Click on Series name for product info on aimtec.com Series AMEL10-MAZ 10 Watt | AC-DC / DC-DC Converter FEATURES: I/O Isolation 4000VAC Operating Temp: -40oC to +70oC Over load, Over Voltage, Short Circuit Protection Up to 80% efficiency Energy Star compliant Ultra small package Models Single output Model CB Input Voltage (VAC/Hz) Input Voltage (VDC) Max Output wattage (W) Output Voltage (V) Output Current max (A) Maximum capacitive load (µF) Efficiency (%) AMEL10-3.3SMAZ 90-264/47-440 130-370 9.9 3.3 3.00 2200 AMEL10-5SMAZ 90-264/47-440 130-370 10 5 2.00 1000 AMEL10-12SMAZ 90-264/47-440 130-370 10 12 0.84 680 AMEL10-15SMAZ 90-264/47-440 130-370 10 15 0.67 470 AMEL10-24SMAZ 90-264/47-440 130-370 10 24 0.42 470 Note: Optional mounting plate version can be ordered by adding “-ST” suffix to part number (ex. AMEL10-5SMAZ-ST) 75 77 79 80 80 Models Asymmetric Dual output Model AMEL10-3.35DMAZ AMEL10-3.312DMAZ AMEL10-3.315DMAZ AMEL10-3.324DMAZ AMEL10-512DMAZ AMEL10-515DMAZ AMEL10-524DMAZ AMEL10-1215DMAZ AMEL10-1224DMAZ AMEL10-1524DMAZ Input Voltage (VAC/Hz) Input Voltage (VDC) 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 130-370 130-370 130-370 130-370 130-370 130-370 130-370 130-370 130-370 130-370 (W) Output Voltage (V) Rated Output Current (A) Maximum capacitive load (µF) Efficiency (%) 7.9 8 8 8 8 8 8 8 9 9 3.3/5 3.3/12 3.3/15 3.3/24 5/12 5/15 5/24 12/15 12/24 15/24 0.9/1.0 0.9/0.41 0.9/0.33 0.9/0.2 0.6/0.41 0.6/0.33 0.6/0.2 0.25/0.33 0.25/0.25 0.2/0.25 680 680 680 680 470 470 470 330 330 330 74 77 76 75 75 77 72 76 78 79 Max Output wattage AMEL10-3.3N5DMAZ 90-264/47-440 130-370 7.3 -3.3/5 -0.7/1.0 680 AMEL10-3.3N12DMAZ 90-264/47-440 130-370 8 -3.3/12 -0.9/0.41 680 AMEL10-3.3N15DMAZ 90-264/47-440 130-370 8 -3.3/15 -0.9/0.33 680 AMEL10-5N5DMAZ 90-264/47-440 130-370 8 -5/5 -0.6/1 680 AMEL10-5N12DMAZ 90-264/47-440 130-370 8 -5/12 -0.6/0.41 470 AMEL10-5N15DMAZ 90-264/47-440 130-370 8 -5/15 -0.6/0.33 470 AMEL10-12N12DMAZ 90-264/47-440 130-370 8 -12/12 -0.25/0.41 470 AMEL10-12N15DMAZ 90-264/47-440 130-370 8 -12/15 -0.25/0.33 330 Note: Optional mounting plate version can be ordered by adding “-ST” suffix to part number (ex. AMEL10-5SMAZ-ST) 74 75 75 74 74 74 76 75 *Output power must not exceed the listed values. All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Current Inrush current <2ms (cold start) Leakage current External fuse www.aimtec.com F 052e R8.U Conditions Typical 115VAC 230VAC 115VAC 230VAC 0.23 0.15 1 slow blow type Tel: +1 514 620 2722 1 of 6 Maximum 10 20 0.25 Units A A A A mA A Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEL10-MAZ 10 Watt | AC-DC / DC-DC Converter Input Specifications (continued) Parameters Input dissipation Start up time Conditions Typical No Load ≤0.2 50 Conditions Typical Maximum Units W ms Output Specifications Parameters Voltage accuracy Line regulation Load regulation (single output) Load regulation (dual output) Transient recovery time Transient response deviation 0-100% load Unbalanced (0-100% load) 25% load step 3.3 & 5V models 12, 15 & 24V models 115VAC 230VAC Ripple & Noise* Hold-up time (min) Maximum ±2 ±1 ±2 ±3 500 ±2 75 100 10 25 Units % % % % µs % of Vout mV p-p ms *Ripple and Noise are measured at 20MHz bandwidth by using a 0.1µF (M/C) & 4.7µF (E/C) parallel capacitor. Isolation Specifications Parameters Conditions Tested I/O voltage Isolation resistance Isolation capacitor Typical 60 sec, 1.2mA Rated Units 4000 VAC MΩ pF >1000 2200 General Specifications Parameters Switching frequency Protection class Over load protection Over voltage protection Short circuit protection Short circuit restart Operating temperature Maximum case temperature Storage temperature Temperature coefficient Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Conditions Typical 100% load Maximum 65 Class II 150 Zener Diode Clamp Continuous Auto recovery -40 to +70 Auto recovery, Foldback See derating table Units KHz % oC 100 -45 to +95 ±0.02 Free air convection Non condensing 20 ~ 95 Plastic resin + Fiberglass (flammability to UL 94V-0) 70 2.22 x 1.21 x 0.99 inches 56.48 x 30.86 x 25.10mm > 400 000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load > 100,000 hrs (MIL-HDBK -217F, t=at highest operating temperature)/Full Load oC oC % / oC % RH g Environment Approval Test Shock Vibration Parameters Wave form Acceleration amplitude Bump duration Converter operation Number of bumps Test mode Displacement Acceleration Converter operation www.aimtec.com F 052e R8.U Conditions Half sine wave 5gn 30 ms before and after test, body mounted (on chassis) 18 (3 in each direction for every axis) Sweep sine 1mm 3g 10-100Hz, speed 0.05Hz/s Tel: +1 514 620 2722 2 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEL10-MAZ 10 Watt | AC-DC / DC-DC Converter Safety Specifications Parameters Agency approvals cULus, CE, CB Medical Electrical Equipment Information technology Equipment EMI - Conducted and radiated emission Harmonic Current Emissions Voltage fluctuations and flicker Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Electrical Fast Transient/Burst Immunity Surge Immunity RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Voltage dips, Short Interruptions Immunity Information Technology Equipment Information Technology Equipment Standards IEC\EN\UL 60601-1, 2 x MOOP, CSA-C22.2 No. 601.1-M90 EN 60950-1:2006+A11:2009 EN55022, class B IEC/EN 61000-3-2, Class A IEC/EN 61000-3-3, (EN60555-3) IEC 61000-4-2 Level 3 IEC 61000-4-3 Level 2 IEC 61000-4-4 Level 2 IEC 61000-4-5 Level 3 IEC 61000-4-6 Level 2 IEC 61000-4-8 IEC 61000-4-11 UL 60950-1:2007 CAN/CSA-C22.2 No.60950-1-07 Additional Surge Protective Circuitry The AMEL10-MAZ series design level surge protection is certified to IEC 61000-4-5 surge Line to Line of 1KV. However greater protection can be enhanced by adding protective devices to ingress circuitry. For example, by adding an MOV (Metal Oxide Varistor) device example TVR10471KSY to the N / L input lines 2KV surge protection or greater, can be achieved. MOV PN Vrms V Vdc V Wmax (2ms) J Pmax W TVR10471KSY 300 385 70 0.4 Pin Out Specifications Pin Single Dual positive Dual negative/positive 1 2 3 4 5 AC Input (N) AC Input (L) +V Output -V Output No pin AC Input (N) AC Input (L) +V1 Output Common +V2 Output AC Input (N) AC Input (L) +V1 Output Common -V2 Output www.aimtec.com F 052e R8.U Tel: +1 514 620 2722 3 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEL10-MAZ 10 Watt | AC-DC / DC-DC Converter Dimensions 56.46 (2.22) 45.72 (1.80) 3 1 4 3 1 4 2 5 5.37 (0.21) 2 5.37 (0.21) 5 DIV: 10.00 (0.40) 5Ø 1.0 (Ø 0.04) Dimensions mm (inch) Case Tolerance ±0.50 (±0.02) Pin Diameter 1.0 ± 0.05 (0.04 ± 0.002) Pin Pitch Tolerance ±0.35 (±0.014) 1.05 (0.04) Derating Free Air Convection 50°C Output Power (%) 100 80 60 Safe Operating Area 40 20 70°C 0 - 40 - 20 0 20 40 60 80 100 Ambient Temperature º C www.aimtec.com F 052e R8.U Tel: +1 514 620 2722 4 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEL10-MAZ 10 Watt | AC-DC / DC-DC Converter Derating (Dual Output Models) Free Air Convection 40°C Output Power (%) 100 80 60 Safe Operating Area 40 20 70°C 0 - 40 - 20 0 20 40 60 80 100 Ambient Temperature º C www.aimtec.com F 052e R8.U Tel: +1 514 620 2722 5 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEL10-MAZ 10 Watt | AC-DC / DC-DC Converter Dimensions of Optional ST Mounting Plate Version 38.00 25.00 Pin Out Specification ST Version NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052e R8.U Tel: +1 514 620 2722 6 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only