XP Power AEL20US48 Ac-dc power supply Datasheet

AC-DC
15 Watts
xppower.com
AEL Series
•
CEC 2008 & EISA 2007 Compliant
•
Approved as LPS
•
China Compulsory Certfication (CCC) Qualified
•
High Efficiency
•
+70 °C Operating Temperature
•
Compact Dimensions
•
Optional Input Connector
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Earth Leakage Current
Power Factor
Input Protection
Standby Power
Consumption
General
•
•
•
•
•
•
•
•
90-264 VAC
47-63 Hz
0.4 A at 115 VAC
15 A/30 A for 115 VAC/230 VAC, cold start
0.75 mA at 240 VAC
Meets EN61000-3-2
Fitted with internal fuse
Typically 0.3 W, max 0.5 W
Output Voltage
Minimum Load
Hold Up Time
Start Up Delay
Transient Response
•
•
•
•
•
Line Regulation
Load Regulation
Ripple & Noise
Short Circuit Protection
Temperature
Coefficient
•
•
•
•
•
See tables
No minimum load required
5 ms min at full load 110 VAC
2.0 s at full load 100 VAC
2% deviation, recovery to within 1% of
nominal in 4 ms for 50% load change
See tables
See tables
1% pk-pk max, 20 MHz BW. See note 3.
Trip & restart (Hiccup mode), auto recovery
±0.04%/°C
Output
Efficiency
Isolation
Switching Frequency
MTBF
• 85% typical
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VDC Output to Ground
• 63 kHz typical
• 300 kHrs to MIL-STD-217F
Environmental
Operating Temperature • 0 °C to +70 °C, derate from 100% power
at +40 °C to 50% power at +70 °C
Storage Temperature
• -40 °C to +85 °C
Cooling
• Convection cooled
Operating Humidity
• 5-95% RH, non-condensing
Operating Altitude
• 3000 m
Shock
• 10 g, 10 ms on 3 axes
Vibration
• 5-100 Hz 2.31 m/s2, 20 mins 3 axes
EMC & Safety
Emissions
Harmonic Current
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
• EN55022 FCC Part-15C Level B
conducted & radiated
• EN61000-3-2 Class A
• EN61000-3-3
• EN61000-4-2 Level 3 Perf criteria A
• EN61000-4-3 3 V/m Perf criteria A
• EN61000-4-4 Level 2 Perf criteria A
• EN61000-4-5 Level 3 Perf criteria A
• EN61000-4-6 Level 2 Perf criteria A
• EN61000-4-8 1 A/m Perf criteria A
• EN61000-4-11, 70% UT for 500 ms,
40% UT for 100 ms, <5% UT for 5000 ms
Perf criteria A, B, B
• EN60950-1:2001, UL/cUL60950-1,
Approved as Limited Power Source,
CE Mark, China Compulsory Certification
(CCC) qualified.
Max Output
Power
Output
Voltage (4)
Output
Current
Total
Regulation(2)
Model
Number(1)
8W
3.3 VDC
2.50 A
7%
AEL15US03
12 W
5 VDC
2.40 A
7%
AEL15US05
8 VDC
1.87 A
5%
AEL15US08
9 VDC
1.66 A
5%
AEL15US09
12 VDC
1.25 A
5%
AEL15US12
15 VDC
1.00 A
5%
AEL15US15
18 VDC
0.83 A
5%
AEL15US18
24 VDC
0.62 A
5%
AEL15US24
30 VDC
0.50 A
5%
AEL15US30
36 VDC
0.42 A
3%
AEL15US36
48 VDC
0.31 A
3%
AEL15US48
15 W
Notes
1.
2.
3.
4.
Standard input connector is IEC320-C14 Inlet. For optional IEC320-C6 Inlet, add suffix “C6” to model number e.g. AEL15US12C6.
Total regulation includes initial set accuracy, line regulation, load regulation and temperature coefficient.
Measured at 25 ºC
Other output voltages available, contact sales for details.
Mechanical Details
1.42 ±0.04
(36.0 ±1.0)
1.50 ±0.04
(38.0 ±1.0)
3.58 ±0.04
(91.0 ±1.0)
AC INPUT
IEC-320-C6 INLET
AC INPUT
IEC-320-C14 INLET
Notes
1.
2.
3.
4.
5.
6.
7.
All dimensions are shown in inches (mm). Tolerance ±0.04 (±1.0) max.
Output connector: is 0.22 (5.5) outer diameter barrel, 0.10 (2.5) inner diameter barrel with centre positive (+) and outer shell negative (-). Length is 0.433 (11.0).
Output cable length is 48” (1220mm) approx.
Weight is 0.36 lbs (165 g)
For European mains lead order part: EU-MAINS-IEC or EU-MAINS-5 for C6 version.
For UK mains lead order part: UK-MAINS-IEC or UK-MAINS-5 for C6 version.
For US mains lead order part: US-MAINS-IEC or US-MAINS-5 for C6 version.
01-Dec-08
AC-DC
AEL15
Models and Ratings
AC-DC
20-60 Watts
xppower.com
AEL Series
•
CEC 2008 & EISA 2007 Compliant
•
Approved as LPS
•
China Compulsory Certfication (CCC) Qualified
•
Up to 88% Efficiency
•
+70 °C Operating Temperature
•
Compact Dimensions
•
20 W Optional Class II Insulation
Specification
Input
Input Voltage
Input Frequency
Input Current
• 90-264 VAC
• 47-63 Hz
• 0.4 A max AEL20
1.0 A max AEL40
1.6 A max AEL60
Inrush Current
• 15 A/30 A for 115 VAC/230 VAC, cold start
Earth Leakage Current • 0.75 mA at 240 VAC (except C2 version)
Power Factor
• Meets EN61000-3-2
Input Protection
• Fitted with internal fuse,
1 A AEL20, 2 A AEL40/60
Standby Power
• Typically 0.3 W, max 0.5 W
Consumption
Output
Output Voltage
Minimum Load
Hold Up Time
• See tables
• No minimum load required
• 12 ms min AEL20, 16 ms AEL40/60,
at full load 110 VAC
Start Up Delay
• 0.5 s AEL20/40, 2.0 s AEL60,
at full load 100 VAC
Transient Response
• 2% deviation, recovery to within 1% of
nominal in 500 µs for 50% load change
Line Regulation
• See tables
Load Regulation
• See tables
Ripple & Noise
• 1% pk-pk max, 20 MHz BW
Overvoltage Protection • 112-132%
Overload Protection
• 110-150%
Short Circuit Protection • Trip & restart (Hiccup mode), auto recovery
Temperature
• ±0.04%/°C
Coefficient
General
Efficiency
Isolation
Switching Frequency
MTBF
• 85% typical AEL20/40,
88% typical AEL60
• 3000 VAC Input to Output
1500 VAC Input to Ground (not C2 version)
500 VDC Output to Ground (not C2 version)
• 63 kHz typical
• 300 kHrs AEL20, 200 kHrs AEL40,
130 kHrs AEL60 to MIL-STD-217F
Environmental
Operating Temperature • 0 °C to +70 °C, derate from 100% power
at +40 °C to 50% power at +70 °C
Storage Temperature
• -40 °C to +85 °C
Cooling
• Convection cooled
Operating Humidity
• 5-95% RH, non-condensing
Operating Altitude
• 3000 m
Shock
• 10 g, 10 ms on 3 axes
Vibration
• 5-100 Hz 2.31 m/s2, 20 mins 3 axes
EMC & Safety
Emissions
Harmonic Current
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
• EN55022 FCC Part-15C Level B
conducted & radiated
• EN61000-3-2 Class A
• EN61000-3-3
• EN61000-4-2 Level 3 Perf criteria A
• EN61000-4-3 3 V/m Perf criteria A
• EN61000-4-4 Level 2 Perf criteria A
• EN61000-4-5 Level 3 Perf criteria A
• EN61000-4-6 Level 2 Perf criteria A
• EN61000-4-8 1 A/m Perf criteria A
• EN61000-4-11, 70% UT for 500 ms,
40% UT for 100 ms, <5% UT for 5000 ms
Perf criteria A, B, B
• EN60950-1:2001, UL/cUL60950-1,
Approved as Limited Power Source,
CE Mark, China Compulsory Certification
(CCC) qualified.
Max Output
Power
15 W
20 W
Output
Voltage(3)
Output
Current
Total
Regulation(2)
Model
Number(1)
5 VDC
3.00 A
5%
AEL20US05
12 VDC
1.67 A
4%
AEL20US12
15 VDC
1.33 A
4%
AEL20US15
24 VDC
0.83 A
3%
AEL20US24
30 VDC
0.67 A
3%
AEL20US30
48 VDC
0.42 A
3%
AEL20US48
Notes
1. For optional Class II version on AEL20 models only, add suffix ‘C2’ to model number e.g. AEL20US12C2.
2. Total regulation includes initial set accuracy, line regulation, load regulation and temperature coefficient.
3. Other output voltages available, contact sales for details.
Mechanical Details
0.02 (0.5)
0.04 (1.0)
1.22 (31.0)
1.65 (42.0)
3.90 (99.0)
AC INPUT
IEC-320-C6 INLET
AC INPUT
IEC-320-C8 INLET
(Optional C2 Version)
Notes
1.
2.
3.
4.
5.
6.
7.
All dimensions are shown in inches (mm). Tolerance ±0.04 (±1.0) max.
Output connector: is 0.22 (5.5) outer diameter barrel, 0.10 (2.5) inner diameter barrel with centre positive (+) and outer shell negative (-). Length is 0.433 (11.0).
Output cable length is 48” (1220mm) approx.
Weight is 0.37 lbs (170 g)
For European mains lead order part: EU-MAINS-C5 for AEL20, EU-MAINS-8 for AEL20 Class II.
For UK mains lead order part: UK-MAINS-5 for AEL20, UK-MAINS-8 for AEL20 Class II.
For US mains lead order part: US-MAINS-5 for AEL20, US-MAINS-8 for AEL20 Class II.
AC-DC
AEL20
Models and Ratings
Max Output
Power
25 W
35 W
40 W
Output
Voltage(2)
Output
Current
Total
Regulation(1)
Model
Number
5 VDC
5.00 A
7%
AEL40US05
8 VDC
4.37 A
5%
AEL40US08
9 VDC
3.88 A
5%
AEL40US09
12 VDC
3.33 A
5%
AEL40US12
15 VDC
2.67 A
5%
AEL40US15
18 VDC
2.22 A
5%
AEL40US18
24 VDC
1.67 A
3%
AEL40US24
36 VDC
1.11 A
3%
AEL40US36
48 VDC
0.83 A
3%
AEL40US48
Notes
1. Total regulation includes initial set accuracy, line regulation, load regulation and temperature coefficient.
2. Other output voltages available, contact sales for details.
Mechanical Details
0.04±0.004 (1.00±0.10)
0.04 (1.0)
1.36 (34.50)
4.65 (118.00)
0.02 (0.50)
2.05 (52.00)
AC-DC
AEL40
Models and Ratings
AC INPUT
IEC-320-C14 INLET
Notes
1.
2.
3.
4.
5.
6.
7.
All dimensions are shown in inches (mm). Tolerance ±0.04 (±1.0) max.
Output connector: is 0.22 (5.5) outer diameter barrel, 0.10 (2.5) inner diameter barrel with centre positive (+) and outer shell negative (-). Length is 0.433 (11.0).
Output cable length is 48” (1220mm) approx.
Weight is 0.70 lbs (300 g).
For European mains lead order part: EU-MAINS-IEC.
For UK mains lead order part: UK-MAINS-IEC.
For US mains lead order part: US-MAINS-IEC.
Max Output
Power
Output
Voltage(2)
Output
Current
Total
Regulation(1)
Model
Number
57 W
12 VDC
4.75 A
5%
AEL60US12
15 VDC
4.20 A
5%
AEL60US15
18 VDC
3.50 A
5%
AEL60US18
24 VDC
2.63 A
5%
AEL60US24
30 VDC
2.15 A
5%
AEL60US30
36 VDC
1.75 A
3%
AEL60US36
48 VDC
1.31 A
3%
AEL60US48
63 W
Notes
1. Total regulation includes initial set accuracy, line regulation, load regulation and temperature coefficient.
2. Other output voltages available, contact sales for details.
Mechanical Details
0.04±0.004 (1.00±0.10)
0.04 (1.0)
1.36 (34.50)
4.65 (118.00)
2.05 (52.00)
0.02 (0.50)
AC INPUT
IEC-320-C14 INLET
Notes
1.
2.
3.
4.
5.
6.
7.
All dimensions are shown in inches (mm). Tolerance ±0.04 (±1.0) max.
Output connector: is 0.22 (5.5) outer diameter barrel, 0.10 (2.5) inner diameter barrel with centre positive (+) and outer shell negative (-). Length is 0.433 (11.0).
Output cable length is 48” (1220mm) approx.
Weight 0.70 lbs (300 g).
For European mains lead order part: EU-MAINS-IEC.
For UK mains lead order part: UK-MAINS-IEC.
For US mains lead order part: US-MAINS-IEC.
01-Dec-08
AC-DC
AEL60
Models and Ratings
AC-DC
80 Watts
xppower.com
AEL80 Series
•
CEC 2008 & EISA 2007 Compliant
•
China Compulsory Certfication (CCC) Qualified
•
Output Voltages from 12 to 48 VDC
•
High Efficiency
•
+70 °C Operating Temperature
•
Compact Dimensions
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Earth Leakage Current
Power Factor
Input Protection
Standby Power
Consumption
General
•
•
•
•
•
•
•
•
90-264 VAC
47-63 Hz
1.1 A max
15 A/30 A for 115 VAC/230 VAC, cold start
0.75 mA at 240 VAC
Meets EN61000-3-2
Fitted with internal fuse
Typically 0.3 W, max 0.5 W
Output Voltage
Minimum Load
Hold Up Time
Start Up Delay
Transient Response
•
•
•
•
•
Line Regulation
Load Regulation
Ripple & Noise
Overvoltage Protection
Overload Protection
Short Circuit Protection
Temperature
Coefficient
•
•
•
•
•
•
•
See tables
No minimum load required
16 ms min at full load 110 VAC
2.0 s at full load 100 VAC
2% deviation, recovery to within 1% of
nominal in 500 µs for 50% load change
See tables
See tables
1% pk-pk max, 20 MHz BW
112-132%
110-150%
Trip & restart (Hiccup mode), auto recovery
±0.04%/°C
Output
Efficiency
Isolation
Switching Frequency
MTBF
• 85% minimum
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VDC Output to Ground
• 63 kHz typical
• 300 kHrs to MIL-STD-217F
Environmental
Operating Temperature • 0 °C to +70 °C, derate from 100% power
at +40 °C to 50% power at +70 °C
Storage Temperature
• -40 °C to +85 °C
Cooling
• Convection cooled
Operating Humidity
• 5-95% RH, non-condensing
Operating Altitude
• 3000 m
Shock
• 10 g, 10 ms on 3 axes
Vibration
• 5-100 Hz 2.31 m/s2, 20 mins 3 axes
EMC & Safety
Emissions
Harmonic Current
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
• EN55022 FCC Part-15C Level B
conducted & radiated
• EN61000-3-2 Class A
• EN61000-3-3
• EN61000-4-2 Level 3 Perf criteria A
• EN61000-4-3 3 V/m Perf criteria A
• EN61000-4-4 Level 2 Perf criteria A
• EN61000-4-5 Level 3 Perf criteria A
• EN61000-4-6 Level 2 Perf criteria A
• EN61000-4-8 1 A/m Perf criteria A
• EN61000-4-11, 70% UT for 500 ms,
40% UT for 100 ms, <5% UT for 5000 ms
Perf criteria A, B, B
• EN60950-1:2001, UL/cUL60950-1,
China Compulsory Certification (CCC)
qualified, CE Mark.
Max Output
Power
80 W
Output
Voltage(2)
Output
Current
Total
Regulation(1)
Model
Number
12 VDC
6.66 A
5%
AEL80US12
15 VDC
5.38 A
5%
AEL80US15
18 VDC
4.44 A
5%
AEL80US18
24 VDC
3.33 A
5%
AEL80US24
30 VDC
2.66 A
5%
AEL80US30
36 VDC
2.22 A
5%
AEL80US36
48 VDC
1.66 A
5%
AEL80US48
Notes
1. Total regulation includes initial set accuracy, line regulation, load regulation and temperature coefficient.
2. Other output voltages available, contact sales for details.
Mechanical Details
AC Input
IEC 320-C14 Inlet
1.69
(43.0)
2.99 (76.0)
5.75 (146.0) ±1.0
DC Output
3
5
2
1
4
DC Output
5 Pin Plug
Pin Connections
Pin
Function
1
RTN
2
RTN
3
+ve
4
RTN
5
+ve
Shell
GND
Notes
1.
2.
3.
4.
5.
6.
7.
All dimensions are shown in inches (mm). Tolerance ±0.04 (±1.0) max.
Output connector: 5 pin 180º DIN
Output cable length is 48” (1220mm) approx.
Weight is 1.5 lbs (700 g)
For European mains lead order part: EU-MAINS-IEC.
For UK mains lead order part: UK-MAINS-IEC.
For US mains lead order part: US-MAINS-IEC.
01-Dec-08
AC-DC
AEL80
Models and Ratings