Crydom CMD60110 Panel mount Datasheet

CMD / CMA60 Series
• Ratings from 25A to 125A @ 48-660 VAC
• SCR output for heavy industrial loads
• AC or DC control
• LED input status indicator
• Zero-crossing (resistive loads) or random-fire (inductive loads) output
• IP20 touch-safe housing
• Standard box-clamp connections
• Ratings from 25A to 125A @ 48-660 VAC
PRODUCT SELECTION
Control Voltage
4-32 VDC
90-140 Vrms
18-36 Vrms
25A
50A
75A
90A
110A
125A
CMD6025
CMA6025
CMA6025E
CMD6050
CMA6050
CMA6050E
CMD6075
CMA6075
CMA6075E
CMD6090
CMA6090
CMA6090E
CMD60110
CMA60110
CMA60110E
CMD60125
CMA60125
CMA60125E
AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS (1)
Description
Operating Voltage (47-63Hz) [Vrms]
Transient Overvoltage [Vpk]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2)
Maximum Load Current (3) [Arms]
Minimum Load Current [Arms]
Maximum 1 Cycle Surge Current (50/60) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (Rjc) [°C/W]
Maximum I² t for Fusing 50/60Hz (1/2 cycle) [A² sec]
Minimum Power Factor (with Maximum Load)
25A
50A
75A
90A
110A
125A
48-660
1200
1.0
500
25
0.15
239/250
1.6
1.02
285/259
0.5
48-660
1200
1.0
500
50
0.15
597/625
1.6
0.63
1779/1621
0.5
48-660
1200
1.0
500
75
0.25
954/1000
1.6
0.31
4555/4150
0.5
48-660
1200
1.0
500
90
0.25
1145/1200
1.6
0.28
6560/5976
0.5
48-660
1200
1.0
500
110
0.25
1432/1500
1.6
0.25
10249/9338
0.5
48-660
1200
1.0
500
125
0.025
1670/1750
1.6
0.22
13950/12709
0.5
INPUT SPECIFICATIONS (1)
Description
Control Voltage Range
Maximum Reverse Voltage
Minimum Turn-On Voltage
Minimum Turn-Off Voltage
Maximum Input Current
Typical Input current
Maximum Turn-On Time [msec] (4)
Maximum Turn-Off Time [msec]
CMD
CMA
3-32 VDC
32 VDC
3.0 VDC
1.0 VDC
30 mA(5)
17 mA @ 5 VDC
1/2 Cycle
1/2 Cycle
90-140 Vrms
90 Vrms
10 Vrms
15 mA @ 120 Vrms
10
40
GENERAL SPECIFICATIONS
Description
Dielectric Strength, Input/Output/Base (50/60Hz)
Minimum Insulation Resistance (@ 500 VDC)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Status Indicating Display
Weight (typical)
Encapsulation
Terminals
Maximum Wire Size-Output:
Maximum Wire Size-Input:
Recommended Terminal Screw Torque Range:
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
3) HEAT SINKING REQUIRED, FOR DERATING curves see page 2.
4) Turn-on time for DC control random turn-on versions is 0.02msec
5) Input circuitry incorporates active current limiter.
Parameters
4000 Vrms
109 Ohm
8 pF
-40 to 80 °C
-40 to 125 °C
Green LED
3.0 oz (86.5 g)
Thermally conductive Epoxy
Cage type
AWG 8 (3.8mm)
AWG 12 (2.5mm)
Output: 10-15 in lb (1.1-1.7 Nm)
Input: 5-6 in lb (0.6-0.7 Nm)
MECHANICAL SPECIFICATIONS
THERMAL DERATE INFORMATION
AGENCY APPROVALS
Designed in accordance with the requirements of IEC 62314
UL E116949, E116950
LR81689
126921 UG (up to 90A models only)
Rev. 113011
ANNEX - ENVIROMENTAL INFORMATION