Features
Version
Long Range
Connection type
Ethernet
Reading field
Oscillating mirror
Scanner design
Line scanner
Focus
Fixed focus
Light source
Visible red light (655 nm)
MTBF
40,000 h
Laser class
2 (EN 60825-1 (A2:2001-03), IEC 60825-1 : 2007-03, Ed. 2.0)
Aperture angle
≤ 50°
Scanning frequency
400 Hz ... 1,200 Hz
Code resolution
0.35 mm ... 1 mm
Reading distance
45 mm ... 659 mm 1)
Oscillating mirror functions
Fixed (adjustable position), oscillating (variable or fixed amplitude), one shot
Oscillation frequency 0.5 Hz ... 6.25 Hz
Angle of deflection –20° ... 20°
Heating
1)
Optional
For details see reading field diagram.
Performance
Bar code types
All current code types, Code 39, Code 128, Code 93, Codabar, GS1-128 / EAN 128, UPC /
GTIN / EAN, Interleaved 2 of 5, Pharmacode, GS1 DataBar, Telepen, MSI/Plessey
Print ratio
2:1 ... 3:1
No. of codes per scan
1 ... 20 (Standard decoder)
1 ... 6 (SMART decoder)
No. of codes per reading interval
1 ... 50 (auto-discriminating)
No. of characters per reading interval
5,000
500 (for multiplexer function in CAN operation)
2
IDENTIFICATION SOLUTIONS | SICK
Online data sheet | 2017-03-21 14:30:08
Subject to change without notice
CLV630-6120 | CLV63x
BAR CODE SCANNERS
No. of multiple readings
1 ... 99
Interfaces
✔
Ethernet TCP/IP
Function Host, AUX
Data transmission rate 10/100 MBit/s
✔
PROFINET
Function PROFINET Single Port, PROFINET Dual Port (optional via external connection module
CDF600-2)
Data transmission rate 10/100 MBit/s
✔
EtherNet/IP™
Data transmission rate 10/100 MBit/s
✔
EtherCAT®
Type of fieldbus integration Optional over external fieldbus module CDF600
✔, RS-232, RS-422, RS-485
Serial
Function Host, AUX
Data transmission rate 2,400 Baud ... 115.2 kBaud, AUX: 57.6 kBaud (RS-232)
✔
CAN
Function SICK CAN sensor network (Master/Slave, Multiplexer/Server)
Data transmission rate 20 kbit/s ... 1 Mbit/s
✔
CANopen
Data transmission rate 20 kbit/s ... 1 Mbit/s
✔
PROFIBUS DP
Type of fieldbus integration Optional over external fieldbus module CDF600-2
✔
DeviceNet™
Type of fieldbus integration Optional via external connection module CDM + CMF
Switching inputs
3 (“Sensor 1”, 2 inputs via optional parameter storage CMC600 in CDB620/CDM420)
Switching outputs
2 (via CMC600 in CDB620/CDM420)
Reading pulse
Switching input “Sensor 1”, non-powered, serial interface, auto pulse, CAN
Optical indicators
6 LEDs (Ready, Result, laser, Data, CAN, LNK TX, Bar graph for displaying the reading rate percentage (10 LEDs))
Acoustic indicators
Beeper/buzzer (can be switched off, can be allocated as a result indication function)
Operating elements
2 buttons (choose and start/stop functions)
Configuration software
SOPAS ET
Memory card
MicroSD memory card (flash card) 512 MB, optional
Mechanics/electronics
Electrical connection
2 x M12 cylindrical connectors (12-pin male connector, 4-pin female connector) on swivel connector
Operating voltage
18 V DC ... 30 V DC
Power consumption
6W
Housing
Aluminum die cast
Housing color
Light blue (RAL 5012)
1)
Swivel connector is 15 mm longer.
2017-03-21 14:30:08 | Online data sheet

Subject
to change without notice
IDENTIFICATION SOLUTIONS | SICK
3
CLV630-6120 | CLV63x
BAR CODE SCANNERS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Front screen
Glass
Enclosure rating
IP65 (EN 60529)
Protection class
III (EN 61140)
Weight
350 g, without connecting cable
Dimensions (L x W x H)
95 mm x 96 mm x 41 mm 1)
1)
Swivel connector is 15 mm longer.
Ambient data
Electromagnetic compatibility (EMC)
EN 61000-6-3 (2001-10) / EN 61000-6-2:2005
Vibration resistance
EN 60068-2-6 (1995)
Shock resistance
EN 60068-2-27 (1993)
Ambient operating temperature
0 °C ... +40 °C
Storage temperature
–20 °C ... +70 °C
Permissible relative humidity
90 %, Non-condensing
Ambient light immunity
2,000 lx, on bar code
Bar code print contrast (PCS)
≥ 60 %
Classifications
ECl@ss 5.0
27280102
ECl@ss 5.1.4
27280102
ECl@ss 6.0
27280102
ECl@ss 6.2
27280102
ECl@ss 7.0
27280102
ECl@ss 8.0
27280102
ECl@ss 8.1
27280102
ECl@ss 9.0
27280102
ETIM 5.0
EC002550
ETIM 6.0
EC002550
UNSPSC 16.0901
43211701
4
IDENTIFICATION SOLUTIONS | SICK
Online data sheet | 2017-03-21 14:30:08
Subject to change without notice
CLV630-6120 | CLV63x
BAR CODE SCANNERS
Dimensional drawing (Dimensions in mm (inch))
CLV63x/64x/65x, JEF3xx, JEF5xx, Ethernet, oscillating mirror
22.5
(0.89)
(0.22)
10
1
5.7
5°
61.2 (2.41)
28.3
(24.1)
)
31.2
(1.39)
(1.23)
22
Data
Adjusting
CAN
Userdefined
LNK TX
59.5 (2.34)
50°
8
7
38 (1.50)
15 (0.59)
6 5
(0.88)
Auto-Setup
65.4 (2.57)
Laser
85 (3.35)
15 (0.59)
15 (0.59)
TeachIn
65.2 (2.57)
Result
96 (3.78)
Read Diagn
11 (0.43)
0%
Ready
68 (2.68)
87 (3.43)
100%
(1.20)
(0.87)
82.1 (3.23)
41 (1.61)
(0.95)
35.3
(30.6)
11
16 (0.63)
4
9 (0.35)
2
(0.43)
(1.11
22.4
20°
20°
10
0.48 (0.02)
9
(0.39)
13.7 (0.54)
95 (3.74)
70.8 (2.79)
11.3 (0.44)
3
①
②
③
④
⑤
⑥
⑧
⑨
(0.39)
10
(0.89)
(0.22)
22.5
1
5.7
15 (0.59)
Blind hole thread M5, 5 mm deep (2 x), for mounting
Function button (2 x)
Reading field
Cover for the microSD memory card
Central position of the deflected laser beam in the V-shaped aperture angle
Internal impact point: rotation point of the variable direction laser beam
LED status indicator (6x) and bar graph
Reference point for reading distance (from housing edge to object)
2017-03-21 14:30:08 | Online data sheet

Subject
to change without notice
IDENTIFICATION SOLUTIONS | SICK
5
CLV630-6120 | CLV63x
BAR CODE SCANNERS
A
B
C
D
E
F
Reading field diagram
Reading field height in mm (inch)
400
(15.75)
300
(11.81)
200
(7.87)
100
(3.94)
a
b
c
0
–100
(–3.94)
–200
(–7.87)
–300
(–11.81)
–400
(–15.75)
H
I
J
K
L
M
N
O
P
Q
R
S
T
0
200
400
600
800
(7.87)
(15.75)
(23.62)
(31.5)
Reading distance in mm (inch)
Resolution
a: 0.35 mm (13.8 mil)
b: 0.50 mm (19.7 mil)
c: 1.0 mm (39.4 mil)
Recommended accessories
Other models and accessories
www.sick.com/CLV63x
Brief description
Type
Part no.
Hanger-shaped mounting bracket, mounting hardware included
Mounting bracket
2042800
Hanger-shaped mounting bracket, thermally isolated for use with heating devices,
mounting hardware included
Mounting bracket
2050705
CDB620-001
1042256
CDM420-0001
1025362
Head A: female connector, M12, 12-pin, straight
Head B: male connector, D-Sub-HD, 15-pin, straight
Cable: Power, serial, CAN, digital I/Os, shielded, 2 m
Connection cable
(male connector female connector)
2041834
Head A: male connector, M12, 4-pin, straight, D-coded
Head B: male connector, RJ45, 8-pin, straight
Cable: Ethernet, drag chain use, PUR, shielded, 2 m
SSL-2J04-G02ME
6034414
Mounting brackets and plates
Modules
Small connection module for one sensor, 4 cable glands, base for CMC600
Modular connection module for one sensor
Plug connectors and cables
6
IDENTIFICATION SOLUTIONS | SICK
Online data sheet | 2017-03-21 14:30:08
Subject to change without notice
Online data sheet
SICK at a glance
SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applications. A unique range of products and services creates the perfect basis for controlling processes securely
and efficiently, protecting individuals from accidents and preventing damage to the environment.
We have extensive experience in a wide range of industries and understand their processes and requirements. With intelligent sensors, we can deliver exactly what our customers need. In application centers in
Europe, Asia and North America, system solutions are tested and optimized in accordance with customer
specifications. All this makes us a reliable supplier and development partner.
Comprehensive services complete our offering: SICK LifeTime Services provide support throughout the machine life cycle and ensure safety and productivity.
For us, that is “Sensor Intelligence.”
Worldwide presence:
Contacts and other locations – www.sick.com
SICK AG | Waldkirch | Germany | www.sick.com
Similar pages