ATMEL AT88SC6416C-SU Cryptomemory 64 kbit Datasheet

Features
• One of a Family of Devices with User Memories from 1-Kbit to 256-Kbit
• 64-Kbit (8-Kbyte) EEPROM User Memory
•
•
•
•
•
– Sixteen 512-byte (4-Kbit) Zones
– Self-timed Write Cycle
– Single Byte or 128-byte Page Write Mode
– Programmable Access Rights for Each Zone
2-Kbit Configuration Zone
– 37-byte OTP Area for User-defined Codes
– 160-byte Area for User-defined Keys and Passwords
High Security Features
– 64-bit Mutual Authentication Protocol (Under License of ELVA)
– Encrypted Checksum
– Stream Encryption
– Four Key Sets for Authentication and Encryption
– Eight Sets of Two 24-bit Passwords
– Anti-tearing Function
– Voltage and Frequency Monitor
Smart Card Features
– ISO 7816 Class A (5V) or Class B (3V) Operation
– ISO 7816-3 Asynchronous T = 0 Protocol (Gemplus® Patent)
– Supports Protocol and Parameters Selection for Faster Operation
– Multiple Zones, Key Sets and Passwords for Multi-application Use
– Synchronous 2-wire Serial Interface for Faster Device Initialization
– Programmable 8-byte Answer-To-Reset Register
– ISO 7816-2 Compliant Modules
Embedded Application Features
– Low Voltage Operation: 2.7V to 5.5V
– Secure Nonvolatile Storage for Sensitive System or User Information
– 2-wire Serial Interface
– 1.0 MHz Compatibility for Fast Operation
– Standard 8-lead Plastic Packages
– Same Pinout as 2-wire Serial EEPROMs
High Reliability
– Endurance: 100,000 Cycles
– Data Retention: 10 years
– ESD Protection: 4,000V min
CryptoMemory
64 Kbit
AT88SC6416C
Summary
Table 1. Pin Configuration
Pad
Description
ISO Module Contact
Standard Package Pin
VCC
Supply Voltage
C1
8
GND
Ground
C5
4
SCL/CLK
Serial Clock Input
C3
6
SDA/IO
Serial Data Input/Output
C7
5
RST
Reset Input
C2
NC
Figure 1. Package Options
Figure 2.
Figure 3.
Smart Card Module
VCC=C1
C5=GND
RST=C2
C6=NC
SCL/CLK=C3
NC=C4
C7=SDA/IO
C8=NC
8-lead SOIC, PDIP
NC
NC
NC
GND
1
2
3
4
8
7
6
5
VCC
NC
SCL
SDA
Rev. 5015HS–SMEM–11/08
Note: This is a summary document. A complete document is
available under NDA. For more information, please contact your
local Atmel sales office.
Description
The AT88SC6416C member of the CryptoMemory® family is a high-performance secure memory providing 64 Kbits of user memory with advanced security and cryptographic features built
in. The user memory is divided into 16 512-byte zones, each of which may be individually set
with different security access rights or effectively combined together to provide space for one to
sixteen data files.
Smart Card
Applications
The AT88SC6416C provides high security, low cost, and ease of implementation without the
need for a microprocessor operating system. The embedded cryptographic engine provides for
dynamic and symmetric mutual authentication between the device and host, as well as performing stream encryption for all data and passwords exchanged between the device and host. Up to
four unique key sets may be used for these operations. The AT88SC6416C offers the ability to
communicate with virtually any smart card reader using the asynchronous T = 0 protocol (Gemplus Patent) defined in ISO 7816-3. Communication speeds up to 153,600 baud are supported
by utilizing ISO 7816-3 Protocol and Parameter Selection.
Embedded
Applications
Through dynamic and symmetric mutual authentication, data encryption, and the use of
encrypted checksums, the AT88SC6416C provides a secure place for storage of sensitive information within a system. With its tamper detection circuits, this information remains safe even
under attack. A 2-wire serial interface running at 1.0 MHz is used for fast and efficient communications with up to 15 devices that may be individually addressed. The AT88SC6416C is
available in industry standard 8-lead packages with the same familiar pinout as 2-wire serial
EEPROMs.
Figure 2. Block Diagram
VCC
GND
SCL/CLK
SDA/IO
RST
Power
Management
Authentication,
Encryption and
Certification Unit
Synchronous
Interface
Data Transfer
Asynchronous
ISO Interface
Password
Verification
Reset Block
Answer to Reset
Random
Generator
EEPROM
Pin
Descriptions
Supply Voltage (VCC)
The VCC input is a 2.7V to 5.5V positive voltage supplied by the host.
Clock (SCL/CLK)
In the asynchronous T = 0 protocol, the SCL/CLK input is used to provide the device with a carrier frequency f. The nominal length of one bit emitted on I/O is defined as an “elementary time
unit” (ETU) and is equal to 372/f. When the synchronous protocol is used, the SCL/CLK input is
used to positive edge clock data into the device and negative edge clock data out of the device.
2
AT88SC6416C
5015HS–SMEM–11/08
AT88SC6416C
Reset (RST)
The AT88SC6416C provides an ISO 7816-3 compliant asynchronous answer to reset
sequence. When the reset sequence is activated, the device will output the data programmed
into the 64-bit answer-to-reset register. An internal pull-up on the RST input pad allows the
device to be used in synchronous mode without bonding RST. The AT88SC6416C does not
support the synchronous answer-to-reset sequence.
Serial Data
(SDA/IO)
The SDA pin is bidirectional for serial data transfer. This pin is open-drain driven and may be
wired with any number of other open drain or open collector devices. An external pull-up resistor
should be connected between SDA and VCC. The value of this resistor and the system capacitance loading the SDA bus will determine the rise time of SDA. This rise time will determine the
maximum frequency during read operations. Low value pull-up resistors will allow higher frequency operations while drawing higher average power. SDA/IO information applies to both
asynchronous and synchronous protocols.
When the synchronous protocol is used, the SCL/CLK input is used to positive edge clock data
into the device and negative edge clock data out of the device.
Table 2. DC Characteristics
Applicable over recommended operating range from VCC = +2.7 to 5.5V, TAC = -40oC to +85oC (unless otherwise noted)
Symbol
Parameter
Test Condition
VCC
Supply Voltage
ICC
Supply Current (VCC = 5.5V)
ICC
Min
Typ
Units
5.5
V
Async READ at 3.57MHz
5
mA
Supply Current (VCC = 5.5V)
Async WRITE at 3.57MHz
5
mA
ICC
Supply Current (VCC = 5.5V)
Synch READ at 1MHz
5
mA
ICC
Supply Current (VCC = 5.5V)
Synch WRITE at 1MHz
5
mA
ISB
Standby Current (VCC = 5.5V)
VIN = VCC or GND
1
mA
0
VCC x 0.2
V
0
VCC x 0.2
V
VIL
VIL
2.7
Max
(1)
SDA/IO Input Low Threshold
(1)
SCL/CLK Input Low Threshold
(1)
VIL
RST Input Low Threshold
0
VCC x 0.2
V
VIH
SDA/IO Input High Threshold(1)
VCC x 0.7
VCC
V
VIH
SCL/CLK Input High Threshold(1)
VCC x 0.7
VCC
V
VCC x 0.7
VCC
V
(1)
VIH
RST Input High Threshold
IIL
SDA/IO Input Low Current
0 < VIL < VCC x 0.15
15
uA
IIL
SCL/CLK Input Low Current
0 < VIL < VCC x 0.15
15
uA
IIL
RST Input Low Current
0 < VIL < VCC x 0.15
50
uA
IIH
SDA/IO Input High Current
VCC x 0.7 < VIH < VCC
20
uA
IIH
SCL/CLK Input High Current
VCC x 0.7 < VIH < VCC
100
uA
IIH
RST Input High Current
VCC x 0.7 < VIH < VCC
150
uA
VOH
SDA/IO Output High Voltage
20K ohm external pull-up
VCC x 0.7
VCC
V
VOL
SDA/IO Output Low Voltage
IOL = 1mA
0
VCC x 0.15
V
IOH
SDA/IO Output High Current
VOH
20
uA
Note: 1. VIL min and VIH max are reference only and are not tested.
3
5015HS–SMEM–11/08
Table 3. AC Characteristics
Applicable over recommended operating range from VCC = +2.7 to 5.5V,
TAC = -40oC to +85oC, CL = 30pF (unless otherwise noted)
Symbol
Parameter
Min
Max
Units
fCLK
Async Clock Frequency (VCC Range: +4.5 - 5.5V)
1
5
MHz
fCLK
Async Clock Frequency (VCC Range: +2.7 - 3.3V)
1
4
MHz
fCLK
Synch Clock Frequency
0
1
MHz
Clock Duty cycle
40
60
%
tR
Rise Time - I/O, RST
1
uS
tF
Fall Time - I/O, RST
1
uS
tR
Rise Time - CLK
9% x period
uS
tF
Fall Time - CLK
9% x period
uS
tAA
Clock Low to Data Out Valid
35
nS
tHD.STA
Start Hold Time
200
nS
tSU.STA
Start Set-up Time
200
nS
tHD.DAT
Data In Hold Time
10
nS
tSU.DAT
Data In Set-up Time
100
nS
tSU.STO
Stop Set-up Time
200
nS
tDH
Data Out Hold Time
20
nS
tWR
Write Cycle Time (at 25⋅C)
tWR
o
o
Write Cycle Time (-40 to +85 C)
Device
Operation For
Synchronous
Protocols
5
mS
7
mS
CLOCK and DATA TRANSITIONS: The SDA pin is normally pulled high with an external device.
Data on the SDA pin may change only during SCL low time periods (see Figure 5 on page 5).
Data changes during SCL high periods will indicate a start or stop condition as defined below.
START CONDITION: A high-to-low transition of SDA with SCL high is a start condition which
must precede any other command (see Figure 6 on page 6).
STOP CONDITION: A low-to-high transition of SDA with SCL high is a stop condition. After a
read sequence, the stop command will place the EEPROM in a standby power mode (see Figure 6 on page 6).
ACKNOWLEDGE: All addresses and data words are serially transmitted to and from the
EEPROM in 8-bit words. The EEPROM sends a zero to acknowledge that it has received each
word. This happens during the ninth clock cycle.
MEMORY RESET: After an interruption in protocol, power loss or system reset, any 2-wire part
can be reset by following these steps:
1. Clock up to 9 cycles.
2. Look for SDA high in each cycle while SCL is high.
3. Create a start condition.
4
AT88SC6416C
5015HS–SMEM–11/08
AT88SC6416C
Figure 3. Bus Timing for 2 wire communications
SCL: Serial Clock, SDA: Serial Data I/O
Figure 4. Write Cycle Timing:
SCL: Serial Clock, SDA: Serial Data I/O
SCL
SDA
8th BIT
ACK
WORDn
(1)
tWR
STOP
CONDITION
Note:
START
CONDITION
The write cycle time tWR is the time from a valid stop condition of a write sequence to the end of
the internal clear/write cycle.
Figure 5. Data Validity
DATA
CHANGE
ALLOWED
5
5015HS–SMEM–11/08
Figure 6. Start and Stop Definitions
Figure 7. Output Acknowledge
Device
Architecture
User Zones
6
The EEPROM user memory is divided into 16 zones of 4,096 bits each. Multiple zones allow for
different types of data or files to be stored in different zones. Access to the user zones is allowed
only after security requirements have been met. These security requirements are defined by the
user during the personalization of the device in the configuration memory. If the same security
requirements are selected for multiple zones, then these zones may effectively be accessed as
one larger zone
AT88SC6416C
5015HS–SMEM–11/08
AT88SC6416C
Figure 8. User Zone
ZONE
$0
$1
$2
$3
$4
$5
$6
$7
$000
-
512 Bytes
User 0
$1F8
User 1
$000
-
-
-
-
User 14
$1F8
$000
-
512 Bytes
User 15
$1F8
Control Logic
Access to the user zones occurs only through the control logic built into the device. This logic is
configurable through access registers, key registers and keys programmed into the configuration
memory during device personalization. Also implemented in the control logic is a cryptographic
engine for performing the various higher-level security functions of the device.
Configuration
Memory
The configuration memory consists of 2048 bits of EEPROM memory used for storing passwords, keys and codes and for defining security levels to be used for each user zone. Access
rights to the configuration memory are defined in the control logic and may not be altered by the
user.
7
5015HS–SMEM–11/08
Figure 9. Configuration Memory
$0
$1
$2
$3
$00
$4
$5
$6
$7
Answer To Reset
Identification
$08
Fab Code
MTZ
$10
Card Manufacturer Code
Lot History Code
Read Only
$18
DCR
Identification Number Nc
$20
AR0
PR0
AR1
PR1
AR2
PR2
AR3
PR3
$28
AR4
PR4
AR5
PR5
AR6
PR6
AR7
PR7
$30
AR8
PR8
AR9
PR9
AR10
PR10
AR11
PR11
$38
AR12
PR12
AR13
PR13
AR14
PR14
AR15
PR15
Access Control
$40
Issuer Code
$48
$50
$58
$60
$68
For Authentication and Encryption use
Cryptography
For Authentication and Encryption use
Secret
$70
$78
$80
$88
$90
$98
$A0
$A8
$B0
PAC
Write 0
PAC
Read 0
$B8
PAC
Write 1
PAC
Read 1
$C0
PAC
Write 2
PAC
Read 2
$C8
PAC
Write 3
PAC
Read 3
$D0
PAC
Write 4
PAC
Read 4
$D8
PAC
Write 5
PAC
Read 5
$E0
PAC
Write 6
PAC
Read 6
$E8
PAC
Write 7
PAC
Read 7
Password
$F0
Reserved
Forbidden
$F8
8
AT88SC6416C
5015HS–SMEM–11/08
AT88SC6416C
Security Fuses
There are three fuses on the device that must be blown during the device personalization process. Each fuse locks certain portions of the configuration memory as OTP memory. Fuses are
designed for the module manufacturer, card manufacturer and card issuer and should be blown
in sequence, although all programming of the device and blowing of the fuses may be performed
at one final step.
Protocol
Selection
The AT88SC6416C supports two different communication protocols.
•
Smart Card Applications: The asynchronous T = 0 protocol defined by ISO 7816-3 is used
for compatibility with the industry’s standard smart card readers.
•
Embedded Applications: A 2-wire serial interface is used for fast and efficient
communication with logic or controllers.
The power-up sequence determines which of the two communication protocols will be used.
Asynchronous
T = 0 Protocol
This power-up sequence complies with ISO 7816-3 for a cold reset in smart card applications.
•
VCC goes high; RST, I/O-SDA and CLK-SCL are low.
•
Set I/O-SDA in receive mode.
•
Provide a clock signal to CLK-SCL.
•
RST goes high after 400 clock cycles.
The device will respond with a 64-bit ATR code, including historical bytes to indicate the memory
density within the CryptoMemory family. Once the asynchronous mode has been selected, it is
not possible to switch to the synchronous mode without powering off the device.
Figure 10. Asynchronous T = 0 Protocol (Gemplus Patent)
Vcc
I/O-SDA
ATR
RST
CLK-SCL
After a successful ATR, the Protocol and Parameter Selection (PPS) protocol, as defined by ISO
7816-3, may be used to negotiate the communications speed with CryptoMemory devices 32 Kbits
and larger. CryptoMemory supports D values of 1, 2, 4, 8, 12, and 16 for an F value of 372. Also
supported are D values of 8 and 16 for F = 512. This allows selection of 8 communications speeds
ranging from 9600 baud to 153,600 baud.
Synchronous
2-wire Serial
Interface
The synchronous mode is the default after powering up VCC due to an internal pull-up on RST.
For embedded applications using CryptoMemory in standard plastic packages, this is the only
communication protocol.
•
•
Power-up VCC, RST goes high also.
After stable VCC, CLK-SCL and I/O-SDA may be driven.
9
5015HS–SMEM–11/08
Figure 11. Synchronous 2-wire Protocol (Gemplus Patent)
Vcc
I/O-SDA
RST
CLK-SCL
Note:
Communication
Security Modes
1
2
3
4
5
Five clock pulses must be sent before the first command is issued.
Communications between the device and host operate in three basic modes. Standard mode is
the default mode for the device after power-up. Authentication mode is activated by a successful
authentication sequence. Encryption mode is activated by a successful encryption activation following a successful authentication.
Table 4. Communication Security Modes(1)
Mode
Configuration Data
User Data
Passwords
Data Integrity Check
Standard
Clear
Clear
Clear
MDC
Authentication
Clear
Clear
Encrypted
MAC
Encryption
Clear
Encrypted
Encrypted
MAC
Note:
1. Configuration data include viewable areas of the Configuration Zone except the passwords:
MDC: Modification Detection Code
MAC: Message Authentication Code.
Security
Options
Anti-tearing
In the event of a power loss during a write cycle, the integrity of the device’s stored data may be
recovered. This function is optional: the host may choose to activate the anti-tearing function,
depending on application requirements. When anti-tearing is active, write commands take longer
to execute, since more write cycles are required to complete them, and data are limited to eight
bytes.
Data are written first to a buffer zone in EEPROM instead of the intended destination address,
but with the same access conditions. The data are then written in the required location. If this
second write cycle is interrupted due to a power loss, the device will automatically recover the
data from the system buffer zone at the next power-up.
In 2-wire mode, the host is required to perform ACK polling for up to 8 ms after write commands
when anti-tearing is active. At power-up, the host is required to perform ACK polling, in some
cases for up to 2 ms, in the event that the device needs to carry out the data recovery process.
Write Lock
If a user zone is configured in the write lock mode, the lowest address byte of an 8-byte page
constitutes a write access byte for the bytes of that page.
Example: The write lock byte at $080 controls the bytes from $080 to $087.
10
AT88SC6416C
5015HS–SMEM–11/08
AT88SC6416C
Figure 12. Write Lock Example
Address
$0
$1
$2
$3
$4
$5
$6
$7
$080
11011001
xxxx xxxx
xxxx xxxx
xxxx xxxx
xxxx xxxx
xxxx xxxx
xxxx xxxx
xxxx xxxx
locked
locked
locked
The write lock byte may also be locked by writing its least significant (rightmost) bit to “0”. Moreover, when write lock mode is activated, the write lock byte can only be programmed – that is,
bits written to “0” cannot return to “1”.
In the write lock configuration, only one byte can be written at a time. Even if several bytes are
received, only the first byte will be taken into account by the device.
Password
Verification
Passwords may be used to protect read and/or write access of any user zone. When a valid
password is presented, it is memorized and active until power is turned off, unless a new password is presented or RST becomes active. There are eight password sets that may be used to
protect any user zone. Only one password is active at a time, but write passwords give read
access also.
Authentication
Protocol
The access to a user zone may be protected by an authentication protocol. Any one of four keys
may be selected to use with a user zone.
The authentication success is memorized and active as long as the chip is powered, unless a
new authentication is initialized or RST becomes active. If the new authentication request is not
validated, the card loses its previous authentication and it should be presented again. Only the
last request is memorized.
Note:
Password and authentication may be presented at any time and in any order. If the trials limit has
been reached (after four consecutive incorrect attempts), the password verification or authentication process will not be taken into account.
Figure 13. Password and Authentication Operations
VERIFY RPW
DATA
Checksum (CS)
VERIFY CS
VERIFY CS
CS
Write DATA
11
5015HS–SMEM–11/08
Checksum
The AT88SC6416C implements a data validity check function in the form of a checksum, which
may function in standard, authentication or encryption modes.
In the standard mode, the checksum is implemented as a Modification Detection Code (MDC), in
which the host may read a MDC from the device in order to verify that the data sent was
received correctly.
In the authentication and encryption modes, the checksum becomes more powerful since it provides a bidirectional data integrity check and data origin authentication capability in the form of a
Message Authentication Code (MAC). Only the host/device that carried out a valid authentication is capable of computing a valid MAC. While operating in the authentication or encryption
modes, the use of a MAC is required. For an ongoing command, if the device calculates a MAC
different from the MAC transmitted by the host, not only is the command abandoned but the
mode is also reset. A new authentication and/or encryption activation will be required to reactivate the MAC.
Encryption
The data exchanged between the device and the host during read, write and verify password
commands may be encrypted to ensure data confidentiality.
The issuer may choose to require encryption for a user zone by settings made in the configuration memory. Any one of four keys may be selected for use with a user zone. In this case,
activation of the encryption mode is required in order to read/write data in the zone and only
encrypted data will be transmitted. Even if not required, the host may elect to activate encryption
provided the proper keys are known.
Supervisor Mode
Enabling this feature allows the holder of one specific password to gain full access to all eight
password sets, including the ability to change passwords.
Modify Forbidden
No write access is allowed in a user zone protected with this feature at any time. The user zone
must be written during device personalization prior to blowing the security fuses.
Program Only
For a user zone protected by this feature, data within the zone may be changed from a “1” to a
“0”, but never from a “0” to a “1”.
Initial Device
Programming
To enable the security features of CryptoMemory, the device must first be personalized to set up
several registers and load in the appropriate passwords and keys. This is accomplished through
programming the configuration memory of CryptoMemory using simple write and read commands. To gain access to the configuration memory, the secure code must first be successfully
presented. For the AT88SC6416C device, the secure code is $F7 62 0B. After writing and verifying data in the configuration memory, the security fuses must be blown to lock this information in
the device. For additional information on personalizing CryptoMemory, please see the application notes Programming CryptoMemory for Embedded Applications and Initializing
CryptoMemory for Smart Card Applications (at www.Atmel.com).
12
AT88SC6416C
5015HS–SMEM–11/08
AT88SC6416C
Ordering Information
Ordering Code
Package
Voltage Range
Temperature Range
AT88SC6416C-MJ
AT88SC6416C-MP
M2 – J Module
M2 – P Module
2.7V–5.5V
Commercial (0°C–70°C)
AT88SC6416C-PU
AT88SC6416C-SU
8P3
8S1
2.7V–5.5V
Lead-free/Halogen-free/Industrial
(−40°C–85°C)
AT88SC6416C-WI
7 mil wafer
2.7V–5.5V
Industrial (−40°C–85°C)
Package Type(1)
Description
M2 – J Module
M2 ISO 7816 Smart Card Module
M2 – P Module
M2 ISO 7816 Smart Card Module with Atmel® Logo
8P3
8-lead, 0.300” Wide, Plastic Dual Inline Package (PDIP)
8S1
8-lead, 0.150” Wide, Plastic Gull Wing Small Outline Package (JEDEC SOIC)
Note:
1. Formal drawings may be obtained from an Atmel sales office.
13
5015HS–SMEM–11/08
Packaging Information
Ordering Code: MJ
Module Size: M2
Dimension*: 12.6 x 11.4 [mm]
Glob Top: Round - Æ 8.5 [mm]
Thickness: 0.58 [mm]
Pitch: 14.25 mm
Ordering Code: MP
Module Size: M2
Dimension*: 12.6 x 11.4 [mm]
Glob Top: Square - 8.8 x 8.8 [mm]
Thickness: 0.58 [mm]
Pitch: 14.25 mm
*Note: The module dimensions listed refer to the dimensions of the exposed metal contact area. The actual dimensions
of the module after excise or punching from the carrier tape are generally 0.4 mm greater in both directions
(i.e., a punched M2 module will yield 13.0 x 11.8 mm).
14
AT88SC6416C
5015HS–SMEM–11/08
AT88SC6416C
Ordering Code: SU
8-lead SOIC
C
1
E
E1
L
N
Ø
TOP VIEW
END VIEW
e
b
COMMON DIMENSIONS
(Unit of Measure = mm)
A
A1
D
SIDE VIEW
SYMBOL
MIN
NOM
MAX
A
1.35
–
1.75
A1
0.10
–
0.25
b
0.31
–
0.51
C
0.17
–
0.25
D
4.80
–
5.05
E1
3.81
–
3.99
E
5.79
–
6.20
e
NOTE
1.27 BSC
L
0.40
–
1.27
θ
0°
–
8°
Note: These drawings are for general information only. Refer to JEDEC Drawing MS-012, Variation AA for proper dimensions, tolerances, datums, etc.
3/17/05
R
1150 E. Cheyenne Mtn. Blvd.
Colorado Springs, CO 80906
TITLE
8S1, 8-lead (0.150" Wide Body), Plastic Gull Wing
Small Outline (JEDEC SOIC)
DRAWING NO.
REV.
8S1
C
15
5015HS–SMEM–11/08
Ordering Code: PU
8-lead PDIP
E
1
E1
N
Top View
c
eA
End View
COMMON DIMENSIONS
(Unit of Measure = inches)
D
e
D1
A2 A
SYMBOL
MIN
NOM
A
b2
b3
b
4 PLCS
Side View
L
0.210
NOTE
2
A2
0.115
0.130
0.195
b
0.014
0.018
0.022
5
b2
0.045
0.060
0.070
6
6
b3
0.030
0.039
0.045
c
0.008
0.010
0.014
D
0.355
0.365
0.400
D1
0.005
E
0.300
E1
0.240
e
3
3
0.310
0.325
4
0.250
0.280
3
0.100 BSC
eA
L
Notes:
MAX
0.300 BSC
0.115
0.130
4
0.150
2
1. This drawing is for general information only; refer to JEDEC Drawing MS-001, Variation BA for additional information.
2. Dimensions A and L are measured with the package seated in JEDEC seating plane Gauge GS-3.
3. D, D1 and E1 dimensions do not include mold Flash or protrusions. Mold Flash or protrusions shall not exceed 0.010 inch.
4. E and eA measured with the leads constrained to be perpendicular to datum.
5. Pointed or rounded lead tips are preferred to ease insertion.
6. b2 and b3 maximum dimensions do not include Dambar protrusions. Dambar protrusions shall not exceed 0.010 (0.25 mm).
01/09/02
R
16
2325 Orchard Parkway
San Jose, CA 95131
TITLE
8P3, 8-lead, 0.300" Wide Body, Plastic Dual
In-line Package (PDIP)
DRAWING NO.
REV.
8P3
B
AT88SC6416C
5015HS–SMEM–11/08
AT88SC6416C
Revision History
Doc. Rev.
Date
Comments
5015HS
11/2008
Updated timing diagrams.
5015GS
4/2007
Final release version.
5015GS
3/2007
Implemented revision history.
Removed Industrial package offerings.
Removed 8Y4 package offering.
Replaced User Zone, Configuration Memory, and Write Lock
Example tables with new information.
17
5015HS–SMEM–11/08
Headquarters
International
Atmel Corporation
2325 Orchard Parkway
San Jose, CA 95131
USA
Tel: 1(408) 441-0311
Fax: 1(408) 487-2600
Atmel Asia
Room 1219
Chinachem Golden Plaza
77 Mody Road Tsimshatsui
East Kowloon
Hong Kong
Tel: (852) 2721-9778
Fax: (852) 2722-1369
Atmel Europe
Le Krebs
8, Rue Jean-Pierre Timbaud
BP 309
78054 Saint-Quentin-enYvelines Cedex
France
Tel: (33) 1-30-60-70-00
Fax: (33) 1-30-60-71-11
Atmel Japan
9F, Tonetsu Shinkawa Bldg.
1-24-8 Shinkawa
Chuo-ku, Tokyo 104-0033
Japan
Tel: (81) 3-3523-3551
Fax: (81) 3-3523-7581
Technical Support
[email protected]
Sales Contact
www.atmel.com/contacts
Product Contact
Web Site
www.atmel.com
Literature Requests
www.atmel.com/literature
Disclaimer: The information in this document is provided in connection with Atmel products. No license, express or implied, by estoppel or otherwise, to any
intellectual property right is granted by this document or in connection with the sale of Atmel products. EXCEPT AS SET FORTH IN ATMEL’S TERMS AND CONDITIONS OF SALE LOCATED ON ATMEL’S WEB SITE, ATMEL ASSUMES NO LIABILITY WHATSOEVER AND DISCLAIMS ANY EXPRESS, IMPLIED OR STATUTORY
WARRANTY RELATING TO ITS PRODUCTS INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR
PURPOSE, OR NON-INFRINGEMENT. IN NO EVENT SHALL ATMEL BE LIABLE FOR ANY DIRECT, INDIRECT, CONSEQUENTIAL, PUNITIVE, SPECIAL OR INCIDENTAL DAMAGES (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF PROFITS, BUSINESS INTERRUPTION, OR LOSS OF INFORMATION) ARISING OUT OF
THE USE OR INABILITY TO USE THIS DOCUMENT, EVEN IF ATMEL HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Atmel makes no
representations or warranties with respect to the accuracy or completeness of the contents of this document and reserves the right to make changes to specifications
and product descriptions at any time without notice. Atmel does not make any commitment to update the information contained herein. Unless specifically provided
otherwise, Atmel products are not suitable for, and shall not be used in, automotive applications. Atmel’s products are not intended, authorized, or warranted for use
as components in applications intended to support or sustain life.
© 2008 Atmel Corporation. All rights reserved. Atmel ®, Atmel logo and combinations thereof, CryptoMemory® and others, are registered
trademarks or trademarks of Atmel Corporation or its subsidiaries. Other terms and product names may be trademarks of others.
5015HS–SMEM–11/08