AIMTEC AM2L-0512SH60-NZ 2 watt | dc-dc converter Datasheet

Series AM2L-NZ
2 Watt | DC-DC Converter
FEATURES:




 MTBF>1,000,000 hours
 Operating temperature: -40°C to +85°C
Industry Standard Pinout
 High Efficiency up to 85%
Unregulated Single, Dual, Dual Separated Output Models
Low Profile SMD (Surface Mount Device)
1000VDC & 6000VDC Isolation
Models
Single output
Input Voltage
(V)
Output Voltage
(V)
AM2L-0505S-NZ
AM2L-0509S-NZ
AM2L-0512S-NZ
AM2L-0515S-NZ
AM2L-1205S-NZ
AM2L-1209S-NZ
AM2L-1212S-NZ
AM2L-1215S-NZ
4.5-5.5
4.5-5.5
4.5-5.5
4.5-5.5
10.8-13.2
10.8-13.2
10.8-13.2
10.8-13.2
5
9
12
15
5
9
12
15
AM2L-0505SH60-NZ
AM2L-0512SH60-NZ
AM2L-0515SH60-NZ
AM2L-1205SH60-NZ
AM2L-1212SH60-NZ
AM2L-1215SH60-NZ
AM2L-2405SH60-NZ
AM2L-2412SH60-NZ
AM2L-2415SH60-NZ
4.5-5.5
4.5-5.5
4.5-5.5
10.8-13.2
10.8-13.2
10.8-13.2
21.6-26.4
21.6-26.4
21.6-26.4
5
12
15
5
12
15
5
12
15
Input Voltage
(V)
Output Voltage
(V)
Model
Output Current
max (mA)
Isolation
(VDC)
Efficiency
(%)
400
222
167
133
400
222
167
133
1000
1000
1000
1000
1000
1000
1000
1000
80
82
84
84
82
83
85
85
400
167
133
400
167
133
400
167
133
6000
6000
6000
6000
6000
6000
6000
6000
6000
76
79
78
76
80
79
77
80
78
Output Current
max (mA)
Isolation
(VDC)
Efficiency
(%)
±200
±111
±83
±67
±200
±111
±83
±67
1000
1000
1000
1000
1000
1000
1000
1000
82
83
84
82
83
84
84
85
Output Current
max (mA)
Isolation
(VDC)
Efficiency
(%)
Models
Dual output
Model
AM2L-0505D-NZ
AM2L-0509D-NZ
AM2L-0512D-NZ
AM2L-0515D-NZ
AM2L-1205D-NZ
AM2L-1209D-NZ
AM2L-1212D-NZ
AM2L-1215D-NZ
4.5-5.5
4.5-5.5
4.5-5.5
4.5-5.5
10.8-13.2
10.8-13.2
10.8-13.2
10.8-13.2
±5
±9
±12
±15
±5
±9
±12
±15
Models
Dual Separated output
Model
Input Voltage
(V)
Output Voltage
(V)
AM2L-050505D-NZ
4.5-5.5
5/5
200/200
1000
82
AM2L-050909D-NZ
4.5-5.5
9/9
112/112
1000
83
AM2L-051515D-NZ
4.5-5.5
15/15
67/67
1000
85
AM2L-120505D-NZ
10.8-13.2
5/5
200/200
1000
82
AM2L-120909D-NZ
10.8-13.2
9/9
112/112
1000
83
AM2L-121515D-NZ
10.8-13.2
15/15
67/67
1000
85
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
www.aimtec.com
F 051e R12.H
Tel: +1 514 620 2722
1 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2L-NZ
2 Watt | DC-DC Converter
Input Specifications
Parameters
Voltage range
Nominal
Typical
5
12
24
4.5-5.5
10.8-13.2
21.6-26.4
Conditions
Typical
Maximum
Units
VDC
Isolation Specifications
Parameters
Tested I/O voltage
Tested V1 output/ V2 output
Capacitance V input/V output
Capacitance V1 output/V2 output
Resistance
60 sec
60 sec
500VDC
500VDC
500Vdc
Rated
Units
1000, 6000
VDC
VDC
pF
pF
MOhm
1000
60
60
>1000
Output Specifications
Parameters
Voltage accuracy
Short Circuit protection
Short Circuit Restart
Line voltage regulation
Load voltage regulation (5 Vout)
Load voltage regulation (9 Vout)
Load voltage regulation (12 Vout)
Load voltage regulation (15 Vout)
Temperature coefficient
Ripple & Noise*
Minimum Load Current**
Conditions
Typical
See Tolerance Graph
1000VDC Momentary
6000VDC Continuous
Maximum
±5
Units
%
1 sec
Auto-Recovery
±1.2
12.8
8.3
6.8
6.3
±0.03
150
10
For a 1% change of Vin
From 10% load to 100% load
At 100% load
20MHz Bandwidth
%
%
%/oC
mV p-p
% of Max
* Test ripple & noise by “Parallel Cable Method” as described in Application Note “Ripple and Noise Measurement of Brick &
POL DC-DC Converters” available on Aimtec’s website www.aimtec.com
** If the operating output current is less than 10% of maximum it is recommended to install a load resister in parallel with the
load to ensure the actual load current meets the minimum load current requirement.
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum Soldering Temperature
Conditions
Typical
100% load, nominal input
-40 to + 85
-55 to + 125
Maximum
Units
100
KHz
o
C
o
C
o
C
100
Free Air Convection
95
% RH
Plastic(UL94-V0)
1000VDC
2.1
g
6000VDC
3.8
Single, Dual, Dual Separated 1000VDC
0.70 x 0.70 x 0.24 inches
17.78 x 17.78 x 6.00 mm
Single 6000VDC
0.94 x 0.79 x 0.32 inches 23.86 x 18.50 x 8.00mm
> 1,000, 000 hours (MIL-HDBK -217F, Ground Benign, t=+25ºC)
o
1.5mm from case for 10 seconds
260
C
Safety Specifications
Parameters
Agency approvals
Standards
www.aimtec.com
F 051e R12.H
CE (for 6000VDC isolation models)
EN 60601-1-1; EN 60601-1-2
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2L-NZ
2 Watt | DC-DC Converter
Pin Out Specifications
1000VDC
Pin
Single
1
2
5
6
7
8
9
10
12
13
14
6000VDC
Dual
Separated
Dual
-Vin
+ Vin
NC
- Vout
+Vout
NC
NC
NC
NC
NC
NC
- Vin
+ Vin
-Vout
Common
+Vout
NC
NC
-Vout
NC
NC
NC
- Vin
+ Vin
-V1out
+V1out
NC
NC
+V2out
-V2out
NC
NC
NC
NOTE: On dual output models Pin 5 and Pin 10 are connected internally together.
Either Pin 5 or Pin 10, or both can be used as the -Vout
NC: not connected
Pin
Single
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
- V in
No Pin
No Pin
No Pin
No Pin
No Pin
NC
NC
+V out
-V out
No Pin
No Pin
No Pin
No Pin
No Pin
+V in
Dimensions
1000VDC
Side View
17.78
(0.70)
Front View
A
2.75
(0.11)
6.00 5.75
(0.24) (0.23)
0.25
(0.01)
A
2.54
(0.10)
1.27
(0.05)
Top View
17.78
(0.70)
1.00
2.00
(0.04) (0.08)
14
0.25
(0.01)
2.54
(0.10)
5.00º angle
13
12
10
9
8
2
3
5
6
7
1.30 ±0.13
(0.05 ±0.005) MAX
17.78 12.70
(0.70) (0.50)
1
www.aimtec.com
F 051e R12.H
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2L-NZ
2 Watt | DC-DC Converter
Dimensions
6000VDC
Tolerance Envelope Graph
+10%
Typical Load Line
+5%
+2.5%
Output Voltage
-2.5%
10%
www.aimtec.com
F 051e R12.H
-7.5%
50%
Output Current(%)
100%
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2L-NZ
2 Watt | DC-DC Converter
Recommended Filter Circuit
+ Vin
L
Single Output
L
+Vout + Vin
+
Cin +
DC
DC
+Vout
+
Cin +
Cout
L
Dual Output
L
DC
Common
DC
L
- Vin
- Vin
L
+ Vin
Dual Separated Output
DC
DC
+
Cout
- Vin
-Vout
L
+
Cin +
Cout
+V1output
Cout
-V1 output
L
+
+V2 output
Cout
-V2 output
- Vin
If it is required to decrease the input/output ripple an “LC” filter network can be installed on the input and output of the
converter (see above).
It should be noted that the inductance and the resonant frequency of the “LC” filtering network should differ from the DC/DC
converter switching frequency to avoid mutual interference.
The capacitance of the output filter capacitor must not exceed the values in the Table below to avoid startup problems and
ensure safe and reliable operation.
It’s not recommended to connect any external capacitor in the application field when output loading is less than 0.5
watt.
External Capacitor Tables
Input Capacitor (Cin)
Vin
(VDC)
Cin
(uF)
5
12
24
4.7
2.2
1
Output Capacitor (Cout)
Single
Vout
(VDC)
5
9
12
15
Cout
(uF)
Dual
Vout
(Vdc)
Cout
(uF)
Dual
Separated
Vout (Vdc)
Cout
(uF)
10
4.7
2.2
1
±5
±9
±12
±15
4.7
2.2
1
0.47
5/5
9/9
12/12
15/15
4.7
2.2
1
0.47
Overload Protection
The output circuit of these products has no protection against overload. It is recommended to install external overload
protection in the form of a self-recovery fuse or a circuit breaker in series at the converter’s input.
To achieve a high degree of output voltage regulation, over-voltage, and over-current protection it is suggested to use the
AM2LV-NZ series as an alternative.
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.H
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only