DCW12 12W DC-DC Regulated Dual Output Converter series Features : 2:1 wide input range 1500VDC I/O isolation Built-in remote ON/OFF control Built-in EMI filter Protections: Short circuit / Overload Cooling by free air convection Five-sided shield metal case 100% full load burn-in test Low cost / High reliability 2 years warranty SPECIFICATION ORDER NO. DCW12A-05 DCW12B-05 DCW12C-05 DCW12A-12 DCW12B-12 DCW12C-12 DCW12A-15 DCW12B-15 DCW12C-15 DC VOLTAGE 5V 12V 15V CURRENT RANGE 240 ~ 1200mA 100~ 500mA 80 ~ 400mA RATED POWER OUTPUT 12W RIPPLE & NOISE (max.) Note.2 50mVp-p LINE REGULATION Note.3 0.5% LOAD REGULATION Note.4 VOLTAGE ACCURACY 2.0% 400KHz min. VOLTAGE RANGE A: 9 ~ 18VDC B: 18 ~ 36VDC C: 36 ~ 72VDC 80% 80% 81% 84% Full load DC CURRENT A: 1245mA B: 625mA No load A: 70mA Pi network FILTER B: 35mA 84% 84% 84% 83% 83% C: 320mA C: 25mA Fuse recommended PROTECTION 110 ~ 180% rated output load Protection type : Hiccup mode, recovers automatically after fault condition is removed All output equipped with over current protection OVERLOAD PROTECTION Note.5 SHORT CIRCUIT Protection type : Hiccup mode, recovers automatically after fault condition is removed WORKING TEMP. -40 ~ +71 WORKING HUMIDITY 20% ~ 90% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION WITHSTAND VOLTAGE ISOLATION RESISTANCE SAFETY & ISOLATION CAPACITANCE EMC EMI CONDUCTION & RADIATION EMS IMMUNITY OTHERS 60mVp-p 0.5% SWITCHING FREQUENCY EFFICIENCY (Typ.) INPUT 60mVp-p REMOTE CONTROL MTBF (refer to output load derating curve) -40 ~ +105 0.05% / , 10 ~ 95% RH (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes I/P-O/P:1.5KVDC I/P-O/P: 100M Ohms / 500VDC / 25 / 70% RH 2200pF max. Compliance to EN55022 Class A, FCC part 15 Class A Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A Power ON: R.C. ~ -Vin > 4VDC or open ; Power OFF: R.C. ~ -Vin < 1VDC or short 600Khrs min. MIL-HDBK-217F (25 DIMENSION ) 31.8*20.3*12.2mm (L*W*H) or 1.25"*0.80"*0.48" inch (L*W*H) 18.5g PACKING Derating Curve Pin Configuration Mechanical Specification Unit:mm(inch) + 0.2/-0 22 3 BOTTOM VIEW 16 9 14 11 2.54( 0.10 ) 3.81(0.15) SIDE VIEW 5.08( 0.20 ) 15.24(0.60) 12.2(0.48) Pin No. Output 1 2&3 9 11 14 16 22 & 23 R.C. - Vi n COM - Vo u t + Vo u t COM + Vi n 100 LOAD (%) 23 17.8(0.70) 2.54( 0.10 ) 1 2 31.8(1.25) 0.6 20.3(0.80) 60 -40 0 25 50 60 71 Ta ( NOTE 100 ) 1.All parameters are specified at normal input, rated load, 25 70% RH ambient. 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 3.Line regulation is measured from low line to high line at rated load. 4.Load regulation is measured from 20% to 100% rated load. 5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds. File Name:DCW12-SPEC 2011-03-08