 ±42 ±33 ±100 ±55 ±42 ±33 6000 6000 6000 6000 6000 6000 6000 6000 68 72 74 74 69 72 74 75 AM1N-0505SH60-NZ AM1N-0509SH60-NZ AM1N-0512SH60-NZ AM1N-0515SH60-NZ AM1N-1205SH60-NZ AM1N-1209SH60-NZ AM1N-1212SH60-NZ AM1N-1215SH60-NZ Models Dual output Model AM1N-0505DH60-NZ AM1N-0509DH60-NZ AM1N-0512DH60-NZ AM1N-0515DH60-NZ AM1N-1205DH60-NZ AM1N-1209DH60-NZ AM1N-1212DH60-NZ AM1N-1215DH60-NZ 4.5-5.5 4.5-5.5 4.5-5.5 4.5-5.5 10.8-13.2 10.8-13.2 10.8-13.2 10.8-13.2 ±5 ±9 ±12 ±15 ±5 ±9 ±12 ±15 NOTE: All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Voltage range Nominal 5 12 Typical 4.5-5.5 10.8-13.2 Filter Maximum Units VDC Rated 6000 Units VDC MOhm pF Capacitor Isolation Specifications Parameters Tested I/O voltage Resistance Capacitance Conditions 60 sec Typical > 1000 60 Output Specifications Parameters Voltage accuracy Short Circuit protection Line voltage regulation (Single) Line voltage regulation (Dual) Load voltage regulation (Single) Load voltage regulation (Dual) www.aimtec.com F 051e R6.C Conditions Typical Maximum Units See tolerance envelope graph Momentary (1sec) ±1.2 ±1.2 10 10 For 1.0% of Vin For 1.0% of Vin Load 10 – 100% Load 10 – 100% Tel: +1 514 620 2722 1 of 3 % % % % Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM1N-NZ 1 Watt | DC-DC Converter Output Specifications (continued) Parameters Temperature coefficient Ripple & Noise Conditions Typical At 20MHz Bandwidth ±0.03 75 Maximum Units o %/ C mV p-p General Specifications Parameters Switching frequency Operating temperature Storage temperature Max Case temperature Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Conditions Typical 100% load Without derating 250 Maximum Units 95 KHz o C o C o C 90 % -40 to +85 -55 to +125 Free air convection Plastic UL94-VO g 16 1.27 x 0.58 x 0.37 inches 32.30 x 14.70 x 9.40mm o >1 211 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25 C) NOTE: All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Safety Specifications Parameters Agency approvals Standards cULus UL60950-1 Pin Out Specifications External capacitor – Single output Pin Single Dual 1 2 8,17 10,15 12,13 + V Input - V Input N.C. -V Output +V Output + V Input - V Input -V Output Common +V Output Vin (VDC) External capacitor (µF) Vout (VDC) 5 12 24 - 4.7 2.2 1 5 9 12 15 External capacitor (µF) 10 4.7 2.2 1 External capacitor – Dual output Vin (VDC) External capacitor (µF) 5 12 24 - 4.7 2.2 1 - Vout (VDC) 5 9 12 15 External capacitor (µF) 4.7 2.2 1 0.47 Dimensions 32.30 (1.27) Top View 14.70 (0.58) Footprint 2.54 (0.10) 2.54 (0.01) 1.00 0 + 0.15/-0 Side View 9.40 (0.37) 0.65 (0.03) 4.00 (0.16) 2.54 (0.10) www.aimtec.com F 051e R6.C Tel: +1 514 620 2722 2 of 3 27.94 (1.10) Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM1N-NZ 1 Watt | DC-DC Converter Block diagram single output Block diagram dual output Tolerance Envelope Graph +10% Typic a +5% line +2.5% -2.5% Output Voltage (%) Nominal Voltage l load -7.5% 10% 50% 100% Output Current (%) NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R6.C Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only