Emerson Network Power AGQ200-48S1V2P-4L Delivering up to 40a output current Datasheet

48Vdc Input, 1.2Vdc@40A Output Quarter-brick
DC-DC Converter AGQ200-48S1V2
Description
The AGQ200-48S1V2 is a single output
DC-DC converter with standard quarter-brick
outline and pin configuration. It delivers up to
40A output current with 1.2V output voltage.
Above 85% efficiency and excellent thermal
performance make it an ideal choice to supply
power in telecom and datacom. It can work
under -40°C ~ +85°C.
Operational Features
Delivering up to 40A output current
Ultra-high efficiency 85% typ. at full load
Wide input range: 36V ~ 75V
Excellent thermal performance
No minimum load requirement
Fixed frequency operation
RoHS 6 compliant
Control Features
Remote control function
Remote output sense
Trim function: -20% ~ +10%
Protection Features
Input under voltage lockout
Output over current protection
Output over voltage protection
Over temperature protection
Document NO. 31020961
Mechanical Features
Industry standard quarter-brick pin-out
outline
Open frame or baseplate optional
Pin length option: 3.8mm, 4.8mm, 5.8mm
Safety & EMC
Meets safety standards UL 60950-1,
CSA-C22.2 NO. 60950-1, IEC/EN
60950-1 and GB4943
Approved by UL and TUV
Meets 2006/95/EEC and 93/68/EEC
directives which facilitates CE marking in
user’s end product
Meets conducted emission's requirements
of EN55022 Class A with external filter
December 1, 2009
Rev 1.2
2/13
AGQ200-48S1V2 DC-DC Converter
Electrical Characteristics
Full operating ambient temperature range is -40°C to +85°C.
Specifications are subject to change without notice.
Parameter
Min.
Typ.
Max.
Unit
Notes & Conditions
Absolute max. ratings
Input Voltage
Non-operating
100
V
100ms
Operating
80
V
Continuous
Operating temperature
-40
85
°C
Storage temperature
-55
125
°C
Voltage at remote ON/OFF pin
-0.7
12
V
Input characteristics
Operating input voltage range
Input
under-voltage
lockout
36
48
75
V
Turn-on voltage
threshold
31
34
36
V
Turn-off voltage
threshold
30
33
35
V
Lockout voltage
hysteresis
1
3
V
2
A
Max. input current
36Vin, full load
No-load input current
0.07
0.1
A
Standby Input current
0.01
0.1
A
1
A2 s
20
mA
Through 12µH inductor, Figure 4
dB
120Hz
A
Fast blow external fuse
recommended, Figure 11
Inrush current transient rating
Input reflected ripple current
7
Input voltage ripple rejection
40
70
Recommended input fuse
15
Remote OFF
Input filter component values (C\L)
6.4\2.2
µF\µH
Internal values
Recommended external input
capacitance
100
µF
Low ESR capacitor
recommended, Figure 11
1.22
V
48Vin, full load
Output characteristics
Output voltage set point (standard
option)
1.18
1.20
Output voltage line regulation
0.12
5
mV
Output voltage load regulation
0.18
10
mV
0.02
%/°C
Output voltage temperature
regulation
http://www.emersonnetworkpower.com.cn
3/13
AGQ200-48S1V2 DC-DC Converter
Parameter
Min.
Total output voltage range
Typ.
1.18
1.20
Output voltage ripple and noise
45
Max.
Unit
1.22
V
100
mVpp
Notes & Conditions
20MHz bandwidth; Figure 3
Operating output current range
0
40
A
Output DC current-limit inception
44
56
A
Hiccup: auto-restart when
over-current condition is removed
Output capacitance
470
15000
µF
High frequency and low ESR are
recommended
Dynamic characteristics
Dynamic
response
Turn-on
transient
25% ~ 50% ~ 25%
Io,max, 0.1A/µs
30
mV
Figure 5
Settling time
120
µs
Recovery to within 1% Vo,nom
25% ~ 50% ~ 25%
Io,max, 1A/µs
141
mV
Figure 6
Settling time
85
µs
Recovery to within 1% Vo,nom
0% ~ 50% ~ 0% Io,max,
0.1A/µs
45
mV
10% ~ 100% ~ 10%
Io,max, 0.1A/µs
35
mV
Rise time
5
30
ms
Turn-on delay time
3
10
ms
5
%Vo
Output voltage
overshoot
Full load, Figures 9 & 10
Efficiency
100% load
85.0
%
Figure 1
50% load
86.6
%
Figure 1
Electrical Characteristics (Continued)
Parameter
Min.
Typ.
Max.
Unit
Notes & Conditions
Isolation characteristics
Isolation voltage (conditions:
1mA for 60s, slew rate of
1500V/10s)
2250
V
Basic insulation, pollution degree 2,
pollution degree 2, input to output
http://www.emersonnetworkpower.com.cn
4/13
AGQ200-48S1V2 DC-DC Converter
Parameter
Min.
Typ.
Max.
Unit
Notes & Conditions
Feature characteristics
Switching frequency
Remote ON/OFF
control (positive
logic)
Remote ON/OFF
control
(negativelogic N)
280
kHz
Off-state
voltage
-0.7
1.2
V
On-state
voltage
3.5
12
V
Off-state
voltage
3.5
12
V
On-state
voltage
-0.7
1.2
V
0.96
1.32
V
0.5
V
Output voltage trim range
Regulation stage and Isolation stage
See Figure 12
Output voltage remote sense
range
See Trim Characteristics of Application
Note
Output over-voltage
protection
120
140
%Vo,nom
Over-temperature shutdown
110
135
°C
Over-temperature hysteresis
5
Hiccup: auto-restart when over-voltage
condition is removed
Auto recovery;
Test point: see Figure 18
°C
Reliability characteristics
Calculated MTBF (telcordia)
2
106h
Telcordia SR-332-2006; 80% load,
300LFM, 40°C Ta
Qualification Testing
Parameter
Halt test
Vibration
Unit (pcs)
Test condition
4~5
Ta,min-10°C to Ta,max+10°C, 5°C step, Vin=min to max, 0 ~ 105% load
3
Frequency range: 5Hz ~ 20Hz, 20Hz ~ 200Hz, A.S.D: 1.0m2/s3, -3db/oct,
axes of vibration: X/Y/Z
Time: 30min/axis
Mechanical shock
3
30g, 6ms, 3axes, 6directions, 3time/direction
Thermal shock
3
-40°C to 100°C, unit temperature 20cycles
Thermal cycling
3
-40°C to 55°C, temperature change rate: 1°C/min, cycles: 2cycles
Humidity
3
40°C, 95%RH, 48h
Solder ability
15
IPC J-STD-002C-2007
http://www.emersonnetworkpower.com.cn
5/13
AGQ200-48S1V2 DC-DC Converter
Characteristic Curves
95
90
85
Effiency (%)
80
75
70
Vin=36V
65
Vin=48V
60
Vin=75V
55
4
8
12
16
20
24
28
32
36
40
Output current (A)
Figure 1
Efficiency vs. output current, Ta=25°C, Vo=2.5V
40
32
24
Output current Io (A)
16
Figure 2
8
0
25
40
55
70
85
Temperature: Ta (℃)
400LFM(2m/s)
300LFM(1.5m/s)
100LFM(0.5m/s)
0LFM(0m/s)
200LFM(1m/s)
Output power derating, 48Vin, air flowing across the converter from pin 1 to pin 3
http://www.emersonnetworkpower.com.cn
6/13
AGQ200-48S1V2 DC-DC Converter
Figure 3 Output ripple & noise (2µs/div, 10mV/div),
see Figure 15 for test configuration
Figure 4
Input reflected ripple current (2µs/div,
5mA/div), see Figure 15 for test configuration
Figure 5 Dynamic response for 25% load step (25%
~ 50% ~ 25%) and 0.1A/µs slew rate, (2ms/div), see
Figure 11 for test configuration; CH1-output voltage
(20mV/div); CH2-output current (20A/div)
Figure 6 Dynamic response for 25% load step (50%
~ 75% ~ 50%) and 1A/µs slew rate, (2ms/div), see
Figure 11 for test configuration; CH1-output voltage
(50mV/div); CH2-output current (20A/div)
Figure 7
Output voltage startup by power on,
(2ms/div), see Figure 11 for test configuration;
CH1-input voltage (20V/div); CH2-output voltage
(0.5V/div)
Figure 8 Output voltage shut down by power off,
(5ms/div), see Figure 11 for test configuration;
CH1-input voltage (20V/div); CH2-output voltage
(0.5V/div)
http://www.emersonnetworkpower.com.cn
7/13
AGQ200-48S1V2 DC-DC Converter
Figure 9 Output voltage startup by remote ON
(2ms/div), see Figure 11 for test configuration;
CH1-remote ON (5V/div); CH2-output voltage
(0.5V/div)
Figure 10 Output voltage shutdown by remote OFF,
(2ms/div), see Figure 11 for test configuration;
CH1-remote OFF voltage (5V/div); CH2-output voltage
(1V/div)
http://www.emersonnetworkpower.com.cn
8/13
AGQ200-48S1V2 DC-DC Converter
Application Note
Typical Application
AGQ200
EMI Filter
Fuse
In+
Out+
Vdc
C1
C2
Vin+
Vo+
S+
CNT
Trim
Vin-
Vo-
C3
C4
Load
SIn-
Out-
Figure 11
Typical application
C1: 100µF/100V electrolytic capacitor, P/N: UVZ2A101MPD (Nichicon) or equivalent caps
C2: 1µF/100V X7R ceramic capacitor
C3: 1µF/25V X7R ceramic capacitor
C4: 470µF/25V electrolytic capacitor, P/N: UPM1E471MPD (Nichicon) or equivalent caps
External fast blow fuse with a rating of 15A should be used in the application.
If the load is far from the unit, connect S+ and S- to the terminal of the load respectively to
compensate the voltage drop on the transmission line.
Remote ON/OFF
Either positive or negative remote ON/OFF logic is available in AGQ200-48S1V2. The following
figure is the detailed internal circuit and reference in AGQ200-48S1V2.
12V
Remote
ON/OFF
15k
12V
19.7k
PWM
controller
Remote
ON/OFF
+Vin
15k
85.6k
PWM
controller
UVLO
4.7k
6.8k
Negative logic
Figure 12
Positive logic
Remote ON/OFF internal diagram
http://www.emersonnetworkpower.com.cn
9/13
AGQ200-48S1V2 DC-DC Converter
Trim Characteristics
Connecting an external resistor between Trim pin and Vo- pin will decrease the output voltage.
While connecting it between Trim and Vo+ will increase the output voltage. The following equations
determine the external resistance to obtain the trimmed output voltage.
510
− 10.2(kΩ)
∆
5.1 × Vnom × (100 + ∆ ) 510
−
− 10.2(kΩ)
=
∆
0 .6 × ∆
Rtrim − down =
Rtrim − up
△=(Vo-Vnom)×100/Vnom
Vnom : Nominal output voltage
For example, to get 1.32V output, the trimming resistor is
Rtrim−up =
5.1 × 1.2 × (100 + (1.32 − 1.2) × 100 / 1.2 )
510
−
− 10.2 = 51(kΩ)
0.6 × (1.32 − 1.2) × 100 / 1.2
(1.32 − 1.2) × 100 / 1.2
The output voltage can also be trimmed by potential applied at the Trim pin.
Vo = Vtrim + 0.6
Where V trim is the potential applied at the Trim pin, and V o is the desired output voltage.
When trimming up, the output current should be decreased accordingly so as not to exceed the
maximum output power.
Vo+
Vo+
S+
S+
Load
Load
Trim
Rtrim_up
Trim
Cout
Cout
S-
S-
Vo-
Vo-
Figure 13
Rtrim_down
Trim up
Figure 14
Trim down
http://www.emersonnetworkpower.com.cn
10/13
AGQ200-48S1V2 DC-DC Converter
Input Ripple & Inrush Current And Output Ripple & Noise Test
Configuration
Probe
Current probe
L1
50mm
Vin+
Vdc
Cin
C1
C2
Vo+
Vin-
Figure 15
C3
DC/DC
C4
Load
Vo-
Input ripple & inrush current, ripple & noise test configuration
Vdc: DC power supply
L1: 12µH
Cin: 220µF/100V typical.
C1 ~ C4: See Figure 11
EMC Filter Configuration
U1
In+
U2
Out+
1320uH
1000nF/100V
Vin+
22nF/1000V
C1
C2
Out-
C3
DC/DC
22nF/1000V
In-
V o+
Vin -
C4
Vo-
Resistive load
EMI Filter
PE
Figure 16
EMC test configuration
U1: 5A input EMC filter module
U2: Module to test, AGQ200-48S1V2
C1 ~ C4: See Figure 11
http://www.emersonnetworkpower.com.cn
11/13
AGQ200-48S1V2 DC-DC Converter
Mechanical Diagram
50.83 [2.001]
4
5
2
6
7
1
8
6-Ф2.0±0.1
L
12.7[0.500]MAX
Side view
0.3[0.012]MIN
15.24 [0.600]
36.8 [1.449]
Bottom view
3
7.62[0.300]
15.24 [0.600]
57.9 [2.280]
6-Ф1.0±0.1
2-Ф1.5±0.1
Load board
Unit: mm[inch]
Bottom view: pin on upside
Tolerance: X.Xmm±0.5mm[X.X in.±0.02in.]
X.XXmm±0.25mm[X.XX in.±0.01in.]
Figure 17
Mechanical diagram
Pin length options
Device code suffix
L
-4
4.8mm±0.2mm
-6
3.8mm±0.2mm
-8
2.8mm±0.2mm
None
5.8mm±0.2mm
http://www.emersonnetworkpower.com.cn
12/13
AGQ200-48S1V2 DC-DC Converter
Pin Designations
Pin NO.
Name
Function
1
Vin+
Positive input voltage
2
Remote ON/OFF
Remote control
3
Vin-
Negative input voltage
4
Vo -
Negative output voltage
5
S-
Negative remote sense
6
Trim
Output voltage trim
7
S+
Positive remote sense
8
Vo +
Positive output voltage
Soldering
The product is intended for standard manual or wave soldering.
When wave soldering is used, the temperature on pins is specified to maximum 260°C for
maximum 7s.
When manual soldering is used, the iron temperature should be maintained at 300°C ~ 380°C and
applied to the converter pins for less than 10s. Longer exposure can cause internal damage to the
converter.
Cleaning of solder joint can be performed with cleaning solvent IPA or similative.
Thermal Considerations
Note: When the temperature of this
test point is lower than 100℃, the
module thermal reliability is available
Figure 18
Temperature test point on converter
http://www.emersonnetworkpower.com.cn
13/13
AGQ200-48S1V2 DC-DC Converter
Ordering Information
AGQ200
-
①
48
S
1V2
P
B
②
③
④
⑤
⑥
-
4
L
⑦
⑧
①
Model series
AGQ: series name, 200: rated output power 200W. The lower output is
limited by its current
②
Input voltage
48: 36V ~ 75V input range, rated input voltage 48V
③
Output number
S: single output. D:dual output
④
Rated output voltage
1V2: 1.2V output
⑤
Remote ON/OFF logic
Default: negative logic; P: positive logic
⑥
Baseplated
Baseplated. Default: no baseplate.
⑦
Pin length
-4: 4.8±0.2mm
⑧
RoHS status
L: RoHS, R6
Model number
Description
AGQ200-48S1V2-4L
4.8mm pin length; negative on/off logic; no baseplate; R6 compliant
AGQ200-48S1V2P-4L
4.8mm pin length; positive on/off logic; no baseplate; R6 compliant
AGQ200-48S1V2B-4L
4.8mm pin length; negative on/off logic; baseplated; R6 compliant
AGQ200-48S1V2PB-4L
4.8mm pin length; positive on/off logic; baseplated; R6 compliant
Hazardous Substances Announcement (RoHS Of China)
Parts
AGQ200-48S1V2
Hazardous substances
+
Pb
Hg
Cd
Cr6+
PBB
PBDE
○
○
○
○
○
○
○: Means the content of the hazardous substances in all the average quality materials of the part is within the limits
specified in SJ/T-11363-2006
√: Means the content of the hazardous substances in at least one of the average quality materials of the part is
outside the limits specified in SJ/T11363-2006
Emerson Network Power Co., Ltd. has been committed to the design and manufacturing of environment-friendly
products. It will reduce and eventually eliminate the hazardous substances in the products through unremitting
efforts in research. However, limited by the current technical level, the following parts still contain hazardous
substances due to the lack of reliable substitute or mature solution:
1. Solders (including high-temperature solder in parts) contain plumbum.
2. Glass of electric parts contains plumbum.
3. Copper alloy of pins contains plumbum
http://www.emersonnetworkpower.com.cn
Similar pages