The TOSHIBA TLP197A consists of an aluminum gallium arsenide
infrared emitting diode optically coupled to a photo-MOS FET in a SOP,
which is suitable for surface mount assembly.
The TLP197A is suitable for replacement of mechanical relays in many
applications which require space savings.
FEATURES
·
6 pin SOP (2.54SOP6)
·
1-Form-A
: 2.1 mm high, 2.54 mm pitch
·
Peak Off-State Voltage
: 60 V (MIN.)
·
Trigger LED Current
: 3 mA (MAX.)
·
On-State Current
: 400 mA (MAX.)
·
On-State Resistance
: 2 W (MAX.)
·
Isolation Voltage
: 1500 Vrms (MIN.)
·
UL Recognized
: UL1577, File No. E67349
JEDEC
EIAJ
TOSHIBA
Weight: 0.13 g
11-7C1
PIN CONFIGURATION (TOL VIEW)
1
6
2
5
3
4
1 : ANODE
2 : CATHODE
3 : N.C.
4 : DRAIN D1
5 : SOURCE
6 : DRAIN D2
SCHEMATIC
1
6
2
5
4
2000-08-09
1/6
TLP197A
MAXIMUM RATINGS (Ta = 25°C)
CHARACTERISTIC
SYMBOL
RATING
UNIT
IF
50
mA
DIF/°C
-0.5
mA/°C
Peak Forward Current (100 ms pulse, 100 pps)
IFP
1
A
Reverse Voltage
VR
5
V
Junction Temperature
Tj
125
°C
VOFF
60
V
Forward Current
LED
Forward Current Derating (Ta >
= 25°C)
Off-State Output Terminal Voltage
DETECTOR
A Connection
On-State RMS Current
400
ION
B Connection
C Connection
800
A Connection
-4.0
On-State Current Derating
DION/°C
B Connection
(Ta >
= 25°C)
mA
400
-4.0
mA/°C
-8.0
C Connection
Junction Temperature
Tj
125
°C
Operating Temperature Range
Topr
-40~85
°C
Storage Temperature Range
Tstg
-55~125
°C
Lead Soldering Temperature (10 s)
Tsol
260
°C
Isolation Voltage (AC, 1 minute, R.H. <
= 60%) (NOTE1)
BVS
1500
Vrms
(NOTE1) :Device considered a two-terminal device : Pins 1, 2 and 3 shorted together, and pins 4, 5 and 6
shorted together.
RECOMMENDED OPERATING CONDITIONS
CHARACTERISTIC
SYMBOL
MIN.
TYP.
MAX.
UNIT
Supply Voltage
VDD
¾
¾
48
V
Forward Current
IF
5
7.5
25
mA
On-State Current
ION
¾
¾
300
mA
Operating Temperature
Topr
-20
¾
65
°C
CIRCUIT CONNECTIONS
1
6
LOAD
1
6
2
5
AC
or
DC
2
5
3
4
A Connection
3
LOAD
4
B Connection
DC
1
6
2
5
LOAD
DC
3
4
C Connection
2000-08-09
2/6
TLP197A
INDIVIDUAL ELECTRICAL CHARACTERISTICS (Ta = 25°C)
DETECTOR
LED
CHARACTERISTIC
SYMBOL
TEST CONDITION
MIN.
TYP.
MAX.
UNIT
Forward Voltage
VF
IF = 10 mA
1.0
1.15
1.3
V
Reverse Current
IR
VR = 5 V
¾
¾
10
mA
Capacitance
CT
V = 0, f = 1 MHz
¾
30
¾
pF
Off-State Current
IOFF
VOFF = 60 V
¾
¾
1
mA
Capacitance
COFF
V = 0, f = 1 MHz
¾
130
¾
pF
MIN.
TYP.
MAX.
UNIT
COUPLED ELECTRICAL CHARACTERISTICS (Ta = 25°C)
CHARACTERISTIC
SYMBOL
TEST CONDITION
Trigger LED Current
IFT
ION = 400 mA
¾
¾
3
mA
Close LED Current
IFC
IOFF = 100 mA
0.1
¾
¾
mA
ION = 400 mA, IF = 5 mA
¾
1
2
ION = 400 mA, IF = 5 mA
¾
0.5
1
ION = 800 mA, IF = 5 mA
¾
0.25
¾
MIN.
TYP.
MAX.
UNIT
¾
0.8
¾
pF
¾
W
A Connection
On-State
Resistance
RON
B Connection
C Connection
W
ISOLATION CHARACTERISTICS (Ta = 25°C)
CHARACTERISTIC
SYMBOL
Capacitance Input to Output
Isolation Resistance
TEST CONDITION
CS
VS = 0 V, f = 1 MHz
RS
VS = 500 V, R.H. <
= 60%
10
5 ´ 10
BVS
10
1500
¾
¾
AC, 1 second (in oil)
¾
3000
¾
DC, 1 minute (in oil)
¾
3000
¾
Vdc
MIN.
TYP.
MAX.
UNIT
¾
0.6
2
¾
0.1
1
AC, 1 minute
Isolation Voltage
14
Vrms
SWITCHING CHARACTERISTICS (Ta = 25°C)
CHARACTERISTIC
SYMBOL
Turn-on Time
tON
Turn-off Time
tOFF
TEST CONDITION
RL = 200 W
VDD = 20 V, IF = 5 mA
(NOTE 2)
ms
(NOTE 2) : SWITCHING TIME TEST CIRCUIT
IF
1
6
RL
VDD
IF
2
VOUT
VOUT
4
90%
10%
tON
tOFF
2000-08-09
3/6
TLP197A
IF - Ta
ION - Ta
1200
ON-STATE CURRENT ION (mA)
ALLOWABLE FORWARD CURRENT
IF (mA)
100
1000
80
60
40
20
0
-20
200
0
20 40 60 80 100 120
AMBIENT TEMPERATURE Ta(℃)
- VF
ION - V ON
750
50
30
ON-STATE CURRENT ION(mA)
FORWARD CURRENT IF (mA)
A,B CONNECTION
400
0
-20
100
10
5
3
1
0.5
0.3
0.1
0.6
600
0
20 40 60 80 100 120
AMBIENT TEMPERATURE Ta(℃)
IF
C CONNECTION
800
0.8
1
1.2 1.4 1.6
FORWARD VOLTAGE V(V)
F
Ta=25℃,IF =5mA
A CONNECTION
500
250
0
-250
-500
-750
-1
1.8
-0.5
0
0.5
ON-STATE VOLTAGE VON(V)
IFT
5
TRIGGER LED CURRENT IFT(mA)
ON-STATE RESISTANCE R ON(Ω)
RON - Ta
2
ION =400mA
IF =5mA
1.5
1
0.5
0
-20
0
20
40
60
80
AMBIENT TEMPERATURE Ta(℃)
100
1
- Ta
ION =400mA
t<1s
4
3
2
1
0
-40
-20 0
20 40 60 80
AMBIENT TEMPERATURE Ta(℃)
100
2000-08-09
4/6
TLP197A
tON
1000
tON,tOFF
- IF
Ta=25℃
VDD=20V, RL=200Ω
500
300
tOFF
100
50
30
1
30 50 100
3 5 10
FORWARD CURRENT IF (mA)
SWITCHING TIME tON,tOFF(μs)
SWITCHING TIME tON,tOFF(μs)
tON,tOFF
2000
1000
- Ta
VDD=20V, R L=200Ω
IF =5mA
800
tON
600
400
200
0
-40
tOFF
-20 0
20 40 60 80
AMBIENT TEMPERATURE Ta(℃)
100
IOFF - Ta
OFF-STATE CURRENT IOFF (nA)
100
V OFF
=60V
10
1
0.1
-20
0
20
40
60
80
AMBIENT TEMPERATURE Ta(℃)
100
2000-08-09
5/6
TLP197A
RESTRICTIONS ON PRODUCT USE
000707EBC
· TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor
devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical
stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of
safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of
such TOSHIBA products could cause loss of human life, bodily injury or damage to property.
In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as
set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and
conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability
Handbook” etc..
· The TOSHIBA products listed in this document are intended for usage in general electronics applications
(computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances,
etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires
extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or
bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or
spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments,
medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this
document shall be made at the customer’s own risk.
· Gallium arsenide (GaAs) is a substance used in the products described in this document. GaAs dust and fumes
are toxic. Do not break, cut or pulverize the product, or use chemicals to dissolve them. When disposing of the
products, follow the appropriate regulations. Do not dispose of the products with other industrial waste or with
domestic garbage.
· The products described in this document are subject to the foreign exchange and foreign trade laws.
· The information contained herein is presented only as a guide for the applications of our products. No
responsibility is assumed by TOSHIBA CORPORATION for any infringements of intellectual property or other
rights of the third parties which may result from its use. No license is granted by implication or otherwise under
any intellectual property or other rights of TOSHIBA CORPORATION or others.
· The information contained herein is subject to change without notice.
2000-08-09
6/6