EX-209 Hi-Reliability Evacuated Miniature Crystal Oscillator EX-209 Features • • • • • Applications 16 pin Double Dip Package Ruggedized hybrid thick film construction Low Power Consumption Frequency Range: 10 MHZ to 40 MHZ Previous Model: EX-245 • Severe Environmental Conditions Performance Specifications Parameter Min Typ Max Units Condition Frequency Stabilities1 [10 to 20 MHz] vs. operating temperature range (referenced to +25°C) -50 -75 -100 +50 +75 +100 ppb ppb ppb 0… +60°C -20… +70°C -40… +85°C Initial tolerance for fixed frequency Settability vs. supply voltage change vs. load change -1.0 -0.2 -15 -15 +1.0 +0.2 +15 +15 ppm ppm ppb ppb fixed, no adjust vs. aging / day vs. aging / 1 year vs. aging / 10 year (10 to <12 MHz) vs. aging / 10 year (12 to <16 MHz) vs. aging / 10 year (16 to 20 MHz) -2 -200 -1000 -1500 -2000 +2 +200 +1000 +1500 +2000 ppb ppb ppb ppb ppb after 7 days of operation 120 180 seconds seconds to ± 1ppm of final freq. @+25°C to ± 100ppb of final freq. @+25°C Warm-up Time2 VS ± 5% Load ± 5% Frequency Stabilities1 [>20 to 40 MHz] vs. operating temperature range (referenced to +25°C) -75 -100 -150 +75 +100 -150 ppb ppb ppb 0… +60°C -20… +70°C -40… +85°C Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com Performance Specifications Parameter Initial tolerance for fixed frequency Settability vs. supply voltage change vs. load change vs. aging / day vs. aging / 1 year vs. aging / 10 year Min Typ Max Units Condition -1.5 -0.3 -25 -25 +1.5 +0.3 +25 +25 ppm ppm ppb ppb fixed, no adjust -3 -300 -3000 +3 +300 +3000 ppb ppb ppb after 7 days of operation 120 180 seconds seconds to ± 1ppm of final freq. @+25°C to ± 100ppb of final freq. @+25°C Warm-up Time2 VS ± 5% Load ± 5% Supply Voltage (Vs) Supply voltage (Standard) 4.75 5.0 Power Consumption 5.25 VDC 2.2 0.7 1.2 Watts Watts Watts during warm-up steady state @ +25°C steady state @ -40°C RF Output HCMOS Signal [Standard] 15 Load pF 0.1 Signal Level (Vol) Vdd 0.9 Signal Level (Voh) Vdd Rise/Fall Time 40 Duty cycle +7 ns (10-90%) 60 % (Voh-Vol)/2 Sinewave Signal [Option] 50 Load ohm Output Power (Standard) 0.0 +2.0 +4.0 dBm 50 ohm load Output Power (Option) +3.0 +5.0 +7.0 dBm 50 ohm load Harmonics -25 dBc Spurious -60 dBc Frequency Tuning (EFC) Tuning Range Fixed OCXO; No adjust Tuning Range Sufficient to compensate for 10 years aging Vref +4.0 +4.1 +4.2 VDC EFC (0V to 4V) source current 1 mA maximum Additional Parameters [10 to 20 MHz] 1 Phase Noise (10 to 20 MHZ) -100 -125 -140 -145 -145 dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz 10 Hz 100 Hz 1 kHz 10 kHz 10 kHz Phase Noise3 (>20 to 40 MHZ) -90 -115 -130 -140 -140 dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz 10 Hz 100 Hz 1 kHz 10 kHz 10 kHz 1 ppb/g Test at 10g sine vibration at 100Hz 3 G-Sensitivity Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com Performance Specifications Parameter Min Typ Max Units Condition Environmental Conditions (Designed to meet) • Radiation Tolerant (operating): Active devices are selected from a family of product that is inherently radiation tolerant to meet 100krad (SI) total dose • Mechanical Shock (survive)***: MIL-STD-202, Test Method 213, Condition E (1000G, 0.5msec) • Vibration Random (survive)***: MIL-STD-202, Test Method 214, Condition I-F (20Grms, 3 minutes/axis) • Vibration Sine (survive)***: MIL-STD-202, Test Method 204, Condition D (20Grms, 20 minutes/axis) Note: *** Met by design, not tested Screening Options Ordering Code S B Test Inspection S-Level Screening B-Level Screening Nondestructive Bond Pull MIL-STD-883 Method 2023 N/A Internal Visual Per Mil-PRF55310 Requirement Internal Visual Per Mil-PRF-55310 Requirement Internal Visual Per Mil-PRF-55310 Requirement Stabilization Bake MIL-STD-883 Method 1008, Condition C 150°C for 48hrs MIL-STD-883 Method 1008, Condition C Thermal Shock MIL-STD-883 Method 1011, Condition A 0°C to 100°C for 15cycles N/A Temperature Cycling (1) MIL-STD-883 Method 1010, Condition A -55°C to 85°C (2) for 10cycles MIL-STD-883 Method 1010, Condition A -55°C to 85°C (2) for 10cycles Constant Acceleration (1) MIL-STD-883 Method 2001 1000g’s (3) Y1 Only MIL-STD-883 Method 2001 1000g’s (3) Y1 Only PIND MIL-STD-883 Method 2020, Condition B 10g peak at 60Hz minimum N/A Electrical Test Per Mil-PRF-55310 Requirement Per Mil-PRF-55310 Requirement Burn-in (1) 85°C (2) for 240hrs 85°C (2) for 240hrs Radiographic MIL-STD-883 Method 2012 N/A 150°C for 48hrs Note: (1) These test inspections deviate from screening requirements for class 2 oscillator in MIL-PRF-55310. (2) The maximum operating and storage temperature of the EX-209 is +85°C. The EX-209 shall not be exposed to temperature higher than +85°C at length of time. (3) The design and construction of the EX-209 can withstand up to 1000g’s constant acceleration Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com Outline Drawing / Enclosure Dimensions in inches (mm) Type A Code Height “H” Pin Length “L” 0 0.35 (8.9 mm) 0.17 Pin Connections 1 EFC \ No Connect 2-4 No Connect 8 Ground (Case) 9 Output 13-14 No Connect 15 Vref \ No Connect 16 Supply Voltage Input Recommended Reflow Profile TEMPERATURE (oC) 220 183 150 60s 60-90s 45-60s TIME (s) Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com Ordering Information EX - 209 0 - D A J - 002S - 10M0000000 Frequency Product Family EX: EMXO Platform Code Tuning Option (1st digit): 0: Fixed Frequecy 1: Electrical Tuning Package 25 x 25 mm Height 0: A0.35” Output Power (2nd digit) 0: 0 dBm 1: +3 dBm Supply Voltage D: 5 Vdc Stability Code (3rd digit) 0: ±50ppb 1: ±75ppb 2: ±100ppb 3: ±150ppb RF Output Code A: HCMOS E: Sinewave Screening Option (4th digit) S: “S” Level screening, Swept Quartz C: “B” Level screening, Swept Quartz B: “B” Level screening, Un-Swept Quartz E: “EM” Engineering Model , Un-Swept Quartz P: Proof of Design “POD-Prototype” , Un-Swept Quartz Temperature Range E: -40°C to +85°C J: -20°C to +70°C S: 0°C to +60°C Notes: 1. Contact factory for improved stabilities or additional product options. Not all options and codes are available at all frequencies. 2. Unless other stated all values are valid after warm-up time and refer to typical conditions for supply voltage, frequency control voltage, load, temperature (25°C). 3. Phase noise degrades with increasing output frequency. 4. Subject to technical modification. 5. Contact factory for availability. For Additional Information, Please Contact USA: Vectron International 267 Lowell Road Hudson, NH 03051 Tel: 1.888.328.7661 Fax: 1.888.329.8328 Europe: Vectron International Landstrasse, D-74924 Neckarbischofsheim, Germany Tel: +49 (0) 3328.4784.17 Fax: +49 (0) 3328.4784.30 Asia: Vectron International 1F-2F, No 8 Workshop, No 308 Fenju Road WaiGaoQiao Free Trade Zone Pudong, Shanghai, China 200131 Tel: 86.21.5048.0777 Fax: 86.21.5048.1881 Disclaimer Vectron International reserves the right to make changes to the product(s) and or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Rev: 5/7/2009 daf Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com