OPLINK BTMS310050051 Bi-directional single channeltap monitor Datasheet

Bi-directional Single Channel
Integrated Tap Monitors
BTMS Series
Product Description
Oplink’s Single Channel Bi-directional Integrated Tap Monitor (BTMS) is a hybrid component
that integrates a flat spectral response of a thin-film tap with a high sensitivity PIN photodiode
for power monitoring applications. The Bi-directional feature allows power monitoring from
both input and output ports. BTMS minimizes component assembly costs and module footprint while increasing module design efficiency by facilitating fiber management.
The BTMS integrates the functionality of an optical coupler and a photodiode while delivering
low insertion loss and low dark current with high temperature stability over a wide wavelength
range. It is compact and easy to mount on a PCB board for module and network system use.
Applications include DWDM channel power monitoring, optical network switching/protection
monitoring, re-configurable optical add/drop multiplexers systems.
Oplink can provide customized designs to meet specialized feature applications. Also, Oplink
offers modular assemblies that integrate other components to form a full function module or
subsystem.
Functional Diagram
Output
Input
Features
 2-/3-pin Package Easily Mounted
on a PCB
PD
 Flat and Broad Operating
Wavelength Range
 Low Insertion Loss and PDL
Performance Specificationns
Parameters
Specification
Operating Wavelength Range
Through
Tapped
Monitoring
PD
mm
 Various Tap Ratios Available
dB
 High Temperature Stability with
Hermetically Sealed Photodiode
Polarization Dependent Loss
≤ 0.1
dB
 Monitor Optical Signal from One
Both Input and Output
Return loss (exclude connector)
≥ 45
dB
Responsivity (relative to nominal power at
input port)
2%
5%
10%
2%
5%
10%
10~23
26~59
52~110
14~25
35~65
70~120
mA/W
Applications
Responsivity Polarization Dependence
≤ 0.1
dB
 EDFAs and Raman amplifiers
Uniformity
≤ 0.5
dB
PD Dark Current (@ 70°C, -5V bias)
≤ 10
nA
 Add/Drop and optical protection
monitoring
Bandwidth (50 ohm, 5V, -3dB)
≥ 0.5
GHz
 DWDM/CWDM systems
Reverse Voltage
≤ 20
V
Forward Current
≤5
mA
≤ 21
≤ 16
≤ 12
dBm
0 to +70
°C
-40 to +85
°C
[1]
2%
5%
10%
Operating Temperature Range (<85%RH, Non-condensing)
Storage Temperature Range (<85%RH, Non-condensing)
Fiber Type
1510~1610
 Low Dark Current
≤ 0.4
≤ 0.6
≤ 0.9
Insertion Loss (@ λOp, TOp, All SOP, exclude
connector)
Input Optical Power
Conditions
1260~1360
Unit
SMF-28
Notes:
[1]
Excluding connectors.
S0003 - R03. 20100601
Bi-directional Single Channel Integrated Tap Monitors
BTMS Series
Mechanical Drawing / Package Dimensions (dimension in mm)
Standard Package (P1, Bare Fiber or Loose Tube)
Miniature Package (P2, Bare Fiber)
Input(Black)
ф0.45 mm Lead, ≥12mm
Note:
Anode is connected to the metal housing.
ф2. 5 mm
Standard Package Pin Assignment
46335 Landing Pkwy Fremont, CA 94538 Tel: (510) 933-7200 Fax: (510) 933-7300 Email: [email protected] • www.oplink.com
Pin 1:
Pin 2:
Pin 3:
Anode
Cathode
Case Ground
Miniature Package (P3, Loose Tube)
Input(Blue)
Output(White)
Note:
Anode is connected to the metal housing.
Ordering Information
Oplink can provide a remarkable range of customized optical solutions. For detail, please contact Oplink’s OEM
design team or account manager for your requirements and ordering information (510) 933-7200.
0
BTMS
Tap Ratio
2/98 = 02
5/95 = 05
10/90 = 10
5
Bandwidth
0.5G= 05
Wavelength
1310/1550nm= D
1310nm= 3
C+L band= E
0
0
Fiber Length
0.5meter= H
1.0meter= 1
1.5meter= 5
2.0meter= 2
Package & Fiber Type
P1+250µm bare fiber =11
P1+900µm loose tube =12
P2+250µm bare fiber = 21
P3+900µm loose tube = 32
Connector
Type
None = 1
FC/PC=2
FC/SPC=3
FC/APC=4
SC/PC=5
SC/SPC=6
SC/APC=7
ST=8
LC=9
MU=A
RoHS:
1. Add “G” to the end of the above PN for RoHS 6 Requirement.
S0003 - R03. 20100601
Product Lines:  Mux/Demux  Switching/Routing  Coupling/Splitting  Monitoring/Conditioning  Amplification  Transmission  Interconnect  RGB Laser Modules
Similar pages