Crystek CCPD-034M-311.040 Lvpecl clock oscillator 5x7mm smd 3.3 volt Datasheet

CCPD-034 LVPECL
Clock Oscillator
5x7mm SMD
3.3 Volts
Model CCPD-034 is a 162.000MHz to 312.500MHz LVPECL
Clock Oscillator operating at 3.3Volts. The oscillator utilizes
a High Q Third Overtone crystal design providing very low
Jitter and Phase Noise. No Sub-Harmonics are present in
the Ouput Signal.
5x7mm SMD
Applications:
Digital Video
SONET/SDH/DWDM
Storage Area Networks
Broadband Access
Ethernet, Gigabit Ethernet
Rev.: L
Date: 05-13-08
CCPD-034 LVPECL
Clock Oscillator
5x7mm SMD
3.3 Volts
Frequency Range:
162.000MHz to 312.500MHz
Temperature Range: (standard)
(Option M)
(Option X)
0°C to +70°C
-20°C to +70°C
-40°C to +85°C
Storage:
Input Voltage:
Input Current:
-55°C to 120°C
3.3V ± 0.3V
55mA Typ., 88mA Max
Output:
Symmetry:
Rise/Fall Time:
Differential LVPECL
45/55% Max @ 50%Vdd
1nsec Max @ 20% to 80% Vdd
Frequency Stability Options(ppm):
±20, ±25, ±50, ±100
Logic: Terminated to Vdd-2V into 50 ohms
Temp. 0°C to 85°C
“0”=1.490 Min., 1.680 Max
“1”=2.275 Min., 2.420 Max
Temp. -40°C to 0°C
“0”=1.470 Min., 1.745 Max
“1”=2.215 Min., 2.420 Max
Disable Time
200nSec Max
Start-up Time
1mSec Typ., 2mSec Max
Phase Jitter:
12KHz~80MHz
0.5psec Typ., 1psec RMS Max
Phase Noise:
(See Plot Below)
Sub-harmonics:
None
Aging:
<3ppm 1st year, <2ppm every year thereafter
Actual CCPD-034X-50-311.040MHz Plot
Rev.: L
Date: 05-13-08
CCPD-034 LVPECL
Clock Oscillator
5x7mm SMD
3.3 Volts
PART NUMBER GUIDE
CCPD - 034 X - 50 - 311.040
#1
#2 #3
#4
#5
#1 Crystek PECL Oscillator.
#2 Model 034
#3 Temp. Range (Blank=0/70°C)(M=-20/70°C)(X=-40/85°C)
#4 Stability: (see Table 1)
#5 Frequency in MHz: 3 or 6 decimal places
Blank(std)
±100ppm
50
±50ppm
25
±25ppm
20
±20ppm
Example:
CCPD-034X-50-311.040
3.3V, -40/85°C, ±50ppm, 311.0400 MHz
Shock:
Solderability:
Vibration:
Solvent Resistance:
Resistance to Soldering Heat:
Table 1
RECOMMENDED REFLOW SOLDERING PROFILE
MIL-STD-883, Method 2002, Condition B
MIL-STD-883, Method 2003
MIL-STD-883, Method 2007, Condition A
MIL-STD-202, Method 215
MIL-STD-202, Method 210, Condition I or J
Ramp-Up
3°C/Sec Max.
260°C
200°C
150°C
Preheat
180 Secs. Max.
8 Minutes Max.
Thermal Shock: MIL-STD-883, Method 1011, Condition A
Moisture Resistance: MIL-STD-883, Method 1004
NOTE: Reflow Profile with 240°C peak also acceptable.
0.193 ±0.007
(4.90 ±0.18)
0.075
(1.80)
0.045 ±0.008
(1.14 ±0.20)
#1
#2
#3
#6
#5
#4
1
4
0.154
(3.91)
0.071
(1.80)
0.100
(2.54)
0.200
(5.08)
5
1
2
3
0.100
(2.54)
Open or N/C
Pad
0.01µF
6
Pin #1
State
Output
State
“0” level 0.3*Vcc Max
0.050
(1.27)
via to
ground
Tri-State Function
“1” level 0.7*Vcc Min
SUGGESTED PAD LAYOUT
Denotes pad 1
0.055 Typ
(1.40 Typ)
90 Secs. Max.
260°C for
10 Secs. Max.
Dimensions inches (mm)
All dimensions are Max unless otherwise specified.
Part Number
Frequency
DC Lot Code
Critical
Temperature Zone
Ramp-Down
6°C/Sec.
217°C
Environmental:
0.274 ±0.007
(6.96 ±0.18)
(±50ppm, 0/70°C)
200.000MHz
212.500MHz
250.000MHz
311.040MHz
312.500MHz
TEMPERATURE
Mechanical:
Standard Frequencies
Stability Indicator
Active
Active
High Z
Connection
Enable/Disable
2
N/C
3
GND
4
Out
5
Comp. Out
6
VCC
0.200
(5.08)
Rev.: L
Date: 05-13-08
Similar pages