Vectron EX-245 Hi-reliability evacuated miniature crystal oscillator Datasheet

EX-245
Hi-Reliability Evacuated Miniature Crystal Oscillator
EX-245
Features
16 pin Double Dip Package
Ruggedized hybrid thick film construction
Low Power Consumption
Typical Applications
Severe Environmental Conditions
10 MHz – 40 MHz
10, 20 MHz
Frequency Range
Standard Frequencies
Frequency stabilities1 [10 to 20 MHz]
Min
Max
Units
-50
+50
ppb
0 … +60°C
(Referenced to +25°C)
-75
+75
ppb
-20 … +70°C
-100
+100
ppb
-40 … +85°C
Max
Units
Condition
+1
+0.2
+15
+15
+2
+200
+1000
+1500
+2000
ppm
ppm
ppb
ppb
ppb
ppb
ppb
ppb
ppb
Fixed, no adjust option
120
seconds
to ± 1ppm of final freq. @+25°C
180
seconds
to ± 100ppb of final freq. @+25°C
Parameter
Min
Initial tolerance For Fixed Freq.
Settability
vs. supply voltage change
vs. load
vs. aging / day
vs aging / 1 year
vs. aging /10 year
vs. aging /10 year
vs. aging /10 year
-1
-0.2
-15
-15
-2
-200
-1000
-1500
-2000
Warm-up Time
Typ
Typ
Operating temp range
Options5
Parameter
vs. operating temperature range
VS ± 5%
Load ± 5%
after 7 days of operation
10 to <12MHz
12 to <16MHz
16 to 20MHz
http://www.vectron.com Rev. 02-06-09 daf
Vectron International•267 LowellRoad, Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1
Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100
Frequency stabilities1 [>20 to 40 MHz]
Min
vs. operating temperature range
(Referenced to +25°C)
Max
Units
-75
+75
ppb
0 … +60°C
-100
+100
ppb
-20 … +70°C
-150
+150
ppb
-40 … +85°C
Max
Units
Condition
+1.5
+0.3
+25
+25
+3
+300
+3000
ppm
ppm
ppb
ppb
ppb
ppb
ppb
Fixed, no adjust option
VS ± 5%
Load ± 5%
after 7 days of operation
120
seconds
to ± 1ppm of final freq. @+25°C
180
seconds
to ± 100ppb of final freq. @+25°C
Parameter
Min
Initial tolerance For Fixed Freq.
Settability
vs. supply voltage change
vs. load
vs. aging / day
vs aging / 1 year
vs. aging /10 year
-1.5
-0.3
-25
-25
-3
-300
-3000
Typ
Typ
Warm-up Time
Operating temp range
Options5
Parameter
Supply Voltage (Vs)
Parameter
Supply voltage [Standard]
Min
Typ
Max
Units
4.75
5
5.25
VDC
2.2
Watts
during warm-up
0.7
Watts
steady state @ +25°C
1.2
Watts
steady state @ -40°C
Power consumption
Condition
RF Output
Parameter
Min
Typ
Signal [Standard]
Max
15
Signal Level (Vol)
Load
Output Power [Standard]
Output Power [Option]
Harmonics
Spurious
Condition
HCMOS
Load
Signal Level (Voh)
Rise/Fall Time
Duty cycle
Signal [Option]
Units
pF
0.1
0.9
40
0.0
3.0
+7
60
Sinewave
50
+2.0
+5.0
4.0
7.0
-25
-60
VDD
VDD
ns
%
Ω
dBm
dBm
dBc
dBc
(10-90%)
@ (Voh-Vol)/2
50 Ohm load
50 Ohm load
Frequency Tuning (EFC)
Min
Typ
Max
Units
Tuning Range
Fixed, No Adjust
Tuning Range
Sufficient to compensate for 10 years aging
Vref
4.0
4.1
4.2
Vdc
Condition
EFC (0V to 4V)
Options5
Parameter
Source Current 1mA maximum
http://www.vectron.com
Vectron International•267 LowellRoad, Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1
Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100
Additional Parameters1 [10 to 20 MHz]
Parameter
Phase Noise
G-Sensitivity
Max.
Units
Condition
-100
dBc/Hz
10
-125
dBc/Hz
100
Hz
-140
dBc/Hz
1
kHz
-145
dBc/Hz
10
kHz
-145
dBc/Hz
1 x 10-9
/g
Hz
10 to 20 MHz
100
kHz
Test at 10g sine vibration at 100Hz
Additional Parameters1 [>20 to 40 MHz]
Parameter
Phase Noise
G-Sensitivity
Max.
Units
Condition
-90
dBc/Hz
10
Hz
-115
dBc/Hz
100
Hz
-130
dBc/Hz
1
kHz
-140
dBc/Hz
10
kHz
-140
dBc/Hz
1 x 10-9
/g
> 20 to 40 MHz
100
kHz
Test at 10g sine vibration at 100Hz
Environmental Conditions (Designed to meet)
• Radiation Tolerant (operating):
Active devices are selected from a family of product that is inherently
radiation tolerant to meet 100krad (SI) total dose
• Mechanical Shock (survive)***:
MIL-STD-202, Test Method 213, Condition E (1000G, 0.5msec)
• Vibration Random (survive)***:
MIL-STD-202, Test Method 214, Condition I-F (20Grms, 3 minutes/axis)
• Vibration Sine (survive)***:
MIL-STD-202, Test Method 204, Condition D (20Grms, 20 minutes/axis)
Note: *** Met by design, not tested
http://www.vectron.com
Vectron International•267 LowellRoad, Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1
Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100
Screening Options
Ordering Code
S
B
Test Inspection
S-Level Screening
B-Level Screening
Nondestructive Bond Pull
MIL-STD-883
Method 2023
N/A
Internal Visual Per Mil-PRF-55310
Requirement
Internal Visual Per Mil-PRF-55310
Requirement
Internal Visual Per Mil-PRF-55310
Requirement
Stabilization Bake
MIL-STD-883
Method 1008,
Condition C
150°C for 48hrs
MIL-STD-883
Method 1008,
Condition C
Thermal Shock
MIL-STD-883
Method 1011,
Condition A
0°C to 100°C for
15cycles
N/A
Temperature Cycling (1)
MIL-STD-883
Method 1010,
Condition A
-55°C to 85°C (2)
for 10cycles
MIL-STD-883
Method 1010,
Condition A
-55°C to 85°C (2)
for 10cycles
Constant Acceleration (1)
MIL-STD-883
Method 2001
1000g’s (3)
Y1 Only
MIL-STD-883
Method 2001
1000g’s (3)
Y1 Only
Seal (Fine & Gross Leak) (1)
N/A (Vacuum Seal)
PIND
MIL-STD-883
Method 2020,
Condition B
150°C for 48hrs
N/A (Vacuum Seal)
10g peak at 60Hz
minimum
N/A
Electrical Test
Per Mil-PRF-55310 Requirement
Per Mil-PRF-55310 Requirement
Burn-in (1)
85°C (2) for 240hrs
85°C (2) for 240hrs
Electrical Test
Per Mil-PRF-55310 Requirement
Per Mil-PRF-55310 Requirement
Radiographic
MIL-STD-883
Method 2012
N/A
Note:
(1) These test inspections deviate from screening requirements for class 2 oscillator in MIL-PRF-55310.
(2) The maximum operating and storage temperature of the EX-245 is +85°C. The EX-245 shall not be exposed to temperature higher than
+85°C at length of time.
(3) The design and construction of the EX-245 can withstand up to 1000g’s constant acceleration
http://www.vectron.com
Vectron International•267 LowellRoad, Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1
Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100
Package Outline
Pin Function
Pin # With EFC
Fixed Frequency
1
EFC
No Connection
2-4
No Connection No Connection
8
Case/GND
Case/GND
9
Output
Output
13-14 No Connection No Connection
15
Vref
No Connection
16
Supply
Supply
**Pin numbers are for reference
Reflow Profile
Reflow
Profile
o
TEMPERATURE ( C)
220
183
150
60s
60-90s
45-60s
TIME (s)
http://www.vectron.com
Vectron International•267 LowellRoad, Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1
Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100
How to order this product:
Use this worksheet to forward the following information to your factory representative :
Model
-
EX-245
-
Model Code:
245: Type A
S u p p l y RF Output Temperature
Vo l t a g e
Code
Range
Code
C
A
D
Supply Voltage
Code:
C: 5 V
Stability
Options
-
508
A
S
S
-
Frequency
-
10M0000000
Crystal Options:
S: Swept Quartz
N: Non-Swept Quartz
Temperature Range:
K: 0 ... +60°C
D: -20...+70°C
F: -40...+85°C
Screening Option:
S: “S” Level Screening
B: “B” Level Screening
E: “EM” Engineering Model
RF Output Code:
A: CMOS
G: Sinewave (0 dBm)
H: Sinewave (+3 dBm)
Other Options:
A: Electrical Tuning
F: Fixed Frequency
Stability:
508: ±50ppb
758: ±75ppb
107: ±100ppb
157: ±150ppb
Notes:
1
2
3
4
5
Contact factory for improved stabilities or additional product options. Not all options and codes are
available at all frequencies.
Unless otherwise stated all values are valid after warm-up time and refer to typical conditions for supply
voltage, frequency control voltage, load, temperature (25°C)
Phase noise degrades with increasing output frequency.
Subject to technical modification.
Contact factory for availability.
http://www.vectron.com
Vectron International•267 LowellRoad, Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1
Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100