Online data sheet CLV630-6120 CLV63x BAR CODE SCANNERS CLV630-6120 | CLV63x BAR CODE SCANNERS A B C D E F Ordering information Type Part no. CLV630-6120 1041977 Other models and accessories www.sick.com/CLV63x Detailed technical data H I J K L M N O P Q R S T Features Version Long Range Connection type Ethernet Reading field Oscillating mirror Scanner design Line scanner Focus Fixed focus Light source Visible red light (655 nm) MTBF 40,000 h Laser class 2 (EN 60825-1 (A2:2001-03), IEC 60825-1 : 2007-03, Ed. 2.0) Aperture angle ≤ 50° Scanning frequency 400 Hz ... 1,200 Hz Code resolution 0.35 mm ... 1 mm Reading distance 45 mm ... 659 mm 1) Oscillating mirror functions Fixed (adjustable position), oscillating (variable or fixed amplitude), one shot Oscillation frequency 0.5 Hz ... 6.25 Hz Angle of deflection –20° ... 20° Heating 1) Optional For details see reading field diagram. Performance Bar code types All current code types, Code 39, Code 128, Code 93, Codabar, GS1-128 / EAN 128, UPC / GTIN / EAN, Interleaved 2 of 5, Pharmacode, GS1 DataBar, Telepen, MSI/Plessey Print ratio 2:1 ... 3:1 No. of codes per scan 1 ... 20 (Standard decoder) 1 ... 6 (SMART decoder) No. of codes per reading interval 1 ... 50 (auto-discriminating) No. of characters per reading interval 5,000 500 (for multiplexer function in CAN operation) 2 IDENTIFICATION SOLUTIONS | SICK Online data sheet | 2017-03-21 14:30:08 Subject to change without notice CLV630-6120 | CLV63x BAR CODE SCANNERS No. of multiple readings 1 ... 99 Interfaces ✔ Ethernet TCP/IP Function Host, AUX Data transmission rate 10/100 MBit/s ✔ PROFINET Function PROFINET Single Port, PROFINET Dual Port (optional via external connection module CDF600-2) Data transmission rate 10/100 MBit/s ✔ EtherNet/IP™ Data transmission rate 10/100 MBit/s ✔ EtherCAT® Type of fieldbus integration Optional over external fieldbus module CDF600 ✔, RS-232, RS-422, RS-485 Serial Function Host, AUX Data transmission rate 2,400 Baud ... 115.2 kBaud, AUX: 57.6 kBaud (RS-232) ✔ CAN Function SICK CAN sensor network (Master/Slave, Multiplexer/Server) Data transmission rate 20 kbit/s ... 1 Mbit/s ✔ CANopen Data transmission rate 20 kbit/s ... 1 Mbit/s ✔ PROFIBUS DP Type of fieldbus integration Optional over external fieldbus module CDF600-2 ✔ DeviceNet™ Type of fieldbus integration Optional via external connection module CDM + CMF Switching inputs 3 (“Sensor 1”, 2 inputs via optional parameter storage CMC600 in CDB620/CDM420) Switching outputs 2 (via CMC600 in CDB620/CDM420) Reading pulse Switching input “Sensor 1”, non-powered, serial interface, auto pulse, CAN Optical indicators 6 LEDs (Ready, Result, laser, Data, CAN, LNK TX, Bar graph for displaying the reading rate percentage (10 LEDs)) Acoustic indicators Beeper/buzzer (can be switched off, can be allocated as a result indication function) Operating elements 2 buttons (choose and start/stop functions) Configuration software SOPAS ET Memory card MicroSD memory card (flash card) 512 MB, optional Mechanics/electronics Electrical connection 2 x M12 cylindrical connectors (12-pin male connector, 4-pin female connector) on swivel connector Operating voltage 18 V DC ... 30 V DC Power consumption 6W Housing Aluminum die cast Housing color Light blue (RAL 5012) 1) Swivel connector is 15 mm longer. 2017-03-21 14:30:08 | Online data sheet Subject to change without notice IDENTIFICATION SOLUTIONS | SICK 3 CLV630-6120 | CLV63x BAR CODE SCANNERS A B C D E F H I J K L M N O P Q R S T Front screen Glass Enclosure rating IP65 (EN 60529) Protection class III (EN 61140) Weight 350 g, without connecting cable Dimensions (L x W x H) 95 mm x 96 mm x 41 mm 1) 1) Swivel connector is 15 mm longer. Ambient data Electromagnetic compatibility (EMC) EN 61000-6-3 (2001-10) / EN 61000-6-2:2005 Vibration resistance EN 60068-2-6 (1995) Shock resistance EN 60068-2-27 (1993) Ambient operating temperature 0 °C ... +40 °C Storage temperature –20 °C ... +70 °C Permissible relative humidity 90 %, Non-condensing Ambient light immunity 2,000 lx, on bar code Bar code print contrast (PCS) ≥ 60 % Classifications ECl@ss 5.0 27280102 ECl@ss 5.1.4 27280102 ECl@ss 6.0 27280102 ECl@ss 6.2 27280102 ECl@ss 7.0 27280102 ECl@ss 8.0 27280102 ECl@ss 8.1 27280102 ECl@ss 9.0 27280102 ETIM 5.0 EC002550 ETIM 6.0 EC002550 UNSPSC 16.0901 43211701 4 IDENTIFICATION SOLUTIONS | SICK Online data sheet | 2017-03-21 14:30:08 Subject to change without notice CLV630-6120 | CLV63x BAR CODE SCANNERS Dimensional drawing (Dimensions in mm (inch)) CLV63x/64x/65x, JEF3xx, JEF5xx, Ethernet, oscillating mirror 22.5 (0.89) (0.22) 10 1 5.7 5° 61.2 (2.41) 28.3 (24.1) ) 31.2 (1.39) (1.23) 22 Data Adjusting CAN Userdefined LNK TX 59.5 (2.34) 50° 8 7 38 (1.50) 15 (0.59) 6 5 (0.88) Auto-Setup 65.4 (2.57) Laser 85 (3.35) 15 (0.59) 15 (0.59) TeachIn 65.2 (2.57) Result 96 (3.78) Read Diagn 11 (0.43) 0% Ready 68 (2.68) 87 (3.43) 100% (1.20) (0.87) 82.1 (3.23) 41 (1.61) (0.95) 35.3 (30.6) 11 16 (0.63) 4 9 (0.35) 2 (0.43) (1.11 22.4 20° 20° 10 0.48 (0.02) 9 (0.39) 13.7 (0.54) 95 (3.74) 70.8 (2.79) 11.3 (0.44) 3 ① ② ③ ④ ⑤ ⑥ ⑧ ⑨ (0.39) 10 (0.89) (0.22) 22.5 1 5.7 15 (0.59) Blind hole thread M5, 5 mm deep (2 x), for mounting Function button (2 x) Reading field Cover for the microSD memory card Central position of the deflected laser beam in the V-shaped aperture angle Internal impact point: rotation point of the variable direction laser beam LED status indicator (6x) and bar graph Reference point for reading distance (from housing edge to object) 2017-03-21 14:30:08 | Online data sheet Subject to change without notice IDENTIFICATION SOLUTIONS | SICK 5 CLV630-6120 | CLV63x BAR CODE SCANNERS A B C D E F Reading field diagram Reading field height in mm (inch) 400 (15.75) 300 (11.81) 200 (7.87) 100 (3.94) a b c 0 –100 (–3.94) –200 (–7.87) –300 (–11.81) –400 (–15.75) H I J K L M N O P Q R S T 0 200 400 600 800 (7.87) (15.75) (23.62) (31.5) Reading distance in mm (inch) Resolution a: 0.35 mm (13.8 mil) b: 0.50 mm (19.7 mil) c: 1.0 mm (39.4 mil) Recommended accessories Other models and accessories www.sick.com/CLV63x Brief description Type Part no. Hanger-shaped mounting bracket, mounting hardware included Mounting bracket 2042800 Hanger-shaped mounting bracket, thermally isolated for use with heating devices, mounting hardware included Mounting bracket 2050705 CDB620-001 1042256 CDM420-0001 1025362 Head A: female connector, M12, 12-pin, straight Head B: male connector, D-Sub-HD, 15-pin, straight Cable: Power, serial, CAN, digital I/Os, shielded, 2 m Connection cable (male connector female connector) 2041834 Head A: male connector, M12, 4-pin, straight, D-coded Head B: male connector, RJ45, 8-pin, straight Cable: Ethernet, drag chain use, PUR, shielded, 2 m SSL-2J04-G02ME 6034414 Mounting brackets and plates Modules Small connection module for one sensor, 4 cable glands, base for CMC600 Modular connection module for one sensor Plug connectors and cables 6 IDENTIFICATION SOLUTIONS | SICK Online data sheet | 2017-03-21 14:30:08 Subject to change without notice Online data sheet SICK at a glance SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applications. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and requirements. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK LifeTime Services provide support throughout the machine life cycle and ensure safety and productivity. For us, that is “Sensor Intelligence.” Worldwide presence: Contacts and other locations – www.sick.com SICK AG | Waldkirch | Germany | www.sick.com