BOURNS 4A12P-516-500

Features
■
■
■
■
Overcurrent/lightning protection to BELLCORE GR-1089
Typical application is secondary protection on telecom line cards
UL497A recognition
Thermal fuse links
4A12P-516-500 - Surge Line Protection Module
Electrical Characteristics
Product Dimensions
Resistance Value..........................................................................50 Ω
Resistance Tolerance ..................................................................±1 %
TCR ..................................................................................100 ppm/°C
Ratio Tolerance ........................................................................±0.5 %
Temperature Range...................................................-40 ºC to +85 ºC
MAX.
32.81
MAX.
(1.292)
2.80
(.110)
Physical Characteristics
Body Style ...........................................Dual In Line SMD - Twin Pack
Substrate Material ........................................................96 % Alumina
Lead Frame Material........................................Copper, solder coated
Flammability .....................................................Conforms to UL94V-0
Processability................Unit is only suitable for no-clean processing
Convection Reflow...................Unit will withstand 260 °, 20 seconds
Packaging .................16 “ diameter reels, 44 mm tape, 250 pcs./reel
12.70 14.59
(.500) (.575)
1 2
4
8
2.54 ± .13
(.100 ± .005)
10.16 ± .13
(.400 ± .005)
DIMENSIONS:
First Level AC Power Fault Resistors will remain within tolerance after testing.
R1B
F2B
F1B
22
21
19
15
13
12
1
2
4
8
10
11
F1A
F2A
R1A
R2A
100 Vrms, 0.17 Amp Short Circuit Current:
Duration...........................................................................15 minutes
How To Order
600 Vrms, 1.00 Amp Short Circuit Current:
Duration ........................................................60 One-second pulses
Model
(4A = Surface Mount)
5000 Volts Peak, 500 Amp Peak Current,
Max. Rise/Min. Decay Time 2x10 µs:
Number of Pulses ...............................1 simultaneous each polarity
MILLIMETERS
(INCHES)
R2B
50 Vrms, 0.33 Amp Short Circuit Current:
Duration...........................................................................15 minutes
Second Level Lightning Surge Resistor package must fail safely causing no fire, electrical, or
framentation hazard.
4.07 ± .25
(.160 ± .010)
Electrical Schematic
1000 Volts Peak, 100 Amp Peak Current,
Max. Rise/Min. Decay Time 10x1000 µs,
60 Seconds Between Pulses:
Number of Pulses ..............................25 each resistor each polarity
2500 Volts Peak, 500 Amp Peak Current,
Max. Rise/Min. Decay Time 2x10 µs,
60 Seconds Between Pulses:
Number of Pulses .............................10 simultaneous each polarity
10 11
3.72
(.146)
Functional Characteristics (per Bellcore GR-1089)
First Level Lightning Surge Resistors will remain within tolerance after testing.
7.87
(.310)
4A 12 P - 516 - 500
Number of Pins
Physical Configuration
Electrical Configuration
516 = Matched pair of resistors plus thermal fuse
Resistance Code
• 500 = 50 Ω
Second Level AC Power Fault Resistor package must fail safely causing no fire, electrical, or
framentation hazard. Device will fail prior to Bussman MDQ 1-6/10 A
fuse in series.
100 Vrms, 2.2 Amp Short Circuit Current:
Duration...........................................................................15 minutes
600 Vrms, 7 Amp Short Circuit Current:
Duration............................................................................5 seconds
250 Vrms, 25 Amp Short Circuit Current:
Duration...........................................................................15 minutes
600 Vrms, 60 Amp Short Circuit Current:
Duration............................................................................5 seconds
Reliable Electronic Solutions
Asia-Pacific: TEL +886- (0)2 25624117 • FAX +886- (0)2 25624116
Europe: TEL +41-41 7685555 • FAX +41-41 7685510
North America: TEL +1-909 781-5500 • FAX +1-909 781-5700
bourns.com
09/02
Specifications are subject to change without notice.
COPYRIGHT© 2002, BOURNS, INC. LITHO IN U.S.A. 09/02 e/L0211