Arch AQF100O-24S Ac-dc switching power supply Datasheet

VER : A_6
update : 2012.05.14
AC-DC Switching Power Supply
AQF100O SERIES
100 Watts
KEY FEATURES
„
„
„
„
„
„
„
„
„
„
Standard
Open Frame 100W Power Supply in 4.0” x 2.0” Size
High Efficiency up to 93% Typical
Active PFC Function, >0.95 (230Vac), >0.99 (115Vac)
Universal Input: 90-264 VAC
100W Full Load at 50°C Under Free Air Convection
120W with FAN (20CFM / 300LFM)
Low Leakage Current, <250uA
EN55022 Class B Meets
Class I and Class II Construction
Continuous Short Circuit Protection with Hiccup Mode
and Auto Recover
„ 3-Years Product Warranty
A Type
ELECTRICAL SPECIFICATIONS
Model No.
AQF100O-12S
Max Output Wattage (Free air Convection)
Max Output Wattage (with 20CFM / 300LFM FAN)
Voltage
Input
Output
Protection
Isolation
AQF100O-24S
(W)
AQF100O-48S
120 W
90-264 VAC or 120-370 VDC
Frequency (Hz)
47-63 Hz
Current (Full load)
<2.0 A max. (115 VAC) / <1.0 A max. (230 VAC)
Inrush Current (<2ms)
< 30 A max. (115 VAC) / < 60 A max. (230 VAC)
Leakage Current
< 0.5 mA max.
Power Factor
PF>0.99 (115 VAC) / PF>0.95 (230 VAC) at Full Load
Voltage (V.DC.)
12V
Voltage Adj Range (V.DC.)
±5% Output Voltage
15V
24V
48V
Voltage Accuracy
±2%
Current (Free air Convection) (A) max
8.4
6.7
4.2
2.1
Current (with 20CFM / 300LFM FAN) (A) max
10
8
5
2.5
Line Regulation
±1%
Load Regulation
±1%
Minimum Load
3%
Maximum Capacitive Load
70,000µF
50,000µF
6,000µF
1,000µF
Ripple & Noise max.
120mV
150mV
200mV
240mV
Efficiency (typ.)
89%
89%
92%
93%
Hold-up Time
10 ms (110 VAC) min.
Switching Frequency
100~133 kHz
Over Power Protection
Auto recovery, Hiccup mode
Over Voltage Protection
Zener diode clamp
Short Circuit Protection
Auto recovery, Hiccup mode
Input-Output (V.AC)
3000V
Input-FG
(V.AC)
1500V
Output-FG
.(V.AC)
500V
Operating Temperature
Environment
AQF100O-15S
100 W
(W)
-25°C…+70°C (with derating)
Storage Temperature
-25°C…+85°C
Temperature Coefficient
±0.03%/°C ( 0~50°C )
Humidity
95% RH
MTBF
>250,000 h @ 25°C (MIL-HDBK-217F, Notice 1)
Vibration
10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes.
1.All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
2.Ripple & Noise are measured at 20MHz of bandwidth with 0.1UF & 47UF parallel capacitor.
3.Hold-up Time measured at 90% Vout.
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-1-
VER : A_6
update : 2012.05.14
AC-DC Switching Power Supply
AQF100O SERIES
100 Watts
Model No.
Physical
AQF100O-12S
AQF100O-15S
Dimension (L x W x H)
4.1 x 2.05 x 0.98 Inches
Weight
200 g
Cooling Method
Free convection
Safety
Agency Approvals
EMI
CE, UL60950-1
EMC
(Conducted & Radiated Emission)
AQF100O-24S
AQF100O-48S
( 103.9 x 52.1 x 25.0 mm ) Tolerance ±0.5 mm
EN61000-6-3、EN 55022 class B (Conductive plane to be connected to safety earth)
EN 55024、EN61000-4-2,3,4,5,6,8,11
EMS (Noise Immunity)
1.All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
2.Ripple & Noise are measured at 20MHz of bandwidth with 0.1UF & 47UF parallel capacitor.
3.Hold-up Time measured at 90% Vout.
DERATING
BLOCK DIAGRAM
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-2-
VER : A_6
update : 2012.05.14
AC-DC Switching Power Supply
AQF100O SERIES
MECHANICAL DIMENSION
100 Watts
( Top View )
Standard : Terminal Block
PIN#
SINGLE
1
AC IN (N)
2
AC IN (L)
3
+DC OUT
4
-DC OUT
PIN#
SINGLE
1
AC IN (N)
2
AC IN (L)
3
+DC OUT
4
+DC OUT
5
-DC OUT
6
-DC OUT
A Type : Molex Series 8673 (Alex Connector Co., ltd)
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-3-
VER : A_6
update : 2012.05.14
AC-DC Switching Power Supply
AQF100O SERIES
100 Watts
EFFICIENCY VERSUS LOAD
AQF100O-12S
VIN
Input Voltage (V)
Efficiency (%)
VS
Efficiency
Efficiency
115
180
230
264
Load (%)
10
20
30
40
50
87.38
89.03
90.31
90.22
90.66
115V (%)
74.98
83.50
86.13
87.83
88.70
230V (%)
65.30
77.58
82.39
85.30
87.01
Load (%)
60
70
80
90
100
115V (%)
88.87
89.11
89.20
89.13
89.03
230V (%)
87.95
88.63
89.14
89.46
90.22
80%
100%
100.00%
95.00%
95.00%
90.00%
90.00%
85.00%
EFF%
85.00%
EFF%
VS
90
100.00%
80.00%
75.00%
80.00%
75.00%
70.00%
70.00%
65.00%
65.00%
60.00%
60.00%
90V
LOAD
55.00%
115V
180V
230V
264V
10%
20%
30%
40%
50%
VIN
60%
70%
90%
LOAD
AQF100O-15S
VIN
Input Voltage (V)
Efficiency
VS
Efficiency
115
180
230
264
Load (%)
10
20
30
40
50
87.03
88.49
89.45
89.81
89.89
115V (%)
65.23
75.04
81.54
84.42
85.92
230V (%)
63.23
76.35
81.29
84.36
86.12
Load (%)
60
70
80
90
100
115V (%)
87.07
87.47
87.96
88.51
88.49
230V (%)
87.88%
88.51%
89.17%
89.77%
89.81%
100.00%
100.00%
95.00%
95.00%
90.00%
90.00%
85.00%
85.00%
80.00%
80.00%
75.00%
75.00%
70.00%
70.00%
65.00%
65.00%
60.00%
90V
LOAD
90
EFF%
EFF%
Efficiency (%)
VS
60.00%
115V
180V
VIN
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
230V
264V
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
LOAD
-4-
VER : A_6
update : 2012.05.14
AC-DC Switching Power Supply
AQF100O SERIES
100 Watts
EFFICIENCY VERSUS LOAD
AQF100O-24S
VIN
Input Voltage (V)
Efficiency
VS
Efficiency
115
180
230
264
Load (%)
10
20
30
40
50
90.53
91.90
92.44
92.85
93.13
115V (%)
74.99
83.78
87.43
89.22
90.44
230V (%)
65.32
79.51
85.76
88.32
90.04
Load (%)
60
70
80
90
100
115V (%)
90.99
91.43
91.72
91.89
91.90
230V (%)
91.08
91.76
92.23
92.64
92.85
80%
100%
100.00%
100.00%
95.00%
95.00%
90.00%
90.00%
85.00%
85.00%
80.00%
80.00%
75.00%
75.00%
70.00%
70.00%
65.00%
65.00%
60.00%
90V
LOAD
90
EFF%
EFF%
Efficiency (%)
VS
60.00%
115V
180V
230V
264V
10%
20%
30%
40%
50%
VIN
60%
70%
90%
LOAD
AQF100O-48S
VIN
Input Voltage (V)
Efficiency (%)
VS
Efficiency
Efficiency
115
180
230
264
Load (%)
10
20
30
40
50
90.27
91.64
92.81
93.03
93.35
115V (%)
73.93
83.86
87.18
89.22
90.34
230V (%)
66.76
79.70
84.80
87.75
89.62
Load (%)
60
70
80
90
100
115V (%)
90.82
91.28
91.53
91.64
91.64
230V (%)
90.77
91.47
92.09
92.49
93.03
80%
100%
100.00%
95.00%
95.00%
90.00%
90.00%
85.00%
EFF%
85.00%
EFF%
VS
90
100.00%
80.00%
75.00%
80.00%
75.00%
70.00%
70.00%
65.00%
65.00%
60.00%
60.00%
90V
LOAD
55.00%
115V
180V
VIN
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
230V
264V
10%
20%
30%
40%
50%
60%
70%
90%
LOAD
-5-