FAB0307021 FEATURES Liquid cooled converter 360 x 310 x 205 mm INPUT : 56-100Vdc OUTPUT : 120-240Vdc 10KW Efficiency : 84 % typ. APPLICATIONS DC/DC liquid cooled converter for automotive application with output current control. INPUT Voltage range : 56-100Vdc Input current max. : 100A, internal power limitation Undervoltage turn-on : 54,3V Undervoltage turn-off : 45,8V Input protection : transient and surges protected EMI filter OUTPUT Voltage : 120 to 240Vdc with external control Current : 0 to 42A with external control OUTPUT Line regulation Max. 0,02 % 0,2 % Low line to high line ; full load 0,2 % No load to full load Load regulation Ripple and noise Current limit Short circuit current Conditions Typ. 0,5 % 1% 115 % of I nominal Peak to peak, nom. Input ; full load Vout = 95% of nominal ; Automatic restart 115 % of Iout nominal Vout < 250mV ; Automatic restart 1/3 FAB0307021 SIGNALS Monitoring : Input voltage with 4-20mA isolated signal Output voltage with 4-20mA isolated signal Input current with 4-20mA isolated signal Output current with 4-20mA isolated signal Power Good : Isolated by open collector Inhibit : Isolated, put low to inhibit Programming : Control of the output current by an external PWM signal from 10 to 100 % Overtemperature : Isolated by open collector PROTECTION Output : Overvoltage protected : reset input voltage to restart Overtemperature protection : 90°C typ. by thermostat ; Automatic restart ENVIRONMENTAL Storage temperature : -40°C to +100°C Operating temperature : -40°C to +60°C, liquid cooled ISOLATION Input to chassis : 1500Vdc Output to Chassis : 1500Vdc 2/3 FAB0307021 MECHANICALS Liquid cooled OUTPUT INPUT SIGNAL : SOURIAU family 851 3/3