ON ADT7475ARQZ-REEL Dbcool remote thermal monitor and fan controller Datasheet

ADT7475
dBCOOLR Remote Thermal
Monitor and Fan Controller
The ADT7475 dBCOOL controller is a thermal monitor and
multiple PWM fan controller for noise−sensitive or power−sensitive
applications requiring active system cooling. The ADT7475 can drive
a fan using either a low or high frequency drive signal, monitor the
temperature of up to two remote sensor diodes plus its own internal
temperature, and measure and control the speed of up to four fans so
that they operate at the lowest possible speed for minimum acoustic
noise.
The automatic fan speed control loop optimizes fan speed for a
given temperature. The effectiveness of the system’s thermal solution
can be monitored using the THERM input. The ADT7475 also
provides critical thermal protection to the system using the
bidirectional THERM pin as an output to prevent system or
component overheating.
http://onsemi.com
MARKING
DIAGRAM
ADT7475
ARQZ
#YYWW
QSOP−16
CASE 492
Features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Controls and Monitors Up to 4 Fans
High and Low Frequency Fan Drive Signal
1 On−Chip and 2 Remote Temperature Sensors
Extended Temperature Measurement Range, Up to 191°C
Automatic Fan Speed Control Mode Controls System Cooling Based
on Measured Temperature
Enhanced Acoustic Mode Dramatically Reduces User Perception of
Changing Fan Speeds
Thermal Protection Feature via THERM Output
Monitors Performance Impact of Intel PentiumR 4 Processor
Thermal Control Circuit via THERM Input
3−Wire and 4−Wire Fan Speed Measurement
Limit Comparison of All Monitored Values
Meets SMBus 2.0 Electrical Specifications
(Fully SMBus 1.1 Compliant)
This is a Pb−Free Device
Fully RoHS Compliant
© Semiconductor Components Industries, LLC, 2009
June, 2009 − Rev. 4
1
#
= Pb−Free Package
YYWW = Date Code
PIN ASSIGNMENT
SCL 1
16
SDA
GND 2
15
PWM1/XTO
VCC 3
14
VCCP
ADT7475
13
D1+
TOP VIEW
12
D1–
11
D2+
TACH3 4
PWM2/ 5
SMBALERT
TACH1 6
TACH2 7
10
D2–
PWM3 8
9
TACH4/GPIO/THERM
SMBALERT
ORDERING INFORMATION
See detailed ordering and shipping information in the package
dimensions section on page 57 of this data sheet.
Publication Order Number:
ADT7475/D
ADT7475
SCL SDA SMBALERT
ADT7475
PWM
REGISTERS
AND
CONTROLLERS
(HF AND LF)
PWM1
PWM2
PWM3
SERIAL BUS
INTERFACE
ACOUSTIC
ENHANCEMENT
CONTROL
AUTOMATIC
FAN SPEED
CONTROL
ADDRESS
POINTER
REGISTER
TACH1
TACH2
TACH3
TACH4
PWM
CONFIGURATION
REGISTERS
FAN
SPEED
COUNTER
INTERRUPT
MASKING
PERFORMANCE
MONITORING
VCC
VCC TO ADT7475
D1+
INPUT
SIGNAL
CONDITIONING
AND
ANALOG
MULTIPLEXER
D1–
D2+
D2–
VCCP
INTERRUPT
STATUS
REGISTERS
THERMAL
PROTECTION
THERM
LIMIT
COMPARATORS
10−BIT
ADC
VALUE AND
LIMIT
REGISTERS
BAND GAP
REFERENCE
BAND GAP
TEMPERATURE
SENSOR
GND
Figure 1. Functional Block Diagram
ABSOLUTE MAXIMUM RATINGS
Parameter
Positive Supply Voltage (VCC)
Voltage on Any Input or Output Pin
Rating
Unit
3.6
V
−0.3 to +3.6
V
Input Current at Any Pin
±5
mA
Package Input Current
±20
mA
Maximum Junction Temperature (TJMAX)
150
°C
−65 to +150
°C
Storage Temperature Range
Lead Temperature, Soldering
IR Reflow Peak Temperature
Lead Temperature (Soldering, 10 sec)
°C
260
300
ESD Rating
1500
V
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
NOTE: This device is ESD sensitive. Use standard ESD precautions when handling.
THERMAL CHARACTERISTICS
Package Type
16−lead QSOP
qJA
qJC
Unit
150
39
°C/W
1. qJA is specified for the worst−case conditions, that is, a device soldered in a circuit board for surface−mount packages.
http://onsemi.com
2
ADT7475
PIN ASSIGNMENT
Pin No.
Mnemonic
1
SCL
Description
2
GND
Ground Pin.
3
VCC
Power Supply. VCC is also monitored through this pin.
4
TACH3
Digital Input (Open Drain). Fan tachometer input to measure speed of Fan 3.
5
PWM2
PWM2: Digital Output (Open Drain). Requires 10 kW typical pullup. Pulse−width modulated output to
control Fan 2 speed. Can be configured as a high or low frequency drive.
Digital Input (Open Drain). SMBus serial clock input. Requires SMBus pullup.
B
SMBALERT
SMBALERT: Digital Output (Open Drain). This pin can be reconfigured as an SMBALERT interrupt
output to signal out−of−limit conditions.
6
TACH1
Digital Input (Open Drain). Fan tachometer input to measure the speed of Fan 1.
7
TACH2
Digital Input (Open Drain). Fan tachometer input to measure the speed of Fan 2.
8
PWM3
Digital I/O (Open Drain). Pulse−width modulated output to control the speed of Fan 3 and Fan 4.
Requires 10 kW typical pullup. Can be configured as a high or low frequency drive.
9
TACH4
THERM
TACH4: Digital Input (Open Drain). Fan tachometer input to measure the speed of Fan 4.
THERM: Digital I/O (Open Drain). Alternatively, this pin can be reconfigured as a bidirectional THERM
pin that can be used to time and monitor assertions on the THERM input. For example, the pin can be
connected to the PROCHOT output of an Intel Pentium 4 processor or to the output of a trip point
temperature sensor. This pin can be used as an output to signal overtemperature conditions.
GPIO
SMBALERT
GPIO: General−Purpose Open Drain Digital I/O.
SMBALERT: Digital Output (Open Drain). This pin can be reconfigured as an SMBALERT interrupt
output to signal out−of−limit conditions.
10
D2−
Cathode Connection to Second Thermal Diode.
11
D2+
Anode Connection to Second Thermal Diode.
12
D1−
Cathode Connection to First Thermal Diode.
13
D1+
14
VCCP
Analog Input. Monitors processor core voltage (0 V to 3.0 V).
15
PWM1
Digital Output (Open Drain). Pulse−width modulated output to control Fan 1 speed. Requires 10 kW
typical pullup.
16
Anode Connection to First Thermal Diode.
B
XTO
Also functions as the output from the XNOR tree in XNOR test mode.
SDA
Digital I/O (Open Drain). SMBus bidirectional serial data. Requires 10 kW typical pullup.
http://onsemi.com
3
ADT7475
ELECTRICAL CHARACTERISTICS TA = TMIN to TMAX, VCC = VMIN to VMAX, unless otherwise noted. (Note 1)
Parameter
Conditions
Min
Typ
Max
3.0
Unit
Power Supply
3.3
3.6
V
Interface inactive, ADC active
1.5
3.0
mA
0°C ≤ TA ≤ 85°C
−40°C ≤ TA ≤ +125°C
±0.5
±1.5
±2.5
°C
1.5
±2.5
°C
Supply Voltage
Supply Current, ICC
Temperature−to−Digital Converter
Local Sensor Accuracy
Resolution
Remote Diode Sensor Accuracy
Resolution
Remote Sensor Source Current
0.25
0°C ≤ TA ≤ 85°C
−40°C ≤ TA ≤ +125°C
±0.5
0.25
High level
Low level
180
11
mA
ANALOG−TO−DIGITAL CONVERTER (INCLUDING MUX AND ATTENUATORS)
Total Unadjusted Error (TUE)
Differential Non−linearity (DNL)
8 bits
Power Supply Sensitivity
±1.5
%
±1
LSB
±0.1
%/V
Conversion Time (Voltage Input)
Averaging enabled
11
ms
Conversion Time (Local Temperature)
Averaging enabled
12
ms
Conversion Time (Remote Temperature)
Averaging enabled
38
ms
Total Monitoring Cycle Time
Averaging enabled
Averaging disabled
145
19
ms
Input Resistance
For VCCP channel
120
kW
70
FAN RPM−TO−DIGITAL CONVERTER
Accuracy
0°C ≤ TA ≤ 70°C
−40°C ≤ TA ≤ +120°C
±6
±10
Full−Scale Count
Nominal Input RPM
%
65,535
Fan count = 0xBFFF
Fan count = 0x3FFF
Fan count = 0x0438
Fan count = 0x021C
109
329
5000
10,000
RPM
OPEN−DRAIN DIGITAL OUTPUTS (PWM1 TO PWM3, XTO)
8.0
Current Sink, IOL
Output Low Voltage, VOL
IOUT = −8.0 mA
High Level Output Current, IOH
VOUT = VCC
0.1
mA
0.4
V
20
mA
0.4
V
1.0
mA
OPEN−DRAIN SERIAL DATA BUS OUTPUT (SDA)
Output Low Voltage, VOL
IOUT = −4.0 mA
High Level Output Current, IOH
VOUT = VCC
0.1
SMBus DIGITAL INPUTS (SCL, SDA)
2.0
Input High Voltage, VIH
V
Input Low Voltage, VIL
0.4
Hysteresis
500
V
mV
DIGITAL INPUT LOGIC LEVELS (TACH INPUTS)
Input High Voltage, VIH
Input Low Voltage, VIL
Maximum input voltage
Minimum input voltage
Hysteresis
2.0
3.6
0.8
−0.3
0.5
V
V
V p−p
1. All voltages are measured with respect to GND, unless otherwise specified. Typicals are at TA = 25°C and represent the most likely
parametric norm. Logic inputs accept input high voltages of up to VMAX, even when the device is operating down to VMIN. Timing
specifications are tested at logic levels of VIL = 0.8 V for a falling edge and VIH = 2.0 V for a rising edge.
2. SMBus timing specifications are guaranteed by design and are not production tested.
http://onsemi.com
4
ADT7475
ELECTRICAL CHARACTERISTICS TA = TMIN to TMAX, VCC = VMIN to VMAX, unless otherwise noted. (Note 1)
Parameter
Conditions
Min
Typ
Max
Unit
DIGITAL INPUT LOGIC LEVELS (THERM) ADTL+
0.75 x VCC
Input High Voltage, VIH
V
Input Low Voltage, VIL
0.8
V
DIGITAL INPUT CURRENT
Input High Current, IIH
VIN = VCC
±1
mA
Input Low Current, IIL
VIN = 0 V
±1
mA
5
pF
Input Capacitance, CIN
See Note 2 and Figure 2
SERIAL BUS TIMING
10
Clock Frequency, fSCLK
Glitch Immunity, tSW
400
kHz
50
ns
Bus Free Time, tBUF
4.7
ms
SCL Low Time, tLOW
4.7
ms
SCL High Time, tHIGH
4.0
SCL, SDA Rise Time, tR
SCL, SDA Fall Time, tF
50
ms
1000
ns
300
Data Setup Time, tSU: DAT
ms
250
Detect Clock Low Timeout, tTIMEOUT
Can be optionally disabled
ns
15
35
ms
1. All voltages are measured with respect to GND, unless otherwise specified. Typicals are at TA = 25°C and represent the most likely
parametric norm. Logic inputs accept input high voltages of up to VMAX, even when the device is operating down to VMIN. Timing
specifications are tested at logic levels of VIL = 0.8 V for a falling edge and VIH = 2.0 V for a rising edge.
2. SMBus timing specifications are guaranteed by design and are not production tested.
tLOW
tR
tF
tHD: STA
SCL
tHD: STA
SDA
tHD: DAT
tHIGH
tSU: STA
tSU: DAT
tBUF
P
S
S
Figure 2. Serial Bus Timing Diagram
http://onsemi.com
5
tSU: STO
P
ADT7475
0
30
–10
20
TEMPERATURE ERROR (5C)
TEMPERATURE ERROR (5C)
TYPICAL PERFORMANCE CHARACTERISTICS
–20
–30
–40
–50
10
D+ to GND
0
D+ to VCC
–10
–20
–30
–60
0
2
4
6
8
10
12
14
16
18
20
–40
22
CAPACITANCE (nF)
0
20
40
60
80
100
LEAKAGE RESISTANCE (MW)
Figure 3. Temperature Error vs. Capacitance
Between D+ and D−
Figure 4. Remote Temperature Error vs. PCB
Resistance
Figure 5. Remote Temperature Error vs.
Common−Mode Noise Frequency
Figure 6. Remote Temperature Error vs.
Differential Mode Noise Frequency
1.20
1.18
1.16
1.14
IDD (mA)
1.12
1.10
1.08
1.06
1.04
1.02
1.00
0.98
3.0
3.1
3.2
3.3
VDD (V)
3.4
3.5
3.6
Figure 7. Normal IDD vs. Power Supply
B
Figure 8. Internal Temperature Error vs. Power
Supply Noise
B
http://onsemi.com
6
ADT7475
TYPICAL PERFORMANCE CHARACTERISTICS
3.0
TEMPERATURE ERROR (5C)
2.5
2.0
1.5
1.0
0.5
0
−0.5
−1.0
−1.5
–40
–20
0
20
40
60
85
105
125
OIL BATH TEMPERATURE (5C)
Figure 9. Remote Temperature Error vs. Power
Supply Noise Frequency
Figure 10. Internal Temperature Error vs. ADT7475
Temperature
3.0
TEMPERATURE ERROR (5C)
2.5
2.0
1.5
1.0
0.5
0
–0.5
–1.0
–1.5
–2.0
–40
–20
0
20
40
60
85
105
125
OIL BATH TEMPERATURE (5C)
Figure 11. Remote Temperature Error vs. ADT7475 Temperature
http://onsemi.com
7
ADT7475
Product Description
The ADT7475 is a complete thermal monitor and multiple
fan controller for any system requiring thermal monitoring
and cooling. The device communicates with the system via
a serial system management bus. The serial bus controller
has a serial data line for reading and writing addresses and
data (Pin 16), and an input line for the serial clock (Pin 1).
All control and programming functions for the ADT7475
are performed over the serial bus. In addition, a pin can be
reconfigured as an SMBALERT output to signal
out−of−limit conditions.
specification results in irreversible damage to the ADT7475.
Signal pins (TACH/PWM) should be pulled up or clamped
to 3.6 V maximum. See the Specifications Section for more
information.
Recommended Implementation
Configuring the ADT7475 as shown in Figure 12 allows
the system designer to use the following features:
• Two PWM outputs for fan control of up−to−three fans
(the front and rear chassis fans are connected in
parallel).
• Three TACH fan speed measurement inputs.
• VCC measured internally through Pin 3.
• CPU temperature measured using the Remote 1
temperature channel.
• Ambient temperature measured through the Remote 2
temperature channel.
• Bidirectional THERM pin. This feature allows Intel
Pentium 4 PROCHOT monitoring and can function as
an overtemperature THERM output. The THERM pin
can alternatively be programmed as an SMBALERT
system interrupt output.
Quick Comparison Between ADT7473 and ADT7475
• The ADT7473 supports advanced dynamic TMIN
features while the ADT7475 does not.
• Acoustic smoothing is improved on the ADT7475.
• THERM can be selected as an output only on the
ADT7475.
• The ADT7475 has two additional configuration
registers.
• The ADT7475 has other minor register changes.
The ADT7475 is similar to the ADT7473 in that it is
powered by a supply no greater than 3.6 V. Exceeding this
ADT7475
FRONT
CHASSIS
FAN
PWM1
TACH2
TACH1
CPU FAN
PWM3
REAR
CHASSIS
FAN
D2+
TACH3
D2–
THERM
PROCHOT
AMBIENT
TEMPERATURE
CPU
D1+
SDA
D1–
SCL
SMBALERT
GND
ICH
Figure 12. ADT7475 Configuration
Serial Bus Interface
high period because a low−to−high transition when the clock
is high may be interpreted as a stop signal. The number of
data bytes that can be transmitted over the serial bus in a
single read or write operation is limited only by what the
master and slave devices can handle.
When all data bytes are read or written, stop conditions are
established. In write mode, the master pulls the data line high
during the tenth clock pulse to assert a stop condition.
In read mode, the master device overrides the acknowledge
bit by pulling the data line high during the low period before
the ninth clock pulse; this is known as no acknowledge. The
master takes the data line low during the low period before
On PCs and servers, control of the ADT7475 is carried out
using the SMBus. The ADT7475 is connected to this bus as
a slave device under the control of a master controller, which
is usually (but not necessarily) the ICH.
The ADT7475 has a fixed 7−bit serial bus address of
0101110 or 0x2E. The read/write bit must be added to get the
8−bit address (01011100 or 0x5C). Data is sent over the
serial bus in sequences of nine clock pulses, that is, eight bits
of data followed by an acknowledge bit from the slave
device. Transitions on the data line must occur during the
low period of the clock signal and remain stable during the
http://onsemi.com
8
ADT7475
address of the internal data register to write to, which is
stored in the address pointer register. The second data byte
is the data to write to the internal data register.
When reading data from a register, there are two
possibilities:
• If the ADT7475 address pointer register value is
unknown or not the desired value, it must first be set to
the correct value before data can be read from the
desired data register. This is done by performing a write
to the ADT7475 as before, but only the data byte
containing the register address is sent, because no data
is written to the register see Figure 14.
A read operation is then performed consisting of the
serial bus address; the R/W bit set to 1, followed by the
data byte read from the data register see Figure 15.
• If the address pointer register is known to be already at
the desired address, data can be read from the
corresponding data register without first writing to the
address pointer register see Figure 15.
the tenth clock pulse, and then high during the tenth clock
pulse to assert a stop condition.
Any number of bytes of data can be transferred over the
serial bus in one operation, but it is not possible to mix read
and write in one operation because the type of operation is
determined at the beginning and cannot subsequently be
changed without starting a new operation.
In the ADT7475, write operations contain either one or
two bytes, and read operations contain one byte. To write
data to one of the device data registers or read data from it,
the address pointer register must be set so that the correct
data register is addressed, and then data can be written to that
register or read from it. The first byte of a write operation
always contains an address that is stored in the address
pointer register. If data is to be written to the device, the write
operation contains a second data byte that is written to the
register selected by the address pointer register.
This write operation is shown in Figure 13. The device
address is sent over the bus, and then R/W is set to 0. This
is followed by two data bytes. The first data byte is the
1
9
9
1
SCL
SDA
0
1
0
1
1
0
1
D6
D7
R/W
START BY
MASTER
FRAME 1
SERIAL BUS ADDRESS BYTE
D4
D5
ACK. BY
ADT7475
D2
D3
D1
D0
ACK. BY
ADT7475
FRAME 2
ADDRESS POINTER REGISTER BYTE
1
9
SCL (CONTINUED)
D7
SDA (CONTINUED)
D4
D5
D6
D2
D3
D1
D0
ACK. BY
ADT7475
FRAME 3
DATA BYTE
STOP BY
MASTER
Figure 13. Writing a Register Address to the Address Pointer Register, then Writing Data to the Selected Register
1
9
9
1
SCL
SDA
0
1
0
START BY
MASTER
1
1
0
1
D7
R/W
D6
ACK. BY
ADT7475
FRAME 1
SERIAL BUS ADDRESS BYTE
D5
D4
D3
D2
D1
D0
ACK. BY
ADT7475
FRAME 2
ADDRESS POINTER REGISTER BYTE
STOP BY
MASTER
Figure 14. Writing to the Address Pointer Register Only
1
9
9
1
SCL
SDA
START BY
MASTER
0
1
0
1
1
0
1
FRAME 1
SERIAL BUS ADDRESS BYTE
D7
R/W
ACK. BY
ADT7475
D6
D5
D4
D3
9
D1
FRAME 2
DATA BYTE FROM ADT745
Figure 15. Reading Data from a Previously Selected Register
http://onsemi.com
D2
D0
NO ACK. BY STOP BY
MASTER
MASTER
ADT7475
Write Byte
It is possible to read a data byte from a data register
without first writing to the address pointer register if the
address pointer register is already at the correct value.
However, it is not possible to write data to a register without
writing to the address pointer register because the first data
byte of a write is always written to the address pointer
register.
In addition to supporting the send byte and receive byte
protocols, the ADT7475 also supports the read byte protocol
(for more information, see System Management Bus
Specifications Rev. 2.0, available from Intel).
If several read or write operations must be performed in
succession, the master can send a repeat start condition
instead of a stop condition to begin a new operation.
In this operation, the master device sends a command byte
and one data byte to the slave device as follows:
1. The master device asserts a start condition on
SDA.
2. The master sends the 7−bit slave address followed
by the write bit (low).
3. The addressed slave device asserts ACK on SDA.
4. The master sends a command code.
5. The slave asserts ACK on SDA.
6. The master sends a data byte.
7. The slave asserts ACK on SDA.
8. The master asserts a stop condition on SDA and
the transaction ends.
The byte write operation is shown in Figure 17.
Write Operations
1
The SMBus specification defines several protocols for
different types of read and write operations. The ones used
in the ADT7475 are discussed in this section. The following
abbreviations are used in the diagrams:
S—Start
P—Stop
R—Read
W—Write
A—Acknowledge
A—No acknowledge
The ADT7475 uses the following SMBus write protocols.
S
3
SLAVE
W A
ADDRESS
4
5 6
REGISTER
ADDRESS
A P
4
5
REGISTER
ADDRESS
A
6
7
8
DATA A P
Read Operations
The ADT7475 uses the following SMBus read protocols.
Receive Byte
This operation is useful when repeatedly reading a single
register. The register address must be set up previously. In
this operation, the master device receives a single byte from
a slave device as follows:
1. The master device asserts a start condition on
SDA.
2. The master sends the 7−bit slave address followed
by the read bit (high).
3. The addressed slave device asserts ACK on SDA.
4. The master receives a data byte.
5. The master asserts NO ACK on SDA.
6. The master asserts a stop condition on SDA, and
the transaction ends.
In the ADT7475, the receive byte protocol is used to read
a single byte of data from a register whose address has
previously been set by a send byte or write byte operation.
This operation is shown in Figure 18.
In this operation, the master device sends a single
command byte to a slave device as follows:
1. The master device asserts a start condition on
SDA.
2. The master sends the 7−bit slave address followed
by the write bit (low).
3. The addressed slave device asserts ACK on SDA.
4. The master sends a command code.
5. The slave asserts ACK on SDA.
6. The master asserts a stop condition on SDA and
the transaction ends.
For the ADT7475, the send byte protocol is used to write
a register address to RAM for a subsequent single−byte read
from the same address. This operation is shown in Figure 16.
2
3
Figure 17. Single−Byte Write to a Register
Send Byte
1
2
SLAVE
S ADDRESS W A
1
2
3
SLAVE
S ADDRESS R A
4
5 6
DATA
A P
Figure 18. Single−Byte Read from a Register
Figure 16. Setting a Register Address for
Subsequent Read
Alert Response Address
If the master is required to read data from the register
immediately after setting up the address, it can assert a repeat
start condition immediately after the final ACK and carry
out a single−byte read without asserting an intermediate stop
condition.
Alert response address (ARA) is a feature of SMBus
devices that allows an interrupting device to identify itself
to the host when multiple devices exist on the same bus.
The SMBALERT output can be used as either an interrupt
output or an SMBALERT. One or more outputs can be
http://onsemi.com
10
ADT7475
connected to a common SMBALERT line connected to the
master. If a device’s SMBALERT line goes low, the
following events occur:
1. SMBALERT is pulled low.
2. The master initiates a read operation and sends the
alert response address (ARA = 0001 100). This
general call address must not be used as a specific
device address.
3. The device whose SMBALERT output is low
responds to the alert response address, and the
master reads its device address. The address of the
device is now known and can be interrogated in
the usual way.
4. If more than one device’s SMBALERT output is
low, the one with the lowest device address has
priority in accordance with normal SMBus
arbitration.
5. Once the ADT7475 has responded to the alert
response address, the master must read the status
registers, and the SMBALERT is cleared only if
the error condition has gone away.
allow for the tolerance of the supply voltage, the ADC
produces an output of 3/4 full scale (decimal 768 or 300 hex)
for the nominal input voltage and so has adequate headroom
to deal with overvoltages.
Input Circuitry
The internal structure for the VCCP analog input is shown
in Figure 19. The input circuit consists of an input protection
diode, an attenuator, and a capacitor to form a first−order,
low−pass filter that gives the input immunity to high
frequency noise.
VCCP
17.5kW
52.5kW
35pF
Figure 19. Structure of Analog Inputs
Voltage Measurement Registers
Register 0x21, VCCP Reading = 0x00 default
Register 0x22, VCC Reading = 0x00 default
VCCP Limit Registers
SMBus Timeout
Associated with the VCCP measurement channel is a high
and low limit register. Exceeding the programmed high or
low limit causes the appropriate status bit to be set.
Exceeding either limit can also generate SMBALERT
interrupts.
Register 0x46, VCCP Low Limit = 0x00 default
Register 0x47, VCCP High Limit = 0xFF default
Table 2 shows the input ranges of the analog inputs and
output codes of the 10−bit ADC.
When the ADC is running, it samples and converts a
voltage input in 711 ms and averages 16 conversions to
reduce noise; a measurement takes nominally 11.38 ms.
The ADT7475 includes an SMBus timeout feature. If
there is no SMBus activity for 35 ms, the ADT7475 assumes
that the bus is locked and releases the bus. This prevents the
device from locking or holding the SMBus expecting data.
Some SMBus controllers cannot handle the SMBus timeout
feature, so it can be disabled.
Configuration Register 1 (0x40)
Bit 6 TODIS = 0; SMBus timeout enabled (default).
Bit 6 TODIS = 1; SMBus timeout disabled.
Virus Protection
To prevent rogue programs or viruses from accessing
critical ADT7475 register settings, the lock bit can be set.
Setting Bit 1 of Configuration Register 1 (0x40) sets the lock
bit and locks critical registers. In this mode, certain registers
can no longer be written to until the ADT7475 is powered
down and powered up again. For more information on which
registers are locked, see the Register Tables section.
Extended Resolution Registers
Voltage measurements can be made with higher accuracy
using the extended resolution registers (0x76 and 0x77).
Whenever the extended resolution registers are read, the
corresponding data in the voltage measurement registers is
locked until their data is read. That is, if extended resolution
is required, then the extended resolution register must be
read first, immediately followed by the appropriate voltage
measurement register.
Voltage Measurement Input
The ADT7475 has one external voltage measurement
channel. It can also measure its own supply voltage, VCC.
Pin 14 can measure VCCP. The VCC supply voltage
measurement is carried out through the VCC pin (Pin 3). The
VCCP input can be used to monitor a chipset supply voltage
in computer systems.
Additional ADC Functions for Voltage Measurements
A number of other functions are available on the
ADT7475 to offer the system designer increased flexibility.
Turn−Off Averaging
For each voltage measurement read from a value register,
16 readings have been made internally, and the
results averaged, before being placed into the value register.
For instances where faster conversions are needed, setting
Bit 4 of Configuration Register 2 (0x73) turns averaging off.
Analog−to−Digital Converter
All analog inputs are multiplexed into the on−chip,
successive approximation, analog−to−digital converter.
This has a resolution of 10 bits. The basic input range is 0 V
to 2.25 V, but the input has built−in attenuators to allow
measurement of VCCP without any external components. To
http://onsemi.com
11
ADT7475
This effectively gives a reading 16 times faster (711 ms), but
the reading may be noisier.
Table 1. Single−Channel ADC Conversion
Register 0x55, Bits [7:5]
Bypass Voltage Input Attenuator
Setting Bit 5 of Configuration Register 2 (0x73) removes
the attenuation circuitry from the VCCP input. This allows
the user to directly connect external sensors or to rescale the
analog voltage measurement inputs for other applications.
The input range of the ADC without the attenuators is 0 V
to 2.25 V.
Channel Selected
001
VCCP
010
VCC
101
Remote 1 Temperature
110
Local Temperature
111
Remote 2 Temperature
Configuration Register 2 (0x73)
Single−Channel ADC Conversion
Bit 4 = 1; averaging off.
Bit 5 = 1; bypass input attenuators.
Bit 6 = 1; single−channel convert mode.
Setting Bit 6 of Configuration Register 2 (0x73) places the
ADT7475 into single−channel ADC conversion mode. In
this mode, the ADT7475 can be made to read a single
voltage channel only. If the internal ADT7475 clock is used,
the selected input is read every 711 ms. The appropriate ADC
channel is selected by writing to Bits [7:5] of the TACH1
minimum high byte register (0x55).
TACH1 Minimum High Byte (0x55)
Bits [7:5] select the ADC channel for single−channel
convert mode.
Table 2. 10−Bit ADC Output Code vs. VIN
ADC Output
VCC (3.3 VIN) (Note 1)
VCCP
Decimal
Binary (10 Bits)
<0.0042
<0.00293
0
00000000 00
0.0042 to 0.0085
0.0293 to 0.0058
1
00000000 01
0.0085 to 0.0128
0.0058 to 0.0087
2
00000000 10
0.0128 to 0.0171
0.0087 to 0.0117
3
00000000 11
0.0171 to 0.0214
0.0117 to 0.0146
4
00000001 00
0.0214 to 0.0257
0.0146 to 0.0175
5
00000001 01
0.0257 to 0.0300
0.0175 to 0.0205
6
00000001 10
0.0300 to 0.0343
0.0205 to 0.0234
7
00000001 11
0.0343 to 0.0386
0.0234 to 0.0263
8
00000010 00
−
−
−
−
1.100 to 1.1042
0.7500 to 0.7529
256 (1/4 scale)
01000000 00
−
−
−
−
2.200 to 2.2042
1.5000 to 1.5029
512 (1/2 scale)
10000000 00
−
−
−
−
3.300 to 3.3042
2.2500 to 2.2529
768 (3/4 scale)
11000000 00
−
−
−
−
4.3527 to 4.3570
2.9677 to 2.9707
1013
11111101 01
4.3570 to 4.3613
2.9707 to 2.9736
1014
11111101 10
4.3613 to 4.3656
2.9736 to 2.9765
1015
11111101 11
4.3656 to 4.3699
2.9765 to 2.9794
1016
11111110 00
4.3699 to 4.3742
2.9794 to 2.9824
1017
11111110 01
4.3742 to 4.3785
2.9824 to 2.9853
1018
11111110 10
4.3785 to 4.3828
2.9853 to 2.9882
1019
11111110 11
4.3828 to 4.3871
2.9882 to 2.9912
1020
11111111 00
4.3871 to 4.3914
2.9912 to 2.9941
1021
11111111 01
4.3914 to 4.3957
2.9941 to 2.9970
1022
11111111 10
>4.3957
>2.9970
1023
11111111 11
1. The VCC output codes listed assume that VCC is 3.3 V and that VCC should never exceed 3.6 V.
http://onsemi.com
12
ADT7475
Temperature Measurement Method
However, this exceeds the operating temperature range of
the device, so local temperature measurements outside the
ADT7475 operating temperature range are not possible.
Local Temperature Measurement
The ADT7475 contains an on−chip band gap temperature
sensor whose output is digitized by the on−chip, 10−bit
ADC. The 8−bit MSB temperature data is stored in the
temperature registers (0x25, 0x26, and 0x27). Because both
positive and negative temperatures can be measured, the
temperature data is stored in Offset 64 format or twos
complement format, as shown in Table 3 and Table 4.
Theoretically, the temperature sensor and ADC can
measure temperatures from −128°C to +127°C (or −64°C to
+191°C in the extended temperature range) with a
resolution of 0.25°C.
Remote Temperature Measurement
The ADT7475 can measure the temperature of two remote
diode sensors or diode−connected transistors connected to
Pin 10 and Pin 11 or to Pin 12 and Pin 13.
The forward voltage of a diode or diode−connected
transistor operated at a constant current exhibits a negative
temperature coefficient of about –2 mV/°C. Because the
absolute value of VBE varies from device to device and
individual calibration is required to null this out, the
technique is unsuitable for mass production.
VDD
CPU
I
REMOTE
SENSING
TRANSISTOR
THERMDA
D+
THERMDC
D–
NyI
IBIAS
VOUT+
TO ADC
BIAS
DIODE
LOW−PASS FILTER
fC = 65kHz
VOUT–
Figure 20. Signal Conditioning for Remote Diode Temperature Sensors
To measure DVBE, the sensor is switched between
operating currents of I and N x I. The resulting waveform is
passed through a 65 kHz low−pass filter to remove noise and
to a chopper stabilized amplifier that performs the functions
of amplification and rectification of the waveform to
produce a dc voltage proportional to DVBE. This voltage is
measured by the ADC to give a temperature output in
10−bit, twos complement format. To further reduce the
effects of noise, digital filtering is performed by averaging
the results of 16 measurement cycles.
A remote temperature measurement takes nominally
38 ms. The results of remote temperature measurements are
stored in 10−bit, twos complement format, as shown in
Table 3. The extra resolution for the temperature
measurements is held in the Extended Resolution Register 2
(0x77). This gives temperature readings with a resolution of
0.25°C.
The technique used in the ADT7475 is to measure the
change in VBE when the device is operated at two different
currents.
This is given by:
DV BE + kTńq
In(N)
(eq. 1)
where:
k is Boltzmann’s constant.
q is the charge on the carrier.
T is the absolute temperature in Kelvin.
N is the ratio of the two currents.
Figure 20 shows the input signal conditioning used to
measure the output of a remote temperature sensor. This
figure shows the external sensor as a substrate transistor,
provided for temperature monitoring on some
microprocessors. It could also be a discrete transistor such
as a 2N3904/2N3906.
If a discrete transistor is used, the collector is not grounded
and should be linked to the base. If a PNP transistor is used,
the base is connected to the D input and the emitter to the
D+ input. If an NPN transistor is used, the emitter is
connected to the D input and the base to the D+ input.
Figure 21 and Figure 22 show how to connect the ADT7475
to an NPN or PNP transistor for temperature measurement.
To prevent ground noise from interfering with the
measurement, the more negative terminal of the sensor is not
referenced to ground but is biased above ground by an
internal diode at the D input.
Noise Filtering
For temperature sensors operating in noisy environments,
previous practice was to place a capacitor across the D+ pin
and D− pin to help combat the effects of noise. However,
large capacitance’s affect the accuracy of the temperature
measurement, leading to a recommended maximum
capacitor value of 1000 pF.
This capacitor reduces the noise but does not eliminate it.
Sometimes, this sensor noise is a problem in a very noisy
environment. In most cases, a capacitor is not required
http://onsemi.com
13
ADT7475
because differential inputs, by their very nature, have a high
immunity to noise.
calculate it. This offset can be programmed to the offset
register. If more than one offset must be considered, the
algebraic sum of these offsets must be programmed to
the offset register.
If a discrete transistor is used with the ADT7475, the best
accuracy is obtained by choosing devices according to the
following criteria:
• Base−emitter voltage greater than 0.25 V at 11 mA, at
the highest operating temperature.
• Base−emitter voltage less than 0.95 V at 180 mA, at the
lowest operating temperature.
• Base resistance less than 100 W.
• Small variation in hFE (approximately 50 to 150) that
indicates tight control of VBE characteristics.
Transistors, such as 2N3904, 2N3906, or equivalents in
SOT−23 packages, are suitable devices to use.
ADT7475
2N3904
NPN
D+
D–
Figure 21. Measuring Temperature Using an
NPN Transistor
ADT7475
D+
2N3906
PNP
D–
Table 3. Twos Complement Temperature Data Format
Figure 22. Measuring Temperature Using a
PNP Transistor
Temperature
Factors Affecting Diode Accuracy
Remote Sensing Diode
The ADT7475 is designed to work with either substrate
transistors built into processors or with discrete transistors.
Substrate transistors are generally PNP types with the
collector connected to the substrate. Discrete types can be
either PNP or NPN transistors connected as a diode
(base−shorted to the collector). If an NPN transistor is used,
the collector and base are connected to D+ and the emitter
to D−. If a PNP transistor is used, the collector and base are
connected to D− and the emitter is connected to D+.
To reduce the error due to variations in both substrate and
discrete transistors, a number of factors should be taken into
consideration:
• The ideality factor, nf, of the transistor is a measure of
the deviation of the thermal diode from ideal behavior.
The ADT7475 is trimmed for an nf value of 1.008. Use
the following equation to calculate the error introduced
at a temperature, T (°C), when using a transistor whose
nf does not equal 1.008. See the processor data sheet for
the nf values.
DT + ǒn f * 1.008Ǔ
•
ǒ273.15 k ) TǓ
Digital Output (10−Bit) (Note 1)
–128°C
1000 0000 00 (diode fault)
–63°C
1100 0001 00
–50°C
1100 1110 00
–25°C
1110 0111 00
–10°C
1111 0110 00
0°C
0000 0000 00
10.25°C
0000 1010 01
25.5°C
0001 1001 10
50.75°C
0011 0010 11
75°C
0100 1011 00
100°C
0110 0100 00
125°C
0111 1101 00
127°C
0111 1111 00
1. Bold numbers denote 2 LSBs of measurement in the Extended
Resolution Register 2 (0x77) with 0.25°C resolution.
Table 4. Extended Range, Temperature Data Format
Temperature
(eq. 2)
To factor this in, the user can write the DT value to the
offset register. The ADT7475 automatically adds it
to or subtracts it from the temperature measurement.
Some CPU manufacturers specify the high and low
current levels of the substrate transistors. The high
current level of the ADT7475, IHIGH, is 180 mA and the
low level current, ILOW, is 11 mA. If the ADT7475
current levels do not match the current levels specified
by the CPU manufacturer, it might be necessary to
remove an offset. The CPU’s data sheet advises
whether this offset needs to be removed and how to
Digital Output (10−Bit) (Note 1)
–64°C
0000 0000 00 (diode fault)
–63°C
0000 0001 00
–1°C
0011 1111 00
0°C
0100 0000 00
1°C
0100 0001 00
10°C
0100 1010 00
25°C
0101 1001 00
50°C
0111 0010 00
75°C
1000 1001 00
100°C
1010 0100 00
125°C
1011 1101 00
191°C
1111 1111 00
1. Bold numbers denote 2 LSBs of measurement in the Extended
Resolution Register 2 (0x77) with 0.25°C resolution.
http://onsemi.com
14
ADT7475
Nulling Out Temperature Errors
high or low limit causes the appropriate status bit to be set.
Exceeding either limit can also generate SMBALERT
interrupts (depending on the way the interrupt mask register
is programmed and assuming that SMBALERT is set as an
output on the appropriate pin).
Register 0x4E, Remote 1 Temperature Low Limit = 0x81
default
Register 0x4F, Remote 1 Temperature High Limit = 0x7F
default
Register 0x50, Local Temperature Low Limit = 0x81 default
Register 0x51, Local Temperature High Limit = 0x7F default
Register 0x52, Remote 2 Temperature Low Limit = 0x81
default
Register 0x53, Remote 2 Temperature High Limit = 0x7F
default
As CPUs run faster, it is more difficult to avoid high
frequency clocks when routing the D+/D– traces around a
system board. Even when recommended layout guidelines
are followed, some temperature errors can still be
attributable to noise coupled onto the D+/D– lines. Constant
high frequency noise usually attenuates, or increases,
temperature measurements by a linear, constant value.
The ADT7475 has two temperature offset registers, Register
0x70 and Register 0x72, for the Remote 1 and Remote 2
temperature channels. By doing a one−time calibration of
the system, the user can determine the offset caused by system
board noise and null it out using the offset registers. The offset
registers automatically add a twos complement 8−bit reading
to every temperature measurement.
Changing Bit 1 of Configuration Register 5 (0x7C)
changes the resolution and therefore the range of the
temperature offset as either having a range of –63°C to
+127°C, with a resolution of 1°C, or having a range of −63°C
to +64°C, with a resolution of 0.5°C. This temperature offset
can be used to compensate for linear temperature errors
introduced by noise.
Reading Temperature from the ADT7475
It is important to note that temperature can be read from
the ADT7475 as an 8−bit value (with 1°C resolution) or as
a 10−bit value (with 0.25°C resolution). If only 1°C
resolution is required, the temperature readings can be read
back at any time and in no particular order.
If the 10−bit measurement is required, this involves a
two−register read for each measurement. The Extended
Resolution Register 2 (0x77) should be read first. This
causes all temperature reading registers to be frozen until all
temperature reading registers have been read from. This
prevents an MSB reading from being updated while its two
LSBs are being read and vice versa.
Temperature Offset Registers
Register 0x70, Remote 1 Temperature Offset = 0x00
(0°C default)
Register 0x71, Local Temperature Offset = 0x00
(0°C default)
Register 0x72, Remote 2 Temperature Offset = 0x00
(0°C default)
Additional ADC Functions for Temperature
Measurement
ADT7463/ADT7475 Backwards Compatible Mode
By setting Bit 0 of Configuration Register 5 (0x7C), all
temperature measurements are stored in the zone temperature
value registers (0x25, 0x26, and 0x27) in twos complement
in the range −128°C to +127°C. The temperature limits must
be reprogrammed in twos complement.
If a twos complement temperature below −128°C is
entered, the temperature is clamped to −128°C. In this mode,
the diode fault condition remains −128°C = 1000 0000, while
in the extended temperature range (−64°C to +191°C), the
fault condition is represented by −64°C = 0000 0000.
A number of other functions are available on the
ADT7475 to offer the system designer increased flexibility.
Turn−Off Averaging
For each temperature measurement read from a value
register, 16 readings have actually been made internally, and
the results averaged, before being placed into the value
register. Sometimes it is necessary to take a very fast
measurement. Setting Bit 4 of Configuration Register 2
(0x73) turns averaging off. The default round−robin cycle
time takes 146.5 ms.
Temperature Measurement Registers
Register 0x25, Remote 1 Temperature
Register 0x26, Local Temperature
Register 0x27, Remote 2 Temperature
Register 0x77, Extended Resolution 2 = 0x00 default
Bits [7:6] TDM2, Remote 2 Temperature LSBs.
Bits [5:4] LTMP, Local Temperature LSBs.
Bits [3:2] TDM1, Remote 1 Temperature LSBs.
Table 5. Conversion Time with Averaging Disabled
Temperature Measurement Limit Registers
Channel
Measurement Time (ms)
Voltage Channels
0.7
Remote Temperature 1
7
Remote Temperature 2
7
Local Temperature
1.3
When Bit 7 of Configuration Register 6 (0x10) is set, the
default round−robin cycle time increases to 240 ms.
Associated with each temperature measurement channel
are high and low limit registers. Exceeding the programmed
http://onsemi.com
15
ADT7475
THERM can be disabled on specific temperature channels
using Bits [7:5] of Configuration Register 5 (0x7C).
THERM can also be disabled by:
• In Offset 64 mode, writing −64°C to the appropriate
THERM Temperature Limit.
• In twos complement mode, writing −128°C to the
appropriate THERM Temperature Limit.
Table 6. Conversion Time with Averaging Enabled
Channel
Measurement Time (ms)
Voltage Channels
11
Remote Temperature 1
39
Remote Temperature 2
39
Local Temperature
12
Single−Channel ADC Conversions
Limits, Status Registers, and Interrupts
Setting Bit 6 of Configuration Register 2 (0x73) places the
ADT7475 into single−channel ADC conversion mode. In
this mode, the ADT7475 can be made to read a single
temperature channel only. The appropriate ADC channel is
selected by writing to Bits [7:5] of the TACH1 minimum
high byte register (0x55).
Limit Values
Associated with each measurement channel on the
ADT7475 are high and low limits. These can form the basis of
system status monitoring; a status bit can be set for any
out−of−limit condition and detected by polling the device.
Alternatively, SMBALERT interrupts can be generated to flag
out−of−limit conditions to a processor or microcontroller.
Table 7. Programming Single−Channel ADC Mode for
Temperatures
Register 0x55, Bits [7:5]
8−Bit Limits
Channel Selected
The following is a list of 8−bit limits on the ADT7475.
101
Remote 1 Temperature
110
Local Temperature
Voltage Limit Registers
111
Remote 2 Temperature
Register 0x46, VCCP Low Limit = 0x00 default
Register 0x47, VCCP High Limit = 0xFF default
Register 0x48, VCC Low Limit = 0x00 default
Register 0x49, VCC High Limit = 0xFF default
Configuration Register 2 (0x73)
Bit 4 = 1, averaging off.
Bit 6 = 1, single−channel convert mode.
Temperature Limit Registers
TACH1 Minimum High Byte Register ( 0x55)
Register 0x4E, Remote 1 Temperature Low Limit = 0x81
default
Register 0x4F, Remote 1 Temperature High Limit = 0x7F
default
Register 0x6A, Remote 1 THERM Temperature
Limit = 0x64 default
Register 0x50, Local Temperature Low Limit = 0x81
default
Register 0x51, Local Temperature High Limit = 0x7F
default
Register 0x6B, Local THERM Temperature Limit = 0x64
default
Register 0x52, Remote 2 Temperature Low Limit = 0x81
default
Register 0x53, Remote 2 Temperature High Limit = 0x7F
default
Register 0x6C, Remote 2 THERM Temperature
Limit = 0x64 default
Bits [7:5] select the ADC channel for single−channel
convert mode.
Overtemperature Events
Overtemperature events on any of the temperature
channels can be detected and dealt with automatically in
automatic fan speed control mode. Register 0x6A to
Register 0x6C are the THERM temperature limit registers.
When a temperature exceeds its THERM temperature limit,
all PWM outputs run at the maximum PWM duty cycle
(Register 0x38, Register 0x39, and Register 0x3A).
This effectively runs the fans at the fastest allowed speed.
The fans run at this speed until the temperature drops
below THERM minus hysteresis. This can be disabled by
setting the boost bit in Configuration Register 3 (0x78),
Bit 2. The hysteresis value for the THERM temperature
limit is the value programmed into Register 0x6D and
Register 0x6E (hysteresis registers). The default hysteresis
value is 4°C.
THERM LIMIT
THERM Limit Register
Register 0x7A, THERM Timer Limit = 0x00 default
HYSTERESIS (5C)
TEMPERATURE
FANS
16−Bit Limits
The fan TACH measurements are 16−bit results. The fan
TACH limits are also 16 bits, consisting of a high byte and
low byte. Because fans running under speed or stalled are
normally the only conditions of interest, only high limits
exist for fan TACHs. Because the fan TACH period is
100%
Figure 23. THERM Temperature Limit Operation
http://onsemi.com
16
ADT7475
is a derivative of the ADT7467. As a result, the total
conversion time in the ADT7475 is the same as the total
conversion time of the ADT7467.
Fan TACH measurements are made in parallel and are not
synchronized with the analog measurements in any way.
actually being measured, exceeding the limit indicates a
slow or stalled fan.
Fan Limit Registers
Register 0x54, TACH1 Minimum Low Byte = 0xFF default
Register 0x55, TACH1 Minimum High Byte = 0xFF default
Register 0x56, TACH2 Minimum Low Byte = 0xFF default
Register 0x57, TACH2 Minimum High Byte = 0xFF default
Register 0x58, TACH3 Minimum Low Byte = 0xFF default
Register 0x59, TACH3 Minimum High Byte = 0xFF default
Register 0x5A, TACH4 Minimum Low Byte = 0xFF default
Register 0x5B, TACH4 Minimum High Byte = 0xFF default
Interrupt Status Registers
The results of limit comparisons are stored in Interrupt
Status Register 1 and Interrupt Status Register 2. The status
register bit for each channel reflects the status of the last
measurement and limit comparison on that channel. If a
measurement is within limits, the corresponding status register
bit is cleared to 0. If the measurement is out−of−limits, the
corresponding status register bit is set to 1.
The state of the various measurement channels can be
polled by reading the status registers over the serial bus. In
Bit 7 (OOL) of Interrupt Status Register 1 (0x41), 1 means
that an out−of−limit event has been flagged in Interrupt
Status Register 2. This means that the user needs only to read
Interrupt Status Register 2 when this bit is set. Alternatively,
Pin 5 or Pin 9 can be configured as an SMBALERT output.
This automatically notifies the system supervisor of an
out−of−limit condition. Reading the status registers clears
the appropriate status bit as long as the error condition that
caused the interrupt has cleared.
Status register bits are sticky. Whenever a status bit is set,
indicating an out−of−limit condition, it remains set even if
the event that caused it has gone away (until read). The only
way to clear the status bit is to read the status register after
the event has gone away. Interrupt status mask registers
(0x74 and 0x75) allow individual interrupt sources to be
masked from causing an SMBALERT. However, if one of
these masked interrupt sources goes out−of−limit, its
associated status bit is set in the interrupt status registers.
Out−of−Limit Comparisons
Once all limits have been programmed, the ADT7475 can
be enabled for monitoring. The ADT7475 measures all
voltage and temperature measurements in round−robin
format and sets the appropriate status bit for out−of−limit
conditions. TACH measurements are not part of this
round−robin cycle. Comparisons are done differently,
depending on whether the measured value is being
compared to a high or low limit.
High Limit > Comparison Performed
Low Limit ≤ Comparison Performed
Voltage and temperature channels use a window
comparator for error detecting and, therefore, have high and
low limits. Fan speed measurements use only a low limit.
This fan limit is needed only in manual fan control mode.
Analog Monitoring Cycle Time
The analog monitoring cycle begins when a 1 is written to
the start bit (Bit 0) of Configuration Register 1 (0x40).
By default, the ADT7475 powers up with this bit set. The
ADC measures each analog input in turn and, as each
measurement is completed, the result is automatically
stored in the appropriate value register. This round−robin
monitoring cycle continues unless disabled by writing a 0 to
Bit 0 of Configuration Register 1.
As the ADC is normally left to free−run in this manner, the
time taken to monitor all the analog inputs is normally not
of interest, because the most recently measured value of any
input can be read out at any time.
For applications where the monitoring cycle time is
important, it can easily be calculated. The total number of
channels measured is
• One dedicated supply voltage input (VCCP pin)
• Supply voltage (VCC pin)
• Local temperature
• Two remote temperatures
As mentioned previously, the ADC performs round−robin
conversions. The total monitoring cycle time for averaged
voltage and temperature monitoring is 146 ms. The total
monitoring cycle time for voltage and temperature
monitoring with averaging disabled is 19 ms. The ADT7475
Interrupt Status Register 1 (0x41)
Bit 7 (OOL) = 1, denotes that a bit in Status Register 2 is set
and that Interrupt Status Register 2 should be read.
Bit 6 (R2T) = 1, Remote 2 temperature high or low limit has
been exceeded.
Bit 5 (LT) = 1, local temperature high or low limit has been
exceeded.
Bit 4 (R1T) = 1, Remote 1 temperature high or low limit has
been exceeded.
Bit 2 (VCC) = 1, VCC high or low limit has been exceeded.
Bit 1 (VCCP) = 1, VCCP high or low limit has been exceeded.
Interrupt Status Register 2 (0x42)
Bit 7 (D2) = 1, indicates an open or short on D2+/D2– inputs.
Bit 6 (D1) = 1, indicates an open or short on D1+/D1– inputs.
Bit 5 (F4P) = 1, indicates that Fan 4 has dropped below
minimum speed. Alternatively, indicates that the THERM
limit has been exceeded, if the THERM function is used.
Bit 4 (FAN3) = 1, indicates that Fan 3 has dropped below
minimum speed.
http://onsemi.com
17
ADT7475
Bit 3 (FAN2) = 1, indicates that Fan 2 has dropped below
minimum speed.
Bit 2 (FAN1) = 1, indicates that Fan 1 has dropped below
minimum speed.
Bit 1 (OVT) = 1, indicates that a THERM overtemperature
limit has been exceeded.
HIGH LIMIT
TEMPERATURE
SMBALERT Interrupt Behavior
The ADT7475 can be polled for status, or an SMBALERT
interrupt can be generated for out−of−limit conditions. Note
how the SMBALERT output and status bits behave when
writing interrupt handler software.
TEMP BACK IN LIMIT
(STATUS BIT STAYS SET)
SMBALERT
HIGH LIMIT
INTERRUPT
MASK BIT SET
INTERRUPT MASK BIT CLEARED
(SMBALERT RE−ARMED)
Figure 25. How Masking the Interrupt Source Affects
SMBALERT Output
TEMPERATURE
Masking Interrupt Sources
Interrupt Mask Register 1 (0x74) and Interrupt Mask
Register 2 (0x75) allow individual interrupt sources to be
masked out to prevent SMBALERT interrupts. Note that
masking an interrupt source prevents only the SMBALERT
output from being asserted; the appropriate status bit is set
normally.
CLEARED ON READ
(TEMP BELOW LIMIT)
STICKY
STATUS BIT
SMBALERT
CLEARED ON READ
(TEMP BELOW LIMIT)
STICKY
STATUS BIT
TEMP BACK IN LIMIT
(STATUS BIT STAYS SET)
Figure 24. SMBALERT and Status Bit Behavior
Interrupt Mask Register 1 (0x74)
Figure 24 shows how the SMBALERT output and sticky
status bits behave. Once a limit is exceeded, the
corresponding status bit is set to 1. The status bit remains set
until the error condition subsides and the status register is
read. The status bits are referred to as sticky because they
remain set until read by software. This ensures that an
out−of−limit event cannot be missed if software is polling
the device periodically. Note that the SMBALERT output
remains low for the entire duration that a reading is
out−of−limit and until the interrupt status register has been
read. This has implications for how software handles the
interrupt.
Bit 7 (OOL) = 1, masks SMBALERT for any alert condition
flagged in Interrupt Status Register 2.
Bit 6 (R2T) = 1, masks SMBALERT for Remote 2
Temperature.
Bit 5 (LT) = 1, masks SMBALERT for Local Temperature.
Bit 4 (R1T) = 1, masks SMBALERT for Remote 1
Temperature.
Bit 2 (VCC) = 1, masks SMBALERT for VCC Channel.
Bit 0 (VCCP) = 1, masks SMBALERT for VCCP Channel.
Interrupt Mask Register 2 (0x75)
Bit 7 (D2) = 1, masks SMBALERT for Diode 2 errors.
Bit 6 (D1) = 1, masks SMBALERT for Diode 1 errors.
Bit 5 (F4P) = 1, masks SMBALERT for Fan 4 failure.
If the TACH4 pin is being used as the THERM input, this bit
masks SMBALERT for a THERM event.
Bit 4 (FAN3) = 1, masks SMBALERT for Fan 3.
Bit 3 (FAN2) = 1, masks SMBALERT for Fan 2.
Bit 2 (FAN1) = 1, masks SMBALERT for Fan 1.
Bit 1 (OVT) = 1, masks SMBALERT for overtemperature
(exceeding THERM limits).
Handling SMBALERT Interrupts
To prevent the system from being tied up servicing
interrupts, it is recommended to handle the SMBALERT
interrupt as follows:
1. Detect the SMBALERT assertion.
2. Enter the interrupt handler.
3. Read the status registers to identify the interrupt
source.
4. Mask the interrupt source by setting the
appropriate mask bit in the interrupt mask registers
(0x74 and 0x75).
5. Take the appropriate action for a given interrupt
source.
6. Exit the interrupt handler.
7. Periodically poll the status registers. If the
interrupt status bit has cleared, reset the
corresponding interrupt mask bit to 0. This causes
the SMBALERT output and status bits to behave
as shown in Figure 25.
Enabling the SMBALERT Interrupt Output
The SMBALERT interrupt function is disabled by
default. Pin 5 or Pin 9 can be reconfigured as an
SMBALERT output to signal out−of−limit conditions.
http://onsemi.com
18
ADT7475
THERM Timer
Table 8. Configuring Pin 5 as SMBALERT Output
Register
The ADT7475 has an internal timer to measure THERM
assertion time. For example, the THERM input can be
connected to the PROCHOT output of a Pentium 4 CPU to
measure system performance. The THERM input can also be
connected to the output of a trip point temperature sensor.
The timer is started on the assertion of the ADT7475’s
THERM input and stopped when THERM is un−asserted.
The timer counts THERM times cumulatively, that is, the
timer resumes counting on the next THERM assertion. The
THERM timer continues to accumulate THERM assertion
times until the timer is read (it is cleared on read) or until it
reaches full scale. If the counter reaches full scale, it stops at
that reading until cleared.
The 8−bit THERM timer status register (0x79) is designed
so that the Bit 0 is set to 1 on the first THERM assertion. Once
the cumulative THERM assertion time has exceeded 45.52
ms, Bit 1 of the THERM timer is set and Bit 0 becomes the
LSB of the timer with a resolution of 22.76 ms, see Figure 27.
When using the THERM timer, be aware of the following.
After a THERM timer read (Register 0x79), the following
happens:
1. The contents of the timer are cleared on read.
2. The F4P bit (Bit 5) of Interrupt Status Register 2
needs to be cleared (assuming that the THERM
timer limit has been exceeded).
If the THERM timer is read during a THERM assertion,
the following happens:
3. The contents of the timer are cleared.
4. Bit 0 of the THERM timer is set to 1 (because a
THERM assertion is occurring).
5. The THERM timer increments from zero.
6. If the THERM timer limit (Register 0x7A) = 0x00,
the F4P bit is set.
Bit Setting
Configuration Register 3 (0x78)
[0] ALERT Enable = 1
Assigning THERM Functionality to a Pin
Pin 9 on the ADT7475 has four possible functions:
SMBALERT, THERM, GPIO, and TACH4. The user
chooses the required functionality by setting Bit 0 and Bit 1
of Configuration Register 4 (0x7D).
Table 9. Pin 9 Configuration
Bit 1
Bit 0
Function
0
0
TACH4
0
1
THERM
1
0
SMBALERT
1
1
GPIO
Once Pin 9 is configured as THERM, it must be enabled
(Bit 1, Configuration Register 3 (0x78)).
THERM as an Input
When THERM is configured as an input, the user can time
assertions on the THERM pin. This can be useful for
connecting to the PROCHOT output of a CPU to gauge
system performance.
The user can also set up the ADT7475 so that, when the
THERM pin is driven low externally, the fans run at 100%.
The fans run at 100% for the duration of the time that the
THERM pin is pulled low. This is done by setting the
BOOST bit (Bit 2) in Configuration Register 3 (0x78) to 1.
This works only if the fan is already running, for example,
in manual mode when the current duty cycle is above 0x00
or in automatic mode when the temperature is above TMIN.
If the temperature is below TMIN or if the duty cycle in
manual mode is set to 0x00, pulling the THERM low
externally has no effect. See Figure 26 for more information.
THERM
THERM
TIMER
(REG. 0x79)
TMIN
0 0 0 0 0 0 0 1
7 6 5 4 3 2 1 0
THERM ASSERTED
3 22.76ms
THERM
THERM
ACCUMULATE THERM LOW
ASSERTION TIMES
THERM
TIMER
(REG. 0x79)
THERM ASSERTED TO LOW AS AN INPUT:
FANS DO NOT GO TO 100% BECAUSE
TEMPERATURE IS BELOW TMIN.
0 0 0 0 0 0 1 0
7 6 5 4 3 2 1 0
THERM ASSERTED
≥ 45.52ms
THERM
THERM ASSERTED TO LOW AS AN INPUT:
FANS DO NOT GO TO 100% BECAUSE
TEMPERATURE IS ABOVE TMIN AND FANS
ARE ALREADY RUNNING.
ACCUMULATE THERM LOW
ASSERTION TIMES
THERM
TIMER
(REG. 0x79)
Figure 26. Asserting THERM Low as an Input in
Automatic Fan Speed Control Mode
0 0 0 0 0 1 0 1
7 6 5 4 3 2 1 0 THERM ASSERTED ≥ 113.8ms
(91.04ms + 22.76ms)
Figure 27. Understanding the THERM Timer
http://onsemi.com
19
ADT7475
Generating SMBALERT Interrupts from A THERM
Timer Events
If the THERM timer value exceeds the THERM timer
limit value, then the F4P bit (Bit 5) of Interrupt Status
Register 2 is set, and an SMBALERT is generated. Note that
the F4P bit (Bit 5) of Interrupt Mask Register 2 (0x75) masks
out SMBALERTs if this bit is set to 1, although the F4P bit
of Interrupt Status Register 2 is still set if the THERM timer
limit is exceeded.
Figure 28 is a functional block diagram of the THERM
timer, limit, and associated circuitry. Writing a value of 0x00
to the THERM timer limit register (0x7A) causes
SMBALERT to be generated on the first THERM assertion. A
THERM timer limit value of 0x01 generates an SMBALERT
once cumulative THERM assertions exceed 45.52 ms.
The ADT7475 can generate SMBALERTs when a
programmable THERM timer limit has been exceeded. This
allows the system designer to ignore brief, infrequent
THERM assertions, while capturing longer THERM timer
events. Register 0x7A is the THERM timer limit register.
This 8−bit register allows a limit from 0 seconds (first
THERM assertion) to 5.825 seconds to be set before an
SMBALERT is generated. The THERM timer value is
compared with the contents of the THERM timer limit
register.
2.914s
1.457s
728.32ms
364.16ms THERM TIMER
182.08ms (REGISTER 0x79)
91.04ms
45.52ms
22.76ms
2.914s
1.457s
728.32ms
364.16ms
THERM
TIMER LIMIT
182.08ms
(REGISTER 0x7A) 91.04ms
45.52ms
22.76ms
0 1 2 3 4 5 6 7
7 6 5 4 3 2 1 0
THERM
THERM TIMER CLEARED ON READ
COMPARATOR
IN
OUT
LATCH
F4P BIT (BIT 5)
INTERRUPT STATUS
REGISTER 2
SMBALERT
RESET
CLEARED
ON READ
1 = MASK
F4P BIT (BIT 5)
INTERRUPT MASK REGISTER 2
(REGISTER 0x75)
Figure 28. Functional Block Diagram of the ADT7475 THERM Monitoring Circuitry
Configuring the THERM Behavior
3. Select whether THERM timer events should
generate SMBALERT interrupts.
Bit 5 (F4P) of Interrupt Mask Register 2 (0x75),
when set, masks out SMBALERTs when the
THERM timer limit value is exceeded. This bit
should be cleared if SMBALERTs based on
THERM events are required.
4. Select a suitable THERM limit value.
This value determines whether an SMBALERT is
generated on the first THERM assertion or only if
a cumulative THERM assertion time limit is
exceeded. A value of 0x00 causes an SMBALERT
to be generated on the first THERM assertion.
5. Select a THERM monitoring time.
This value specifies how often OS− or BIOS−level
software checks the THERM timer. For example,
BIOS could read the THERM timer once an hour to
determine the cumulative THERM assertion time.
If, for example, the total THERM assertion time is
<22.76 ms in Hour 1, >182.08 ms in Hour 2, and
>2.914 s in Hour 3, this can indicate that system
1. Configure the relevant pin as the THERM timer
input. Setting Bit 1 (THERM) of Configuration
Register 3 (0x78) enables the THERM timer
monitoring functionality. This is disabled on Pin 9
by default.
Setting Bit 0 and Bit 1 (PIN9FUNC) of
Configuration Register 4 (0x7D) enables THERM
timer/output functionality on Pin 9 (Bit 1,
THERM, of Configuration Register 3, must also
be set). Pin 9 can also be used as TACH4.
2. Select the desired fan behavior for THERM timer
events.
Assuming that the fans are running, setting Bit 2
(BOOST bit) of Configuration Register 3 (0x78)
causes all fans to run at 100% duty cycle whenever
THERM is asserted. This allows fail−safe system
cooling. If this bit is 0, the fans run at their current
settings and are not affected by THERM events. If
the fans are not already running when THERM is
asserted, the fans do not run to full speed.
http://onsemi.com
20
ADT7475
Enabling and Disabling THERM on Individual
Channels
performance is degrading significantly because
THERM is asserting more frequently on an hourly
basis.
Alternatively, OS− or BIOS−level software can
time−stamp when the system is powered on. If an
SMBALERT is generated due to the THERM timer
limit being exceeded, another time−stamp can be
taken. The difference in time can be calculated for a
fixed THERM timer limit time. For example, if it
takes one week for a THERM timer limit of 2.914
seconds to be exceeded and the next time it takes
only one hour, this is an indication of a serious
degradation in system performance.
THERM can be enabled/disabled for individual or
combinations of temperature channels using Bits [7:5] of
Configuration Register 5 (0x7C).
THERM Hysteresis
Setting Bit 0 of Configuration Register 7 (0x11) disables
THERM hysteresis.
If THERM hysteresis is enabled and THERM is disabled
(Bit 2 of Configuration Register 4, 0x7D), the THERM pin
does not assert low when a THERM event occurs. If
THERM hysteresis is disabled and THERM is disabled
(Bit 2 of Configuration Register 4, 0x7D, and assuming the
appropriate pin is configured as THERM), the THERM pin
asserts low when a THERM event occurs.
If THERM and THERM hysteresis are both enabled, the
THERM output asserts as expected.
Configuring the THERM Pin as an Output
In addition to monitoring THERM as an input, the
ADT7475 can optionally drive THERM low as an output. In
cases where PROCHOT is bidirectional, THERM can be
used to throttle the processor by asserting PROCHOT. The
user can pre−program system−critical thermal limits. If the
temperature exceeds a thermal limit by 0.25°C, THERM
asserts low. If the temperature is still above the thermal limit
on the next monitoring cycle, THERM stays low. THERM
remains asserted low until the temperature is equal to or
below the thermal limit. Because the temperature for that
channel is measured only once for every monitoring cycle,
after THERM asserts, it is guaranteed to remain low for at
least one monitoring cycle.
The THERM pin can be configured to assert low if the
Remote 1, local, or Remote 2 THERM temperature limit is
exceeded by 0.25°C. The THERM temperature limit
registers are at Register 0x6A, Register 0x6B, and Register
0x6C. Setting Bit 3 of Register 0x5F, Register 0x60, and
Register 0x61 enables the THERM output feature for the
Remote 1, local, and Remote 2 temperature channels,
respectively. Figure 29 shows how the THERM pin asserts
low as an output in the event of a critical over temperature.
THERM Operation in Manual Mode
In manual mode, THERM events do not cause fans to go
to full speed, unless Bit 3 of Configuration Register 6 (0x10)
is set to 1.
Additionally, Bit 3 of Configuration Register 4 (0x7D)
can be used to select PWM speed on THERM event (100%
or maximum PWM).
Bit 2 in Configuration Register 4 (0x7D) can be set to
disable THERM events from affecting the fans.
Fan Drive Using PWM Control
The ADT7475 uses pulse−width modulation (PWM) to
control fan speed. This relies on varying the duty cycle (or
on/off ratio) of a square wave applied to the fan to vary the
fan speed. The external circuitry required to drive a fan using
PWM control is extremely simple. For 4−wire fans, the
PWM drive may need only a pullup resistor. In many cases,
the 4−wire fan PWM input has a built−in pullup resistor.
The ADT7475 PWM frequency can be set to a selection
of low frequencies or a single high PWM frequency. The
low frequency options are usually used for 3−wire fans,
while the high frequency option is usually used with 4−wire
fans.
For 3−wire fans, a single N−channel MOSFET is the only
drive device required. The specifications of the MOSFET
depend on the maximum current required by the fan being
driven. Typical notebook fans draw a nominal 170 mA, so
SOT devices can be used where board space is a concern. In
desktops, fans can typically draw 250 mA to 300 mA each.
If several fans are driven in parallel from a single PWM
output or drive larger server fans, the MOSFET must handle
the higher current requirements.
The only other stipulation is that the MOSFET should
have a gate voltage drive, VGS < 3.3 V, for direct interfacing
to the PWM output pin. The MOSFET should also have a
low on resistance to ensure that there is not significant
voltage drop across the FET, which would reduce the
THERM LIMIT
0.255C
THERM LIMIT
TEMP
THERM
MONITORING
CYCLE
Figure 29. Asserting THERM as an Output, Based on
Tripping THERM Limits
An alternative method of disabling THERM is to program
the THERM temperature limit to 64°C or less in Offset 64
mode, or 128°C or less in twos complement mode; that is, for
THERM temperature limit values less than 64°C or 128°C,
respectively, THERM is disabled.
http://onsemi.com
21
ADT7475
voltage applied across the fan and, therefore, the maximum
operating speed of the fan.
Figure 30 shows how to drive a 3−wire fan using PWM
control.
12V
12V
12V, 4−WIRE FAN
10kΩ
ADT7475
12V
FAN
4.7kΩ
ADT7475
TACH
4.7kΩ
TACH
PWM
3.3V
10kΩ
TACH
VCC
10kΩ
TACH
12V
10kΩ
12V
2kΩ
1N4148
PWM
3.3V
Figure 32. Driving a 4−Wire Fan
10kΩ
Driving Two Fans from PWM3
Q1
NDT3055L
The ADT7475 has four TACH inputs available for fan
speed measurement but only three PWM drive outputs. If a
fourth fan is used in the system, it should be driven from the
PWM3 output in parallel with the third fan. Figure 33 shows
how to drive two fans in parallel using low cost NPN
transistors. Figure 34 shows the equivalent circuit using a
MOSFET.
Figure 30. Driving a 3−Wire Fan Using an N−Channel
MOSFET
Figure 30 uses a 10 kW pullup resistor for the TACH
signal. This assumes that the TACH signal is an
open−collector from the fan. In all cases, the TACH signal
from the fan must be kept below 3.6 V maximum to prevent
damaging the ADT7475. If in doubt as to whether the fan
used has an open−collector or totem pole TACH output, use
one of the input signal conditioning circuits shown in the Fan
Speed Measurement section.
Figure 31 shows a fan drive circuit using an NPN
transistor such as a general−purpose MMBT2222. While
these devices are inexpensive, they tend to have much lower
current handling capabilities and higher on resistance than
MOSFETs. When choosing a transistor, care should be taken
to ensure that it meets the fan’s current requirements.
Ensure that the base resistor is chosen so that the transistor
is saturated when the fan is powered on.
12V
12V
3.3V
ADT7475
PWM3
10kΩ
4.7kΩ
ADT7475
TACH
TACH4
Q1
MMBT3904
2.2k
Q2
MMBT2222
10
Q3
MMBT2222
Figure 33. Interfacing Two Fans in Parallel to the
PWM3 Output Using Low Cost NPN Transistors
3.3V
12V
10kΩ
TYPICAL
TACH4
12V
FAN
1N4148
+V
3.3V
ADT7475
3.3V
Q1
MMBT2222
+V
10kΩ
TYPICAL
TACH3
665Ω
PWM
TACH3
1k
10
10kΩ
TACH
3.3V
1N4148
PWM
TACH
5V OR
12V FAN
3.3V
PWM3
Because 4−wire fans are powered continuously, the fan
speed is not switched on or off as with previous PWM
driven/powered fans. This enables it to perform better than
3−wire fans, especially for high frequency applications.
Figure 32 shows a typical drive circuit for 4−wire fans.
TACH
5V OR
12V FAN
10kΩ
TYPICAL
Figure 31. Driving a 3−Wire Fan Using an NPN
Transistor
1N4148
Q1
NDT3055L
Figure 34. Interfacing Two Fans in Parallel to the
PWM3 Output Using a Single N−Channel MOSFET
Because the MOSFET can handle up to 3.5 A, it is simply
a matter of connecting another fan directly in parallel with
the first. Care should be taken in designing drive circuits
with transistors and FETs to ensure that the PWM pins are
not required to source current and that they sink less than the
8 mA maximum current specified on the data sheet.
http://onsemi.com
22
ADT7475
Driving up to Three Fans from PWM3
If the fan has a strong pullup (less than 1 kW) to 12 V or
a totem−pole output, then a series resistor can be added to
limit the Zener current, as shown in Figure 37.
TACH measurements for fans are synchronized to
particular PWM channels; for example, TACH1 is
synchronized to PWM1. TACH3 and TACH4 are both
synchronized to PWM3, so PWM3 can drive two fans.
Alternatively, PWM3 can be programmed to synchronize
TACH2, TACH3, and TACH4 to the PWM3 output. This
allows PWM3 to drive two or three fans. In this case, the drive
circuitry looks the same, as shown in Figure 36 and Figure 37.
The SYNC bit in Register 0x62 enables this function.
Synchronization is not required in high frequency mode
when used with 4−wire fans.
VCC
5V OR 12V
FAN
PULLUP TYP
<1kΩ OR
TOTEM POLE
R1
10kΩ
TACH
OUTPUT
1CHOOSE
SYNC = 1, synchronizes TACH2, TACH3, and TACH4
to PWM3.
2.0 V t V PULLUP
Pin 4, Pin 6, Pin 7, and Pin 9, when configured as TACH
inputs, are open−drain TACH inputs intended for fan speed
measurement.
Signal conditioning in the ADT7475 accommodates the
slow rise and fall times typical of fan tachometer outputs. The
maximum input signal range is 0 V to 3.6 V. In the event these
inputs are supplied from fan outputs that exceed 0 V to 3.6 V,
either resistive attenuation of the fan signal or diode clamping
must be included to keep inputs within an acceptable range.
Figure 35 to Figure 38 show circuits for most common fan
TACH outputs. If the fan TACH output has a resistive pullup
to VCC, it can be connected directly to the fan input, as shown
in Figure 35.
(eq. 3)
The fan inputs can have an input resistance of 160 kW to
5.1 kW to ground, which should be taken into account when
calculating resistor values.
With a pullup voltage of 12 V and pullup resistor less than
1 kW, suitable values for R1 and R2 would be 100 kW and
33 kW, respectively. This gives a high input voltage of
2.95 V.
VCC
12V
<1kΩ
VCC
R11
TACH
OUTPUT
ZD11
1 CHOOSE
ADT7475
TEXT.
The fan counter does not count the fan TACH output
pulses directly because the fan speed could be less than 1000
RPM and it would take several seconds to accumulate a
reasonably large and accurate count. Instead, the period of
the fan revolution is measured by gating an on−chip 90 kHz
oscillator into the input of a 16−bit counter for N periods of
the fan TACH output (see Figure 39), so the accumulated
count is actually proportional to the fan tachometer period
and inversely proportional to the fan speed.
N, the number of pulses counted, is determined by the
settings of Register 0x7B (TACH Pulses per Revolution
register). This register contains two bits for each fan,
allowing one, two (default), three, or four TACH pulses to
be counted.
VCC
TACH
FAN SPEED
COUNTER
Fan Speed Measurement
If the fan output has a resistive pullup to 12 V, or other
voltage greater than 3.6 V, the fan output can be clamped with
a Zener diode, as shown in Figure 36. The Zener diode voltage
should be chosen so that it is greater than VIH of the TACH
input but less than 3.6 V, allowing for the voltage tolerance of
the Zener. A value between 3.0 V and 3.6 V is suitable.
TACH
OUTPUT
R21
Figure 38. Fan with Strong TACH pullup to > VCC or
Totem−Pole Output, Attenuated with R1/R2
Figure 35. Fan with TACH Pullup to VCC
PULLUP
4.7kΩ
TYPICAL
TACH
1 SEE
FAN SPEED
COUNTER
ADT7475
12V
ADT7475
ZD1 VOLTAGE APPROXIMATELY 0.8 y VCC.
R2ńǒR PULLUP ) R1 ) R2Ǔ t 3.6 V
12V
TACH
FAN SPEED
COUNTER
Alternatively, a resistive attenuator can be used, as shown
in Figure 38. R1 and R2 should be chosen such that:
TACH Inputs
TACH
OUTPUT
ZD1
ZENER1
Figure 37. Fan with Strong TACH Pullup to > VCC or
Totem−Pole Output, Clamped with Zener and Resistor
Bit 4 (SYNC) Enhanced Acoustics Register 1 (0x62)
PULLUP
4.7kΩ
TYPICAL
TACH
FAN SPEED
COUNTER
ADT7475
ZD1 VOLTAGE APPROXIMATELY 0.8 y VCC.
Measuring Fan TACH
Figure 36. Fan with TACH Pullup to Voltage > 3.6 V
(example, 12 V) Clamped with Zener Diode
When the ADT7475 starts up, TACH measurements are
locked. In effect, an internal read of the low byte has been
http://onsemi.com
23
ADT7475
Fan TACH Limit Registers
made for each TACH input. The net result of this is that all
TACH readings are locked until the high byte is read from the
corresponding TACH registers. All TACH related interrupts
are also ignored until the appropriate high byte is read.
Once the corresponding high byte has been read, TACH
measurements are unlocked and interrupts are processed as
normal.
The fan TACH limit registers are 16−bit values consisting
of two bytes.
Register 0x54, TACH1 Minimum Low Byte = 0xFF default
Register 0x55, TACH1 Minimum High Byte = 0xFF default
Register 0x56, TACH2 Minimum Low Byte = 0xFF default
Register 0x57, TACH2 Minimum High Byte = 0xFF default
Register 0x58, TACH3 Minimum Low Byte = 0xFF default
Register 0x59, TACH3 Minimum High Byte = 0xFF default
Register 0x5A, TACH4 Minimum Low Byte = 0xFF default
Register 0x5B, TACH4 Minimum High Byte = 0xFF default
CLOCK
PWM
TACH
Fan Speed Measurement Rate
1
The fan TACH readings are normally updated once every
second. The FAST bit (Bit 3) of Configuration Register 3
(0x78), when set, updates the fan TACH readings
every 250 ms.
If any of the fans are not being driven by a PWM channel
but are powered directly from 5.0 V or 12 V, their associated
dc bit in Configuration Register 3 should be set. This allows
TACH readings to be taken on a continuous basis for fans
connected directly to a dc source. For optimal results, the
associated dc bit should always be set when using 4−wire
fans.
2
3
4
Figure 39. Fan Speed Measurement
Fan Speed Measurement Registers
The fan tachometer readings are 16−bit values consisting
of a 2−byte read from the ADT7475.
Register 0x28, TACH1 Low Byte = 0x00 default
Register 0x29, TACH1 High Byte = 0x00 default
Register 0x2A, TACH2 Low Byte = 0x00 default
Register 0x2B, TACH2 High Byte = 0x00 default
Register 0x2C, TACH3 Low Byte = 0x00 default
Register 0x2D, TACH3 High Byte = 0x00 default
Register 0x2E, TACH4 Low Byte = 0x00 default
Register 0x2F, TACH4 High Byte = 0x00 default
Calculating Fan Speed
Assuming a fan with a two pulses per revolution (and two
pulses per revolution being measured), fan speed is
calculated by the following:
Fan Speed (RPM) = (90,000 x 60)/Fan TACH Reading
where Fan TACH Reading is the 16−bit fan tachometer
reading.
Reading Fan Speed from the ADT7475
Example
The measurement of fan speeds involves a 2−register read
for each measurement. The low byte should be read first.
This causes the high byte to be frozen until both high and low
byte registers have been read, preventing erroneous TACH
readings. The fan tachometer reading registers report back
the number of 11.11 ms period clocks (90 kHz oscillator)
gated to the fan speed counter, from the rising edge of the
first fan TACH pulse to the rising edge of the third fan TACH
pulse (assuming two pulses per revolution are being
counted). Because the device is essentially measuring the
fan TACH period, the higher the count value, the slower the
fan is actually running. A 16−bit fan tachometer reading of
0xFFFF indicates that the fan either has stalled or is running
very slowly (<100 RPM).
High Limit > Comparison Performed
Because the actual fan TACH period is being measured,
falling below a fan TACH limit by 1 sets the appropriate
status bit and can be used to generate an SMBALERT.
TACH1 High Byte (Register 0x29) = 0x17
TACH1 Low Byte (Register 0x28) = 0xFF
What is Fan 1 speed in RPM?
Fan 1 TACH Reading = 0x17FF = 6143 (decimal)
RPM = (f x 60)/Fan 1 TACH Reading
RPM = (90,000 x 60)/6143
Fan Speed = 879 RPM
Fan Pulses per Revolution
Different fan models can output either 1, 2, 3, or 4 TACH
pulses per revolution. Once the number of fan TACH pulses
has been determined, it can be programmed into the TACH
Pulses per Revolution register (Register 0x7B) for each fan.
Alternatively, this register can be used to determine the
number or pulses per revolution output by a given fan. By
plotting fan speed measurements at 100% speed with
different pulses per revolution setting, the smoothest graph
with the lowest ripple determines the correct pulses per
revolution value.
http://onsemi.com
24
ADT7475
TACH Pulses per Revolution Register
PWM1 Configuration Register (0x5C)
Bits [1:0] Fan 1 default = 2 pulses per revolution.
Bits [3:2] Fan 2 default = 2 pulses per revolution.
Bits [5:4] Fan 3 default = 2 pulses per revolution.
Bits [7:6] Fan 4 default = 2 pulses per revolution.
00 = 1 pulse per revolution
01 = 2 pulses per revolution
10 = 3 pulses per revolution
11 = 4 pulses per revolution
Bit 4 INV
0 = Logic high for 100% PWM duty cycle.
1 = Logic low for 100% PWM duty cycle.
Fan Spin−Up
Bit 4 INV
0 = Logic high for 100% PWM duty cycle.
1 = Logic low for 100% PWM duty cycle.
PWM2 Configuration Register (0x5D)
Bit 4 INV
0 = Logic high for 100% PWM duty cycle.
1 = Logic low for 100% PWM duty cycle.
PWM3 Configuration Register (0x5E)
The ADT7475 has a unique fan spin−up function. It spins
the fan at 100% PWM duty cycle until two TACH pulses are
detected on the TACH input. Once two TACH pulses have
been detected, the PWM duty cycle goes to the expected
running value, for example, 33%. The advantage is that fans
have different spin−up characteristics and take different
times to overcome inertia. The ADT7475 runs the fans just
fast enough to overcome inertia and is quieter on spin−up
than fans programmed to spin up for a given spin−up time.
Low Frequency Mode PWM Drive Frequency
The PWM drive frequency can be adjusted for the
application. Register 0x5F to Register 0x61 configure the
PWM frequency for PWM1 to PWM3, respectively. In high
frequency mode, the PWM drive frequency is always
22.5 kHz.
Fan Startup Timeout
High Frequency Mode PWM Drive
To prevent the generation of false interrupts as a fan spins
up (because it is below running speed), the ADT7475
includes a fan startup timeout function. During this time, the
ADT7475 looks for two TACH pulses. If two TACH pulses
are not detected, an interrupt is generated. Using
Configuration Register 1 (0x40), Bit 5 (FSPDIS), this
functionality can be changed (see the Disabling Fan Startup
Timeout section).
Setting Bit 3 of Register 0x5F, Register 0x60, and
Register 0x61 enables high frequency mode for Fan 1,
Fan 2, and Fan 3, respectively.
PWM Frequency Registers (0x5F to 0x61)
Bits [2:0] FREQ
000 = 11.0 Hz
001 = 14.7 Hz
010 = 22.1 Hz
011 = 29.4 Hz
100 = 35.3 Hz default
101 = 44.1 Hz
110 = 58.8 Hz
111 = 88.2 Hz
PWM1, PWM2, PWM3 Configuration Registers
(0x5C, 0x5D, and 0x5E)
Bits [2:0] SPIN, startup timeout for PWM1 = 0x5C,
PWM2 = 0x5D, and PWM3 = 0x5E.
000 = No startup timeout
001 = 100 ms
010 = 250 ms default
011 = 400 ms
100 = 667 ms
101 = 1 sec
110 = 2 sec
111 = 4 sec
Fan Speed Control
The ADT7475 controls fan speed using automatic mode
and manual mode as follows:
• In automatic fan speed control mode, fan speed is
automatically varied with temperature and without CPU
intervention, once initial parameters are set up. The
advantage of this is, if the system hangs, the user is
guaranteed that the system is protected from overheating.
For more information about how to program
the automatic fan speed control loop, see the
Programming the Automatic Fan Speed Control Loop
section.
• In manual fan speed control mode, the ADT7475 allows
the duty cycle of any PWM output to be manually
adjusted. This can be useful if the user wants to change
fan speed at the software level or adjust PWM duty
cycle output for test purposes. Bits [7:5] of Register
0x5C to Register 0x5E (PWM configuration) control the
behavior of each PWM output.
Disabling Fan Startup Timeout
Although fan startup makes fan spin−ups much quieter
than fixed−time spin−ups, the option exists to use fixed
spin−up times. Setting Bit 5 (FSPDIS) to 1 in Configuration
Register 1 (0x40) disables the spin−up for two TACH
pulses. Instead, the fan spins up for the fixed time as selected
in Register 0x5C to Register 0x5E.
PWM Logic State
The PWM outputs can be programmed high for 100%
duty cycle (non−inverted) or low for 100% duty cycle
(inverted).
http://onsemi.com
25
ADT7475
PWM Configuration Registers (0x5C to 0x5E)
XNOR Tree Test Mode
Bits [7:5] BHVR
111 = manual mode.
Once under manual control, each PWM output can be
manually updated by writing to Register 0x30 to Register
0x32 (PWMx current duty cycle registers).
The ADT7475 includes an XNOR tree test mode. This
mode is useful for in−circuit test equipment at board−level
testing. By applying stimulus to the pins included in the
XNOR tree, it is possible to detect opens or shorts on the
system board.
Figure 40 shows the signals that are exercised in the XNOR
tree test mode. The XNOR tree test is invoked by setting Bit 0
(XEN) of the XNOR tree test enable register (0x6F).
Programming the PWM Current Duty Cycle Registers
The PWM current duty cycle registers are 8−bit registers
that allow the PWM duty cycle for each output to be set
anywhere from 0% to 100% in steps of 0.39%.
The value to be programmed into the PWMMIN register is
given by:
Value (decimal) = PWMMIN /0.39
Example 1: For a PWM duty cycle of 50%,
Value (decimal) = 50/0.39 = 128 (decimal)
Value = 128 (decimal) or 0x80 (hex)
Example 2: For a PWM duty cycle of 33%,
Value (decimal) = 33/0.39 = 85 (decimal)
Value = 85 (decimal) or 0x54 (hex)
TACH1
TACH2
TACH3
TACH4
PWM2
PWM1/XTO
PWM3
Figure 40. XNOR Tree Test
PWM Current Duty Cycle Registers
Register 0x30, PWM1 Current Duty Cycle = 0x00
(0% default)
Register 0x31, PWM2 Current Duty Cycle = 0x00
(0% default)
Register 0x32, PWM3 Current Duty Cycle = 0x00
(0% default)
By reading the PWMx current duty cycle registers, the
user can keep track of the current duty cycle on each PWM
output, even when the fans are running in automatic fan
speed control mode or acoustic enhancement mode. See the
Programming the Automatic Fan Speed Control Loop
section for details.
ADT7475 IS POWERED UP
HAS THE ADT7475 BEEN
ACCESSED BY A VALID
SMBus TRANSACTION?
Y
N
IS VCCP ABOVE 0.75V?
N
CHECK VCCP
Y
START FAIL−SAFE TIMER
HAS THE ADT7475 BEEN
ACCESSED BY A VALID
SMBus TRANSACTION?
Y
Operating from 3.3 V Standby
N
The ADT7475 has been specifically designed to operate
from a 3.3 V STBY supply. In computers that support S3 and
S5 states, the core voltage of the processor is lowered in
these states. When monitoring THERM, the THERM timer
should be disabled during these states.
FAIL−SAFE TIMER ELAPSES
AFTER THE FAIL−SAFE TIMEOUT
HAS THE ADT7475 BEEN
ACCESSED BY A VALID
SMBus TRANSACTION?
N
RUNS THE FANS
TO FULL SPEED
Y
Standby Mode
The ADT7475 has been specifically designed to respond to
the STBY supply. In computers that support S3 and S5 states,
the core voltage of the processor is lowered in these states.
When monitoring THERM, the THERM timer should be
disabled during these states.
When the VCCP voltage drops below the VCCP low limit,
the following occurs:
1. Status Bit 1 (VCCP) in Status Register 1 is set.
2. SMBALERT is generated, if enabled.
3. THERM monitoring is disabled. The THERM timer
should hold its value prior to the S3 or S5 state.
Once the core voltage, VCCP, goes above the VCCP low
limit, everything is re−enabled and the system resumes
normal operation.
HAS THE ADT7475 BEEN
ACCESSED BY A VALID
SMBus TRANSACTION?
N
Y
STARTUP THE
ADT7475 NORMALLY
SWITCH OFF FANS
Figure 41. Power−On Flow Chart
Power−On Default
When the ADT7475 is powered up, it polls the VCCP
input.
If VCCP stays below 0.75 V (the system CPU power rail
is not powered up), the ADT7475 assumes the functionality
of the default registers after the ADT7475 is addressed via
any valid SMBus transaction.
http://onsemi.com
26
ADT7475
If VCC goes high (the system processor power rail is
powered up), a fail−safe timer begins to count down. If the
ADT7475 is not addressed by any valid SMBus transactions
before the fail−safe timeout (4.6 seconds) lapses, the
ADT7475 drives the fans to full speed. If the ADT7475 is
addressed by a valid SMBus transaction after this point, the
fans stop, and the ADT7475 assumes its default settings and
begins normal operation.
If VCCP goes high (the system processor power rail is
powered up), then a fail−safe timer begins to count down. If
the ADT7475 is addressed by a valid SMBus transaction
before the fail−safe timeout (4.6 seconds) lapses, then the
ADT7475 operates normally, assuming the functionality of
all the default registers. See the flow chart in Figure 41.
mote temperature channels that can be connected to a CPU
on−chip thermal diode (available on Intel Pentium class and
other CPUs). These three temperature channels can be used
as the basis for automatic fan speed control to drive fans
using pulse−width modulation (PWM).
Automatic fan speed control reduces acoustic noise by
optimizing fan speed according to accurately measured
temperature. Reducing fan speed can also decrease system
current consumption.
The automatic fan speed control mode is very flexible owing
to the number of programmable parameters, including TMIN
and TRANGE. The TMIN and TRANGE values for a temperature
channel, and, therefore, for a given fan are critical because they
define the thermal characteristics of the system. The thermal
validation of the system is one of the most important steps in
the design process, so select these values carefully.
Figure 42 gives a top−level overview of the automatic fan
control circuitry on the ADT7475. From a systems level
perspective, up to three system temperatures can be
monitored and used to control three PWM outputs. The three
PWM outputs can be used to control up to four fans. The
ADT7475 allows the speed of four fans to be monitored.
Each temperature channel has a thermal calibration block,
allowing the designer to individually configure the thermal
characteristics of each temperature channel.
For example, the designer can decide to run the CPU fan
when CPU temperature increases above 60°C and a chassis
fan when the local temperature increases above 45°C. At this
stage, the designer has not assigned these thermal calibration
settings to a particular fan drive (PWM) channel. The right
side of Figure 42 shows controls that are fan−specific. The
designer has individual control over parameters such as
minimum PWM duty cycle, fan speed failure thresholds,
and even ramp control of the PWM outputs. Automatic fan
control, then, ultimately allows graceful fan speed changes
that are less perceptible to the system user.
Programming the Automatic Fan Speed Control Loop
To more efficiently understand the automatic fan speed
control loop, it is strongly recommended to use the ADT7475
evaluation board and software while reading this section.
This section provides the system designer with an
understanding of the automatic fan control loop, and
provides step−by−step guidance on effectively evaluating
and selecting critical system parameters. To optimize the
system characteristics, the designer needs to give some
thought to system configuration, including the number of
fans, where they are located, and what temperatures are
being measured in the particular system.
The mechanical or thermal engineer who is tasked with
the system thermal characterization should also be involved
at the beginning of this process.
Automatic Fan Control Overview
The ADT7475 can automatically control the speed of fans
based upon the measured temperature. This is done
independently of CPU intervention once initial parameters
are set up.
The ADT7475 has a local temperature sensor and two re−
THERMAL CALIBRATION
PWM
MIN
100%
PWM
CONFIG
PWM
GENERATOR
REMOTE 1
TEMP
TMIN
TRANGE
THERMAL CALIBRATION
0%
PWM
MIN
100%
TACHOMETER 1
MEASUREMENT
PWM
CONFIG
PWM
GENERATOR
MUX
LOCAL
TEMP
TMIN
TRANGE
THERMAL CALIBRATION
100%
PWM
CONFIG
PWM
GENERATOR
REMOTE 2
TEMP
TMIN
TRANGE
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
Figure 42. Automatic Fan Control Block Diagram
http://onsemi.com
27
PWM2
TACH2
TACHOMETER 3
AND 4
MEASUREMENT
0%
PWM1
TACH1
TACHOMETER 2
MEASUREMENT
0%
PWM
MIN
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
PWM3
TACH3
ADT7475
Step 1: Hardware Configuration
whether to use the TACH4 pin or to reconfigure it
for the THERM function.
3. s the CPU fan to be controlled using the ADT7475
or will it run at full speed 100% of the time?
If run at 100%, this frees up a PWM output, but
the system is louder.
4. Where will the ADT7475 be physically located in
the system?
This influences the assignment of the temperature
measurement channels to particular system
thermal zones. For example, locating the
ADT7475 close to the VRM controller circuitry
allows the VRM temperature to be monitored
using the local temperature channel.
During system design, the motherboard sensing and
control capabilities should be addressed early in the design
stages. Decisions about how these capabilities are used
should involve the system thermal/mechanical engineer.
Ask the following questions:
1. What ADT7475 functionality will be used?
• PWM2 or SMBALERT?
• TACH4 fan speed measurement or
overtemperature THERM function?
The ADT7475 offers multifunctional pins that
can be reconfigured to suit different system
requirements and physical layouts. These
multifunction pins are software programmable.
2. How many fans will be supported in the system,
three or four? This influences the choice of
THERMAL CALIBRATION
PWM
MIN
100%
PWM
CONFIG
PWM
GENERATOR
TMIN
REMOTE 1 =
AMBIENT TEMP
TRANGE
THERMAL CALIBRATION
0%
PWM
MIN
100%
TMIN
LOCAL =
VRM TEMP
TRANGE
THERMAL CALIBRATION
TACHOMETER 1
MEASUREMENT
PWM
CONFIG
PWM
GENERATOR
MUX
0%
PWM
MIN
100%
PWM
CONFIG
TRANGE
CPU FAN SINK
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
PWM2
TACH2
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
TACHOMETER 3
AND 4
MEASUREMENT
0%
PWM1
TACH1
TACHOMETER 2
MEASUREMENT
PWM
GENERATOR
TMIN
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
REMOTE 2 =
CPU TEMP
FRONT CHASSIS
PWM3
TACH3
REAR CHASSIS
Figure 43. Hardware Configuration Example
http://onsemi.com
28
ADT7475
• CPU temperature measured using the Remote 1
Recommended Implementation 1
Configuring the ADT7475 as in Figure 44 provides the
system designer with the following features:
• Two PWM outputs for fan control of up to three fans.
(The front and rear chassis fans are connected in
parallel.)
• Three TACH fan speed measurement inputs.
• VCC measured internally through Pin 3.
• CPU core voltage measurement (VCORE).
• VRM temperature using local temperature sensor.
•
•
•
temperature channel.
Ambient temperature measured through the Remote 2
temperature channel.
Bidirectional THERM pin, which allows the monitoring
of PROCHOT output from an Intel Pentium 4 processor,
for example, or can be used as an overtemperature
THERM output.
SMBALERT system interrupt output.
ADT7475
FRONT
CHASSIS
FAN
TACH2
PWM1
TACH1
CPU FAN
PWM3
REAR
CHASSIS
FAN
D2+
TACH3
D2–
THERM
AMBIENT
TEMPERATURE
D1+
PROCHOT
CPU
SDA
SCL
D1–
SMBALERT
GND
ICH
Figure 44. Recommended Implementation 1
http://onsemi.com
29
ADT7475
• CPU temperature measured using the Remote 1
Recommended Implementation 2
Configuring the ADT7475 as in Figure 45 provides the
system designer with the following features:
• Three PWM outputs for fan control of up to three fans.
(All three fans can be individually controlled.)
• Three TACH fan speed measurement inputs.
• VCC measured internally through Pin 3.
• CPU core voltage measurement (VCORE).
•
•
temperature channel.
Ambient temperature measured through the Remote 2
temperature channel.
Bidirectional THERM pin that allows the monitoring of
PROCHOT output from an Intel Pentium 4 processor,
for example, or can be used as an overtemperature
THERM output.
ADT7475
FRONT
CHASSIS
FAN
TACH2
PWM1
PWM2
TACH1
CPU FAN
PWM3
REAR
CHASSIS
FAN
D2+
TACH3
D2–
THERM
AMBIENT
TEMPERATURE
PROCHOT
CPU
SDA
D1+
SCL
D1–
GND
Figure 45. Recommended Implementation 2
http://onsemi.com
30
ICH
ADT7475
Step 2: Configuring the Mux
010 = Remote 2 temperature controls PWMx
101 = Fastest speed calculated by local and Remote 2
temperature controls PWMx
110 = Fastest speed calculated by all three
temperature channel controls PWMx
The fastest speed calculated options pertain to controlling
one PWM output based on multiple temperature channels.
The thermal characteristics of the three temperature zones
can be set to drive a single fan. An example is the fan turning
on when Remote 1 temperature exceeds 60°C or when the
local temperature exceeds 45°C.
After the system hardware configuration is determined,
the fans can be assigned to particular temperature channels.
Not only can fans be assigned to individual channels but the
behavior of the fans is also configurable. For example, fans
can be run under automatic fan control, manually under
software control, or at the fastest speed calculated by
multiple temperature channels. The mux is the bridge
between temperature measurement channels and the three
PWM outputs.
Bits [7:5] (BHVR) of Register 0x5C, Register 0x5D, and
Register 0x5E (PWM configuration registers) control the
behavior of the fans connected to the PWM1, PWM2, and
PWM3 outputs. The values selected for these bits determine
how the mux connects a temperature measurement channel
to a PWM output.
Other Mux Options
Bits [7:5] (BHVR), Register 0x5C, Register 0x5D, and
Register 0x5E.
011 = PWMx runs full speed.
100 = PWMx disabled (default).
111 = manual mode. PWMx is running under
software control. In this mode, PWM current
duty cycle registers (0x30 to 0x32) are writable
and control the PWM outputs.
Automatic Fan Control Mux Options
Bits [7:5] (BHVR), Register 0x5C, Register 0x5D, and
Register 0x5E.
000 = Remote 1 temperature controls PWMx
001 = local temperature controls PWMx
MUX
THERMAL CALIBRATION
PWM
MIN
100%
PWM
CONFIG
PWM
GENERATOR
TMIN
REMOTE 1 =
AMBIENT TEMP
TRANGE
THERMAL CALIBRATION
0%
PWM
MIN
100%
TMIN
LOCAL =
VRM TEMP
TRANGE
THERMAL CALIBRATION
TACHOMETER 1
MEASUREMENT
PWM
CONFIG
PWM
GENERATOR
MUX
0%
PWM
MIN
100%
PWM
CONFIG
TRANGE
CPU FAN SINK
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
PWM2
TACH2
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
TACHOMETER 3
AND 4
MEASUREMENT
0%
PWM1
TACH1
TACHOMETER 2
MEASUREMENT
PWM
GENERATOR
TMIN
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
REMOTE 2 =
CPU TEMP
FRONT CHASSIS
PWM3
TACH3
REAR CHASSIS
Figure 46. Assigning Temperature Channels to Fan Channels
http://onsemi.com
31
ADT7475
• PWM3 (rear chassis fan) is controlled by the Remote 1
Mux Configuration Example
This is an example of how to configure the mux in a
system using the ADT7475 to control three fans. The CPU
fan sink is controlled by PWM1, the front chassis fan is
controlled by PWM2, and the rear chassis fan is controlled
by PWM3. The mux is configured for the following fan
control behavior:
• PWM1 (CPU fan sink) is controlled by the fastest speed
calculated by the local (VRM temperature) and
Remote 2 (processor) Temperatures. In this case, the
CPU fan sink is also used to cool the VRM.
• PWM2 (front chassis fan) is controlled by the Remote 1
Temperature (ambient).
THERMAL CALIBRATION
Temperature (ambient).
Example Mux Settings
Bits [7:5] (BHVR), PWM1 Configuration Register (0x5C).
101 = Fastest speed calculated by local and Remote 2
temperature controls PWM1
Bits [7:5] (BHVR), PWM2 Configuration Register (0x5D).
000 = Remote 1 temperature controls PWM2
Bits [7:5] (BHVR), PWM3 Configuration Register (0x5E).
000 = Remote 1 temperature controls PWM3
These settings configure the mux, as shown in Figure 47.
PWM
MIN
100%
PWM
CONFIG
PWM
GENERATOR
TMIN
REMOTE 2 =
CPU TEMP
TRANGE
THERMAL CALIBRATION
0%
MUX
100%
PWM
MIN
TACHOMETER 1
MEASUREMENT
PWM
CONFIG
PWM
GENERATOR
TMIN
LOCAL =
VRM TEMP
TRANGE
THERMAL CALIBRATION
0%
PWM
MIN
100%
PWM
CONFIG
TRANGE
TACHOMETER 3
AND 4
MEASUREMENT
0%
PWM1
TACH1
CPU FAN SINK
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
TACHOMETER 2
MEASUREMENT
PWM
GENERATOR
TMIN
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
PWM2
TACH2
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
FRONT CHASSIS
PWM3
TACH3
REMOTE 1 =
AMBIENT TEMP
REAR CHASSIS
Figure 47. Mux Configuration Example
Step 3: TMIN Settings for Thermal Calibration Channels
To overcome fan inertia, the fan is spun up until two valid
TACH rising edges are counted. See the Fan Startup
Timeout Section for more details. In some cases, primarily
for psycho−acoustic reasons, it is desirable that the fan never
switch off below TMIN. Bits [7:5] of Enhanced Acoustics
Register 1 (0x62), when set, keep the fans running at the
PWM minimum duty cycle, if the temperature should fall
below TMIN.
TMIN is the temperature at which the fans turn on under
automatic fan control. The speed at which the fan runs at
TMIN is programmed later in the process. The TMIN values
chosen are temperature channel specific, for example, 25°C
for ambient channel, 30°C for VRM temperature, and 40°C
for processor temperature.
TMIN is an 8−bit value, either twos complement or
Offset 64, that can be programmed in 1°C increments. There
is a TMIN register associated with each temperature
measurement channel: Remote 1, local, and Remote 2
temperatures. Once the TMIN value is exceeded, the fan turns
on and runs at the minimum PWM duty cycle. The fan turns
off once the temperature has dropped below TMIN − THYST.
TMIN Registers
Register 0x67, Remote 1 Temperature TMIN = 0x5A (90°C)
Register 0x68, Local Temperature TMIN = 0x5A (90°C)
Register 0x69, Remote 2 Temperature TMIN = 0x5A (90°C)
http://onsemi.com
32
ADT7475
Enhanced Acoustics Register 1 (0x62)
Bit 6 (MIN2) = 1, PWM2 runs at PWM2 minimum duty
cycle below TMIN − THYST.
Bit 5 (MIN1) = 0, PWM1 is off (0% PWM duty cycle) when
temperature is below TMIN − THYST.
Bit 5 (MIN1) = 1, PWM1 runs at PWM1 minimum duty
cycle below TMIN − THYST.
Bit 7 (MIN3) = 0, PWM3 is off (0% PWM duty cycle) when
temperature is below TMIN − THYST.
Bit 7 (MIN3) = 1, PWM3 runs at PWM3 minimum duty
cycle below TMIN − THYST.
Bit 6 (MIN2) = 0, PWM2 is off (0% PWM duty cycle) when
temperature is below TMIN − THYST.
PWM DUTY CYCLE
100%
0%
TMIN
THERMAL CALIBRATION
PWM
MIN
100%
PWM
CONFIG
PWM
GENERATOR
TMIN
REMOTE 2 =
CPU TEMP
TRANGE
THERMAL CALIBRATION
0%
PWM
MIN
100%
TMIN
LOCAL =
VRM TEMP
TRANGE
THERMAL CALIBRATION
TACHOMETER 1
MEASUREMENT
PWM
CONFIG
PWM
GENERATOR
MUX
0%
PWM
MIN
100%
PWM
CONFIG
TRANGE
CPU FAN SINK
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
PWM2
TACH2
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
TACHOMETER 3
AND 4
MEASUREMENT
0%
PWM1
TACH1
TACHOMETER 2
MEASUREMENT
PWM
GENERATOR
TMIN
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
FRONT CHASSIS
PWM3
TACH3
REMOTE 1 =
AMBIENT TEMP
REAR CHASSIS
Figure 48. Understanding the TMIN Parameter
Step 4: PWMMIN for Each PWM (Fan) Output
PWMMIN is the minimum PWM duty cycle at which each
fan in the system runs. It is also the start speed for each fan
under automatic fan control once the temperature rises
above TMIN. For maximum system acoustic benefit,
PWMMIN should be as low as possible. Depending on the
fan used, the PWMMIN setting is usually in the 20% to 33%
duty cycle range. This value can be found through fan
validation.
PWM DUTY CYCLE
100%
PWMMIN
0%
TMIN
TEMPERATURE
Figure 49. PWMMIN Determines Minimum
PWM Duty Cycle
http://onsemi.com
33
ADT7475
Given a PWM square wave as the drive signal, fan speed in
RPM approximates to:
More than one PWM output can be controlled from a
single temperature measurement channel. For example,
Remote 1 temperature can control PWM1 and PWM2
outputs. If two different fans are used on PWM1 and PWM2,
the fan characteristics can be set up differently. As a result,
Fan 1 driven by PWM1 can have a different PWMMIN value
than Fan 2 connected to PWM2. Figure 50 illustrates this as
PWM1MIN (front fan) turns on at a minimum duty cycle of
20%, while PWM2MIN (rear fan) turns on at a minimum of
40% duty cycle. Note that both fans turn on at exactly the
same temperature, defined by TMIN.
% fanspeed + ǸPWM duty cycle
PWMMAX is the maximum duty cycle that each fan in the
system runs at under the automatic fan speed control loop.
For maximum system acoustic benefit, PWMMAX should be
as low as possible but should be capable of maintaining the
processor temperature limit at an acceptable level. If the
THERM temperature limit is exceeded, the fans are still
boosted to 100% for fail−safe cooling.
There is a PWMMAX limit for each fan channel. The
default value of all PWMMAX registers is 0xFF.
100%
PWM1
PWM DUTY CYCLE
PWM DUTY CYCLE
PWM2
PWM1MIN
0%
TMIN
(eq. 4)
Step 5: PWMMAX for PWM (Fan) Outputs
100%
PWM2MIN
10
TEMPERATURE
Figure 50. Operating Two Different Fans from a
Single Temperature Channel
PWMMAX
PWMMIN
0%
TMIN
Programming the PWMMIN Registers
The PWMMIN registers are 8−bit registers that allow the
minimum PWM duty cycle for each output to be configured
anywhere from 0% to 100%. This allows the minimum
PWM duty cycle to be set in steps of 0.39%.
The value to be programmed into the PWMMIN register is
given by:
Value (decimal) = PWMMIN /0.39
Example 1: For a minimum PWM duty cycle of 50%,
Value (decimal) = 50/0.39 = 128 (decimal)
Value = 128 (decimal) or 80 (hex)
Example 2: For a minimum PWM duty cycle of 33%,
Value (decimal) = 33/0.39 = 85 (decimal)
Value = 85 (decimal) or 54 (hex)
TEMPERATURE
Figure 51. PWMMAX Determines Maximum PWM Duty
Cycle Below the THERM Temperature Limit
Programming the PWMMAX Registers
The PWMMAX registers are 8−bit registers that allow the
maximum PWM duty cycle for each output to be configured
anywhere from 0% to 100%. This allows the maximum
PWM duty cycle to be set in steps of 0.39%.
The value to be programmed into the PWMMAX register
is given by:
Value (decimal) = PWMMAX/0.39
Example 1: For a maximum PWM duty cycle of 50%,
Value (decimal) − 50/0.39 = 128 (decimal)
Value = 128 (decimal) or 80 (hex)
Example 2: For a minimum PWM duty cycle of 75%,
Value (decimal) = 75/0.39 = 192 (decimal)
Value = 192 (decimal) or C0 (hex)
PWMMIN Registers
Register 0x64, PWM1 Minimum Duty Cycle = 0x80
(50% default)
Register 0x65, PWM2 Minimum Duty Cycle = 0x80
(50% default)
Register 0x66, PWM3 Minimum Duty Cycle = 0x80
(50% default)
PWMMAX Registers
Register 0x38, PWM1 Maximum DutyCycle = 0xFF
(100% default)
Register 0x39, PWM2 Maximum Duty Cycle = 0xFF
(100% default)
Register 0x3A, PWM3 Maximum Duty Cycle = 0xFF
(100% default)
Note on Fan Speed and PWM Duty Cycle
The PWM duty cycle does not directly correlate to fan
speed in RPM. Running a fan at 33% PWM duty cycle does
not equate to running the fan at 33% speed. Driving a fan at
33% PWM duty cycle actually runs the fan at closer to 50%
of its full speed. This is because fan speed in %RPM
generally relates to the square root of the PWM duty cycle.
http://onsemi.com
34
ADT7475
Step 6: TRANGE for Temperature Channels
TRANGE is the range of temperature over which automatic
fan control occurs once the programmed TMIN temperature
has been exceeded. TRANGE is the temperature range
between PWMMIN and 100% PWM where the fan speed
changes linearly. Otherwise stated, it is the line drawn
between the TMIN/PWMMIN and the (TMIN + TRANGE)
/PWM 100% intersection points.
PWM DUTY CYCLE
100%
10%
0%
TRANGE
TMIN – HYST
PWM DUTY CYCLE
100%
305C
405C
455C
545C
TMIN
Figure 54. Increasing TRANGE Changes the AFC Slope
PWMMIN
100%
TMIN
PWM DUTY CYCLE
0%
TEMPERATURE
Figure 52. TRANGE Parameter Affects Cooling Slope
The TRANGE is determined by the following procedure:
1. Determine the maximum operating temperature for
that channel (for example, 70°C).
2. Determine, experimentally, the fan speed (PWM
duty cycle value) that does not exceed the
temperature at the worst−case operating points.
(For example, 70°C is reached when the fans are
running at 50% PWM duty cycle.)
3. Determine the slope of the required control loop to
meet these requirements.
4. Using the ADT7475 evaluation software,
graphically program and visualize this
functionality.
As PWMMIN is changed, the automatic fan control slope
also changes.
10%
0%
TRANGE
TMIN – HYST
Figure 55. Changing PWMMAX Does Not Change the
AFC Slope
Selecting TRANGE
The TRANGE value can be selected for each temperature
channel: Remote 1, local, and Remote 2 temperatures. Bits
[7:4] (RANGE) of Register 0x5F to Register 0x61 define the
TRANGE value for each temperature channel.
Table 10. Selecting a TRANGE Value
Bits [7:4] (Note 1)
100%
PWM DUTY CYCLE
MAX
PWM
50%
TRANGE (5C)
0000
2
0001
2.5
0010
3.33
0011
4
0100
5
0101
6.67
33%
0110
8
0%
0111
10
1000
13.33
1001
16
305C
TMIN
Figure 53. Adjusting PWMMIN Changes the Automatic
Fan Control Slope
As TRANGE is changed, the slope also changes. As
TRANGE gets smaller, the fans reach 100% speed with a
smaller temperature change.
1010
20
1011
26.67
1100
32 (default)
1101
40
1110
53.33
1111
80
1. Register 0x5F configures Remote 1 TRANGE; Register 0x60
configures local TRANGE; Register 0x61 configures Remote 2
TRANGE.
http://onsemi.com
35
ADT7475
Actual Changes in PWM Output (Advanced
Acoustics Settings)
100
PWM DUTY CYCLE (%)
0
0
PWM DUTY CYCLE (%)
FAN SPEED (% OF MAX)
0
0
3.335C
FAN SPEED (% OF MAX)
45C
55C
70
85C
13.35C
165C
40
205C
30
26.65C
325C
20
405C
10
0
0
53.35C
20
40
60
80
TEMPERATURE ABOVE TMIN
100
120
25C
2.55C
3.335C
45C
55C
6.675C
85C
105C
13.35C
165C
205C
26.65C
325C
405C
53.35C
20
40
60
80
TEMPERATURE ABOVE TMIN
100
120
805C
The following example shows how the different TMIN and
TRANGE settings can be applied to three different thermal
zones. In this example, the following TRANGE values apply:
TRANGE = 80°C for ambient temperature
TRANGE = 53.33°C for CPU temperature
TRANGE = 40°C for VRM temperature
This example uses the mux configuration described in
Step 2: Configuring the Mux, with the ADT7475 connected
as shown in Figure 47. Both CPU temperature and VRM
temperature drive the CPU fan connected to PWM1.
105C
50
805C
Example: Determining TRANGE for Each Temperature
Channel
6.675C
60
120
The graphs in Figure 56 assume that the fan starts from 0%
PWM duty cycle. Clearly, the minimum PWM duty cycle,
PWMMIN, needs to be factored in to see how the loop
actually performs in the system. Figure 57 shows how
TRANGE is affected when the PWMMIN value is set to 20%.
It can be seen that the fan actually runs at about 45% fan
speed when the temperature exceeds TMIN.
805C
25C
80
100
Figure 57. TRANGE and % Fan Speed Slopes with
PWMMIN = 20%
2.55C
90
40
60
80
TEMPERATURE ABOVE TMIN
(B)
(A)
100
53.35C
20
30
10
53.35C
120
405C
40
6.675C
405C
100
325C
50
20
325C
40
60
80
TEMPERATURE ABOVE T
MIN
26.65C
60
55C
26.65C
20
205C
70
165C
10
165C
30
80
205C
20
13.35C
40
90
13.35C
30
105C
100
105C
40
85C
50
(A)
85C
50
6.675C
60
0
0
45C
60
55C
70
10
3.335C
70
45C
20
2.55C
80
3.335C
80
25C
90
2.55C
90
While the automatic fan control algorithm describes the
general response of the PWM output, the enhanced acoustics
registers (0x62 and 0x63) can be used to set/clamp the
maximum rate of change of PWM output for a given
temperature zone. This means if TRANGE is programmed
with a steep AFC slope, a relatively small change in
temperature can cause a large change in PWM output and an
audible change in fan speed, which may be noticeable/
annoying to users. Decreasing the PWM output’s maximum
rate of change, by programming the smoothing on the
appropriate temperature channels (Register 0x62 and
Register 0x63), clamps the fan speed’s maximum rate of
change in the event of a temperature spike. The PWM duty
cycle increases slowly until the PWM duty cycle reaches the
appropriate duty cycle as defined by the AFC curve.
Figure 56 shows PWM duty cycle versus temperature for
each TRANGE setting. The lower graph shows how each
TRANGE setting affects fan speed vs. temperature. As can be
seen from the graph, the effect on fan speed is non−linear.
100
25C
805C
(B)
Figure 56. TRANGE vs. Actual Fan Speed (not PWM
Drive) Profile
http://onsemi.com
36
ADT7475
Ambient temperature drives the front chassis fan and rear
chassis fan connected to PWM2 and PWM3. The front
chassis fan is configured to run at PWMMIN = 20%. The rear
chassis fan is configured to run at PWMMIN = 30%. The
CPU fan is configured to run at PWMMIN = 10%.
Note that the control range for 4−wire fans is much wider
than that for 3−wire fans. In many cases, 4−wire fans can
start with a PWM drive of as little as 20% or less. In extreme
cases, some 3−wire fans do not run unless a PWM drive of
60% or more is applied.
number programmed into the hysteresis registers (0x6D and
0x6E). The default hysteresis value is 4°C.
The TTHERM limit should be considered the maximum
worst−case operating temperature of the system. Because
exceeding any TTHERM limit runs all fans at 100%, it has
very negative acoustic effects. Ultimately, this limit should
be set up as a fail−safe, and the designer should ensure that
it is not exceeded under normal system operating conditions.
Note that TTHERM limits are non−maskable and affect the
fan speed no matter how automatic fan control settings are
configured. This allows some flexibility because a TRANGE
value can be selected based on its slope, while a hard limit
(such as 70°C) can be programmed as TMAX (the
temperature at which the fan reaches full speed) by setting
TTHERM to that limit (for example, 70°C).
100
VRM TEMPERATURE
90
PWM DUTY CYCLE (%)
80
70
CPU TEMPERATURE
60
THERM Registers
50
Register 0x6A, Remote 1 THERM Temperature Limit = 0x64
(100°C default)
Register 0x6B, Local THERM Temperature Limit = 0x64
(100°C default)
Register 0x6C, Remote 2 THERM Temperature Limit = 0x64
(100°C default)
AMBIENT TEMPERATURE
40
30
20
10
0
0
10
20
30
40
50
60
70
80
90
100
TEMPERATURE ABOVE TMIN
100
THERM Hysteresis
THERM hysteresis on a particular channel is configured
via the hysteresis settings in Register 0x6D and Register
0x6E. For example, setting hysteresis on the Remote 1
channel also sets the hysteresis on Remote 1 THERM.
VRM TEMPERATURE
90
FAN SPEED (% MAX RPM)
80
70
CPU TEMPERATURE
60
Hysteresis Registers
AMBIENT TEMPERATURE
Register 0x6D, Remote 1 and Local Temperature/TMIN
Hysteresis Register
Bits [7:4] (HYSR1), Remote 1 Temperature Hysteresis
(4°C default)
Bits [3:0] (HYSL), Local Temperature Hysteresis
(4°C default)
Register 0x6E, Remote 2 Temperature TMIN Hysteresis
Register
Bits [7:4] (HYSR2), Remote 2 Temperature Hysteresis
(4°C default)
Because each hysteresis setting is four bits, hysteresis
values are programmable from 1°C to 15°C. It is not
recommended that hysteresis values ever be programmed to
0°C because this disables hysteresis. In effect, this causes the
fans to cycle (during a THERM event) between normal
speed and 100% speed or, while operating close to TMIN,
between normal speed and off, creating unsettling acoustic
noise.
50
40
30
20
10
0
0
10
20
30
40
50
60
70
80
90
100
TEMPERATURE ABOVE TMIN
Figure 58. TRANGE and % Fan Speed Slopes for VRM,
Ambient, and CPU Temperature Channels
Step 7: TTHERM for Temperature Channels
TTHERM is the absolute maximum temperature allowed
on a temperature channel. Above this temperature, a
component such as the CPU or VRM might be operating
beyond its safe operating limit. When the temperature
measured exceeds TTHERM, all fans drive at 100% PWM
duty cycle (full speed) to provide critical system cooling.
The fans remain running at 100% until the temperature
drops below TTHERM − hysteresis, where hysteresis is the
http://onsemi.com
37
ADT7475
TRANGE
PWM DUTY CYCLE
100%
0%
TMIN
TTHERM
THERMAL CALIBRATION
PWM
MIN
100%
PWM
CONFIG
PWM
GENERATOR
TMIN
REMOTE 2 =
CPU TEMP
TRANGE
THERMAL CALIBRATION
0%
PWM
MIN
100%
TACHOMETER 1
MEASUREMENT
PWM
CONFIG
PWM
GENERATOR
MUX
TMIN
LOCAL =
VRM TEMP
TRANGE
THERMAL CALIBRATION
0%
PWM
MIN
100%
PWM
CONFIG
TRANGE
CPU FAN SINK
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
PWM2
TACH2
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
TACHOMETER 3
AND 4
MEASUREMENT
0%
PWM1
TACH1
TACHOMETER 2
MEASUREMENT
PWM
GENERATOR
TMIN
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
FRONT CHASSIS
PWM3
TACH3
REMOTE 1 =
AMBIENT TEMP
REAR CHASSIS
Figure 59. How TTHERM Relates to Automatic Fan Control
Step 8: THYST for Temperature Channels
TTHERM hysteresis value, described in Step 6: TRANGE for
Temperature Channels. Therefore, programming Register
0x6D and Register 0x6E sets the hysteresis for both fan
on/off and the THERM function.
In some applications, it is required that fans not turn off
below TMIN but remain running at PWMMIN. Bits [7:5] of
Enhanced Acoustics Register 1 (0x62) allow the fans to be
turned off or to be kept spinning below TMIN. If the fans are
always on, the THYST value has no effect on the fan when the
temperature drops below TMIN.
THYST is the amount of extra cooling a fan provides after
the temperature measured has dropped back below TMIN
before the fan turns off. The premise for temperature
hysteresis (THYST) is that, without it, the fan would merely
chatter, or cycle on and off regularly, whenever the
temperature is hovering at about the TMIN setting.
The THYST value chosen determines the amount of time
needed for the system to cool down or heat up as the fan turns
on and off. Values of hysteresis are programmable in the
range 1°C to 15°C. Larger values of THYST prevent the fans
from chattering on and off. The THYST default value is set
at 4°C.
The THYST setting applies not only to the temperature
hysteresis for fan on/off, but the same setting is used for the
THERM Hysteresis
Any hysteresis programmed via Register 0x6D and
Register 0x6E also applies to hysteresis on the appropriate
THERM channel.
http://onsemi.com
38
ADT7475
TRANGE
PWM DUTY CYCLE
100%
0%
TTHERM
TMIN
THERMAL CALIBRATION
PWM
MIN
100%
PWM
CONFIG
PWM
GENERATOR
TMIN
REMOTE 2 =
CPU TEMP
TRANGE
THERMAL CALIBRATION
0%
PWM
MIN
100%
TACHOMETER 1
MEASUREMENT
PWM
CONFIG
PWM
GENERATOR
MUX
TMIN
LOCAL =
VRM TEMP
TRANGE
THERMAL CALIBRATION
0%
PWM
MIN
100%
PWM
CONFIG
TRANGE
CPU FAN SINK
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
PWM2
TACH2
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
TACHOMETER 3
AND 4
MEASUREMENT
0%
PWM1
TACH1
TACHOMETER 2
MEASUREMENT
PWM
GENERATOR
TMIN
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
FRONT CHASSIS
PWM3
TACH3
REMOTE 1 =
AMBIENT TEMP
REAR CHASSIS
Figure 60. The THYST Value Applies to Fan On/Off Hysteresis and THERM Hysteresis
Enhanced Acoustics Register 1 (0x62)
Configuration Register 6 (0x10)
Bit 7 (MIN3) = 0, PWM3 is off (0% PWM duty cycle) when
temperature is below TMIN − THYST.
Bit 7 (MIN3) = 1, PWM3 runs at PWM3 minimum duty
cycle below TMIN − THYST.
Bit 6 (MIN2) = 0, PWM2 is off (0% PWM duty cycle) when
temperature is below TMIN − THYST.
Bit 6 (MIN2) = 1, PWM2 runs at PWM2 minimum duty
cycle below TMIN − THYST.
Bit 5 (MIN1) = 0, PWM1 is off (0% PWM duty cycle) when
temperature is below TMIN − THYST.
Bit 5 (MIN1) = 1, PWM1 runs at PWM1 minimum duty
cycle below TMIN − THYST.
Bit 0 (SLOW Remote 1), 1 slows the ramp rate for PWM
changes associated with the Remote 1 temperature channel
by 4.
Bit 1 (SLOW Local), 1 slows the ramp rate for PWM
changes associated with the Local temperature channel by 4.
Bit 2 (SLOW Remote 2), 1 slows the ramp rate for PWM
changes associated with the Remote 2 temperature channel
by 4.
Bit 7 (ExtraSlow), 1 slows the ramp rate for all fans by a
factor of 39.2%.
The following sections list the ramp−up times when the
SLOW bit is set for each temperature monitoring channel.
http://onsemi.com
39
ADT7475
Enhanced Acoustics Register 1 (0x62)
Bits [6:4] (ACOU2), select the ramp rate for PWM outputs
associated with the Remote 2 temperature input.
000 = 37.5 sec
001 = 18.8 sec
010 = 12.5 sec
011 = 7.5 sec
100 = 4.7 sec
101 = 3.1 sec
110 = 1.6 sec
111 = 0.8 sec
When Bit 7 of Configuration Register 6 (0x10) = 1, the ramp
rates change to the following values:
000 = 52.2 sec
001 = 26.1 sec
010 = 17.4 sec
011 = 10.4 sec
100 = 6.5 sec
101 = 4.4 sec
110 = 2.2 sec
111 = 1.1 sec
Setting the appropriate SLOW bits [2:0] of Configuration
Register 6 (0x10) slows the ramp rate further by a factor of 4.
Bits [2:0] (ACOU1), select the ramp rate for PWM outputs
associated with the Remote 1 temperature input.
000 = 37.5 sec
001 = 18.8 sec
010 = 12.5 sec
011 = 7.5 sec
100 = 4.7 sec
101 = 3.1 sec
110 = 1.6 sec
111 = 0.8 sec
Enhanced Acoustics Register 2 (0x63)
Bits [2:0] (ACOU3), select the ramp rate for PWM outputs
associated with the local temperature channel.
000 = 37.5 sec
001 = 18.8 sec
010 = 12.5 sec
011 = 7.5 sec
100 = 4.7 sec
101 = 3.1 sec
110 = 1.6 sec
111 = 0.8 sec
http://onsemi.com
40
ADT7475
Register Tables
Table 11. ADT7475 Registers
Addr
R/W
Desc
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Default
0x10
R/W
Configuration
Register 6
Extra
Slow
VCCP
Low
RES
RES
THERM
in Manual
SLOW
Remote 2
SLOW
Local
SLOW
Remote 1
0x00
0x11
R
Configuration
Register 7
RES
RES
RES
RES
RES
RES
RES
Dis
THERM
Hys
0x00
0x21
R
VCCP
Reading
9
8
7
6
5
4
3
2
0x00
0x22
R
VCC Reading
9
8
7
6
5
4
3
2
0x00
0x25
R
Remote 1
Temp
9
8
7
6
5
4
3
2
0x80
0x26
R
Local Temp
9
8
7
6
5
4
3
2
0x80
0x27
R
Remote 2
Temp
9
8
7
6
5
4
3
2
0x80
0x28
R
TACH1 Low
Byte
7
6
5
4
3
2
1
0
0x00
0x29
R
TACH1 High
Byte
15
14
13
12
11
10
9
8
0x00
0x2A
R
TACH2 Low
Byte
7
6
5
4
3
2
1
0
0x00
0x2B
R
TACH2 High
Byte
15
14
13
12
11
10
9
8
0x00
0x2C
R
TACH3 Low
Byte
7
6
5
4
3
2
1
0
0x00
0x2D
R
TACH3 High
Byte
15
14
13
12
11
10
9
8
0x00
0x2E
R
TACH4 Low
Byte
7
6
5
4
3
2
1
0
0x00
0x2F
R
TACH4 High
Byte
15
14
13
12
11
10
9
8
0x00
0x30
R/W
PWM1
Current Duty
Cycle
7
6
5
4
3
2
1
0
0x00
0x31
R/W
PWM2
Current Duty
Cycle
7
6
5
4
3
2
1
0
0x00
0x32
R/W
PWM3
Current Duty
Cycle
7
6
5
4
3
2
1
0
0x00
0x38
R/W
PWM1 Max
Duty Cycle
7
6
5
4
3
2
1
0
0xFF
0x39
R/W
PWM2 Max
Duty Cycle
7
6
5
4
3
2
1
0
0xFF
0x3A
R/W
PWM3 Max
Duty Cycle
7
6
5
4
3
2
1
0
0xFF
0x3D
R
Device ID
Reg
7
6
5
4
3
2
1
0
0x75
0x3E
R
Company ID
Number
7
6
5
4
3
2
1
0
0x41
0x40
R/W
Config Reg 1
RES
TODIS
FSPDIS
Vx1
FSPD
RDY
LOCK
STRT
0x04
0x41
R
Interrupt
Status Reg 1
OOL
R2T
LT
R1T
RES
VCC
VCCP
RES
0x00
0x42
R
Interrupt
Status Reg 2
D2
D1
F4P
FAN3
FAN2
FAN1
OVT
RES
0x00
0x46
R/W
VCCP Low
Limit
7
6
5
4
3
2
1
0
0x00
0x47
R/W
VCCP High
Limit
7
6
5
4
3
2
1
0
0xFF
0x48
R/W
VCC Low
Limit
7
6
5
4
3
2
1
0
0x00
http://onsemi.com
41
Lockable
Yes
ADT7475
Table 11. ADT7475 Registers
Addr
R/W
Desc
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Default
0x49
R/W
VCC High
Limit
7
6
5
4
3
2
1
0
0xFF
0x4E
R/W
Remote 1
Temp Low
Limit
7
6
5
4
3
2
1
0
0x81
0x4F
R/W
Remote 1
Temp High
Limit
7
6
5
4
3
2
1
0
0x7F
0x50
R/W
Local Temp
Low Limit
7
6
5
4
3
2
1
0
0x81
0x51
R/W
Local Temp
High Limit
7
6
5
4
3
2
1
0
0x7F
0x52
R/W
Remote 2
Temp Low
Limit
7
6
5
4
3
2
1
0
0x81
0x53
R/W
Remote 2
Temp High
Limit
7
6
5
4
3
2
1
0
0x7F
0x54
R/W
TACH1
Minimum
Low Byte
7
6
5
4
3
2
1
0
0xFF
0x55
R/W
TACH1 Min
High Byte
15
14
13
12
11
10
9
8
0xFF
0x56
R/W
TACH2
Minimum
Low Byte
7
6
5
4
3
2
1
0
0xFF
0x57
R/W
TACH2 Min
High Byte
15
14
13
12
11
10
9
8
0xFF
0x58
R/W
TACH3
Minimum
Low Byte
7
6
5
4
3
2
1
0
0xFF
0x59
R/W
TACH3 Min
High Byte
15
14
13
12
11
10
9
8
0xFF
0x5A
R/W
TACH4
Minimum
Low Byte
7
6
5
4
3
2
1
0
0xFF
0x5B
R/W
TACH4 Min
High Byte
15
14
13
12
11
10
9
8
0xFF
0x5C
R/W
PWM1
Configuration
Register
BHVR
BHVR
BHVR
INV
RES
SPIN
SPIN
SPIN
0x62
Yes
0x5D
R/W
PWM2
Configuration
Register
BHVR
BHVR
BHVR
INV
RES
SPIN
SPIN
SPIN
0x62
Yes
0x5E
R/W
PWM3
Config
Register
BHVR
BHVR
BHVR
INV
RES
SPIN
SPIN
SPIN
0x62
Yes
0x5F
R/W
Remote 1
TRANGE/
PWM1 Freq
RANGE
RANGE
RANGE
RANGE
HF/LF
FREQ
FREQ
FREQ
0xC4
Yes
0x60
R/W
Local
TRANGE/
PWM2 Freq
RANGE
RANGE
RANGE
RANGE
HF/LF
FREQ
FREQ
FREQ
0xC4
Yes
0x61
R/W
Remote 2
TRANGE/
PWM3 Freq
RANGE
RANGE
RANGE
RANGE
HF/LF
FREQ
FREQ
FREQ
0xC4
Yes
0x62
R/W
Enhanced
Acoustics
Reg 1
MIN3
MIN2
MIN1
SYNC
EN1
ACOU1
ACOU1
ACOU1
0x00
Yes
0x63
R/W
Enhanced
Acoustics
Reg 2
EN2
ACOU2
ACOU2
ACOU2
EN3
ACOU3
ACOU3
ACOU3
0x00
Yes
0x64
R/W
PWM1 Min
Duty Cycle
7
6
5
4
3
2
1
0
0x80
Yes
http://onsemi.com
42
Lockable
ADT7475
Table 11. ADT7475 Registers
Addr
R/W
Desc
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Default
Lockable
0x65
R/W
PWM2 Min
Duty Cycle
7
6
5
4
3
2
1
0
0x80
Yes
0x66
R/W
PWM3 Min
Duty Cycle
7
6
5
4
3
2
1
0
0x80
Yes
0x67
R/W
Remote 1
Temp TMIN
7
6
5
4
3
2
1
0
0x5A
Yes
0x68
R/W
Local Temp
TMIN
7
6
5
4
3
2
1
0
0x5A
Yes
0x69
R/W
Remote 2
Temp TMIN
7
6
5
4
3
2
1
0
0x5A
Yes
0x6A
R/W
Remote 1
THERM
Temp Limit
7
6
5
4
3
2
1
0
0x64
Yes
0x6B
R/W
Local
THERM
Temp Limit
7
6
5
4
3
2
1
0
0x64
Yes
0x6C
R/W
Remote 2
THERM
Temp Limit
7
6
5
4
3
2
1
0
0x64
Yes
0x6D
R/W
Remote 1
and Local
Temp/TMIN
Hysteresis
HYSR1
HYSR1
HYSR1
HYSR1
HYSL
HYSL
HYSL
HYSL
0x44
Yes
0x6E
R/W
Remote 2
Temp/TMIN
Hysteresis
HYSR2
HYSR2
HYSR2
HYSR2
RES
RES
RES
RES
0x40
Yes
0x6F
R/W
XNOR Tree
Test Enable
RES
RES
RES
RES
RES
RES
RES
XEN
0x00
Yes
0x70
R/W
Remote 1
Temp Offset
7
6
5
4
3
2
1
0
0x00
Yes
0x71
R/W
Local Temp
Offset
7
6
5
4
3
2
1
0
0x00
Yes
0x72
R/W
Remote 2
Temp Offset
7
6
5
4
3
2
1
0
0x00
Yes
0x73
R/W
Config Reg 2
SHDN
CONV
ATTN
AVG
RES
RES
RES
RES
0x00
Yes
0x74
R/W
Interrupt
Mask Reg 1
OOL
R2T
LT
R1T
RES
VCC
VCCP
RES
0x00
0x75
R/W
Interrupt
Mask Reg 2
D2
D1
F4P
FAN3
FAN2
FAN1
OVT
RES
0x00
0x76
R/W
Extended
Res 1
RES
RES
VCC
VCC
VCCP
VCCP
RES
RES
0x00
0x77
R/W
Extended
Res 2
TDM2
TDM2
LTMP
LTMP
TDM1
TDM1
RES
RES
0x00
0x78
R/W
Configuration
Reg 3
DC4
DC3
DC2
DC1
FAST
BOOST
THERM
ALERT
Enable
0x00
0x79
R
THERM
Timer Status
Register
TMR
TMR
TMR
TMR
TMR
TMR
TMR
ASRT/
TMRO
0x00
0x7A
R/W
THERM
Timer Limit
Register
LIMT
LIMT
LIMT
LIMT
LIMT
LIMT
LIMT
LIMT
0x00
0x7B
R/W
TACH
Pulses per
Revolution
FAN4
FAN4
FAN3
FAN3
FAN2
FAN2
FAN1
FAN1
0x55
0x7C
R/W
Configuration
Reg 5
R2
THERM
O/P
Only
Local
THERM
O/P
Only
R1
THERM
O/P
Only
RES
GPIOP
GPIOD
Temp
Offset
TWOS
COMPL
0x01
Yes
0x7D
R/W
Configuration
Reg 4
RES
RES
BpAtt
VCCP
RES
Max/
Full on
THERM
THERM
Disable
PIN9
FUNC
PIN9
FUNC
0x00
Yes
0x7E
R
Test Reg 1
Do not write to these registers
0x00
Yes
0x7F
R
Test Reg 2
Do not write to these registers
0x00
Yes
http://onsemi.com
43
Yes
ADT7475
Table 12. Register 0x10 — Configuration Register 6 (Power−On Default = 0x00) (Notes 1 and 2)
Bit No.
Mnemonic
R/W
Description
[0]
SLOW
Remote 1
R/W
When this bit is set, Fan 1 smoothing times are multiplied x4 for Remote 1 temperature channel
(as defined in Register 0x62).
[1]
SLOW
Local
R/W
When this bit is set, Fan 2 smoothing times are multiplied x4 for local temperature channel (as
defined in Register 0x63).
[2]
SLOW
Remote 2
R/W
When this bit is set, Fan 3 smoothing times are multiplied x4 for Remote 2 temperature channel
(as defined in Register 0x63).
[3]
THERM in
Manual
R/W
When this bit is set, THERM is enabled in manual mode. (Note 1)
[5:4]
Reserved
N/A
Reserved. Do not write to these bits.
[6]
VCCPLow
R/W
VCCPLO = 1. When the power is supplied from 3.3 V STANDBY and the core voltage (VCCP)
drops below its VCCP low limit value (Register 0x46), the following occurs:
Bit 1 in Interrupt Status Register 1 is set.
SMBALERT is generated, if enabled.
PROCHOT monitoring is disabled.
Everything is re−enabled once VCCP increases above the VCCP low limit.
When VCCP increases above the low limit:
PROCHOT monitoring is enabled.
Fans return to their programmed state after a spin−up cycle.
[7]
ExtraSlow
R/W
When this bit is set, all fan smoothing times are increased by a further 39.2%.
1. A THERM event always overrides any fan setting (even when fans are disabled).
2. This register becomes read−only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to this register fail.
Table 13. Register 0x11 — Configuration Register 7 (Power−On Default = 0x00) (Note 1)
Bit No.
Mnemonic
R/W
[0]
Dis
THERM
Hys
R/W
Setting this bit to 1 disables THERM hysteresis.
Description
[7:1]
Reserved
N/A
Reserved. Do not write to these bits
1. This register becomes read−only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to this register fail.
Table 14. Voltage Reading Registers (Power−On Default = 0x00) (Notes 1 and 2)
Register Address
R/W
Description
0x21
Read−only
Reflects the voltage measurement at the VCCP input on Pin 14 (8 MSBs of reading).
0x22
Read−only
Reflects the voltage measurement at the VCC input on Pin 3 (8 MSBs of reading).
1. If the extended resolution bits of these readings are also read, the extended resolution registers (Reg. 0x76, Reg. 0x77) must be read first.
Once the extended resolution registers are read, the associated MSB reading registers are frozen until read. Both the extended resolution
registers and the MSB registers are frozen.
2. VCC (Pin 3) is the supply voltage for the ADT7475.
Table 15. Temperature Reading Registers (Power−On Default = 0x80) (Notes 1 and 2)
Register Address
R/W
0x25
Read−only
Remote 1 temperature readingPP (8 MSBs of reading). (Notes 3 and 4)
Description
0x26
Read−only
Local temperature reading (8 MSBs of reading).
0x27
Read−only
Remote 2 temperature reading (8 MSBs of reading).
1. These temperature readings can be in twos complement or Offset 64 format; this interpretation is determined by Bit 0 of Configuration
Register 5 (0x7C).
2. If the extended resolution bits of these readings are also read, the extended resolution registers (0x76 and 0x77) must be read first. Once
the extended resolution registers are read, all associated MSB reading registers are frozen until read. Both the extended resolution registers
and the MSB registers are frozen.
3. In twos complement mode, a temperature reading of −128°C (0x80) indicates a diode fault (open or short) on that channel.
4. In Offset 64 mode, a temperature reading of −64°C (0x00) indicates a diode fault (open or short) on that channel.
http://onsemi.com
44
ADT7475
Table 16. Fan Tachometer Reading Registers (Power−On Default = 0x00) (Note 1)
Register Address
R/W
0x28
Read−only
TACH1 low byte.
Description
0x29
Read−only
TACH1 high byte.
0x2A
Read−only
TACH2 low byte.
0x2B
Read−only
TACH2 high byte.
0x2C
Read−only
TACH3 low byte.
0x2D
Read−only
TACH3 high byte.
0x2E
Read−only
TACH4 low byte.
0x2F
Read−only
TACH4 high byte.
1. These registers count the number of 11.11 ms periods (based on an internal 90 kHz clock) that occur between a number of consecutive fan TACH
pulses (default = 2). The number of TACH pulses used to count can be changed using the TACH pulses per revolution register (0x7B). This allows
the fan speed to be accurately measured. Because a valid fan tachometer reading requires that two bytes be read, the low byte must be read
first. Both the low and high bytes are then frozen until read. At power−on, these registers contain 0x0000 until the first valid fan TACH
measurement is read into these registers. This prevents false interrupts from occurring while the fans are spinning up.
A count of 0xFFFF indicates that a fan is one of the following:
• Stalled or blocked (object jamming the fan).
• Failed (internal circuitry destroyed).
• Not populated. (The ADT7475 expects to see a fan connected to each TACH. If a fan is not connected to that TACH, its TACH minimum
high and low bytes should be set to 0xFFFF.)
• Alternate function, for example, TACH4 reconfigured as a THERM pin.).
Table 17. Current PWM Duty Cycle Registers (Power−On Default = 0x00) (Note 1)
Register Address
R/W
Description
0x30
R/W
PWM1 current duty cycle (0% to 100% duty cycle = 0x00 to 0xFF).
0x31
R/W
PWM2 current duty cycle (0% to 100% duty cycle = 0x00 to 0xFF).
0x32
R/W
PWM3 current duty cycle (0% to 100% duty cycle = 0x00 to 0xFF).
1. These registers reflect the PWM duty cycle driving each fan at any given time. When in automatic fan speed control mode, the ADT7475
reports the PWM duty cycles back through these registers. The PWM duty cycle values vary according to temperature in automatic fan speed
control mode. During fan startup, these registers report back 0x00. In software mode, the PWM duty cycle outputs can be set to any duty
cycle value by writing to these registers.
Table 18. Maximum PWM Duty Cycle Registers (Power−On Default = 0xFF) (Notes 1 and 2)
Register Address
R/W
Description
0x38
R/W
Maximum duty cycle for PWM1 output, default = 100% (0xFF).
0x39
R/W
Maximum duty cycle for PWM2 output, default = 100% (0xFF).
0x3A
R/W
Maximum duty cycle for PWM3 output, default = 100% (0xFF).
1. This register becomes read−only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to this register fail.
2. These registers set the maximum PWM duty cycle of the PWM output.
http://onsemi.com
45
ADT7475
Table 19. Register 0x40 — Configuration Register 1 (Power−On Default = 0x04)
Bit No.
Mnemonic
R/W
Description
[0]
STRT
(Notes 1, 2)
R/W
Logic 1 enables monitoring and PWM control outputs based on the limit settings programmed.
Logic 0 disables monitoring and PWM control based on the default powerup limit settings.
Note that the limit values programmed are preserved even if a Logic 0 is written to this bit and the
default settings are enabled. This bit does not become locked once Bit 1 (LOCK) has been set.
[1]
LOCK
Write
Once
Logic 1 locks all limit values to their current settings. Once this bit is set, all lockable registers
become read−only and cannot be modified until the ADT7475 is powered down and powered
up again. This prevents rogue programs such as viruses from modifying critical system limit
settings. This bit is lockable.
[2]
RDY
Read−only
[3]
FSPD
R/W
When set to 1, this bit runs all fans at max speed as programmed in the PWM current duty
cycle registers (0x30 to 0x32). Power−on default = 0. This bit is not locked at any time.
[4]
Vx1
R/W
BIOS should set this bit to a 1 when the ADT7475 is configured to measure current from the
controller and to measure the CPU’s core voltage. This bit allows monitoring software to display
CPU watts usage. This bit is lockable.
[5]
FSPDIS
R/W
Logic 1 disables fan spin−up for two TACH pulses. Instead, the PWM outputs go high for the
entire fan spin−up timeout selected.
[6]
TODIS
R/W
When this bit is set to 1, the SMBus timeout feature is disabled. This allows the ADT7475 to be
used with SMBus controllers that cannot handle SMBus timeouts. This bit is lockable.
[7]
RES
This bit is set to 1 by the ADT7475 to indicate only that the device is fully powered up and ready
to begin system monitoring.
Reserved.
1. Bit 0 (STRT) of Configuration Register 1 (0x40) remains writable after the lock bit is set.
2. When monitoring is disabled, PWM outputs always go to 100% for thermal protection.
Table 20. Register 0x41 — Interrupt Status Register 1 (Power−On Default = 0x00)
Bit No.
Mnemonic
R/W
[1]
VCCP
Read−only
VCCP = 1 indicates that the VCCP high or low limit has been exceeded. This bit is cleared on a
read of the status register only if the error condition has subsided.
Description
[2]
VCC
Read−only
VCC = 1 indicates that the VCC high or low limit has been exceeded. This bit is cleared on a
read of the status register only if the error condition has subsided.
[4]
R1T
Read−only
R1T = 1 indicates that the Remote 1 low or high temperature has been exceeded. This bit is
cleared on a read of the status register only if the error condition has subsided.
[5]
LT
Read−only
LT = 1 indicates that the local low or high temperature has been exceeded. This bit is cleared
on a read of the status register only if the error condition has subsided.
[6]
R2T
Read−only
R2T = 1 indicates that the Remote 2 low or high temperature has been exceeded. This bit is
cleared on a read of the status register only if the error condition has subsided.
[7]
OOL
Read−only
OOL = 1 indicates that an out−of−limit event has been latched in Interrupt Status Register 2.
This bit is a logical OR of all status bits in Interrupt Status Register 2. Software can test this bit
in isolation to determine whether any of the voltage, temperature, or fan speed readings
represented by Interrupt Status Register 2 are out−of−limit, which saves the need to read
Interrupt Status Register 2 every interrupt or polling cycle.
http://onsemi.com
46
ADT7475
Table 21. Register 0x42 — Interrupt Status Register 2 (Power−On Default = 0x00)
Bit No.
Mnemonic
R/W
Description
[1]
OVT
Read−only
OVT = 1 indicates that one of the THERM overtemperature limits has been exceeded. This bit
is cleared on a read of the status register when the temperature drops below THERM – THYST.
[2]
FAN1
Read−only
FAN1 = 1 indicates that Fan 1 has dropped below minimum speed or has stalled. This bit is not
set when the PWM1 output is off.
[3]
FAN2
Read−only
FAN2 = 1 indicates that Fan 2 has dropped below minimum speed or has stalled. This bit is not
set when the PWM2 output is off.
[4]
FAN3
Read−only
FAN3 = 1 indicates that Fan 3 has dropped below minimum speed or has stalled. This bit is not
set when the PWM3 output is off.
[5]
F4P
Read−only
F4P = 1 indicates that Fan 4 has dropped below minimum speed or has stalled. This bit is not
set when the PWM3 output is off.
R/W
When Pin 9 is programmed as a GPIO output, writing to this bit determines the logic output of
the GPIO.
Read−only
If Pin 9 is configured as the THERM timer input for THERM monitoring, this bit is set when the
THERM assertion time exceeds the limit programmed in the THERM timer limit register (0x7A).
[6]
D1
Read−only
D1 = 1 indicates either an open or short circuit on the Thermal Diode 1 inputs.
[7]
D2
Read−only
D2 = 1 indicates either an open or short circuit on the Thermal Diode 2 inputs.
Table 22. Voltage Limit Registers (Note 1)
Register Address
R/W
0x46
R/W
VCCP low limit.
0x00
0x47
R/W
VCCP high limit.
0xFF
0x48
R/W
VCC low limit.
0x00
0x49
R/W
VCC high limit.
0xFF
Description (Note 2)
Power−On Default
1. Setting the Configuration Register 1 lock bit has no effect on these registers.
2. High limits: an interrupt is generated when a value exceeds its high limit (> comparison); low limits: an interrupt is generated when a value
is equal to or below its low limit (≤ comparison).
Table 23. Temperature Limit Registers (Note 1)
Register Address
R/W
0x4E
R/W
Remote 1 temperature low limit.
0x81
0x4F
R/W
Remote 1 temperature high limit.
0x7F
0x50
R/W
Local temperature low limit.
0x81
0x51
R/W
Local temperature high limit.
0x7F
0x52
R/W
Remote 2 temperature low limit.
0x81
0x53
R/W
Remote 2 temperature high limit.
0x7F
Description (Note 2)
Power−On Default
1. Exceeding any of these temperature limits by 1°C causes the appropriate status bit to be set in the interrupt status register. Setting the
Configuration Register 1 lock bit has no effect on these registers.
2. High limits: an interrupt is generated when a value exceeds its high limit (> comparison); low limits: an interrupt is generated when a value
is equal to or below its low limit (≤ comparison).
http://onsemi.com
47
ADT7475
Table 24. Fan Tachometer Limit Registers (Note 1)
Register Address
R/W
0x54
R/W
TACH1 minimum low byte.
Description
Power−On Default
0xFF
0x55
R/W
TACH1 minimum high byte/single−channel ADC channel select.
0xFF
0x56
R/W
TACH2 minimum low byte.
0xFF
0x57
R/W
TACH2 minimum high byte.
0xFF
0x58
R/W
TACH3 minimum low byte.
0xFF
0x59
R/W
TACH3 minimum high byte.
0xFF
0x5A
R/W
TACH4 minimum low byte.
0xFF
0x5B
R/W
TACH4 minimum high byte.
0xFF
1. Exceeding any of the TACH limit registers by 1 indicates that the fan is running too slowly or has stalled. The appropriate status bit is set
in Interrupt Status Register 2 to indicate the fan failure. Setting the Configuration Register 1 lock bit has no effect on these registers.
Table 25. Register 0x55 — TACH1 Minimum High Byte (Power−On Default = 0xFF)
Bit No.
Mnemonic
R/W
Description
[4:0]
Reserved
Read−only
These bits are reserved when Bit 6 of Configuration Register 2 (0x73) is set (single−channel ADC
mode). Otherwise, these bits represent Bits [4:0] of the TACH1 minimum high byte register.
[7:5]
SCADC
R/W
When Bit 6 of Configuration Register 2 (0x73) is set (single−channel ADC mode), these bits are
used to select the only channel from which the ADC makes measurements. Otherwise, these
bits represent Bits [7:5] of the TACH1 minimum high byte register.
Table 26. PWM Configuration Registers (Note 1)
Register Address
R/W
0x5C
R/W
PWM1 configuration.
Description
Power−On Default
0x62
0x5D
R/W
PWM2 configuration.
0x62
0x5E
R/W
PWM3 configuration.
0x62
1. These registers become read−only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to these registers fail.
Table 27. Register 0x05C, Register 0x5D, and Register 0x5E — PWM Configuration Registers
(Power−On Default = 0x62)
Bit No.
Mnemonic
R/W
Description
[2:0]
SPIN
R/W
These bits control the startup timeout for PWMx. The PWM output stays high until two valid
TACH rising edges are seen from the fan. If there is not a valid TACH signal during the fan
TACH measurement directly after the fan startup timeout period, the TACH measurement reads
0xFFFF and Interrupt Status Register 2 reflects the fan fault. If the TACH minimum high and low
bytes contain 0xFFFF or 0x0000, the Interrupt Status Register 2 bit is not set, even if the fan
has not started.
000 = No startup timeout
001 = 100 ms
010 = 250 ms (default)
011 = 400 ms
100 = 667 ms
101 = 1 sec
110 = 2 sec
111 = 4 sec
[4]
INV
R/W
This bit inverts the PWM output. The default is 0, which corresponds to a logic high output for
100% duty cycle. Setting this bit to 1 inverts the PWM output so that 100% duty cycle
corresponds to a logic low output.
[7:5]
BHVR
R/W
These bits assign each fan to a particular temperature sensor for localized cooling.
000 = Remote 1 temperature controls PWMx (automatic fan control mode).
001 = Local temperature controls PWMx (automatic fan control mode).
010 = Remote 2 temperature controls PWMx (automatic fan control mode).
011 = PWMx runs full speed.
100 = PWMx disabled (default).
101 = Fastest speed calculated by local and Remote 2 temperature controls PWMx.
110 = Fastest speed calculated by all three temperature channel controls PWMx.
111 = Manual Mode. PWM duty cycle registers (0x30 to 0x32) become writable.
http://onsemi.com
48
ADT7475
Table 28. Temp TRANGE/PWM Frequency Registers (Note 1)
Register Address
R/W
0x5F
R/W
Remote 1 TRANGE/PWM1 frequency.
Description
Power−On Default
0xC4
0x60
R/W
Local TRANGE/PWM2 frequency.
0xC4
0x61
R/W
Remote 2 TRANGE/PWM3 frequency.
0xC4
1. These registers become read−only when the Configuration Register 1 lock bit is set. Any subsequent attempts to write to these registers fail.
Table 29. Register 0x05F, Register 0x60, and Register 0x61 — Temp TRANGE/PWM Frequency Registers
(Power−On Default = 0xC4)
Bit No.
Mnemonic
R/W
[2:0]
FREQ
R/W
These bits control the PWMx frequency.
000 = 11.0 Hz
001 = 14.7 Hz
010 = 22.1 Hz
011 = 29.4 Hz
100 = 35.3 Hz (default)
101 = 44.1 Hz
110 = 58.8 Hz
111 = 88.2 Hz
Description
[3]
HF/LF
R/W
HF/LF =1, enables high frequency PWM output for 4−wire fans. Once enabled, 3−wire fan
specific settings have no effect (this means, pulse stretching).
[7:4]
RANGE
R/W
These bits determine the PWM duty cycle vs. the temperature slope for automatic fan control.
0000 = 2°C
0001 = 2.5°C
0010 = 3.33°C
0011 = 4°C
0100 = 5°C
0101 = 6.67°C
0110 = 8°C
0111 = 10°C
1000 = 13.33°C
1001 = 16°C
1010 = 20°C
1011 = 26.67°C
1100 = 32°C (default)
1101 = 40°C
1110 = 53.33°C
1111 = 80°C
http://onsemi.com
49
ADT7475
Table 30. Register 0x62 — Enhanced Acoustics Register 1 (Power−On Default = 0x00)
Bit No.
Mnemonic
R/W
(Note 1)
[2:0]
ACOU1
R/W
Description
Assuming that PWMx is associated with the Remote 1 temperature channel, these bits define
the maximum rate of change of the PWMx output for Remote 1 temperature related changes.
Instead of the fan speed jumping instantaneously to its newly determined speed, it ramps
gracefully at the rate determined by these bits. This feature ultimately enhances the acoustics
of the fan.
When Bit 7 of Configuration Register 6 (0x10) is 0
Time Slot Increase
000 = 1
001 = 2
010 = 3
011 = 4
100 = 8
101 = 12
110 = 24
111 = 48
Time for 0% to 100%
37.5 sec
18.8 sec
12.5 sec
7.5 sec
4.7 sec
3.1 sec
1.6 sec
0.8 sec
When Bit 7 of Configuration Register 6 (0x10) is 1
Time Slot Increase
000 = 1
001 = 2
010 = 3
011 = 4
100 = 8
101 = 12
110 = 24
111 = 48
Time for 0% to 100%
52.2 sec
26.1 sec
17.4 sec
10.4 sec
6.5 sec
4.4 sec
2.2 sec
1.1 sec
[3]
EN1
R/W
When this bit is 1, smoothing is enabled on the Remote 1 temperature channel.
[4]
SYNC
R/W
SYNC = 1 synchronizes fan speed measurements on TACH2, TACH3, and TACH4 to PWM3.
This allows up to three fans to be driven from PWM3 output and their speeds to be measured.
SYNC = 0 synchronizes only TACH3 and TACH4 to PWM3 output.
[5]
MIN1
R/W
When the ADT7475 is in automatic fan control mode, this bit defines whether PWM1 is off
(0% duty cycle) or at PWM1 minimum duty cycle when the controlling temperature is below its
TMIN – hysteresis value.
0 = 0% duty cycle below TMIN – hysteresis.
1 = PWM1 minimum duty cycle below TMIN – hysteresis.
[6]
MIN2
R/W
When the ADT7475 is in automatic fan speed control mode, this bit defines whether PWM2 is
off (0% duty cycle) or at PWM2 minimum duty cycle when the controlling temperature is below
its TMIN – hysteresis value.
0 = 0% duty cycle below TMIN – hysteresis.
1 = PWM 2 minimum duty cycle below TMIN – hysteresis.
[7]
MIN3
R/W
When the ADT7475 is in automatic fan speed control mode, this bit defines whether PWM3 is
off (0% duty cycle) or at PWM3 minimum duty cycle when the controlling temperature is below
its TMIN – hysteresis value.
0 = 0% duty cycle below TMIN – hysteresis.
1 = PWM3 minimum duty cycle below TMIN – hysteresis.
1. This register becomes read−only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to this register fail.
http://onsemi.com
50
ADT7475
Table 31. Register 0x63 — Enhanced Acoustics Register 2 (Power−On Default = 0x00)
Bit No.
Mnemonic
R/W
(Note 1)
Description
[2:0]
ACOU3
R/W
Assuming that PWMx is associated with the local temperature channel, these bits define the
maximum rate of change of the PWMx output for local temperature related changes. Instead of
the fan speed jumping instantaneously to its newly determined speed, it ramps gracefully at the
rate determined by these bits. This feature ultimately enhances the acoustics of the fan.
When Bit 7 of Configuration Register 6 (0x10) is 0
Time Slot Increase
000 = 1
001 = 2
010 = 3
011 = 4
100 = 8
101 = 12
110 = 24
111 = 48
Time for 0% to 100%
37.5 sec
18.8 sec
12.5 sec
7.5 sec
4.7 sec
3.1 sec
1.6 sec
0.8 sec
When Bit 7 of Configuration Register 6 (0x10) is 1
Time Slot Increase
000 = 1
001 = 2
010 = 3
011 = 4
100 = 8
101 = 12
110 = 24
111 = 48
Time for 0% to 100%
52.2 sec
26.1 sec
17.4 sec
10.4 sec
6.5 sec
4.4 sec
2.2 sec
1.1 sec
[3]
EN3
R/W
When this bit is 1, smoothing is enabled on the Local temperature channel.
[6:4]
ACOU2
R/W
Assuming that PWMx is associated with the Remote 2 temperature channel, these bits define
the maximum rate of change of the PWMx output for Remote 2 temperature related changes.
Instead of the fan speed jumping instantaneously to its newly determined speed, it ramps
gracefully at the rate determined by these bits. This feature ultimately enhances the acoustics
of the fan.
When Bit 7 of Configuration Register 6 (0x10) is 0
Time Slot Increase
000 = 1
001 = 2
010 = 3
011 = 4
100 = 8
101 = 12
110 = 24
111 = 48
Time for 0% to 100%
37.5 sec
18.8 sec
12.5 sec
7.5 sec
4.7 sec
3.1 sec
1.6 sec
0.8 sec
When Bit 7 of Configuration Register 6 (0x10) is 1
Time Slot Increase
000 = 1
001 = 2
010 = 3
011 = 4
100 = 8
101 = 12
110 = 24
111 = 48
[7]
EN2
R/W
Time for 0% to 100%
52.2 sec
26.1 sec
17.4 sec
10.4 sec
6.5 sec
4.4 sec
2.2 sec
1.1 sec
When this bit is 1, smoothing is enabled on the Remote 2 temperature channel.
1. This register becomes read−only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to this register fail.
Table 32. PWM Minimum Duty Cycle Registers (Note 1)
Register Address
R/W
0x64
R/W
PWM1 minimum duty cycle.
Description
0x80 (50% duty cycle)
0x65
R/W
PWM2 minimum duty cycle.
0x80 (50% duty cycle)
0x66
R/W
PWM3 minimum duty cycle.
0x80 (50% duty cycle)
1. These registers become read−only when the ADT7475 is in automatic fan control mode.
http://onsemi.com
51
Power−On Default
ADT7475
Table 33. Register 0x64, Register 0x65, Register 0x66 — PWM Minimum Duty Cycle Registers
(Power−On Default = 0x80; 50% Duty Cycle)
Bit No.
Mnemonic
R/W
[7:0]
PWM Duty
Cycle
R/W
Description
These bits define the PWMMIN duty cycle for PWMx.
0x00 = 0% duty cycle (fan off).
0x40 = 25% duty cycle.
0x80 = 50% duty cycle.
0xFF = 100% duty cycle (fan full speed).
Table 34. TMIN Registers (Note 1 and 2)
Register Address
R/W
Description
Power−On Default
0x67
R/W
Remote 1 temperature TMIN
0x5A (90°C)
0x68
R/W
Local temperature TMIN
0x5A (90°C)
0x69
R/W
Remote 2 temperature TMIN
0x5A (90°C)
1. These are the TMIN registers for each temperature channel. When the temperature measured exceeds TMIN, the appropriate fan runs at
minimum speed and increases with temperature according to TRANGE.
2. These registers become read−only when the Configuration Register 1 lock bit is set. Any subsequent attempts to write to these registers fail.
Table 35. THERM Temperature Limit Registers (Note 1)
Power−On Default
Register Address
R/W
(Note 2)
0x6A
R/W
Remote 1 THERM temperature limit.
0x64 (100°C)
0x6B
R/W
Local THERM temperature limit.
0x64 (100°C)
0x6C
R/W
Remote 2 THERM temperature limit.
0x64 (100°C)
Description
1. If any temperature measured exceeds its THERM limit, all PWM outputs drive their fans at 100% duty cycle. This is a fail−safe mechanism
incorporated to cool the system in the event of a critical overtemperature. It also ensures some level of cooling in the event that software
or hardware locks up. If set to 0x80, this feature is disabled. The PWM output remains at 100% until the temperature drops below a THERM
Limit − Hysteresis. If the THERM pin is programmed as an output, then exceeding these limits by 0.25°C can cause the THERM pin to assert
low as an output.
2. These registers become read−only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to these registers fail.
Table 36. Temperature/TMIN Hysteresis Registers (Note 1)
Register Address
R/W
(Note 2)
0x6D
R/W
Bit Name
Description
Power−On Default
Remote 1 and local temperature hysteresis.
Local temperature hysteresis. 0°C to 15°C of hysteresis
can be applied to the local temperature and AFC loops.
0x44
HYSL
[3:0]
HYSR1
[7:4]
0x6E
R/W
HYSR2
[7:4]
Remote 1 temperature hysteresis. 0°C to 15°C of
hysteresis can be applied to the Remote 1 temperature
and AFC loops.
Remote 2 temperature hysteresis.
Local temperature hysteresis. 0°C to 15°C of hysteresis
can be applied to the local temperature and AFC loops.
0x40
1. Each 4−bit value controls the amount of temperature hysteresis applied to a particular temperature channel. Once the temperature for that
channel falls below its TMIN value, the fan remains running at PWMMIN duty cycle until the temperature = TMIN − hysteresis. Up to 15°C of
hysteresis can be assigned to any temperature channel. The hysteresis value chosen also applies to that temperature channel, if its THERM
limit is exceeded. The PWM output being controlled goes to 100%, if the THERM limit is exceeded and remains at 100% until the temperature
drops below THERM − hysteresis. For acoustic reasons, it is recommended that the hysteresis value not be programmed to less than 4°C.
Setting the hysteresis value lower than 4°C causes the fan to switch on and off regularly when the temperature is close to TMIN.
2. These registers become read−only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to these registers fail.
http://onsemi.com
52
ADT7475
Table 37. XNOR Tree Test Enable Register
Register Address
R/W
(Note 1)
0x6F
R/W
Bit Name
Description
Power−On Default
XNOR tree test enable register.
If the XEN bit is set to 1, the device enters the XNOR
tree test mode. Clearing the bit removes the device from
the XNOR tree test mode.
0x00
XEN [0]
RES [7:1]
Unused. Do not write to these bits.
1. These registers become read−only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to these registers fail.
Table 38. Remote 1 Temperature Offset Register
Register Address
R/W
(Note 1)
Bit Name
Description
Power−On Default
0x70
R/W
[7:0]
Remote 1 temperature offset.
Allows a twos complement offset value to be
automatically added to or subtracted from the Remote 1
temperature reading. This is to compensate for any
inherent system offsets such as PCB trace resistance.
LSB value = 0.5°C.
0x00
1. These registers become read−only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to these registers fail.
Table 39. Local Temperature Offset Register
Register Address
R/W
(Note 1)
Bit Name
0x71
R/W
[7:0]
Description
Local temperature offset.
Allows a twos complement offset value to be
automatically added to or subtracted from the local
temperature reading. LSB value = 0.5°C.
Power−On Default
0x00
1. These registers become read−only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to these registers fail.
Table 40. Remote 2 Temperature Offset Register (Note 1)
Register Address
R/W
Bit Name
Description
Power−On Default
0x72
R/W
[7:0]
Remote 2 temperature offset.
Allows a twos complement offset value to be
automatically added to or subtracted from the Remote 2
temperature reading. This is to compensate for any
inherent system offsets such as PCB trace resistance.
LSB value = 0.5°C.
0x00
1. These registers become read−only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to these registers fail.
http://onsemi.com
53
ADT7475
Table 41. Register 0x73 — Configuration Register 2 (Power−On Default = 0x00)
Bit No.
Mnemonic
[0:3]
RES
[4]
AVG
R/W
AVG = 1, averaging on the temperature and voltage measurements is turned off. This allows
measurements on each channel to be made much faster.
[5]
ATTN
R/W
ATTN = 1, the ADT7475 removes the attenuators from the VCCP input. The VCCP input can be
used for other functions such as connecting up external sensors.
[6]
CONV
R/W
CONV = 1, the ADT7475 is put into a single−channel ADC conversion mode. In this mode, the
ADT7475 can be made to read continuously from one input only, for example, Remote 1
temperature. The appropriate ADC channel is selected by writing to Bits [7:5] of TACH1
minimum high byte register (0x55).
R/W
(Note 1)
Description
Reserved.
Register 0x55, Bits [7:5]
000
001
010
011
100
101
110
111
[7]
SHDN
R/W
Reserved
VCCP
VCC (3.3 V)
Reserved
Reserved
Remote 1 temperature
Local temperature
Remote 2 temperature
SHDN = 1, ADT7475 goes into shutdown mode. All PWM outputs assert low (or high depending
on state of the INV bit) to switch off all fans. The PWM current duty cycle registers read 0x00 to
indicate that the fans are not being driven.
1. These registers become read−only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to these registers fail.
Table 42. Register 0x74 — Interrupt Mask Register 1 (Power−On Default <7:0> = 0x00)
Bit No.
Mnemonic
R/W
Description
[1]
VCCP
R/W
VCCP = 1, masks SMBALERT for out−of−limit conditions on the VCCP channel.
[2]
VCC
R/W
VCC = 1, masks SMBALERT for out−of−limit conditions on the VCC channel.
[4]
R1T
R/W
R1T = 1, masks SMBALERT for out−of−limit conditions on the Remote 1 temperature channel.
[5]
LT
R/W
LT = 1, masks SMBALERT for out−of−limit conditions on the local temperature channel.
[6]
R2T
R/W
R2T = 1, masks SMBALERT for out−of−limit conditions on the Remote 2 temperature channel.
[7]
OOL
R/W
OOL = 0, when one or more alerts are generated in Interrupt Status Register 2, assuming that
all the mask bits in the Interrupt Mask Register 2 (0x75) = 1, SMBALERT is still asserted.
OOL = 1, when one or more alerts are generated in Interrupt Status Register 2, assuming that
all the mask bits in the Interrupt Mask Register 2 (0x75) = 1, SMBALERT is not asserted.
Table 43. Register 0x75 — Interrupt Mask Register 2 (Power−On Default <7:0> = 0x00)
Bit No.
Mnemonic
R/W
[1]
OVT
Read−only
Description
[2]
FAN1
R/W
FAN1 = 1, masks SMBALERT for a Fan 1 fault.
[3]
FAN2
R/W
FAN2 = 1, masks SMBALERT for a Fan 2 fault.
[4]
FAN3
R/W
FAN3 = 1, masks SMBALERT for a Fan 3 fault.
[5]
F4P
R/W
F4P = 1, masks SMBALERT for a Fan 4 fault. If the TACH4 pin is being used as the THERM
input, this bit masks SMBALERT for a THERM timer event.
[6]
D1
R/W
D1 = 1, masks SMBALERT for a diode open or short on a Remote 1 channel.
[7]
D2
R/W
D2 = 1, masks SMBALERT for a diode open or short on a Remote 2 channel.
OVT = 1, masks SMBALERT for overtemperature THERM conditions.
Table 44. Register 0x76 — Extended Resolution Register 1 (Note 1)
Bit No.
Mnemonic
R/W
Description
[3:2]
VCCP
R/W
VCCP LSBs. Holds the 2 LSBs of the 10−bit VCCP measurement.
[5:4]
VCC
R/W
VCC LSBs. Holds the 2 LSBs of the 10−bit VCC measurement.
1. If this register is read, this register and the registers holding the MSB of each reading are frozen until read.
http://onsemi.com
54
ADT7475
Table 45. Register 0x77 — Extended Resolution Register 2 (Note 1)
Bit No.
Mnemonic
R/W
Description
[3:2]
TDM1
R/W
Remote 1 temperature LSBs. Holds the 2 LSBs of the 10−bit Remote 1 temperature measurement.
[5:4]
LTMP
R/W
Local temperature LSBs. Holds the 2 LSBs of the 10−bit local temperature measurement.
[7:6]
TDM2
R/W
Remote 2 temperature LSBs. Holds the 2 LSBs of the 10−bit Remote 2 temperature measurement.
1. If this register is read, this register and the registers holding the MSB of each reading are frozen until read.
Table 46. Register 0x78 — Configuration Register 3 (Power−On Default = 0x00) (Note 1)
Bit No.
Mnemonic
R/W
Description
[0]
ALERT
Enable
R/W
ALERT = 1, Pin 5 (PWM2/SMBALERT) is configured as an SMBALERT interrupt output to
indicate out−of−limit error conditions.
[1]
THERM
R/W
THERM Enable = 1 enables THERM timer monitoring functionality on Pin 9. Also determined by
Bit 0 and Bit 1 (PIN9FUNC) of Configuration Register 4. When THERM is asserted, if the fans
are running and the boost bit is set, the fans run at full speed. Alternatively, THERM can be
programmed so that a timer is triggered to time how long THERM has been asserted.
[2]
BOOST
R/W
When THERM is an input and BOOST = 1, assertion of THERM causes all fans to run at the
maximum programmed duty cycle for fail−safe cooling.
[3]
FAST
R/W
FAST = 1, enables fast TACH measurements on all channels. This increases the TACH
measurement rate from once per second to once every 250 ms (4x).
[4]
DC1
R/W
DC1 = 1, enables TACH measurements to be continuously made on TACH1. Fans must be driven
by dc. Setting this bit prevents pulse stretching because it is not required for dc−driven motors.
[5]
DC2
R/W
DC2 = 1, enables TACH measurements to be continuously made on TACH2. Fans must be driven
by dc. Setting this bit prevents pulse stretching because it is not required for dc−driven motors.
[6]
DC3
R/W
DC3 = 1, enables TACH measurements to be continuously made on TACH3. Fans must be driven
by dc. Setting this bit prevents pulse stretching because it is not required for dc−driven motors.
[7]
DC4
R/W
DC4 = 1, enables TACH measurements to be continuously made on TACH4. Fans must be driven
by dc. Setting this bit prevents pulse stretching because it is not required for dc−driven motors.
1. These registers become read−only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to these registers fail.
Table 47. Register 0x79 — THERM Timer Status Register (Power−On Default = 0x00)
Bit No.
Mnemonic
R/W
[0]
ASRT/
TMR0
Read−only
This bit is set high on the assertion of the THERM input and is cleared on read. If the THERM
assertion time exceeds 45.52 ms, this bit is set and becomes the LSB of the 8−bit TMR
reading. This allows THERM assertion times from 45.52 ms to 5.82 sec to be reported back
with a resolution of 22.76 ms.
Description
[7:1]
TMR
Read−only
Times how long THERM input is asserted. These seven bits read zero until the THERM
assertion time exceeds 45.52 ms.
Table 48. THERM Timer Limit Register (Power−On Default = 0x00)
Bit No.
Mnemonic
R/W
[7:0]
LIMT
R/W
Description
Sets the maximum THERM assertion length allowed before an interrupt is generated. This
is an 8−bit limit with a resolution of 22.76 ms allowing THERM assertion limits of 45.52 ms
to 5.82 sec to be programmed. If the THERM assertion time exceeds this limit, Bit 5 (F4P)
of Interrupt Status Register 2 (0x42) is set. If the limit value is 0x00, an interrupt is generated
immediately on the assertion of the THERM input.
http://onsemi.com
55
ADT7475
Table 49. Register 0x7B — TACH Pulses per Revolution Register (Power−On Default = 0x55)
Bit No.
Mnemonic
R/W
[1:0]
FAN1
R/W
Sets the number of pulses to be counted when measuring Fan 1 speed. Can be used to
determine fan pulses per revolution for an unknown fan type.
Pulses Counted
00 = 1
01 = 2 (default)
10 = 3
11 = 4
Description
[3:2]
FAN2
R/W
Sets the number of pulses to be counted when measuring Fan 2 speed. Can be used to
determine fan pulses per revolution for an unknown fan type.
Pulses Counted
00 = 1
01 = 2 (default)
10 = 3
11 = 4
[5:4]
FAN3
R/W
Sets the number of pulses to be counted when measuring Fan 3 speed. Can be used to
determine fan pulses per revolution for an unknown fan type.
Pulses Counted
00 = 1
01 = 2 (default)
10 = 3
11 = 4
[7:6]
FAN4
R/W
Sets the number of pulses to be counted when measuring Fan 4 speed. Can be used to
determine fan pulses per revolution for an unknown fan type.
Pulses Counted
00 = 1
01 = 2 (default)
10 = 3
11 = 4
Table 50. Register 0x7C — Configuration Register 5 (Power−On Default = 0x01)
Bit No.
Mnemonic
R/W
(Note 1)
Description
[0]
TWOS
COMPL
R/W
Twos complement = 1, sets the temperature range to twos complement temperature range.
Twos complement = 0, changes the temperature range to Offset 64. When this bit is changed,
the ADT7475 interprets all relevant temperature register values as defined by this bit.
[1]
TempOffset
R/W
TempOffset = 0, sets offset range to −63°C to +64°C with 0.5°C resolution.
TempOffset = 1, sets offset range to −63°C to +127°C with 1°C resolution.
These settings apply to the 0x70, 0x71, and 0x72 registers (Remote 1, local, and Remote 2
temperature offset registers).
[2]
GPIOD
R/W
GPIO direction. When the GPIO function is enabled, this determines whether the GPIO is an
input (0) or an output (1).
[3]
GPIOP
R/W
GPIO polarity. When the GPIO function is enabled and is programmed as an output, this bit
determines whether the GPIO is active low (0) or high (1).
[4]
RES
[5]
R1 THERM
R/W
Reserved.
R1 THERM = 0, THERM temperature limit functionality is enabled for the Remote 1
temperature channel.
THERM can also be disabled on any channel by the following:
In offset 64 mode, writing −64°C to the appropriate THERM temperature limit.
In twos complement mode, writing −128°C to the appropriate THERM temperature limit.
[6]
Local
THERM
R/W
Local THERM = 0, THERM temperature limit functionality enabled for local temperature
channel.
THERM can also be disabled on any channel by the following:
In Offset 64 mode, writing −64°C to the appropriate THERM temperature limit.
In twos complement mode, writing −128°C to the appropriate THERM temperature limit.
[7]
R2 THERM
R/W
R2 THERM = 0, THERM temperature limit functionality enabled for Remote 2 temperature
channel.
THERM can also be disabled on any channel by the following:
In offset 64 mode, writing 64°C to the appropriate THERM temperature limit.
In twos complement mode, writing 128°C to the appropriate THERM temperature limit.
1. These registers become read−only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to these registers fail.
http://onsemi.com
56
ADT7475
Table 51. Register 0x7D — Configuration Register 4 (Power−On Default = 0x00)
Bit No.
Mnemonic
R/W
(Note 1)
Description
[1:0]
PIN9FUNC
R/W
These bits set the functionality of Pin 9:
00 = TACH4 (default)
01 = Bidirectional THERM
10 = SMBALERT
11 = GPIO
[2]
THERM
Disable
R/W
THERM Disable = 0, THERM overtemperature output is enabled assuming THERM is correctly
configured (Register 0x78, Register 0x7C, and Register 0x7D).
THERM Disable = 1, THERM overtemperature output is disabled on all channels.
THERM can also be disabled on any channel by the following:
In Offset 64 mode, writing −64°C to the appropriate THERM temperature limit.
In twos complement mode, writing −128°C to the appropriate THERM temperature limit.
[3]
Max/Full
on THERM
R/W
Max/Full on THERM = 0. When THERM limit is exceeded, fans go to full speed.
Max/Full on THERM = 1. When THERM limit is exceeded, fans go to maximum speed as
defined in Register 0x38, Register 0x39, and Register 0x3A.
[4:7]
RES
[5]
BpAttVCCP
[6:7]
RES
Unused.
R/W
Bypass VCCP attenuator. When set, the measurement scale for this channel changes from 0 V
(0x00) to 2.2965 V (0xFF).
Unused.
1. These registers become read−only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to these registers fail.
Table 52. Register 0x7E — Manufacturer’s Test Register 1 (Power−On Default = 0x00)
Bit No.
Mnemonic
R/W
Description
[7:0]
Reserved
Read−only
Manufacturer’s test register. These bits are reserved for manufacturer’s test purposes and
should not be written to under normal operation.
Table 53. Register 0x7F — Manufacturer’s Test Register 2 (Power−On Default = 0x00)
Bit No.
Mnemonic
R/W
[7:0]
Reserved
Read−only
Description
Manufacturer’s test register. These bits are reserved for manufacturer’s test purposes and
should not be written to under normal operation.
ORDERING INFORMATION
Temperature Range
Package Type
Package Option
Shipping†
ADT7475ARQZ
−40°C to +125°C
16−Lead QSOP
RQ−16
98 Rail
ADT7475ARQZ−REEL
−40°C to +125°C
16−Lead QSOP
RQ−16
2500 Tape & Reel
ADT7475ARQZ−RL7
−40°C to +125°C
16−Lead QSOP
RQ−16
1000 Tape & Reel
Device Number
†For information on tape and reel specifications, including part orientation and tape sizes, please refer to our Tape and Reel Packaging
Specifications Brochure, BRD8011/D.
*The “Z’’ suffix indicates Pb−Free part.
http://onsemi.com
57
ADT7475
PACKAGE DIMENSIONS
QSOP16
CASE 492−01
ISSUE O
−A−
Q
R
H x 45_
U
RAD.
0.013 X 0.005
DP. MAX
−B−
MOLD PIN
MARK
RAD.
0.005−0.010
TYP
G
L
0.25 (0.010)
M
P
T
DETAIL E
V
K
C
INCHES
DIM
MIN
MAX
A
0.189
0.196
B
0.150
0.157
C
0.061
0.068
D
0.008
0.012
F
0.016
0.035
G
0.025 BSC
H
0.008
0.018
J 0.0098 0.0075
K
0.004
0.010
L
0.230
0.244
M
0_
8_
N
0_
7_
P
0.007
0.011
Q
0.020 DIA
R
0.025
0.035
U
0.025
0.035
8_
V
0_
MILLIMETERS
MIN
MAX
4.80
4.98
3.81
3.99
1.55
1.73
0.20
0.31
0.41
0.89
0.64 BSC
0.20
0.46
0.249
0.191
0.10
0.25
5.84
6.20
0_
8_
0_
7_
0.18
0.28
0.51 DIA
0.64
0.89
0.64
0.89
0_
8_
−T−
D 16 PL
0.25 (0.010)
N 8 PL
NOTES:
1. DIMENSIONING AND TOLERANCING PER ANSI
Y14.5M, 1982.
2. CONTROLLING DIMENSION: INCH.
3. THE BOTTOM PACKAGE SHALL BE BIGGER THAN
THE TOP PACKAGE BY 4 MILS (NOTE: LEAD SIDE
ONLY). BOTTOM PACKAGE DIMENSION SHALL
FOLLOW THE DIMENSION STATED IN THIS
DRAWING.
4. PLASTIC DIMENSIONS DOES NOT INCLUDE MOLD
FLASH OR PROTRUSIONS. MOLD FLASH OR
PROTRUSIONS SHALL NOT EXCEED 6 MILS PER
SIDE.
5. BOTTOM EJECTOR PIN WILL INCLUDE THE
COUNTRY OF ORIGIN (COO) AND MOLD CAVITY I.D.
SEATING
PLANE
M
T B
S
A
S
M
J
F
DETAIL E
dBCOOL is a registered trademarks of Semiconductor Components Industries, LLC (SCILLC). Pentium is a registered trademark of Intel Corporation.
ON Semiconductor and
are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice
to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does SCILLC assume any liability
arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages.
“Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All
operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. SCILLC does not convey any license under its patent rights
nor the rights of others. SCILLC products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other applications
intended to support or sustain life, or for any other application in which the failure of the SCILLC product could create a situation where personal injury or death may occur. Should
Buyer purchase or use SCILLC products for any such unintended or unauthorized application, Buyer shall indemnify and hold SCILLC and its officers, employees, subsidiaries, affiliates,
and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death
associated with such unintended or unauthorized use, even if such claim alleges that SCILLC was negligent regarding the design or manufacture of the part. SCILLC is an Equal
Opportunity/Affirmative Action Employer. This literature is subject to all applicable copyright laws and is not for resale in any manner.
PUBLICATION ORDERING INFORMATION
LITERATURE FULFILLMENT:
Literature Distribution Center for ON Semiconductor
P.O. Box 5163, Denver, Colorado 80217 USA
Phone: 303−675−2175 or 800−344−3860 Toll Free USA/Canada
Fax: 303−675−2176 or 800−344−3867 Toll Free USA/Canada
Email: [email protected]
N. American Technical Support: 800−282−9855 Toll Free
USA/Canada
Europe, Middle East and Africa Technical Support:
Phone: 421 33 790 2910
Japan Customer Focus Center
Phone: 81−3−5773−3850
http://onsemi.com
58
ON Semiconductor Website: www.onsemi.com
Order Literature: http://www.onsemi.com/orderlit
For additional information, please contact your local
Sales Representative
ADT7475/D
Similar pages