PST FAB0307021 Dc/dc liquid cooled converter for automotive application with output current control Datasheet

FAB0307021
FEATURES
Liquid cooled converter
360 x 310 x 205 mm
INPUT : 56-100Vdc
OUTPUT : 120-240Vdc
10KW
Efficiency : 84 % typ.
APPLICATIONS
DC/DC liquid cooled converter for automotive application with output current control.
INPUT
Voltage range :
56-100Vdc
Input current max. :
100A, internal power limitation
Undervoltage turn-on :
54,3V
Undervoltage turn-off :
45,8V
Input protection :
transient and surges protected
EMI filter
OUTPUT
Voltage :
120 to 240Vdc with external control
Current :
0 to 42A with external control
OUTPUT
Line regulation
Max.
0,02 %
0,2 %
Low line to high line ; full load
0,2 %
No load to full load
Load regulation
Ripple and noise
Current limit
Short circuit current
Conditions
Typ.
0,5 %
1%
115 %
of I nominal
Peak to peak, nom. Input ; full load
Vout = 95% of nominal ;
Automatic restart
115 %
of Iout nominal
Vout < 250mV ; Automatic restart
1/3
FAB0307021
SIGNALS
Monitoring :
Input voltage with 4-20mA isolated signal
Output voltage with 4-20mA isolated signal
Input current with 4-20mA isolated signal
Output current with 4-20mA isolated signal
Power Good :
Isolated by open collector
Inhibit :
Isolated, put low to inhibit
Programming :
Control of the output current by an external PWM signal from 10 to 100 %
Overtemperature :
Isolated by open collector
PROTECTION
Output :
Overvoltage protected :
reset input voltage to restart
Overtemperature protection : 90°C typ. by thermostat ; Automatic restart
ENVIRONMENTAL
Storage temperature :
-40°C to +100°C
Operating temperature :
-40°C to +60°C, liquid cooled
ISOLATION
Input to chassis :
1500Vdc
Output to Chassis :
1500Vdc
2/3
FAB0307021
MECHANICALS
Liquid cooled
OUTPUT
INPUT
SIGNAL : SOURIAU family 851
3/3