TORX173 FIBER OPTIC RECEIVING MODULE TORX173 FIBER OPTIC RECEIVING MODULE FOR DIGITAL AUDIO EQUIPMENT Unit: mm l Conform to JEITA Standard CP−1201 (For Digital Audio Interfaces including Fiber Optic inter−connections). l TTL Interface l ATC (Automatic Threshold Control) Circuit is used for stabilized output at a wide range of optical power level. 1. Maximum Ratings (Ta = 25°C) Characteristics Symbol Rating Unit Storage Temperature Tstg −40 to 70 °C Operating Temperature Topr −20 to 70 °C Supply Voltage VCC −0.5 to 7 V Low Level Output Current IOL 20 mA High Level Output Current IOH −1 mA Soldering Temperature Tsol 260 (Note 1) °C Note 1: Soldering time ≤ 10 s (More than 1 mm apart from the package). 2. Recommended Operating Conditions Characteristics Symbol Min Typ. Supply Voltage VCC 4.75 5.0 5.25 V High Level Output Current IOH ― ― −150 µA Low Level Output Current IOL ― ― 1.6 mA 1 Max Unit 2001-08-10 TORX173 3. Electrical and Optical Characteristics (Ta = 25°C, VCC = 5 V) Characteristics Symbol Test Condition Data Rate NRZ code (Note 2) Transmission Distance TOTX173 Using APF (Note 3) Pulse width 165 ns Pulse cycle 330 ns, CL = 10 pF Using TOTX173 Min Typ. Max Unit DC ― 6 Mb / s 0.2 ― 10 m −20 ― 20 ns Pulse Width Distortion (Note 4) ∆tw Maximum Receivable Power (Note 5) PMAX 6 Mb / s, Using APF −14.5 ― ― dBm Minimum Receivable Power (Note 5) PMIN 6 Mb / s, Using APF ― ― −27 dBm Rise Time tr CL = 10 pF ― 10 30 ns Fall Time tf CL = 10 pF ― 5 30 ns Current Consumption ICC ― 22 40 mA High Level Output Voltage VOH 2.7 ― ― V Low Level Output Voltage VOL ― ― 0.4 V Note 2: For data rate > 3 Mb / s, the duty factor must be such as kept 25 to 75%. High level output when optical flux is received. Low level output when optical flux is not received. Note 3: All Plastic Fiber (970 / 1000 µm). Note 4: Between input of a fiber optic transmitting module and output of TORX173. −9 Note 5: BER ≤ 10 , rated by peak value. 2 2001-08-10 TORX173 4. Example of Typical Characteristics (Note 6) Note 6: There give characteristic examples, and its values are not guaranteed. 3 2001-08-10 TORX173 5. Application Circuit 6. Applicable optical fiber with fiber optic connectors. TOCP172−□□B 4 2001-08-10 TORX173 7. Precautions during use (1) (2) (3) (4) (5) (6) (7) (8) Maximum rating The maximum ratings are the limit values which must not be exceeded when using the device. Any one of the rating must not be exceeded. If The maximum rating is exceeded, the characteristics may not be recovered. In some extreme cases, the device may be permanently damage. Soldering Optical modules use semiconductor devices internally. However, in principle, optical modules are optical components. At soldering, take care that flux dose not contact the emitting surface or detecting surface. Also take care at flux removal after soldering. Some optical modules come with protective cap. The protective cap is used to avoid malfunction when the optical module is not in use. Not that it is not dust or waterproof. As mentioned before, optical modules are optical component. Thus, in principle, soldering where there may be flux residue or flux removal after soldering is not recommended. Toshiba recommends that soldering be performed without the optical module mounted on the board. Then, after the board is cleaned, solder the optical module manually. Do not perform any further cleaning. If the optical module cannot be soldered manually, use non−halogen (chlorine−free) flux and make sure, without cleaning, there is no residue such as chlorine. This is one of the ways to eliminate the effects of flux. In such a case, check the reliability. Noise resistance Where the fiber optic receiving module case uses conductive resin, shield by connecting the reinforcing pin at a front end of the module to GND. When using this optical module, connect the pin to SIGNAL−GND. Where the fiber optic receiving module case has a resistance of several tens of ohms, take care that the case does not contact power line of other circuits. It is believed that the use of optical transfer devices improve the noise resistance. In principle, optical fiber is not affected by noise. However, especially receiving module which handle signals whose level is extremely small, are comparatively more susceptible to noise. TOSLINK improves noise resistance using a conductive case. However, the current of the signal output from the photodiode of the optic receiving module is extremely small. Thus, depending on the usage environment, shielding the case is not sufficient for noise resistance. When using TOSLINK, Toshiba recommends that you test using the actual device and check the noise resistance. Use a simple noise filter on the TOSLINK fiber optic receiving module power line. If the ripple in power supply used is high, further reinforce the filter. When locating the optical module in an area susceptible to radiated noise, increase shielding by covering the optical module and the power line filter using a metallic cover. Vibration and shock This module is resin−molded construction with wire fixed by resin. This structure is relatively sound against vibration or shock, In actual equipment, there are some cases where vibration, shock, and stress is applied to soldered parts or connected parts, resultingin line cut. Attention must be paid to the design of the mechanism for applications which are subject to large amounts of vibration. Fixing fiber optical receiving module Solder the fixed pin (pins 5 and 6) of fiber optic receiving module TORX173 to the printed circuit board to fix the module to the board. Shielding and wiring pattern of fiber optic receiving modules To shield, connect the fixed pins (pins 5 and 6) of fiber optic transceiving module TORX173 to the GND. Where the fiber optic receiving module uses conductive resin, be careful that the case does not touch wiring (including land). To improve noise resistance, shield the optical module and the power line filter using a metallic cover. Solvent When using solvent for flux removal, do not use a high acid or high alkali solvent. Be careful not to pour solvent in the optical connector ports. If solvent is inadvertently poured there, clean with cotton tips. Protective cap When the fiber optic receiving module TORX173 is not in use, use the protective cap. 5 2001-08-10 TORX173 (9) (10) (11) (12) (13) (14) Supply voltage Use the supply voltage within the Typ. operating condition (VCC = 5 ± 0.25 V). Make sure that supply voltage does not exceed the maximum rating value of 7 V, even instantaneously. Interface TORX173 has a TTL interface. It can be interfaced with C−MOS IC that has compatibility with TTL level. Output When the receiver output is at low level and connected to the power supply, or when the output is at high level and connected to GND, the internal IC may be destroyed. Soldering condition Solder at 260°C or less within ten seconds. Precaution on waste When discarding devices and packing materials, follow procedures stipulated by local regulations in order to protect the environment against contamination. Precaution on use Toshiba is continually working to improve the quality and the reliability of its products. Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer, when utilizing Toshiba products, to observe standards of safety, and to avoid situations in which a malfunction or failure of a Toshiba product could cause loss of human life, bodily injury or damage to property. In developing your designs, please ensure that Toshiba products are used within specified operating ranges as set forth in the most recent product specifications. Also, please keep in mind the precautions and conditions set forth in the Toshiba Semiconductor Reliability Handbook. 6 2001-08-10 TORX173 RESTRICTIONS ON PRODUCT USE 000707EAA · TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of such TOSHIBA products could cause loss of human life, bodily injury or damage to property. In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability Handbook” etc.. · The TOSHIBA products listed in this document are intended for usage in general electronics applications (computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this document shall be made at the customer’s own risk. · The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by TOSHIBA CORPORATION for any infringements of intellectual property or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any intellectual property or other rights of TOSHIBA CORPORATION or others. · The information contained herein is subject to change without notice. 7 2001-08-10