Surge Arrester
2-Electrode-Arrester
A81-C90XSMD
Ordering code: B88069X1370T352
DC spark-over voltage 1) 2)
90
± 20
V
%
< 500
< 450
V
V
< 600
< 550
V
V
Nominal impulse discharge current (wave 8/20 µs)
Single impulse discharge current
(wave 8/20 µs)
Single impulse discharge current
(wave 10/350 µs)
20
25
5
kA
kA
kA
Nominal alternating discharge current (50 Hz, 1 s)
Alternating discharge current (50 Hz, 9 cycles)
20
100
A
A
Insulation resistance at 50 Vdc
> 10
GΩ
Capacitance at 1 MHz
< 1.5
pF
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
~ 15
~ 0.6
~ 60
V
A
V
Weight
~ 1.5
g
Operation and storage temperature
-40 ... +90
°C
Climatic category (IEC 60068-1)
40/ 90/ 21
Impulse spark-over voltage
at 100 V/µs - for 99 % of measured values
- typical values of distribution
at 1 kV/µs
- for 99 % of measured values
- typical values of distribution
Marking, blue
90 YY O
90
YY
O
- Nominal voltage
- Year of production
- Non radioactive
1)
At delivery AQL 0.65 level II, DIN ISO 2859
In ionized mode
Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845
2)
AB E / AB PM
Issue 06, 06.02.2003
Page 1 of 2
Surge Arrester
2-Electrode-Arrester
A81-C90XSMD
Ordering code: B88069X1370T352
Not to scale
Dimensions in mm
Non controlled document
SMD-Gurtverpackung nach IEC 60286-3 /
Tape and reel packing comply with the specification of IEC 60286-3
 EPCOS AG 2002. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited.
Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and
Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers' Association), unless
otherwise agreed.
AB E / AB PM
Issue 06, 06.02.2003
Page 2 of 2
Similar pages