Click on Series name for product info on aimtec.com Series AMEPR30D-AZ up to 2A | AC-DC LED driver FEATURES: Models Single output Model +Suffix② AMEPR30D-5070AZ AMEPR30D-4270AZ+Suffix② AMEPR30D-3670AZ+Suffix② AMEPR30D-36100AZ+Suffix② AMEPR30D-24125AZ+Suffix② AMEPR30D-24140AZ+Suffix② AMEPR30D-15200AZ+Suffix② AC-DC Constant current LED Driver Input range 90-264VAC/47-440Hz Active PFC with TRIAC dimmable② Operating temperature -20 to 80°C Total Harmonic Distortion < 20% 5 Year Limited Warranty Max Output Power (W)① Output Voltage Range (V) No Load Output Voltage (V max.) Output Current (A) 35 29.4 25.2 36 30 33.6 30 36-50 32-42 24-36 24-36 12-24 12-24 8-15 64 54 52 52 34 34 23 0.7 0.7 0.7 1 1.25 1.4 2 Leading or Trailing Edge Triac IP67 Case High Efficiency up to 87% SCP, Over Load Protection Efficiency (%) Input Voltage (VAC/Hz) 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 115 230 VAC VAC 82 84 83 83 82 80 81 85 87 84 84 84 83 83 ① Exceeding the maximum output power will permanently damage the converter. ② Model Nomenclature for Ordering: Add Suffix “-U” Universal AC input 90-264VAC, (no TRIAC dimming option) Add Suffix “-110” AC input 90-135VAC, 115VAC typical value Add Suffix “-220” AC input 180-264VAC, 230VAC typical value NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C, humidity<75%, nominal input voltage (115/230VAC) and at rated output load unless otherwise specified. See http://www.aimtec.com/termssale AMEPR30D-AZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations prior to installation may damage sensitive equipment permanently. Input Specifications Parameters Inrush current <2ms (cold start) Conditions Typical 115VAC 230VAC 15 30 0.25 500 350 Leakage current AC current Power Factor External fuse Start up time 115VAC 230VAC 115VAC 230VAC Recommended slow blow type Maximum Units A mA mA 0.9 0.9 1 200 A ms Output Specifications Parameters Current accuracy Line regulation Load regulation www.aimtec.com F 052.1e R3.S Conditions Typical LL-HL 0-100% load ±7 ±10 ±7 Tel: +1 514 620 2722 1 of 5 Maximum Units % % % Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR30D-AZ up to 2A | AC-DC LED driver Output Specifications (continued) Parameters Conditions Typical Maximum Units 3 Ripple & Noise ③ Hold-up time 1 Minimum Load Voltage See the models table ③ Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) or (C/C) and 47µF (E/C) parallel capacitor. V p-p ms Isolation Specifications Parameters Conditions Tested I/O voltage Isolation Resistance Typical 60sec Maximum Units 3000 VAC MΩ >1000 General Specifications Parameters Conditions Switching frequency Over load protection Over voltage protection Short circuit protection Over temperature protection Operating temperature Maximum case temperature Storage temperature Temperature coefficient Cooling Humidity Case material Wires Weight Dimensions (L X H X W) MTBF Typical Maximum 65 ≧110 ≧110 Auto recovery >105°C -20 to +80 With derating over 55°C Units KHz % % oC 100 oC oC -40 to +95 ±0.02 Free air convection % / oC 95 Plastic UL1015 Input 18AWG*10CM/ Output 20 AWG * 10CM 200 133x33x30mm (5.24 x 1.30 x 1.18 inch) >400,000 hrs (MIL-HDBK-217F at +25°C) % RH g Environment Approval Test Shock Vibration Parameters Wave form Acceleration amplitude Bump duration Converter operation Number of bumps Test mode Displacement Acceleration Converter operation Conditions Half sine wave 5gn 30 ms Before and after test, body mounted (on chassis) 18 (3 in each direction for every axis) Sweep sine, 10-100Hz, speed 0.05Hz/s 1 mm 3g, 3 loops 30min one cycle, 3h total, every axis tested Before and after test, body mounted (on chassis) Safety Specifications Parameters Agency approvals Standards www.aimtec.com F 052.1e R3.S cULus, CE, FCC EN61347-1, EN61347-2-13, IEC62384, UL8750, UL60950-1, EN55015, EN55024, FCC Part 15 Subpart B, Class B, ANSI C63.4 :2003 Harmonic Current Emissions IEC/EN 61000-3-2, Class C Voltage fluctuations and flicker IEC/EN 61000-3-3, (EN60555-3) Electrostatic Discharge Immunity IEC 61000-4-2 Level 3 RF, Electromagnetic Field Immunity IEC 61000-4-3 Level 2 Electrical Fast Transient/Burst Immunity IEC 61000-4-4 Level 2 Surge Immunity IEC 61000-4-5 Level 2 RF, Conducted Disturbance Immunity IEC 61000-4-6 Level 2 Power frequency Magnetic Field Immunity IEC 61000-4-8 Level 2 Voltage dips, Short Interruptions Immunity IEC 61000-4-11 Tel: +1 514 620 2722 2 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR30D-AZ up to 2A | AC-DC LED driver Dimensions Temperature Graph Free Air Convection 55 º C 100 80 Safe Operating Area 60 40 20 0 - 25 - 20 0 20 40 60 80 100 Ambient Temperature º C www.aimtec.com F 052.1e R3.S Tel: +1 514 620 2722 3 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR30D-AZ up to 2A | AC-DC LED driver Triac Dimming Feature www.aimtec.com F 052.1e R3.S Tel: +1 514 620 2722 4 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR30D-AZ up to 2A | AC-DC LED driver Triac Dimming Performance AMEPR30D-3670AZ (mA) Dimming Performance(Input 110Vac) 700 653 600 533 602 NS‐1223B LUTRON DVCL‐ 15SP‐WH 500 386 400 300 240 200 100 15 0 38 20 70 (mA) 120 170 Angle Dimming Performance(Input 230 Vac) 800 712 700 629 614 600 NS‐1223C 678 609 Berker 286710 LUTRON LLSI‐ 502B‐FAW‐M LUTRON RNSI‐ 452 525 500 427 449 400 300 257 205 200 158 75 100 20 0 20 70 96 102 70 120 170 220 Angle Triac dimming performance is typical as with other models, for specific details on other model performance, please see the Aimtec Triac Dimming Application note at www.aimtec.com NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified.5..Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 5. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. www.aimtec.com F 052.1e R3.S Tel: +1 514 620 2722 5 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only