Rohm BP5035A5 Non-isolated ac/dc converter Datasheet

Data Sheet
100VAC Input/−5VDC (200mA) Output
Non-Isolated AC/DC Converter
BP5035A5
Absolute Maximum Ratings
Unit
−170
200
2
−25 to +80
−25 to +80
V
mApk
kV
°C
°C
9.1MAX.
28.2MAX.
Mark Side
Limits
Vi
Io
Vsurge
Topr
Tstg
17.9MAX.
Symbol
1
4±1.0
Parameter
Input voltage
Output current
ESD endurance
Operating temperature range
Storage temperature range
Dimensions (Unit : mm)
3
5
7
10
0.25±0.05
0.5±0.1
1.3±0.2
P=5.08±0.2
3.25MAX
4.25MAX.
4.85MAX.
2.54�9=22.86
Electrical Characteristics
Typ.
−141
−5.0
−
0.04
0.05
0.07
60
Max.
−170
−5.3
200
0.15
0.15
0.15
−
Unit
V
V
mA
V
V
Vp-p
%
Conditions
DC (80 to 120VAC)
Vi=−141V, Io=100mA
Vi=−141V
∗1
Vi=−113 to −170V, Io=100mA
Vi=−141V, Io=0 to 100mA
Vi=−141V, Io=100mA
∗2
Vi=−141V, Io=200mA
Derating Curve
250
200
150
0
-30 -20 -10 0 10 20 30 40 50 60 70 80 90
Ambient Temperature Ta(°C)
−
220V
+
C1
22µF/200V
5
3
1
FUSE
1A
C2
0.1µF
L1
470µH
Output
−5V
−
+
C3
Be sure to use fuse for safety.
External Component Specifications
C2: Noise reduction
capacitor
C3: Output smoothing
capacitor
D1: Rectifier diode
L1: Power inductor
R1: Noise reduction
resistor
ZNR: Varistor
5
4
3
2
1
0
0
50 100 150 200 250
Output Current Io(mA)
300
100µF/50V
Please verify operation and characteristics in the customer's circuit before actual usage.
Ensure that the load current does not exceed the maximum rating.
FUSE: Fuse
C1: Input smoothing
capacitor
Load Regulation
(Ta=25°C, Vi=−141V)
6
Use a fuse of 1A
Capacitance : 22µF
Ripple current is 0.13Arms or above.
Rated voltage : 200V or higher
Capacitance : 0.1 to 0.22µF
Rated voltage : 200V or higher
Use a film or ceramic capacitor. Evaluate under actual operating
conditions.
Capacitance : 100 to 470µF
Rated voltage : 16V or higher, low impedance
Impedance is 0.4Ω max at high frequencies.
Ripple current 0.25Arms or above.
Capacitor impedance affects the output ripple voltage.
In the absolute maximum ratings, the reverse surge voltage should be
400V or higher, the average rectifying current should be 0.5A or higher,
and the forward surge current should be 20A or higher.
Inductance : 470µH, Rating current : above 0.57A
Select components that do not easily become magnetically saturated
at high temperatures.
Conversion Efficiency
Conversion Efficiency (%)
R1
D1
1SR139−400A 10Ω1/4W
7
Function
Output terminal Vo (−5V)
Skipping Pin
Coil connect
Skipping Pin
Coil connect
Skipping Pin
COMMON
Skipping Pin
Skipping Pin
Input terminal Vi (−141VDC)
70
Conversion Efficiency
(Ta=25°C, Vi=141V)
60
50
40
30
20
10
0
0 20 40 60 80 100 120 140 160 180 200
Output Current Io(mA)
Surface Temperature Increase
Temperature Rising ∆T(°C)
10
Pin No.
1
2
3
4
5
6
7
8
9
10
Output Voltage −Vo(V)
Please note that pin No.10
side is input.
ZNR
50
Load Regulation
BP5035A5
Input
AC100V
50Hz/60Hz
Operation Range
100
∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve.
∗2 Spike noise is not included in output ripple voltage.
Application Circuit
Derating Curve
300
Output Current Io(mA)
Symbol Min.
Parameter
Input voltage range
−113
Vi
Output voltage
−4.7
Vo
Output current
0
Io
Line regulation
−
Vr
Load regulation
−
Vl
Output ripple voltage
−
Vp
Power conversion efficiency
50
η
Surface Temperature Increase
(Ta=25°C, Vi=141V)
60
50
40
30
20
10
0
0
50
100
150
Output Current Io(mA)
200
10 to 22Ω, 1/4W
Determine the ideal value through actual testing.
A varistor is required to protect against lightning surges and static
electricity.
www.rohm.com
©2010 ROHM Co., Ltd. All rights reserved.
1/1
2010.01 - Rev.A
Notice
Notes
No copying or reproduction of this document, in part or in whole, is permitted without the
consent of ROHM Co.,Ltd.
The content specified herein is subject to change for improvement without notice.
The content specified herein is for the purpose of introducing ROHM's products (hereinafter
"Products"). If you wish to use any such Product, please be sure to refer to the specifications,
which can be obtained from ROHM upon request.
Examples of application circuits, circuit constants and any other information contained herein
illustrate the standard usage and operations of the Products. The peripheral conditions must
be taken into account when designing circuits for mass production.
Great care was taken in ensuring the accuracy of the information specified in this document.
However, should you incur any damage arising from any inaccuracy or misprint of such
information, ROHM shall bear no responsibility for such damage.
The technical information specified herein is intended only to show the typical functions of and
examples of application circuits for the Products. ROHM does not grant you, explicitly or
implicitly, any license to use or exercise intellectual property or other rights held by ROHM and
other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the
use of such technical information.
The Products specified in this document are intended to be used with general-use electronic
equipment or devices (such as audio visual equipment, office-automation equipment, communication devices, electronic appliances and amusement devices).
The Products specified in this document are not designed to be radiation tolerant.
While ROHM always makes efforts to enhance the quality and reliability of its Products, a
Product may fail or malfunction for a variety of reasons.
Please be sure to implement in your equipment using the Products safety measures to guard
against the possibility of physical injury, fire or any other damage caused in the event of the
failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM
shall bear no responsibility whatsoever for your use of any Product outside of the prescribed
scope or not in accordance with the instruction manual.
The Products are not designed or manufactured to be used with any equipment, device or
system which requires an extremely high level of reliability the failure or malfunction of which
may result in a direct threat to human life or create a risk of human injury (such as a medical
instrument, transportation equipment, aerospace machinery, nuclear-reactor controller, fuelcontroller or other safety device). ROHM shall bear no responsibility in any way for use of any
of the Products for the above special purposes. If a Product is intended to be used for any
such special purpose, please contact a ROHM sales representative before purchasing.
If you intend to export or ship overseas any Product or technology specified herein that may
be controlled under the Foreign Exchange and the Foreign Trade Law, you will be required to
obtain a license or permit under the Law.
Thank you for your accessing to ROHM product informations.
More detail product informations and catalogs are available, please contact us.
ROHM Customer Support System
http://www.rohm.com/contact/
www.rohm.com
© 2010 ROHM Co., Ltd. All rights reserved.
R1010A