EPCOS B32671P Metallized polypropylene film capacitors (mkp) Datasheet

Film Capacitors
Metallized Polypropylene Film Capacitors (MKP)
Series/Type:
B32671P ... B32673P
Date:
April 2014
© EPCOS AG 2014. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.
Metallized polypropylene film capacitors (MKP)
B32671P ... B32673P
Power Factor Correction
Typical applications
PFC (Power Factor Correction)
Dimensional drawing
Climatic
Max. operating temperature: 125 °C
Climatic category (IEC 60068-1): 55/110/56
Construction
Dielectric: polypropylene (PP)
Wound capacitor technology
Plastic case (UL 94 V-0)
Epoxy resin sealing
Dimensions in mm
Features
Very compact design
Very small dimensions
Very high ripple and peak current
High frequency AC operation capability
High voltage capability
Excellent self-healing property
RoHS-compatible
Halogen-free capacitors available on request
Lead spacing
±0.4
10
15
22.5
Terminals
Parallel wire leads, lead free, tinned
Special lead lengths available on request
Marking
Manufacturer's logo
Lot number, series number
Rated capacitance (coded)
Capacitance tolerance (code letter)
Rated DC voltage
Date of manufacture (coded)
Delivery mode
Bulk (untaped)
Taped (Ammo pack or reel)
For notes on taping, refer to chapter "Taping and packing“.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 2 of 18
Lead diameter
d1 ±0.05
0.6
0.8
0.8
Type
B32671P
B32672P
B32673P
B32671P ... B32673P
Power Factor Correction
Overview of available types
Lead spacing 10 mm
15 mm
22.5 mm
Type
B32671P
B32672P
B32673P
Page
4
5
VRMS (V AC)
160
200
200
160
200
200
160
200
200
VR (V DC)
450
520
630
450
520
630
450
520
630
6
CR (µF)
0.068
0.082
0.10
0.15
0.18
0.22
0.27
0.33
0.39
0.47
0.56
0.68
1.0
1.5
2.0
2.2
Please read Cautions and warnings and
Important notes at the end of this document.
Page 3 of 18
B32671P
Power Factor Correction
Ordering codes and packing units (lead spacing 10 mm)
VR
V DC
VRMS
CR
f ≤1 kHz
V AC
µF
Ordering code
(composition see
below)
Max. dimensions
w×h×l
mm
450
160
520
200
630
200
B32671P4104+***
B32671P4154+***
B32671P4184+***
B32671P4224+***
B32671P4274+***
B32671P4334+***
B32671P4394+***
B32671P4474+***
B32671P4684+***
B32671P4105+***
B32671P5823+***
B32671P5104+***
B32671P5154+***
B32671P5224+***
B32671P5334+***
B32671P5474+***
B32671P6683+***
B32671P6823+***
B32671P6104+***
B32671P6154+***
B32671P6184+***
B32671P6224+***
B32671P6334+***
B32671P6394+***
4.0 × 9.0 × 13.0
4.0 × 9.0 × 13.0
5.0 × 11.0 × 13.0
5.0 × 11.0 × 13.0
5.0 × 11.0 × 13.0
6.0 × 12.0 × 13.0
6.0 × 12.0 × 13.0
6.0 × 14.0 × 13.0
7.0 × 16.0 × 13.0
8.0 × 17.5 × 13.0
4.0 × 9.0 × 13.0
5.0 × 11.0 × 13.0
5.0 × 11.0 × 13.0
6.0 × 12.0 × 13.0
7.0 × 16.0 × 13.0
8.0 × 17.5 × 13.0
4.0 × 9.0 × 13.0
5.0 × 11.0 × 13.0
5.0 × 11.0 × 13.0
6.0 × 12.0 × 13.0
6.0 × 12.0 × 13.0
6.0 × 14.0 × 13.0
8.0 × 17.5 × 13.0
8.0 × 17.5 × 13.0
0.10
0.15
0.18
0.22
0.27
0.33
0.39
0.47
0.68
1.0
0.082
0.10
0.15
0.22
0.33
0.47
0.068
0.082
0.10
0.15
0.18
0.22
0.33
0.39
Ammo
pack
pcs./MOQ
4000
4000
3320
3320
3320
2720
2720
2720
Reel
Untaped
pcs./MOQ
6800
6800
5200
5200
5200
4400
4400
4400
4000
3320
3320
2720
6800
5200
5200
4400
4000
3320
3320
2720
2720
2720
6800
5200
5200
4400
4400
4400
pcs./MOQ
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
MOQ = Minimum Order Quantity, consisting of 4 packing units.
Further E series, intermediate capacitance values and closer tolerance on request.
Composition of ordering code
+ = Capacitance tolerance code:
J = ±5%
K = ±10%
M = ±20%
Please read Cautions and warnings and
Important notes at the end of this document.
*** = Packaging code:
289 = Straight terminals, Ammo pack
189 = Straight terminals, Reel
240 = Crimped down to lead spacing 7.5 mm,
Ammo pack
140 = Crimped down to lead spacing 7.5 mm,
Reel
003 = Straight terminals, untaped (lead length
3.2 ± 0.3 mm)
000 = Straight terminals, untaped (lead length
61 mm)
Page 4 of 18
B32672P
Power Factor Correction
Ordering codes and packing units (lead spacing 15 mm)
VR
V DC
VRMS
CR
f ≤1 kHz
V AC
µF
Ordering code
(composition see
below)
450
160
520
200
630
200
B32672P4104+***
5.0 × 10.5 × 18.0
B32672P4224+***
5.0 × 10.5 × 18.0
B32672P4334+***
5.0 × 10.5 × 18.0
B32672P4474+***
5.0 × 10.5 × 18.0
B32672P4564+***
6.0 × 11.0 × 18.0
B32672P4684+***
6.0 × 12.0 × 18.0
B32672P4105+***
7.0 × 12.5 × 18.0
B32672P4155+***
9.0 × 17.5 × 18.0
B32672P4205+***
9.0 × 17.5 × 18.0
B32672P4225+*** 11.0 × 18.5 × 18.0
B32672P5154+***
5.0 × 10.5 × 18.0 4680
B32672P5224+***
5.0 × 10.5 × 18.0 4680
B32672P5334+***
6.0 × 11.0 × 18.0 3840
B32672P5474+***
7.0 × 12.5 × 18.0 3320
B32672P5684+***
8.5 × 14.5 × 18.0 2720
B32672P5105+***
9.0 × 17.5 × 18.0 2560
B32672P5155+*** 11.0 × 18.5 × 18.0
B32672P6154+***
5.0 × 10.5 × 18.0 4680
B32672P6224+***
6.0 × 11.0 × 18.0 3840
B32672P6334+***
7.0 × 12.5 × 18.0 3320
B32672P6474+***
8.0 × 14.0 × 18.0 2920
B32672P6684+***
9.0 × 17.5 × 18.0 2560
B32672P6105+*** 11.0 × 18.5 × 18.0
0.10
0.22
0.33
0.47
0.56
0.68
1.0
1.5
2.0
2.2
0.15
0.22
0.33
0.47
0.68
1.0
1.5
0.15
0.22
0.33
0.47
0.68
1.0
Max. dimensions
w×h×l
mm
Ammo
pack
pcs./MOQ
4680
4680
4680
4680
3840
3840
3320
2560
2560
Reel
Untaped
pcs./MOQ
5200
5200
5200
5200
4400
4400
3600
2800
2800
2200
5200
5200
4400
3600
2800
2800
2200
5200
4400
3600
3000
2800
2200
pcs./MOQ
4000
4000
4000
4000
4000
4000
4000
2000
2000
1200
4000
4000
4000
4000
2000
2000
1000
4000
4000
4000
2000
2000
1000
MOQ = Minimum Order Quantity, consisting of 4 packing units.
Further E series, intermediate capacitance values and closer tolerance on request.
Composition of ordering code
+ = Capacitance tolerance code:
J = ±5%
K = ±10%
M = ±20%
Please read Cautions and warnings and
Important notes at the end of this document.
*** = Packaging code:
289 = Straight terminals, Ammo pack
189 = Straight terminals, Reel
255 = Crimped down to lead spacing 7.5 mm,
Ammo pack
155 = Crimped down to lead spacing 7.5 mm,
Reel
003 = Straight terminals, untaped (lead length
3.2 ± 0.3 mm)
000 = Straight terminals, untaped (lead length
61 mm)
Page 5 of 18
B32673P
Power Factor Correction
Ordering codes and packing units (lead spacing 22.5 mm)
VR
V DC
VRMS
CR
f ≤1 kHz
V AC
µF
Ordering code
(composition see
below)
Max. dimensions
w×h×l
mm
450
160
520
200
630
200
B32673P4105+***
B32673P4155+***
B32673P4225+***
B32673P5474+***
B32673P5564+***
B32673P5684+***
B32673P5105+***
B32673P5155+***
B32673P5225+***
B32673P6334+***
B32673P6474+***
B32673P6564+***
B32673P6684+***
B32673P6105+***
B32673P6155+***
B32673P6225+***
6.0 × 15.0 × 26.5
7.0 × 16.0 × 26.5
8.5 × 16.5 × 26.5
6.0 × 15.0 × 26.5
6.0 × 15.0 × 26.5
6.0 × 15.0 × 26.5
7.0 × 16.0 × 26.5
10.5 × 16.5 × 26.5
10.5 × 20.5 × 26.5
6.0 × 15.0 × 26.5
6.0 × 15.0 × 26.5
6.0 × 15.0 × 26.5
7.0 × 16.0 × 26.5
8.5 × 16.5 × 26.5
10.5 × 18.5 × 26.5
12.0 × 22.0 × 26.5
1.0
1.5
2.2
0.47
0.56
0.68
1.0
1.5
2.2
0.33
0.47
0.56
0.68
1.0
1.5
2.2
Ammo
pack
pcs./MOQ
2720
2320
1920
2720
2720
2720
2320
1560
Reel
Untaped
pcs./MOQ
2800
2400
2000
2800
2800
2800
2400
1600
2720
2720
2720
2320
1920
1560
2800
2800
2800
2400
2000
1600
pcs./MOQ
2880
2520
2040
2880
2880
2880
2520
2160
2160
2880
2880
2880
2520
2040
2160
1800
MOQ = Minimum Order Quantity, consisting of 4 packing units.
Further E series, intermediate capacitance values and closer tolerance on request.
Composition of ordering code
+ = Capacitance tolerance code:
J = ±5%
K = ±10%
M = ±20%
Please read Cautions and warnings and
Important notes at the end of this document.
*** = Packaging code:
289 = Straight terminals, Ammo pack
189 = Straight terminals, Reel
003 = Untaped (lead length 3.2 ± 0.3 mm)
000 = Untaped (lead length 61 mm)
Page 6 of 18
B32671P ... B32673P
Power Factor Correction
Technical data
Reference standard: IEC 60384-16. All data given at T = 20 °C, otherwise is specified.
Operating temperature
range
Dissipation factor tan δ
(in 10-3) at 20 °C
(upper limit values)
Insulation resistance Rins
at 100 V or time constant
τ = CR Rins at 20 °C,
rel. humidity ≤ 65%
(minimum as-delivered
values)
Max. operating temperature Top, max
Upper category temperature Tmax
Lower category temperature Tmin
Rated temperature TR
1 kHz
1.0
10 kHz
2.5
100 kHz 25.0
+125 °C
+110 °C
55 °C
+85 °C
30 GΩ (CR ≤ 0.33 µF)
10000 s (CR > 0.33 µF)
1.4 VR, 2 s
Category voltage VC
TA (°C)
DC voltage derating
AC voltage derating
(continuous operation with TA ≤85
VC = VR
VC,RMS = VRMS
VDC or VAC at f ≤ 1 kHz)
85 <TA ≤110 VC = VR (165 Top)/80 VC,RMS = VRMS (165 Top)/80
Operating voltage Vop for
Top (°C)
DC voltage (max. hours) AC voltage (max. hours)
short operating periods
Top ≤100
Vop = 1.1 VC (1000 h) Vop = 1.0 VC,RMS (1000 h)
(VDC or VAC at f ≤ 1 kHz)
100 <Top ≤125 Vop = 1.0 VC (1000 h) Vop = 1.0 VC,RMS (1000 h)
Reliability:
Failure rate λ
24 fit (≤ 1 10-7/h) at 0.5 VR, 40 °C
Service life tSL
200000 h at 0.5 VR, 85 °C
For conversion to other operating conditions and temperatures, refer
to chapter "Reliability", page .
Failure criteria:
Total failure
Short circuit or open circuit
Failure due to variation
Capacitance change ∆C/C
> 10%
of parameters
Dissipation factor tan δ
> 4 × upper limit values
Insulation resistance Rins
< 150 MΩ (CR ≤ 0.33 µF)
Or time constant τ
< 50 s (CR ≥ 0.33 µF)
DC test voltage
Please read Cautions and warnings and
Important notes at the end of this document.
Page 7 of 18
B32671P ... B32673P
Power Factor Correction
Pulse handling capability
"dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal
voltages, expressed in V/µs.
"k0" represents the maximum permissible pulse characteristic of the waveform applied to the
capacitor, expressed in V2/µs.
Note:
The values of dV/dt and k0 provided below must not be exceeded in order to avoid damaging the
capacitor. These parameters are given for isolated pulses in such a way that the heat generated
by one pulse will be completely dissipated before applying the next pulse. For a train of pulses,
please refer to the curves of permissible AC voltage-current versus frequency.
dV/dt values
Lead spacing
VR
VRMS
V DC V AC
450
160
520
200
630
200
10 mm
15 mm
22.5 mm
dV/dt in V/µs
140
200
250
120
160
180
100
110
130
10 mm
15 mm
22.5 mm
k0 in V2/µs
126000
208000
315000
108000
166000
226000
90000
114000
163000
k0 values
Lead spacing
VR
VRMS
V DC V AC
450
160
520
200
630
200
Impedance Z versus frequency f (typical values)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 8 of 18
B32671P
Power Factor Correction
Permissible AC voltage VRMS versus frequency f (for sinusoidal waveforms TA ≤ 100 °C)
For TA > 100 °C, please use derating factor Ft.
Lead spacing 10 mm
450 V DC/160 V AC
520 V DC/200 V AC
630 V DC/200 V AC
Please read Cautions and warnings and
Important notes at the end of this document.
Page 9 of 18
B32672P
Power Factor Correction
Permissible AC voltage VRMS versus frequency f (for sinusoidal waveforms TA ≤ 100 °C)
For TA > 100 °C, please use derating factor Ft.
Lead spacing 15 mm
450 V DC/160 V AC
520 V DC/200 V AC
630 V DC/200 V AC
Please read Cautions and warnings and
Important notes at the end of this document.
Page 10 of 18
B32673P
Power Factor Correction
Permissible AC voltage VRMS versus frequency f (for sinusoidal waveforms TA ≤ 100 °C)
For TA > 100 °C, please use derating factor Ft.
Lead spacing 22.5 mm
450 V DC/160 V AC
520 V DC/200 V AC
630 V DC/200 V AC
Please read Cautions and warnings and
Important notes at the end of this document.
Page 11 of 18
B32671P
Power Factor Correction
Permissible AC current IRMS versus frequency f (for sinusoidal waveforms TA ≤ 100 °C)
For TA > 100 °C, please use derating factor Ft.
Lead spacing 10 mm
450 V DC/160 V AC
520 V DC/200 V AC
630 V DC/200 V AC
Please read Cautions and warnings and
Important notes at the end of this document.
Page 12 of 18
B32672P
Power Factor Correction
Permissible AC current IRMS versus frequency f (for sinusoidal waveforms TA ≤ 100 °C)
For TA > 100 °C, please use derating factor Ft.
Lead spacing 15 mm
450 V DC/160 V AC
520 V DC/200 V AC
630 V DC/200 V AC
Please read Cautions and warnings and
Important notes at the end of this document.
Page 13 of 18
B32673P
Power Factor Correction
Permissible AC current IRMS versus frequency f (for sinusoidal waveforms TA ≤ 100 °C)
For TA > 100 °C, please use derating factor Ft.
Lead spacing 22.5 mm
450 V DC/160 V AC
520 V DC/200 V AC
630 V DC/200 V AC
Please read Cautions and warnings and
Important notes at the end of this document.
Page 14 of 18
B32671P ... B32673P
Power Factor Correction
Maximum AC voltage (VRMS), current (IRMS) vs. frequency and temperature for TA > 100 ºC
The graphs described in the previous section for the permissible AC voltage (VRMS) or current
(IRMS) vs. frequency are given for a maximum ambient temperature TA ≤100 ºC. In case of higher
ambient temperatures (TA), the self-heating (∆T) of the component must be reduced to avoid that
temperature of the component (Top= TA + ∆T) reaches values above maximum operating
temperature.The factor FT shall be applied in the following way:
And FT is given by the following curve:
Please read Cautions and warnings and
Important notes at the end of this document.
Page 15 of 18
B32671P ... B32673P
Power Factor Correction
Testing and Standards
Test
Reference
Conditions of test
Performance
requirements
Electrical
Parameters
IEC 60384-16
Within specified limits
Robustness of
terminations
IEC 60068-2-21
Voltage proof, 1.4 VR, 1 minute
Insulation resistance, RINS
Capacitance, C
Dissipation factor, tan δ
Tensile strength (test Ua1)
Wire diameter
Tensile
force
0.5 < d1 ≤ 0.8 mm 10 N
Resistance to
soldering heat
IEC 60068-2-20, Solder bath temperature at
test Tb,
260 ± 5 °C, immersion for
method 1A
10 seconds
Capacitance and tan δ
within specified limits
∆C/C0 ≤ 2%
I∆ tan δ l ≤ 0.001
I∆C/C0 I ≤ 2%
I∆ tan δ I ≤ 0.002
RINS ≥ 50% of initial limit
Rapid change of IEC 60384-16
temperature
TA = lower category temperature
TB = upper category temperature
Five cycles, duration t = 30 min.
Vibration
IEC 60384-16
Bump
IEC 60384-16
Climatic
sequence
IEC 60384-16
Damp Heat
Steady State
IEC 60384-16
Test FC: vibration sinusoidal
No visible damage
Displacement: 0.75 mm
Accleration: 98 m/s2
Frequency: 10 Hz ... 500 Hz
Test duration: 3 orthogonal axes,
2 hours each axe
Test Eb: Total 4000 bumps with No visible damage
I∆C/C0 I ≤ 2%
390 m/s2 mounted on PCB
I∆ tan δ I ≤ 0.001
6 ms duration
RINS ≥ 50% of initial limit
Dry heat Tb / 16 h.
No visible damage
Damp heat cyclic, 1st cycle
I∆C/C0 I ≤ 2%
+ 55 °C / 24h / 95% ... 100% RH I∆ tan δ I ≤ 0.001
Cold Ta / 2h
RINS ≥ 50% of initial limit
Damp heat cyclic, 5 cycles
+ 55 °C / 24h / 95% ... 100% rh
Test Ca
No visible damage
40 °C / 93% RH / 56 days
I∆C/C0 I ≤ 3%
I∆ tan δ I ≤ 0.003
RINS ≥ 50% of initial limit
60 °C / 95% RH / 1000 hours with No visible damage
I∆C/C0 I ≤ 10%
VR, DC
I∆ tan δ I ≤ 0.004
RINS ≥ 50% of initial limit
High
temperature
high humidity
with load
Please read Cautions and warnings and
Important notes at the end of this document.
Page 16 of 18
B32671P ... B32673P
Power Factor Correction
Endurance A
85 °C/ 1.1 VR / 1000 hours
Endurance B
110 °C/ 1.1 VC / 1000 hours
Endurance C
125 °C/ 1.1 VC / 1000 hours
Endurance D
85 °C/ VR + 4 ARMS,1000 KHz/ 1000
hours
Please read Cautions and warnings and
Important notes at the end of this document.
Page 17 of 18
No visible damage
I∆C/C0 I ≤ 5%
I∆ tan δ I ≤ 0.004
RINS ≥ 50% of initial limit
No visible damage
I∆C/C0 I ≤ 10%
I∆ tan δ I ≤ 0.004
RINS ≥ 50% of initial limit
No visible damage
I∆C/C0 I ≤ 10%
I∆ tan δ I ≤ 0.004
RINS ≥ 50% of initial limit
No visible damage
I∆C/C0 I ≤ 10%
I∆ tan δ I ≤ 0.004
RINS ≥ 50% of initial limit
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application.
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar
with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of electronic components or
failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified. In customer applications
requiring a very high level of operational safety and especially in customer applications in
which the malfunction or failure of an electronic component could endanger human life or
health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by
means of suitable design of the customer application or other action taken by the customer
(e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by
third parties in the event of malfunction or failure of an electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order. We also
reserve the right to discontinue production and delivery of products. Consequently, we
cannot guarantee that all products named in this publication will always be available. The
aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association
(ZVEI).
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CeraLink, CeraPlas, CSMP, CSSP,
CTVS, DeltaCap, DigiSiMic, DSSP, FilterCap, FormFit, MiniBlue, MiniCell, MKD, MKK,
MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI,
SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, TFAP,
ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks.
Page 18 of 18